Rejuvenation C0933 Operating and maintenance manual

Towel Warmer Installation Procedure
1. The incoming power feed goes to a deep single gang electrical box (for timer). This electrical box can be located
anywhere in the room, although we recommend it be alongside your light switches.
2. A power feed then goes from the timer electrical box to a single gang electrical box (for Towel Warmer). The location
of this electrical box governs the location of your Towel Warmer (see g. 2).
3. Wall studs or plywood backing is required at all bracket locations. See gure 2 for bracket locations.
Rough-in Requirements
(see gure 3)
1
Do not connect the Towel Warmer to the power supply until all instructions have been read and installation carried out in
accord with them. The heating element is 150W 110V. The element conforms to UL standards and the unit to CSA
standards (File ref: 229718). Ensure the CSA label is visible. TURN OFF POWER SUPPLY BEFORE PROCEEDING.
1. Feed the electrical cord located at the side of the Towel Warmer rst through the round tube and then through the
cover plate.
2. Complete all electrical connections as shown in gure 3.
3. Fit tube over Towel Warmer element sleeve until it meets the hexagonal chrome collar.
4. Push cover plate onto tube.
5. Screw cover plate to electric box with the enclosed screws. Adjust where necessary.
Warning: In case of damage or failure of the Towel Warmer the unit should be returned to the manufacturer or their distributor. The warranty
is NOT VALID in case of improper use or installation. Product is designed for use within Canada and the United States only.
Installation Instructions
(see gure 1)
2
1. Check all items have been received. You should have Towel Warmer, hardwire kit, programmable timer and mounting
discs including xings. Read all instructions before continuing.
2. Fix mounting discs "A" using the screws provided and in locations as shown on gure 2.
3. Mount towel warmer and slide brackets “B” over mounting discs “A”.
4. Fasten Towel Warmer using set screws "C" to lock mounting discs “A" into brackets "B". Ensure the Towel Warmer is
rmly and safely xed.
Hardwire
3
g. 1
B
C
A
C
2550 NW Nicolai Street Portland Oregon 97210 Customer Service: 888 401-1900 rejuvenation.com

Model # Output
C0933 Wall Mount Electric
Hardwire
Chrome 31 150W
2512Btu
600 x 875 23.5” x 34.5” Brass
C0934 Wall Mount Electric
Hardwire
Polished
Nickel
31 150W
2512Btu
600 x 875 23.5” x 34.5” Brass
C0932Wall Mount Electric
Hardwire
Brushed
Nickel
31 150W
2512Btu
600 x 875 23.5” x 34.5” Brass
150 watt, 12" long, 120 volt, 60 Htz, IP55 cord, ULC approved
Warranty: Towel Warmer: 5 years, Heating Element: 1 year, Programmable Timer: 2 years
Fixings: Screws, and Allen Key (if needed) are included
Heating Element Location:
many years to come. ON NO ACCOUNT should any household bleaches, detergents, abrasive polishes, steel wool or other cleaning
agents be used on this item.
Metal Type
WxH (Inches)
WxH (mm)
Element SizeWeight (lb)
Finish
Description
2550 NW Nicolai Street Portland Oregon 97210 Customer Service: 888 401-1900 rejuvenation.com

Timer Installation Procedure
Installation
1
Install the timer as shown in gure 3.
Apply power at the circuit breaker.
1
2
Power On
2
Pry the switch door open from the
bottom using a small screwdriver.
Ensure the ON/OFF selector is set
to ON .
Reset the switch using a
paperclip. 0:00 and MO will ash.
1
2
3
Setting the Clock
3
Set the time using the HOUR and MIN buttons.
Set the day by using the DAY button.
Press one of the control buttons or close the switc h door
to return to normal operation.
1
2
3
Programming
5
Pry the timer door open using a small screwdriver.
Press the PGM button to display a
program and its On or O time. For
example, when you rst press PGM ,
program number 1 ( P1 ) and its On time
(ON ) will appear. -:-- will appear instead
of the time if the program is not set (inactive).
Press the DAY button to select the day
to which you want to apply the program.
NOTE: If you want to apply the program
to every day of the week, press DAY
until all the days are displayed. (This
still counts as 1 program, not 7)
Press the HOUR and MIN buttons to set the ON time
(time when you want the towel warmer to turn on)
After you have programmed the ON time, press the PG M
button to display the OFF time (time when you want the
towel warmer to turn o).
Repeat steps 3 through 5 to program
the OFF time. If the program ON time is
set for every day of the week, the
program OFF time will automatically be
set for every day.
To set another program, repeat steps 2 through 6.
Programs that are not set will remain inactive.
Press one of the control buttons or close the timer door
to return to normal operation.
1
3
4
2
5
Troubleshooting
6
Blank display
•
Verify circuit breaker at main
panel.
•
Ensure the ON/OFF selector is at
ON.
•
Reset the switch using a paper
clip.
Programs do not run
as expected
•
Make sure the switch is properly
programmed.
•
Note that -:-- indicates an inactive
program, 00:00 indicates
midnight.
The programmable switch has 2 operating modes: manu al
(MAN )and automatic ( AUTO ). To switch mode, press the timer
door for 3 seconds.
Selecting the Operating Mode
4
You can set up to 7 programs. To set a program, you need to
enter its start time ( ON ) and its end time ( OFF ).
6
7
8
Clearing a Program
Press the PGM button until the desired program is selected.
Hold the PGM button for 3 seconds. -:-- appears when the
program is erased.
Manual Mode
The programmable timer operates as a regular
switch. Briey press the switch door to turn the
towel warmer On or O. The mode ( MAN ) and
state ( ON or OFF )are displayed.
Automatic Mode
The programmable timer follows the
programmed schedule. The mode (AUTO ),
state ( ON or OFF )and current program
number are displayed. To temporarily override
the programmed schedule, briey press the
switch door. The new state ( ON or OFF ) will ash to show that
this state is temporary. The override remains in ef fect until you
press the timer door again or until the beginning of the next
program.
2550 NW Nicolai Street Portland Oregon 97210 Customer Service: 888 401-1900 rejuvenation.com