Rhaon ICL-R User manual

Digitally Steerable Line Array Loudspeaker Systems
IC Live
ICL-R & IC215S-R
USERS MANUAL
Version 1.6.4

IC Live Users Manual - Models ICL-R & IC215S-R
2
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions
5. Do not use this apparatus near water. The apparatus shall
liquids, such as vases, shall be placed on it.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with
the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat
produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-
type plug. A polarized plug has two blades with one wider than the
other. A grounding type plug has two blades and a third grounding
prong. The wide blade or the third prong is provided for your safety.
-
cian for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point where
they exit from the apparatus.
11. Make sure the power cord remains readily accessible at all
times.
12. The AC Power Cord is the AC Mains disconnect.
-
turer.
14. Disconnect this apparatus during lightning storms or when
unused for long periods of time.
required when the apparatus has been damaged in any way, such
as power-supply cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
“WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR
MOISTURE”
“CAUTION: THESE SERVICING INSTRUCTIONS ARE FOR USE
BY QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE
RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVIC-
ING OTHER THAN THAT CONTAINED IN THE OPERATING
INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO”.
CAUTION
To reiterate the above warnings: servicing instructions are for
use by qualified personnel only. To avoid electric shock, do
not perform any servicing other than that contained in the Ope-
ration Instructions unless you are qualified to do so. Refer all
servicing to qualified personnel.
Eindrigliche Warnung: Wartungsvorschriften dienen nur der
Benutzung durch qualifizieres Personal. Zur Vermeidung eines
elektrischen Schlages keine anderen als die in den Betriebsvor-
schriften beschriebenen Wartungsarbeiten ausführen, es sei denn
Sie sind dafür qualifiziert. Wartungsarbeiten auszuführen.
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to
alert the use to the presence of uninsulated
"Dangerous Voltage" within the product's en-
closure that may be of sufficient magnitude
to constitute a risk of electric shock to hu-
mans.
The exclamanation point, within an equilateral
presence of important operating and mainte-
nance (servicing) instructions in the literature
accompanying the product.
VORSICHT
RISK OF ELECTRONIC SHOCK:
OPEN ONLY IF QUALIFIED AS
SERVICE PERSONNEL
GEFAHR EINES ELEKTRISCHEN SCHLAGES:
NUR VON QUALIFIZIEREM WARTUNGSPERSONAL
ZU ÖFFNEN
Der Blitz mit nach untenzielendem Pfeil in
einem gleichseitigen Dreieck weist den
Benutzer auf das Vorhandensein einer
unisolierten, "gefährlichen Spannung" im
Gehäuse hin, die stark genug sein kann, einer
Person einen gefährlichen elektrischen Schlag
zu versetzen.
Das Ausrufezeichen in einem gleichseitigen
Dreieck weist den Benutzer auf wichtige
Betriebs- und Wartungsvorschriften in den
beiliegenden Unterlagen des Gerätes hin.
Erklärung der graphischen SymboleExplanation of Graphical Symbols
IMPORTANT
Your Iconyx Steerable Column Loudspeaker contains no user-serviceable

IC Live Users Manual - Models ICL-R & IC215S-R
3
TABLE OF CONTENTS
Page
Section 1: Basic Operating Instructions
Introduction, Technical Support, General Information 4
Setup & Assembly Instructions 5
Assembly 6
Wiring Diagrams 8
With PC Control 9
Array Input / Power Connections 10
Operation (with no PC) 11
Presets 11
Operation (Computer Controlled) 14
Assigning Digital & Analog Inputs 16
Panel Controls 19
` Section 2: Additional User Information
Initial Setup 22
Computer Requirements 22
Virtual Systems 25
Beam Steering 30
All Loudspeakers / Group Controls 39
Copy Settings / Copy Presets / Reset Control 41
Supervise Mode 42
General Preferences 45
Password Protection 46
Keeping Your RHAON Program Up-To-Date 48
Servicing / Trouble Shooting Hints 54
IC L-R Array 62
Index 66

IC Live Users Manual - Models ICL-R & IC215S-R
4
INTRODUCTION
enjoy it.
Your IC Live digitally steerable column loudspeaker was carefully tested and inspected before leaving our factory and should have arrived
found, immediately notify the shipping company. Only you, the consignee, may institute a claim with the carrier for any damage incurred
and packing material even though the loudspeaker arrived in good condition. If you should ever need to ship the loudspeaker, it should be
shipped in its original factory packaging.
TECHNICAL SUPPORT
-
http://www.renkus-heinz.com/support/request-info/tech-info/i
General Information
and sizes, are easy to transport and setup, and deliver superior sound in a broad spectrum of environments.
Thanks to digitally controlled beam steering they deliver narrow vertical beams of sonic energy that can be directed onto the audience
instead of reverberating off the walls and ceilings. Horizontal coverage is a consistent 150o eliminating the need for left and right setups in
This guide was written to assist you in setting up and operating IC Live systems.

IC Live Users Manual - Models ICL-R & IC215S-R
5
Common Setups
were designed to work together, both acoustically and mechani-
cally with the subwoofer supplying both the extra bass impact
needed by most musical productions and a solid mounting base
for the tall slender columns. Together, the two building blocks
The unique interlocking hardware system with Quik-Release pins
joins the line array and the subwoofer together into a rigid as-
sembly, allowing the subwoofers to be used as mounting bases
for the columns. When used as a mounting base, the subwoof-
ICL-R arrays perform best when their acoustic center, the point
of origination for the narrow acoustic beam, is several feet above
the ear level of the audience. If it’s placed lower, too much of
never reaches those in the rear. If it’s placed much higher, the
narrow vertical beam tends to” light up” the center of the audi-
ence and drop off in both the front and rear.
This puts the ideal height for the bottom of an ICL-R array at
-
subwoofer an ideal arrangement for many setups.
work well when space is available for them on the stage. Mount-
ing two stacked arrays on a single subwoofer is not recommend-
ed, as the assembly is unstable.
Dual subwoofer assemblies combined with either a single ICL-R
array or with two stacked ICL-R arrays are two other popular
-
demanding musical events.
ICL-R and a much higher output level. They are especially
desirable in reverberant rooms where tight control of the beam is
needed to deliver clear speech over a considerable distance.
When only speech is involved and the bass support provided by
the subwoofers is not needed, single or stacked ICL-R arrays
are an ideal solution. They can be attached to the truss work with
Chesebrough clamps or by removing the array’s rear pole/handle
and using the pole clamps to secure the array to the truss.
ICL-R arrays are also equipped with AeroQuip Fly-Track, so they
AeroQuip hardware.

IC Live Users Manual - Models ICL-R & IC215S-R
6
Assembly
IC Live is a building block system designed for easy transportation,
modules:
1.-
ing bars and their short Quik-Release pins from the modules.
2.
module should be turned upside down so the horn sections of the two
modules are together.
3. Align the two modules and then remove the Quik-Release pin from
the upper module’s rear cylinder to allow its inner sleeve to drop
down into the lower module’s rear cylinder.
4. Then re-insert the Quik-Release pin into the upper module’s cylin-
der to lock the inner sleeve in place.

IC Live Users Manual - Models ICL-R & IC215S-R
7
5.
into the channels as shown.
6. Lock the joining bars into place
with the short Quik-Release pins to
complete the physical assembly.
Assembly
exception. The woofer sections of the second and third modules should be joined together. If in doubt, refer to page 62 for proper module
orientation.
Do not attempt to mount a stacked ICL-R array onto a subwoofer standing vertically. The resulting assembly is unstable.
Master / Slave Settings
The next step is to electrically link the modules together and verify
connections should be made to the Master module.
Plug one end of the short CAT5 linking cable into the lower intercon-
upper socket on the upper module. Then plug one end of the short
AC power cable into the looping power socket on the lower module
and the other end into the power socket on the upper module. Follow
the same procedure to connect a third module, if one is provided.
The next step is to set the two dip switches that identify each module.
dip switches shows the proper setting for a Master module (both
future use.
switches, you will need to turn it off or disconnect it at the source and
then reconnect it before the dip switch settings will take effect. When
properly set the digital readouts will both read 20 in a dual array and
30 in a three module array.
Master

IC Live Users Manual - Models ICL-R & IC215S-R
8
Wiring Diagrams For Basic Setups
IC Live arrays were developed for a wide range of different size and types of venues, including even large multi-array events. They include
remotely located computer and multi-channel digital audio distribution.
When remote computer supervision and control is not needed, IC Live arrays can be treated just like any other self-powered loudspeaker.
below.
Single
ICL-R Array Setup
Stacked (Dual)
ICL-R Array Setup
Stacked (Dual)
ICL-R Array
&
Dual IC215S-R Subwoofer
Setup

IC Live Users Manual - Models ICL-R & IC215S-R
9
System Wiring With PC Control
An Ethernet switch is needed only when there are two or more devices, such as an array and a subwoofer. A stacked array is treated as a
single device since it performs as one even though it has two modules.
adequate for most applications. Managed switches are not required.
converter’s output would plug into one of the Ethernet switch ports.
Single
ICL-R Array Setup
with Computer Control
Stacked (Dual)
ICL-R Array Setup
With Computer Control
Stacked (Dual) ICL-R Array
&
Dual IC215S-R Subwoofer Setup
with Computer Control

IC Live Users Manual - Models ICL-R & IC215S-R
10
ICL-R
Control Panel
Array Connections
Looping AC Power Connector
90/260 V AC Power Connector
Primary Ethernet Input Connector
Preset Controls
Operating Controls
Primary Input &
Looping Output
Primary Ethernet Input Connector
IC215S-R
Input / Control Panel
Mute Controls
Level Controls
IC215S-R
Power Control Panel
Power On / Off AC Power Connector
-

IC Live Users Manual - Models ICL-R & IC215S-R
11
Operation With No PC
be inoperative. Your connections need to be made to the lower Master module. You also need to make sure the CAT5 linking signal cable
and the short AC power cable that links the two modules together are in place.
We’ll start with a system that will be run without a computer.
1.
2. Check the preset digital readout display to make sure the correct preset is selected. On single ICL-R arrays:
Preset 10:
should not be used during normal operation.
Preset 11: is factory installed and locked for small venues needing only a 50 foot
throw
Preset 12: is factory installed and locked for venues needing a 75 foot throw
Preset 13: is factory installed and locked for venues needing a 100 foot throw
Preset 14:
factory and was not locked. It may have been deleted and replaced by a
user installed preset
Presets 15,16, 17, 18 & 19 are set aside for user installed presets.
Preset 20:
should not be used during normal operation.
Preset 21: is factory installed and locked for venues needing a 100 foot throw
Preset 22: is factory installed and locked for venues needing a 125 foot throw
Preset 23: is factory installed and locked for venues needing a 150 foot throw
Preset 24:
factory and was not locked. It may have been deleted and replaced by a user
installed preset
Presets 25,26, 27, 28 & 29 are set aside for user installed presets.
3.
4.
it is selected.
5. Check the setting of the Input Pad. The pad should be inserted if your analog input source has a high output level. When On, a 10 dB
is inserted.
6.
readout will display the level setting in dB. You can also mute the output by pressing the Mute button.
Important: The factory presets do not include any EQ, high or low frequency shelving, delay or compression. These can be
added to the presets using a PC equipped with RHAON. Refer to page 16 for details.

Presets ICL-R
Preset 11
Preset 12
Preset 13
IC Live Users Manual - Models ICL-R & IC215S-R
12

IC Live Users Manual - Models ICL-R & IC215S-R
13
Presets (Stacked ICL-Rs)
Preset 21
areas than a single ICL-R array.
Preset 22
Preset 23

Computer Controlled Operation & Supervision
it. If it doesn’t, turn to page 22 for installation and setup instructions.
left corner of the screen.
-
where it will show up as an Icon.
Double clicking on the Icon will open that array’s Connect Properties
window where you can check or change the array’s input selections.
ICL-R arrays have provisions for two Cobranet input, two analog audio
want is as easy as clicking on the desired radio button.
present. The 10 dB Pad in the Analog 1 input inserts a 10 dB pad into
or to select a new Preset.
-
speaker icons in the work space by adding 4 control buttons. They allow
help you identify it in multi-array setups, mute its output and tell when it
the loudspeaker loses signal.
-
sion window which allows you to see at a glance how the array is
Opening the Control window gives you access to the loudspeakers
Parametric EQ, Compressor and Delay controls.
The usual method of monitoring a multi-array system during a program
red bars indicate a problem has been detected. Double clicking on that
array’s icon will open its supervisory window and provide more details on
the problem.
IC Live Users Manual - Models ICL-R & IC215S-R
14

IC Live Users Manual - Models ICL-R & IC215S-R
15
dows. You may have noticed that the vertical control pane is the same in all three of the Properties windows
A detailed description of the vertical control panel’s features and functions follows.
Status Indicators: The Thermal, Peak and Fail indicators above the output meter provide critical information on the array’s status. The
the loudspeaker is being used close to its rated output. Flashing frequently is a sign that the system volume needs to be turned down. The
Power Button:
actual array.
Listing of the loudspeakers model number.
on and off is an entirely manual operation.
the onset of input clipping. Analog inputs
slider with mouse or by using up/down
settings below -8 dB prevent the loud-
speaker from reaching full output.
with caution.
bar graph.
loudspeaker and listing its location.
Press Wink with Light button to turn the
loudspeaker’s wink light on and off to aid in
identifying the loudspeaker and its location.
Press Wink with Audio to send a Tone
positive values indicate how far the signal
values indicate the amount of headroom
left before the onset of limiting.
Mute button mutes the entire loudspeaker.
the event of a malfunction.
Press Wink with Light button to turn the
Press Wink with Audio to send a Tone
with caution.
Mute button mutes the entire loudspeaker.
the event of a malfunction.
loudspeaker and listing its location.
Firmware on page 52 for more details.

Computer Controlled Operation (continued)
Assigning Digital and Analog Inputs
The larger right portion of the Properties windows vary with the operating mode. The Connect window is divided into an upper light grey
one of the radio buttons.
transmitter.
all other audio inputs are automatically disabled.
IC Live Users Manual - Models ICL-R & IC215S-R
16

IC Live Users Manual - Models ICL-R & IC215S-R
17
Computer Controlled Operation (continued)
DSP Control
Remember, the presets installed at the factory include only beam steering information. They do not include EQ, delay or compression.
Bandwidth, Frequency, etc.
turn the compressor off or to compare the uncompressed output to the compressed output, click the Bypass button. To the right of the com-

IC Live Users Manual - Models ICL-R & IC215S-R
18
Computer selection of Presets is accomplished in the Beams / Presets window.

IC Live Users Manual - Models ICL-R & IC215S-R
19
Load Preset
memory.
-
Controls
Most of the buttons at the bottom of the window provide additional control over Presets.
The Panel Controls serve different functions. Clicking on the Panel Display control will turn the Preset digital readout display on the rear of
the array On and Off. The display is often turned off during a performance to prevent the readout’s red glow from being a distraction. The
and Preset Down push buttons on the array’s control panel. Pressing both of these controls at the same time toggles the readout between
On and Off.
The Panel Buttons control locks all the controls on
the rear of the associated array to prevent inadvertent
changing of the settings or tampering. The padlock ion
will be closed when the controls are locked.
SysTune Interface
system during setup and tuning, you can access the
This allows you to take a measurement, adjust the
EQ settings and then view the result of the changes in
real time within one program and on one screen - - no
more jumping back and forth between programs and
windows.

IC Live Users Manual - Models ICL-R & IC215S-R
20
This manual suits for next models