REXROTH IndraControl VDP 16.3 User manual

Operating Instructions
Electric Drives
and Controls Pneumatics Service
Linear Motion and
Assembly Technologies
Hydraulics
Rexroth IndraControl
VDP 16.3, VDP 40.3, VDP 60.3
Operator Display
R911336378
Edition 03

Bosch Rexroth AG VDP 16.3, VDP 40.3, VDP 60.3
Record of Revision
Edition Release Date Notes
First edition 06.2012 --
Edition 02 07.2012 Revision
Edition 03 04.2014 Supplementations,
corrections
Copyright
© Bosch Rexroth AG 2014
This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of Bosch Rexroth AG. It may not be repro-
duced or given to third parties without its consent.
Liability
The specified data is intended for product description purposes only and shall
not be deemed to be a guaranteed characteristic unless expressly stipulated in
the contract. All rights are reserved with respect to the content of this docu-
mentation and the availability of the product.
Editorial Department
Development automation systems control hardware HB (KaWa/PiGe)
RS-5cad7220b27ffcb40a6846a00166fdae-3-en-US-4

Table of Contents Page
1 About this Documentation..................................................................... 1
2 Product Identification and Scope of Delivery........................................ 2
2.1 Product Identification............................................................................ 2
2.2 Scope of Delivery................................................................................... 3
3 Using the Safety Instructions................................................................. 3
3.1 Safety Instructions – Structure.............................................................. 3
3.2 Explaining Signal Words and Safety Alert Symbol................................. 4
3.3 Symbols Used........................................................................................ 5
4 Intended Use.......................................................................................... 5
5 Spare Parts, Accessories and Wear Parts.............................................. 6
5.1 Y-Repeater............................................................................................. 6
5.2 External 24 V Power Supply Unit .......................................................... 6
5.3 Uninterruptible Power Supply (UPS)..................................................... 6
5.4 Connecting Cables for the CDI Interface............................................... 6
5.5 Connecting Cables for the USB Interface.............................................. 7
5.6 USB Cables with Increased Noise Immunity.......................................... 7
5.7 Wear Parts............................................................................................. 8
6 Ambient Conditions............................................................................... 8
7 Technical Data....................................................................................... 9
8 Standards............................................................................................ 11
8.1 Used Standards................................................................................... 11
8.2 CE Marking........................................................................................... 12
8.2.1 Declaration of Conformity .................................................................. 12
8.3 UL/CSA Certified................................................................................. 12
9 Interfaces............................................................................................. 13
9.1 View..................................................................................................... 13
9.2 Overview.............................................................................................. 13
9.3 DC 24 V Voltage Supply....................................................................... 14
9.4 S1 DIP Switch...................................................................................... 15
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Table of Contents
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P I

Page
9.4.1 Overview.............................................................................................. 15
9.5 USB Interfaces..................................................................................... 15
9.6 XSER Interfaces and XVID Interfaces................................................... 16
10 Assembly, Disassembly and Electrical Installation.............................. 16
10.1 Installation Notes................................................................................. 16
10.2 Housing Dimensions............................................................................ 17
10.2.1 IndraControl VDP 16.3......................................................................... 17
10.2.2 IndraControl VDP 40.3......................................................................... 20
10.2.3 IndraControl VDP 60.3......................................................................... 23
10.3 Mounting Cut-out................................................................................. 25
10.4 Mounting Dimensions VDP 16.3........................................................... 27
10.5 Mounting Dimensions VDP 40.3........................................................... 28
10.6 Mounting Dimensions VDP 60.3........................................................... 29
10.7 Disassembly......................................................................................... 29
10.8 Electrical Wiring................................................................................... 30
10.8.1 Wiring................................................................................................... 30
10.8.2 Connecting the Control Cabinet PC to Operating Display................... 34
10.8.3 Connecting the Operating Display to the 24 V Voltage Supply............ 36
10.8.4 Connection Scheme – Power Supply Unit, UPS, Control Cabinet PC
and Operating Display......................................................................... 37
11 Commissioning.................................................................................... 37
12 Device Description............................................................................... 38
12.1 General Information............................................................................. 38
12.2 Membrane Keyboard............................................................................ 38
12.2.1 System Requirements.......................................................................... 38
12.2.2 VDP 16.3 Keys and VDP 40.3 Keys....................................................... 39
12.3 Operating and Error Displays............................................................... 40
12.4 Y-Repeater........................................................................................... 41
13 Error Causes and Elimination.............................................................. 41
14 Maintenance........................................................................................ 42
14.1 General Information............................................................................. 42
14.2 Tightening torques............................................................................... 42
14.3 Display................................................................................................. 42
14.3.1 General Information............................................................................. 42
Bosch Rexroth AG
Table of Contents VDP 16.3, VDP 40.3, VDP 60.3
II DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

Page
14.3.2 Backlight Switch-Off............................................................................ 43
14.4 Cleaning Notes..................................................................................... 44
14.5 Regular Maintenance Tasks................................................................. 44
15 Ordering Information........................................................................... 44
15.1 Accessories and Spare Parts............................................................... 44
15.2 VDP 16.3.............................................................................................. 45
15.3 VDP 40.3.............................................................................................. 46
15.4 VDP 60.3.............................................................................................. 47
16 Disposal............................................................................................... 47
16.1 Take-Back............................................................................................. 47
16.2 Packaging............................................................................................. 48
17 Service and Support............................................................................ 48
Index.................................................................................................... 49
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Table of Contents
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P III

Bosch Rexroth AG VDP 16.3, VDP 40.3, VDP 60.3
IV DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

1 About this Documentation
Overview – target groups and product phases
The activities, product phases and target groups that refer to the present docu-
mentation are marked in red color in the following figure.
Example: In the product phase "Mounting (assembly/installation)", the "mechan-
ic/electrician" can execute the activity "install" using this documentation.
Disposal company
Selection Operation
Engineering Commissioning De-
commissioning
To test
To optimize
To create
the NC program
To remove
faults
To maintain
To operate
To simulate
To configure
To program
To parameterize
To install
To mount
To unpack
To construct
To design
To prepare
To select
Design engineer
Mechanic/
electrician)
Process
specialist
Machine
operator
Service
Presales Aftersales
Programmer
Technologist
Product
phases
Target
groups
Activities
Mounting
(assembly/installation)
Programmer
Mechanic/
electrician
To dismount
To dispose
Commissioning engineer
Technologist
Process specialist
Maintenance
technician
Fig. 1-1: Assigning the present documentation to the target groups, product phases and ac-
tivities of the target group
Purpose
This document instructs the technical staff of the machine manufacturer on how
to perform the mechanic and electrical installation in a safe way and on how to
commission the device.
Required qualifications: Individual who is able to assess the tasks assigned and
identify possible safety risks owing to qualification in the subject, knowledge
and experience. The individual should also be familiar with the standards and
regulations.
Scope
This document is valid for all variants, whose type designation code starts with
"VDPxx.3…" and do not contain "…CG…".
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
About this Documentation
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P 1/53

The type designation code specifications are located on the type plate of the de-
vice, see also chapter 2.1 "Product Identification" on page 2.
Further documents
Title Partnumberanddocumenttype
RexrothIndraControl
VAP01
PowerSupplyUnit
R911339613
OperatingInstructions
RexrothIndraControl
VAU01.1
UPSwithCommunicationInterface
R911336867
OperatingInstructions
RexrothIndraControl
VAC01
Y-Repeater
R911336973
OperatingInstructions
RexrothIndraControl
VDevices
OperatingSystems
R911343901
ProjectPlanningManual
Tab. 1-1: Required and supplementing documentation
Customer feedback
Customer requests, comments or suggestions for improvement are of great im-
portance to us. Please email your feedback on the documentations to Feed-
[email protected]. Directly insert comments in the elec-
tronic PDF document and send the PDF file to Bosch Rexroth.
2 Product Identification and Scope of Delivery
2.1 Product Identification
The type plate is located on the rear panel.
Bosch Rexroth AG
Product Identification and Scope of Delivery VDP 16.3, VDP 40.3, VDP 60.3
2/53 DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

Bosch Rexroth AG D-64711 Erbach
Made in Germany
MA6/210-7402-M
U
N
IN 3AC 230V 50/60 Hz
I
N
OUT 10/7,5/5/5/1,5/1,5 A max.
I-C-B-T-V
SW-Version V0,002
MNR: 1070086300 -105 04W03
1070
SN: 123456789
13026
2
3
6
7
7
10
11
12
13
14
9
8
5
4
1
Bosch rexroth Electric Drives and Controls GmbH
D-64711 Erbach Made in Germany
BTV40.1AHB-256S-P5C-
UN-FW
UNIN 3AC 230V 50760Hz
IN
OUT 10/7,5/5/5/1,5/1,5A max.
I-C-B-T-V
SW-Version V0,002
MNR:1070170021 -101 03W19
7261
IND.CONT.EQ 17YB
SN: 123456814
15
16
MadeinGermany
UN: AC 230V / 115V
IN: 0,7A/ 1,4A
MNR: 1070086255 -101 V-Nr: 1
TYP: PCPNL PEN400J1287 IS110-T
Bosch Rexroth Electric Drives and Controls GmbH
D-64711 Erbach
SN: 004012652
7261
IND.CONT-EQ 17YB
XXXXXXXXXXXXXXXXX
I-C-B-H-T-V
FD: 05W01
123
4
8
9
5
10
6
12
11 13
14
15
16
1Logotype
2Division or plant number
3Type code (type designation code)
4Parts number
5State of revision
6Date of manufacture (yyWww)
7Nominal voltage
8Nominal current
9Test marking
10 Version number
11 CE marking
12 Underwriters Laboratories Inc. mark
13 Serial number as barcode
14 Serial number
15 Designation of origin
16 Company address
Fig. 2-1: Type plates, example
2.2 Scope of Delivery
●Operator Display
●Safety instructions
●Mounting kit
●24 V female connector strip
3 Using the Safety Instructions
3.1 Safety Instructions – Structure
The safety instructions are structured as follows:
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Using the Safety Instructions
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P 3/53

Burns and chemical burns due to wrong
battery treatment!
CAUTION
Safety alert symbol
Signal word Consequences and
source of danger
Avoiding danger
Do not open the batteries and do not heat them over 80 °C.
Fig. 3-1: Safety instructions – Structure
3.2 Explaining Signal Words and Safety Alert Symbol
The safety instructions in this documentation contain specific signal words (dan-
ger, warning, caution, notice) and, if necessary, a safety alert symbol (according
to ANSI Z535.6-2006).
The signal word is meant to draw the reader's attention to the safety instruction
and signifies the degree of danger.
The safety alert symbol (a triangle with an exclamation point), which precedes
the signal words danger,warning and caution is used to alert the reader to per-
sonal injury hazards.
DANGER
In case of non-compliance with this safety instruction, death or serious injury
will occur.
WARNING
In case of non-compliance with this safety instruction, death or serious injury
can occur.
CAUTION
In case of non-compliance with this safety instruction, minor or moderate injury
could occur.
NOTICE
In case of non-compliance with this safety instruction, property damage could
occur.
Bosch Rexroth AG
Using the Safety Instructions VDP 16.3, VDP 40.3, VDP 60.3
4/53 DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

3.3 Symbols Used
Notes are displayed as follows:
This is a note.
Tips are displayed as follows:
This is a tip.
4 Intended Use
The Bosch Rexroth operator terminals are passive operation and visualization
terminals. They form a PC-based operator terminal when used with a Bosch
Rexroth control cabinet PC.
Danger of destruction of the device if not ex-
pressly stated accessories, mounting parts and
other components, cables, lines, software and
firmware are used.
NOTICE
The operator displays may be used only as intended and with the accessories,
mounting parts and other components specified in this documentation. Compo-
nents that are not expressly mentioned must neither be attached nor connec-
ted. The same applies to cables and lines.
Operation must only be carried out with the hardware component configura-
tions and combinations that are expressly specified and with the software and
firmware indicated and specified in the respective documentation and function-
al descriptions.
Typical areas of application of the operator displays are:
●Handling systems and assembly systems
●Packaging and food processing machines
●Printing machines and paper converting machines
●Machine tools
●Wood processing machines
The operator displays may only be operated under the mounting and installation
conditions, the position, and the ambient conditions (temperature, degree of
protection, humidity, EMC etc.) specified in this documentation.
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Intended Use
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P 5/53

Risk of destroying the touch screen or the front
panel by using inappropriate items.
NOTICE
Operate the touch screen only with your finger or with a special touch pen
(parts number 1070923266).
5 Spare Parts, Accessories and Wear Parts
5.1 Y-Repeater
Connecting unit to connect two operator displays featuring the same resolution
and the same version to one control cabinet PC.
Orderingcode Partnumber Description
VAC01.1S-YD1-NNNN R911171187 Y-repeaterforCDIinterface
Tab. 5-1: Y-Repeater
5.2 External 24 V Power Supply Unit
Orderingcode Partnumber Description
VAP01.1H-W23-024-010-NN R911171065 External24Vpowersupplyunitforthe
IndraControlVdevices
Tab. 5-2: External 24 V power supply unit for the operator display
5.3 Uninterruptible Power Supply (UPS)
Orderingcode Partnumber Description
VAU01.1U-024-024-240-NN R911171024 Uninterruptiblepowersupply
DC24V,240wattswithUSBinterface
Tab. 5-3: Uninterruptible power supply (UPS)
5.4 Connecting Cables for the CDI Interface
Malfunctions caused by using inappropriate CDI cables.
Use only cables listed in the following overview.
Orderingcode Partnumber Description
RKB0008/000,5(*******-*******-*******) R911171484 Length0.5m
RKB0008/001,0(*******-*******-*******) R911171485 Length1m
RKB0008/002,5(*******-*******-*******) R911170151 Length2.5m
RKB0008/005,0(*******-*******-*******) R911170152 Length:5m
Bosch Rexroth AG
Spare Parts, Accessories and Wear Parts VDP 16.3, VDP 40.3, VDP 60.3
6/53 DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

Orderingcode Partnumber Description
RKB0008/010,0(*******-*******-*******) R911170153 Length10m
RKB0008/015,0(*******-*******-*******) R911171183 Length15m
RKB0008/020,0(*******-*******-*******) R911171184 Length20m
RKB0008/025,0(*******-*******-*******) R911170154 Length25m
RKB0008/030,0(*******-*******-*******) R911171381 Length30m
RKB0008/035,0(*******-*******-*******) R911171369 Length35m
RKB0008/040,0(*******-*******-*******) R911171382 Length40m
RKB0008/050,0(*******-*******-*******) R911171383 Length50m
Tab. 5-4: Connecting cables to control cabinet PC, panel PC and operator display
Further cable lengths are available on request.
Two cables are always required to establish a connection between
the VxB and the VDP.
5.5 Connecting Cables for the USB Interface
Orderingcode Partnumber Description
RKB0019/000,5(*******-*******-*******) R911171165 USBconnectingcable,
Length0.5m
RKB0019/001,0(*******-*******-*******) R911171166 USBconnectingcable,
Length1m
RKB0019/003,0(*******-*******-*******) R911171167 USBconnectingcable,
Length3m
RKB0019/005,0(*******-*******-*******) R911171168 USBconnectingcable,
Length5m
Tab. 5-5: Connecting cables to the control cabinet PC
5.6 USB Cables with Increased Noise Immunity
If the UPS is used in noisy environment, mal-
functions are possible.
NOTICE
Use only USB cables with high noise immunity for the connection between con-
trol cabinet PC and uninterruptible power supply (VAU 01.1 U) with communica-
tion interface.
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Spare Parts, Accessories and Wear Parts
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P 7/53

Orderingcode Partnumber Description
RKB0050/001,0 R911172944 USBconnectingcablewithincreasednoise
immunity;length1m
RKB0050/003,0 R911172945 USBconnectingcablewithincreasednoise
immunity;length3m
Tab. 5-6: Noise immune connecting cable control cabinet PC and UPS
5.7 Wear Parts
Wear parts are not subject to any warranty.
Backlight
The service life of the backlight is limited. After this time has been exceeded,
the backlight will produce only 50 % of its original brightness. The service life is
approx. 50,000 hours at an ambient temperature of 25 °C.
6 Ambient Conditions
Inoperation Transport Storage
Max.ambienttempera-
ture +5℃to+45℃-20℃to+60℃
Max.temperaturegradi-
ent Temporaltemperaturechangesupto3Kperminute
Humidity Min.relativehumidity:
5%
Max.relativehumidity:
85%
Min.absolutehumidity:
1g/m3
Max.absolutehumidity:
25g/m3
Condensationnotal-
lowed
Correspondstoclimatic
class3K3acc.toEN
60721-3-3
Min.relativehumidity:
5%
Max.relativehumidity:
75%
Min.absolutehumidity:
1g/m3
Max.absolutehumidity:
25g/m3
Condensationnotal-
lowed
Correspondstoclimatic
class2K2acc.toEN
60721-3-2
Min.relativehumidity:
5%
Max.relativehumidity:
85%
Min.absolutehumidity:
1g/m3
Max.absolutehumidity:
25g/m3
Condensationnotal-
lowed
Correspondstoclimatic
class1K2acc.toEN
60721-3-1
Airpressure Upto3000mabovesea
levelacc.toEN
61131-2
Bosch Rexroth AG
Ambient Conditions VDP 16.3, VDP 40.3, VDP 60.3
8/53 DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

Inoperation Transport Storage
Mechanicalstrength Max.vibration:
Frequencyrange:10Hz
to150Hz
Excursion:0.075mmat
10Hzto57Hz
Acceleration:1gat
57Hzto150Hz
acc.toEN600068-2-6
Max.shock:
15g11ms
acc.toEN60068-2-27,
nodisturbanceofthe
function
Max.shock:
15g11ms
acc.toEN60068-2-27,
nodisturbanceofthe
function
Contaminationlevel 2
Overvoltagecategory 2 -
Tab. 6-1: Ambient conditions
7 Technical Data
VDP16.3DB VDP16.3AK VDP16.3BK
Display 305mmTFT(12"),800x600pixels,16.7millioncolors
Operation Touchscreenoperation Keyoperation
Surface−frontpanel ColorRAL7035
Lightgray Graphitegray
(Boschdesign) ColorRAL7035
Lightgray
Enclosurerating FrontpanelIP65accordingtoDINEN60529
Fronttype1accordingtoNEMA(UL)
RearpanelIP20
Interfaceonthefront
panel USBconnection,
Coverdegreeofprotec-
tionIP65
NoUSB USBconnection,
Coverdegreeofprotec-
tionIP65
Voltagesupply DC24V(usea24VpowersupplyunitaccordingtoDINEN60742,classifi-
cationVDE0551,forexamplethepowersupplyunitVAP01.1H-
W23-024-010-NN,partnumberR911171065)
Currentconsumption 0.85A
Powerloss 20W
USB PerUSBportmax.500mA,totalcurrentatallUSBportsismax.1A
Weight 4.0kg
Tab. 7-1: Technical data of the VDP 16.3
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Technical Data
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P 9/53

VDP40.3DE VDP40.3BI VDP40.3DF
Display 381mmTFT(15"),1024x768pixels,16.7millioncolors
Surface−frontpanel ColorRAL7035
Lightgray
Operation Touchscreenoperation Keyoperation Touchscreenandkey
operation
Enclosurerating FrontpanelIP65accordingtoDINEN60529
Fronttype1accordingtoNEMA(UL)
RearpanelIP20
Interfaceonthefront
panel USBport,cover,degreeofprotectionIP65
Voltagesupply DC24V(usea24VpowersupplyunitaccordingtoDINEN60742,classifi-
cationVDE0551,forexamplethepowersupplyunitVAP01.1H-
W23-024-010-NN,partnumberR911171065)
Currentconsumption 1.05A
Powerloss 25W
USB PerUSBportmax.500mA,totalcurrentatallUSBportsismax.1A
Weight 5.8kg
Tab. 7-2: Technical data of the VDP 40.3 (DE, BI, DF)
VDP40.3DI VDP40.3AL
Display 381mmTFT(15"),1024x768pixels,16.7millioncolors
Surface−frontpanel ColorRAL7035
Lightgray Graphitegray
BoschDesign
Operation Touchscreenoperationandswitch-
ingelements Touchscreenoperation
Enclosurerating FrontpanelIP65accordingtoDINEN60529
Fronttype1accordingtoNEMA(UL)
RearpanelIP20
Interfaceonthefront
panel USBport,cover,degreeofprotec-
tionIP65 NoUSB
Voltagesupply DC24V(usea24VpowersupplyunitaccordingtoDINEN60742,classifi-
cationVDE0551,forexamplethepowersupplyunitVAP01.1H-
W23-024-010-NN,partnumberR911171065)
Currentconsumption 1.05A
Powerloss 25W
Bosch Rexroth AG
Technical Data VDP 16.3, VDP 40.3, VDP 60.3
10/53 DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

VDP40.3DI VDP40.3AL
USB PerUSBportmax.500mA,totalcurrentatallUSBportsismax.1A
Weight 5.8kg
Tab. 7-3: Technical data of the VDP 40.3 (DI, AL)
VDP60.3FE
Display 483mmTFT(19"),1280x1024pixels,16.7millioncolors
Operation Touchscreenoperation
Surface−frontpanel ColorRAL7035,lightgray
Enclosurerating FrontpanelIP65accordingtoDINEN60529
Fronttype1accordingtoNEMA(UL)
RearpanelIP20
Interfaceonthefront
panel USBconnection(frontpanel)
CoverdegreeofprotectionIP65
Voltagesupply DC24V(usea24VpowersupplyunitaccordingtoDINEN60742,classifi-
cationVDE0551,forexamplethepowersupplyunitVAP01.1H-
W23-024-010-NN,partnumberR911171065)
Currentconsumption 1.7A
Powerloss 40W
USB PerUSBportmax.500mA,totalcurrentatallUSBportsismax.1A
Weight 7.3kg
Tab. 7-4: Technical data of the VDP 60.3
8 Standards
8.1 Used Standards
Standard Meaning
EN60,204-1 Safetyofmachinery-Electricalequipmentofmachines
EN61,000-6-4 Genericstandards-emissionstandard(industrialenvironments)
EN61,000-6-2 Genericstandards–noiseimmunity(industrialenvironments)
EN61,558-2-6 Transformerfor24Vpowersupplyunit,protectiveseparation
EN60,664-1 OvervoltagecategoryII
EN61,131-2 24Voutputsrequirements
EN61,131-2 24Vcurrentsupplyrequirements
ISO13,850 Safetyofmachinery,EMERGENCYSTOPdevices
EN60529 Degreesofprotection(includinghousingsandinstallationcom-
partments)
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Standards
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P 11/53

Standard Meaning
EN60,068-2-6 Vibrationtest
EN60,068-2-27 Shocktest
EN60721-3-1and
EN60,721-3-3 Climaticclass
Tab. 8-1: Used Standards
8.2 CE Marking
8.2.1 Declaration of Conformity
The electronic products that are described in the present instructions, comply
with the requirements and the target of the following EU directive and with the
following harmonized European standards:
EMC Directive 2004/108/EC
The electronic products described in the present instructions are intended for
use in industrial environments and comply with the following requirements:
Standard Title Edition
DINEN61000-6-4
(VDE0839-6-4) ElectromagneticCompatibility(EMC)
Part:6-4:Genericstandards–emissionstandardforindus-
trialenvironments(IEC61000-6-4:2006)
September2007
DINEN61000-6-2
(VDE0839-6-2) ElectromagneticCompatibility(EMC)
Part:6-2:Genericstandards–noiseimmunityforindustrial
environments(IEC61000-6-2:2005)
March2006
Tab. 8-2: Standards for electromagnetic compatibility (EMC)
Non-compliance with CE conformity due to modifications to the de-
vice.
The CE marking is only valid for the device in its delivery status. Af-
ter having modified the device, the CE conformity is to be verified.
8.3 UL/CSA Certified
The devices are certified according to
●UL508 (Industrial Control Equipment) and
●C22.2 No. 142-M1987 (CSA)
Bosch Rexroth AG
Standards VDP 16.3, VDP 40.3, VDP 60.3
12/53 DOK-SUPPL*-VDP*XX.3***-IT03-EN-P

UL file no. E210730
However, there can be combinations or extension stages with limited or missing
certification. Thus, verify the registration according to the UL marking on the de-
vice.
Loss of UL/CSA conformity due to modifications to the device.
The UL and CSA marking is only valid for the device in its delivery
status. After modifying the device, the UL and CSA conformity is to
be verified.
9 Interfaces
9.1 View
S1
XVID XSER XUSB1/2 XUSB3/4 XUSBIN
X1S1
NC
GND 24V
+24V
Fig. 9-1: Interfaces on the operating display
9.2 Overview
Designationat
thehousing Connectiontype Connectortype,integra-
ted Matingconnectororca-
ble(fromoutside)
X1S1 DC-24-Vvoltagesupply 3-pin,MC1,5/3-
G-3,5THT 3-pin,FK-MCP1,5/3-
ST-3,5
XUSB1/2 2USBinterfaces USBfemaleconnector,
TypeA USBconnector,
TypeA
XUSB3/4 2USBinterfaces USBfemaleconnector,
TypeA USBconnector,
TypeA
XSER CDIinterface,data RJ45femaleconnector RJ45connector
XVID CDIinterface,screen RJ45femaleconnector RJ45connector
VDP 16.3, VDP 40.3, VDP 60.3 Bosch Rexroth AG
Interfaces
DOK-SUPPL*-VDP*XX.3***-IT03-EN-P 13/53

Designationat
thehousing Connectiontype Connectortype,integra-
ted Matingconnectororca-
ble(fromoutside)
XUSBIN USB2.0connectiontothecontrol
cabinetPC.Length5mmax.
Useonlyahigh-speedUSB2.0ca-
ble(seechapter5 "SpareParts,
AccessoriesandWearParts"on
page6)
USBfemaleconnector,
TypeB USBconnector,
TypeB
Functionalearthground(FE) M5 Ringcablelug
Tab. 9-1: Interfaces
Malfunctions due to insufficient shielding!
NOTICE
Use only shielded cables and metallic or conductive connector/coupling covers
with large-area shield support.
9.3 DC 24 V Voltage Supply
Fig. 9-2: Interface for 24 V voltage supply
Pin Function
1 Supplyvoltage+24V
2 Supplyvoltage0V
3 n.c.
Use a 24 V industrial power supply unit acc. to DIN EN 60742, classification VDE
0551, for example "VAP01.1H-W23-024-010-NN" (parts number R911171065) for
the voltage supply.
For wiring connection terminals use copper wire only.
Bosch Rexroth AG
Interfaces VDP 16.3, VDP 40.3, VDP 60.3
14/53 DOK-SUPPL*-VDP*XX.3***-IT03-EN-P
This manual suits for next models
2
Table of contents