manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wolf
  6. •
  7. Warming Drawer
  8. •
  9. Wolf WD30 User manual

Wolf WD30 User manual

Other manuals for WD30

1

Other Wolf Warming Drawer manuals

Wolf 13005870 Service manual

Wolf

Wolf 13005870 Service manual

Wolf WWD30-2 User manual

Wolf

Wolf WWD30-2 User manual

Wolf MWD24-2 User manual

Wolf

Wolf MWD24-2 User manual

Wolf Warming Drawer User manual

Wolf

Wolf Warming Drawer User manual

Wolf Warming Drawer User manual

Wolf

Wolf Warming Drawer User manual

Wolf WWDFRONT/B User manual

Wolf

Wolf WWDFRONT/B User manual

Wolf WWD30 User manual

Wolf

Wolf WWD30 User manual

Wolf WD30 Owner's manual

Wolf

Wolf WD30 Owner's manual

Wolf WWD30 User manual

Wolf

Wolf WWD30 User manual

Wolf WARMING DRAWERS User manual

Wolf

Wolf WARMING DRAWERS User manual

Wolf WWD30 Owner's manual

Wolf

Wolf WWD30 Owner's manual

Wolf WWD30 Instructions for use

Wolf

Wolf WWD30 Instructions for use

Wolf WWD30 User manual

Wolf

Wolf WWD30 User manual

Wolf CW24/S User manual

Wolf

Wolf CW24/S User manual

Wolf ICBWWD30 User manual

Wolf

Wolf ICBWWD30 User manual

Wolf WWD30 Instructions for use

Wolf

Wolf WWD30 Instructions for use

Wolf WWD30-2 User manual

Wolf

Wolf WWD30-2 User manual

Wolf WWD30-2 Service manual

Wolf

Wolf WWD30-2 Service manual

Wolf ICBWWD30 User manual

Wolf

Wolf ICBWWD30 User manual

Wolf ICBWWD30 User manual

Wolf

Wolf ICBWWD30 User manual

Wolf WWD30 User manual

Wolf

Wolf WWD30 User manual

Wolf ICBWWD30O User manual

Wolf

Wolf ICBWWD30O User manual

Wolf WWDFRONT/B User manual

Wolf

Wolf WWDFRONT/B User manual

Wolf WWD30 User manual

Wolf

Wolf WWD30 User manual

Popular Warming Drawer manuals by other brands

Siemens HW 290 Series instruction manual

Siemens

Siemens HW 290 Series instruction manual

Viking DEWD102SS Quick reference guide

Viking

Viking DEWD102SS Quick reference guide

Miele ESW 6229 Operating and installation instructions

Miele

Miele ESW 6229 Operating and installation instructions

Brandt WD1014X user guide

Brandt

Brandt WD1014X user guide

APW Wyott WD-2CMF Specification sheet

APW Wyott

APW Wyott WD-2CMF Specification sheet

KitchenAid KOWT107ESS installation instructions

KitchenAid

KitchenAid KOWT107ESS installation instructions

Hanseatic TCN14J6D-S user manual

Hanseatic

Hanseatic TCN14J6D-S user manual

Cardini WD6299 instruction manual

Cardini

Cardini WD6299 instruction manual

GE Monogram ZTD910SBSS Dimension Guide

GE

GE Monogram ZTD910SBSS Dimension Guide

Dacor IWD24 Planning guide

Dacor

Dacor IWD24 Planning guide

Nordmende WD515IX user manual

Nordmende

Nordmende WD515IX user manual

Electrolux EW30WD55GS Use and care guide

Electrolux

Electrolux EW30WD55GS Use and care guide

Jenn-Air JWD6030CDX user guide

Jenn-Air

Jenn-Air JWD6030CDX user guide

Fisher & Paykel WB30SDEX1 Quick reference guide

Fisher & Paykel

Fisher & Paykel WB30SDEX1 Quick reference guide

Fisher & Paykel WB60SDTB1-SET Quick reference guide

Fisher & Paykel

Fisher & Paykel WB60SDTB1-SET Quick reference guide

Bosch HWD2720UC installation manual

Bosch

Bosch HWD2720UC installation manual

KitchenAid KEWS105 Use & care guide

KitchenAid

KitchenAid KEWS105 Use & care guide

Baumatic WD01SS user manual

Baumatic

Baumatic WD01SS user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION INSTRUCTIONS
WARMING DRAWER
As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equip-
ment. There are two types of potential
hazards that may occur during installation.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights informa-
tion that is especially relevant to a problem-
free installation.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
states a hazard that may cause serious
injury or death if precautions are not
followed.
WOLF®is a registered trademark of Wolf Appliance Company, LLC
3
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be
completed by a qualified installer or Wolf
authorized service center technician.
Installer:
Please read the entire Installation
Instructions prior to installation. Save these
instructions for the local inspector’s refer-
ence, then leave them with the homeowner.
Homeowner:
Please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
Any questions or problems about the
installation should be directed to your Wolf
dealer or Wolf Appliance Company, LLC at
800-332-9513. You can also visit our website
at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be
installed in accordance with National Electrical
Codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and amperage ratings are listed on the product
rating plate.
Record the model and serial numbers before
installing the warming drawer. Both numbers
are listed on the rating plate, located on the
inside of the drawer front.
Model Number WD30
Serial Number
BEFORE YOU START
Proper installation is the responsibility of
the installer. Product failure due to
improper installation is not covered under
the Wolf warranty. Refer to the Warming
Drawer Use & Care Information for
warranty details.
Before you install the warming drawer,
make sure you have the Wolf accessory
drawer front called for in your installation.
IMPORTANT NOTE:
If you are installing
the warming drawer with integrated drawer
front, make sure that your cabinetry meets
the minimum 33" (838) width and 26" (660)
depth requirements for this installation.
Check with local utilities for electrical codes
that apply in your area. Local codes vary.
Installation, electrical connections and
grounding must comply with applicable
codes. In the absence of local codes, the
drawer should be installed in accordance
with National Electrical Code ANSI/NFPA
70-1990 or latest edition.
This appliance must be properly grounded.
Refer to Electrical Requirements on
page 12.
Make sure you have the tools and materials
necessary for proper installation.
Any required service must be performed by
a Wolf authorized service center. Wolf is not
responsible for service required to correct a
faulty installation.
WOLF WARMING DRAWER
CONTACT
INFORMATION
Wolf Customer
Service:
800-332-9513
Website:
wolfappliance.com
4
WOLF WARMING DRAWER
DRAWER FRONT OPTIONS
IMPORTANT NOTE:
Model WD30 must be
installed with a Wolf stainless steel or
integrated drawer front.
Classic Stainless Steel
WDFRONT/S
Platinum Stainless Steel
WDFRONT/P
Carbon Stainless Steel
WDFRONT/B
Integrated Drawer Front
WDFRONT/I
(accepts wood panel)
Drawer fronts are ordered and shipped as
sales accessories and include additional
installation instructions. Stainless steel drawer
fronts include a matching tubular handle.
The integrated drawer front accepts a custom
wood panel and handle to be provided by the
homeowner. Optional stainless steel tubular
handles in classic, platinum and carbon stain-
less finishes are available as sales accessories.
Optional accessories are available through
your Wolf dealer. You can also visit our
website at wolfappliance.com and click on the
accessories section for Model WD30.
TOOLS AND MATERIALS REQUIRED
Wood screws or other hardware to install
the solid platform or runners that support
the warming drawer
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber
for runners—runners must be able to
support 175 lbs (79 kg)
2" (51) x 2" (51) or 2" (51) x 4" (102) lumber
for anti-tip block
Power saw
Level
Drill and 1/16" bit
Phillips screwdriver
4 wood screws (provided)
Model WD30
with Stainless Steel
Drawer Front
Model WD30
with Integrated
Drawer Front
5
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
MODEL WD30
with Stainless Steel Drawer Front
Overall Width 297/8" (759)
Overall Height 101/4" (340)
Overall Depth (behind frame) 231/16" (586)
Minimum Cabinet Width 30" (762)
Minimum Cabinet Depth 24" (610)
Minimum Base Support 175 lbs (79 kg)
Opening Width 281/2" (724)
Opening Height 91/4" (235)
Opening Depth 231/2" (597)
Dimensions may vary to +
–1/8" (3).
STAINLESS STEEL DRAWER FRONT
INSTALLATION SPECIFICATIONS
The illustrations below and on the following
pages provide the overall dimensions, finished
rough opening dimensions and electrical
placement for the Wolf warming drawer with
stainless steel drawer front.
Wolf recommends using a 33" (838) wide
cabinet for the warming drawer with stainless
steel drawer front. A minimum 30" (762) wide
by 24" (610) deep cabinet is required with a
minimum base support of 175 lbs (79 kg).
Refer to installation instructions provided with
the stainless steel drawer front for detailed
specifications. These instructions can also be
found on the Wolf website, wolfappliance.com.
UNDERCOUNTER INSTALLATION
For undercounter installations, 231/2" (597)
from the bottom of the warming drawer
opening to the floor is recommended. It must
be installed a minimum of 5" (127) above the
floor or 1" (25) above the toe kick.
The Wolf warming drawer with stainless steel
drawer front may be installed below an electric
or gas cooktop, provided the warming drawer
is fully enclosed, top and bottom. Refer to
installation instructions for the cooktop for
additional specifications. Dimensions will vary
according to the specific installation.
281/2"(724)
OPENING WIDTH
E
5"
(127)
4"
(102)
33"(838)
RECOMMENDED CABINET WIDTH
30"min (762)
ALLOW FOR
5/8"OVERLAP
ON ALL SIDES
36"(914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
5"min (127)
BOTTOM
OF OPENING
TO FLOOR
24"min (610)
CABINET DEPTH
91/4"(235)
OPENING
HEIGHT
231/2"min (597)
OPENING DEPTH
2"(51) x 2"(51)
ANTI-TIP BLOCK
23/8"
(60)
231/16"(586)
BEHIND FRAME
297/8"(759)
OVERALL WIDTH
9"
(229)
101/4"
(260)
Overall Dimensions – Stainless Steel Drawer Front
Undercounter Installation – Stainless Steel Drawer Front
STAINLESS STEEL
DRAWER FRONT
Refer to installation
instructions
provided with the
stainless steel
drawer front for
detailed specifica-
tions. These
instructions can
also be found on
the Wolf website,
wolfappliance.com.
6
WOLF WARMING DRAWER
281/2"(724)
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
281/2"(724)
WARMING DRAWER
OPENING WIDTH
E
5"
(127)
4"
(102)
ALLOW FOR
5/8"OVERLAP
ON ALL SIDES
24"min (610)
CABINET DEPTH
23/8"
(60)
NOTE: Refer to the built-in 30"(762) single oven specifications for electrical location.
91/4"(235)
OPENING
HEIGHT
231/2"min (597)
OPENING DEPTH
273/16"
(691)
24"min
(610)
2"(51) x 2"(51)
ANTI-TIP BLOCK
30-INCH OVEN
ROUGH OPENING
STAINLESS STEEL DRAWER FRONT
INSTALLATION WITH BUILT-IN OVEN
The Wolf warming drawer with stainless steel
drawer front may be installed below or above
a Wolf 30" (762) single oven, provided the
warming drawer is fully enclosed, top and
bottom. Refer to the illustration below and on
page 7. Also refer to installation instructions
provided with the built-in oven for additional
specifications. Dimensions will vary according
to the specific installation.
The Wolf warming drawer is designed and
agency approved for installation with Wolf
built-in ovens. See the label attached to the top
of the warming drawer for approved Wolf
built-in oven models.
The warming drawer platform must be able to
support 175 lbs (79 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
Installation with Built-In Oven – Stainless Steel Drawer Front
IMPORTANT NOTE:
Additional clearance
between warming drawer and oven openings
may be required. Check that oven supports do
not obstruct the interior dimensions required
for the warming drawer.
When the warming drawer is installed below
a built-in oven, a minimum of 2 3/8" (60)
between warming drawer and oven openings
is required for clearance of overlaps. When
installed above a built-in oven, a minimum of
2" (51) is required.
IMPORTANT NOTE:
When the warming
drawer is installed above a built-in oven, a
2" (51) platform with a decorative edge is
required to allow for clearance of overlaps.
STAINLESS STEEL
DRAWER FRONT
Refer to installation
instructions
provided with the
stainless steel
drawer front for
detailed specifica-
tions. These
instructions can
also be found on
the Wolf website,
wolfappliance.com.
7
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
281/2"(724)
WARMING DRAWER
OPENING WIDTH
281/2"(724)
30-INCH OVEN
OPENING WIDTH
5"
(127)
4"
(102)
E
E
271/2"(699)
MICROWAVE
OPENING WIDTH
17"
(432)
20"min
(508)
33" (838)
RECOMMENDED CABINET WIDTH
30"min (762)
23/8"
(60)
91/4"(235)
231/2"min
(597)
273/16"
(691)
11/4"
(32)
24"min
(610)
NOTE: Refer to the built-in 30"(762) single oven specifications for electrical location.
2"(51) x 2"(51)
ANTI-TIP BLOCK
91/4"
(235)
107/8"
(276)
101/4"
(260)
WARMING DRAWER
ROUGH OPENING
3/4"(19) THICK WALL OVEN
SUPPORT PLATFORM
OVEN TRIM EXTENDS 5/16"(8)
BELOW OVEN PLATFORM
OVEN ROUGH OPENING
2" x 2"
ANTI-TIP
BLOCK
FACE RAIL
1/2"
(13)
231/2"
(597)
19/16"
(40)
REVEAL
23/8"
(60)
1/2"
(13)
Installation with Built-In Oven and Microwave – Stainless Steel Drawer Front
STAINLESS STEEL DRAWER FRONT
OPTIONAL INSTALLATIONS
The Wolf warming drawer with stainless steel
drawer front may be installed in combination
with a 30" (762) single oven and microwave
oven with 30" (762) trim, provided the
warming drawer is fully enclosed, top and
bottom. Refer to the illustration below. Also
refer to installation instructions provided with
the built-in oven and microwave for additional
specifications.
The warming drawer platform must be able to
support 175 lbs (79 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
The Wolf warming drawer with stainless steel
drawer front may be installed next to or above
another Wolf warming drawer, provided each
unit is fully enclosed, top and bottom.
Installation with Built-In Oven – Stainless Steel
Drawer Front
OPTIONAL
INSTALLATIONS
Dimensions will
vary according to
the specific
installation.
8
WOLF WARMING DRAWER
INTEGRATED DRAWER FRONT
MODEL WD30
with Integrated Drawer Front
Overall Width 297/8" (759)
Overall Height 101/4" (340)
Overall Depth (behind frame) 231/16" (586)
Minimum Cabinet Width
33" (838)
Minimum Cabinet Depth
26" (660)
Minimum Base Support 175 lbs (79 kg)
Opening Width 2915/16" (760)
Opening Height 10 3/8" (264)
Opening Depth 251/2" (648)
Dimensions may vary to +
–1/8" (3).
2915/16"* (760)
OPENING WIDTH
E
5"
(127)
4"
(102)
251/2"min (648)
OPENING DEPTH
33"min (838)
CABINET WIDTH
26"min (660)
CABINET DEPTH
23/8"
(60)
36" (914)
STANDARD
FLOOR TO
COUNTER
HEIGHT
103/8"*
(264)
OPENING
HEIGHT
2"(51) x 2"(51)
ANTI-TIP BLOCK**
5"min (127)
BOTTOM
OF OPENING
TO FLOOR
*Dimension may vary by +_ 1/8" (3).
**Refer to installation instructions provided with the integrated drawer front (WDFRONT/I) for accurate placement of the anti-tip block.
297/8"(759)
OVERALL WIDTH
231/16"(586)
BEHIND FRAME
9"
(229)
101/4"
(260)
Overall Dimensions – Integrated Drawer Front
Undercounter Installation – Integrated Drawer Front
INSTALLATION SPECIFICATIONS
IMPORTANT NOTE:
If you are installing the
warming drawer with integrated drawer front,
make sure that your cabinetry meets the
minimum 33" (838) width and 26" (660) depth
requirements for this installation. A minimum
base support of 175 lbs (79 kg) is required.
The illustrations below and on the following
pages provide the overall dimensions, finished
rough opening dimensions and electrical
placement for the Wolf warming drawer with
integrated drawer front.
Keep in mind that the width of the custom
panel for the warming drawer with integrated
drawer front will vary according to the specific
installation. The rough opening width will
remain 2915/16" (760) whether installed in
combination with a 30" (762) or 36" (914)
cooktop or oven. The custom panel must be a
minimum of 1/2" (13) thick.
Refer to installation instructions provided with
the integrated drawer front for detailed specifi-
cations. These instructions can also be found
on the Wolf website, wolfappliance.com.
INTEGRATED
DRAWER FRONT
Refer to installation
instructions
provided with the
integrated drawer
front for detailed
specifications.
These instructions
can also be
found on the
Wolf website,
wolfappliance.com.
9
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
2915/16"* (760)
OPENING WIDTH
E
5"
(127)
4"
(102)
251/2"min (648)
OPENING DEPTH
33"min (838)
CABINET WIDTH
26"min (660)
CABINET DEPTH
281/2"(724)
23/8"
(60)
273/16"
(691)
24"min
(610)
2"(51) x 2"(51)
ANTI-TIP BLOCK**
30-INCH OVEN
OPENING WIDTH
103/8"*
(264)
OPENING
HEIGHT
*Dimension may vary by +_ 1/8" (3).
**Refer to installation instructions provided with the integrated drawer front (WDFRONT/I) for accurate placement of the anti-tip block.
Installation with Built-In Oven – Integrated Drawer Front
INTEGRATED DRAWER FRONT
UNDERCOUNTER INSTALLATION
IMPORTANT NOTE:
A minimum 33" (838)
wide by 26" (660) deep cabinet is required for
the warming drawer with integrated drawer
front.
For undercounter installations, 231/2" (597)
from the bottom of the warming drawer
opening to the floor is recommended. It must
be installed a minimum of 5" (127) above the
floor or 1" (25) above the toe kick.
The Wolf warming drawer with integrated
drawer front may be installed below a 30"
(762) or 36" (914) wide electric or gas cooktop,
provided the warming drawer is fully enclosed,
top and bottom. Refer to installation instruc-
tions for the cooktop for additional specifica-
tions. Dimensions will vary according to the
specific installation.
INSTALLATION WITH BUILT-IN OVEN
IMPORTANT NOTE:
A minimum 33" (838)
wide by 26" (660) deep cabinet is required for
the warming drawer with integrated drawer
front.
The Wolf warming drawer with integrated
drawer front may be installed below or above
a Wolf 30" (762) or 36" (914) single oven,
provided the warming drawer is fully enclosed,
top and bottom. Refer to the illustration below.
Also refer to installation instructions provided
with the built-in oven for additional specifica-
tions. Dimensions will vary according to the
specific installation.
The Wolf warming drawer is designed and
agency approved for installation with Wolf
built-in ovens. See the label attached to the top
of the warming drawer for approved models.
IMPORTANT
NOTE
A minimum
33" (838) wide by
26" (660) deep
cabinet is required
for the warming
drawer with
integrated drawer
front.
10
WOLF WARMING DRAWER
IMPORTANT NOTE:
When the warming
drawer is installed above a built-in oven, a
2" (51) platform with a decorative edge is
required to allow for clearance of overlaps.
2"(51) x 2"(51)
ANTI-TIP BLOCK**
281/2"(724)
30-INCH OVEN
OPENING WIDTH
28" (711)
MICROWAVE
OPENING WIDTH
5"
(127)
4"
(102)
E
251/2"min
(648)
26"min (660)
CABINET DEPTH
*Dimension may vary by +_ 1/8" (3).
**Refer to installation instructions provided with the integrated drawer front (WDFRONT/I) for accurate placement of the anti-tip block.
NOTE: Refer to the built-in 30"(762) single oven specifications for electrical location.
NOTE: The width of the custom panel for the warming drawer with integrated drawer front will vary according to the specific installation,
but the rough opening width will remain 2915/16" (760).
NOTE: At installation, wood cleats must be added to the opening for the microwave trim.
23/8"
(60)
103/8"*
(264)
24"min
(610)
273/16"
(691)
11/4"
(32)
201/8"min
(511)
1811/16"
(475)
E
5"
(127)
4"
(102)
33"min (838)
CABINET WIDTH
2915/16"* (760)
WARMING DRAWER
OPENING WIDTH
Installation with 30" (762) Built-In Oven and Microwave – Integrated Drawer Front
INTEGRATED DRAWER FRONT
INSTALLATION WITH BUILT-IN OVEN
The warming drawer platform must be able to
support 175 lbs (79 kg). It must be a minimum
of 1" (25) above the toe kick to allow for the
overlap of the warming drawer trim.
IMPORTANT NOTE:
Additional clearance
between warming drawer and oven openings
may be required. Check that oven supports do
not obstruct the interior dimensions required
for the warming drawer.
When the warming drawer is installed below
a built-in oven, a minimum of 2 3/8" (60)
between warming drawer and oven openings
is required for clearance of overlaps. When
installed above a built-in oven, a minimum of
2" (51) is required.
INTEGRATED
DRAWER FRONT
Refer to installation
instructions
provided with the
integrated drawer
front for detailed
specifications.
These instructions
can also be
found on the
Wolf website,
wolfappliance.com.