Ribao CS-600B User manual

COIN SORTER
CS-600B

CS-600B OPERATION MANUAL V1.1
Page 2 of 15
OPERATION MANUAL
Content
Introduction........................................................................................................................ 3
Specifications..................................................................................................................... 4
Key Panel.............................................................................................................................. 5
Precautions..........................................................................................................................6
Operating Procedures................................................................................................... 7
Set up the Coin Bag Holder & Coin Tube Holder(Option)...................... 11
Troubleshooting..............................................................................................................12
Daily Maintenance......................................................................................................... 14
Accessories........................................................................................................................ 14

CS-600B OPERATION MANUAL V1.1
Page 3 of 15
Introduction
CS-600B is the coin sorter with accurate batch function designed
and produced by our company. We adopt high speed, low noise and
high resolution CCD image sensor, ensure to separate different
denomination coins with 0.2mm diameter difference(without wearing)
which ensures more accurate sorting of the coins. CS-600B can sort 6
kinds of coins at the same time. The printer, external display or
computer can be connected through RS-232 socket, all data can be
printed out at any time.
Power Socket
Power Switch
RS232(PC communication)
PS2(External interface)
RS232(printer interface)

CS-600B OPERATION MANUAL V1.1
Page 4 of 15
Specifications
Sorting speed
approx. 600coins/ min
Hopper capacity
approx.600pcs
Coin denomination
diameter 14-33mm
Coin thickness
1-4mm
Sorting number
1-5 different coins
Dimension
510×280×320mm
Weight:
16Kg
Power Consumption
45W
Power Supply
AC 120V ± 10%, 60Hz
or AC 220V ± 10%, 50Hz
Display
8 Digits LCD Display
Ambient Temperature
0-40C°
Humidity
30-75%

CS-600B OPERATION MANUAL V1.1
Page 5 of 15
Key Panel
Key Function:
1)START/STOP:Start and Stop
2)HOME:Back to main interface
3)and :Select the list of different Channels / memory
units
4)CLR:Clear
5)SET:Debug reserve key
6)VALUE/COUNT :To switch the display mode between
quantity and amount
7)BAT:Batch setting
8)MT:Memory
9)MR:Memory Reading
10)M+ :Accumulate the current counted number with
previous data and save

CS-600B OPERATION MANUAL V1.1
Page 6 of 15
11)PRINT:Print the list of quantity、value of coins
12)+1000、+100、+10、+1:Numeric keys
Display modes:
1)Amount display : 0.00, with decimal point;
2)Quantity display: 0, no decimal point;
3)Total display: 0, No Channel number;
4)Single Channel display: 1- 0, With Channel
number“1-”.
Precautions
·Use the power cable and communication cable supplied with this
machine.
·Unplug the machine before moving it.
·Avoid operation under direct sunlight.
·Do not place your head, hand, tools and clothes near the hopper to
avoid injury and malfunction of the machine.
·Don’t open the cover during operation.

CS-600B OPERATION MANUAL V1.1
Page 7 of 15
Operating Procedures
·Turn on the power switch,the display shows the amount as right
picture, with decimal point.
·Press START/STOP to start, the machine
automatically enters into amount
display mode, with decimal point. After
start, the motor rotates and counting
starts.
·In Single channel modes, press 、
key to select different channels. In
Amount display modes, 、keys
are void.
·In single channel modes, press
START/STOP key to return to quantity display and motor rotates and
starts to count.
·Press VAL key to switch between amount
and quantity.
Data clearance:
· In single channel modes, press CLR
to clear the data of this channel only;
·In total mode, press CLR key to clear
all the data

CS-600B OPERATION MANUAL V1.1
Page 8 of 15
Data save:
·Press MT key to save the data and
the indicating lamp is on
·If the indicating lamp is ON, it
means the channel is with data
saved inside;
·In single channel modes, press MT to save the data of this channel
only;
·In total mode, press MT to save the data of all the channels.
Read the memory data:
·In single channel modes, press MR
to read out this channel only;
·In total mode, press MR to read the
total.
Memory Clearance:
·First press CLR key to clear the current data;
·Then press MT to clear data. After data is removed, the indicating
lamp will be OFF.
Accumulation saving:
·Press M+ key to accumulate the
current data with the previously
counted data, then save it and the

CS-600B OPERATION MANUAL V1.1
Page 9 of 15
display is zero.
Similar to data saving procedure:
·In single channel modes, accumulate only the data of this
channel;
·In total mode, accumulate the data in all the channels.
Batch setting:
·Press BAT key to enter into batch
setting mode.
Note :1)After you set the each
channel’s batch number, when the
machine reaches the batch number,
the motor will stop and the display will
show which channel has reached the
batch number, same as the right
picture. It blinks to display the first channel that has reached the
batch number, if the blinking still goes on, it means other channel
may also have reached the batch number. After noting down,
press START/STOPKey, it displays the next channel that reaches.
When there is no other channel reaches the batch quantity, it will
display normally. Press START/STOP Key, the machine starts to
work again.
2)As it is a rail sorter, when batch number is reached, the motor will
stop, but there are still some coins in the passage, and these coins
finally roll into the drawer. The machine will display the actually

CS-600B OPERATION MANUAL V1.1
Page 10 of 15
counted number.
Batch setting procedure:
·Press CLR to clear to Zero;
·+1000、+100、+10、+1 keys are for batch number setting:
①+1000 is 1000, +100 is 100, +10 is 10, +1 is 1;
②One press increase the digit by 1. e.g. press +1 key once is
1, double press is 2;
·Press and to switch channels.
After setting is OK, exit as follows;
·Press BAT key to exit and enter into total quantity display mode;
·Press START/STOP key to exit and enter into standard mode.
Value setting:
·Keep pressing VAL key and turn
on the power to enter into value
setting mode.
·Press CLR key to clear to Zero;
·+1000、+100、+10、+1 keys are for value setting:
①+1000 is 10, +100 is 1, +10 is 0.1, +1 is 0.01;
②One press increase the digit by 1. e.g. press +1 key once is
0.01, double press is 0.02;
·Press and to select different channels.
·After setting, press VAL key to exit and enter total display.

CS-600B OPERATION MANUAL V1.1
Page 11 of 15
Set up the Coin Bag Holder & Coin Tube
Holder(Option)
Install the Coin Bag and fix with the
clip.
Rotate and hang the Coin Tube Holder.
Install the Hook Holder on the
Coin Tube Holder.
According to the denomination of the
coin you will count, please select the
Coin Interior Tube and Paper Tube.
Drop the Coin Interior Tube down into
the Tube Holder.

CS-600B OPERATION MANUAL V1.1
Page 12 of 15
Put the Paper Tube into the Coin
interior Tube and the Paper Tube will
be held by the Hook Holder
According to the coin quantity of each
paper tube, set the batch number (in
batch counting mode), then start
counting. The machine will stop when
the counting number reaches the
batch quantity. All the counted coins
will drop into the Paper Tube, push the
Hook Holder backward, take out the
Paper Tube with all counted coins
inside, then seal the open side of the
paper tube manually.
Troubleshooting
During counting, error may occur and it will display error
information(same as below picture), and motor stops.

CS-600B OPERATION MANUAL V1.1
Page 13 of 15
·When Error1 occurs, it means the front cover welding is open, and
close the front cover welding back to the normal coin counting
procedure.
·When Error2 occurs, it means some coins may be jammed on CIS
sensor , please remove the coins. Press CLR key to return to normal
working status.
·When Error3 occurs, it means some coins may be jammed on the rail,
please remove the coins. Press CLR key to return to normal working
status.
Notes: If foreign object blocks the rail, the coins may not be able to
drop into the correct drawer, thus causing the counting result not
accurate. Therefore, please check and remove all the foreign objects
which are mixed into the coins before sorting.

CS-600B OPERATION MANUAL V1.1
Page 14 of 15
Daily Maintenance
·Be sure to turn the main power off before attempting daily
maintenance.
·Clean the coin rail at least once a day with a brush.
·Clean the disc at least once a day with a brush.
·If the machine needs maintenance or spare parts, please contact
your local distributor.
Accessories
1. Power Cable 1 pc
2. Tray 1pc
3. Nylon Brush 1pc
4. Cotton Bag 2pcs
5. Coin Tube Set 2 sets
6. Tube Holder 1pc(Optional)
7. Coin Interior Tube(for US coins) 1set(4pcs)(Optional)
8. Hook Holder 1pc(Optional)
9. Printer 1pc(Optional)

CS-600B OPERATION MANUAL V1.1
Page 15 of 15
*** In the interests of our ongoing policy of continual product
improvement, specifications are subject to change without prior
notice. ***
Table of contents
Other Ribao Cash Counter & Coin Sorter manuals
Popular Cash Counter & Coin Sorter manuals by other brands

NRI
NRI G-18.mft operating instructions

Ditron
Ditron SAFEMONEY Compact user manual

ratiotec
ratiotec Soldi Smart Series instruction manual

Suzohapp
Suzohapp Comestero Cinco operating manual

MEI
MEI Cashf low SC83 Installation & operation manual

TSI Instruments
TSI Instruments AEROTRAK 8240 Operation and service manual