Rico Beam 230 User manual

Beam 7R Moving Light
User Manual
Please read this user manual before using this product.

2
INDEX
STATEMENT 3
ACCESSORIES 3
SAFETY INSTRUCTION 3
GENERAL GUIDELINES 4
INSTALLATION 6
TECHNICAL SPECIFICATION 9
CONTROL SYSTEM 10
PANEL OPERATION 11
CHANNEL DESCRIPTION: 18
CLEANING AND MAINTENANCE
23

3
STATEMENT
The product has well capability and intact packing when leave
factory. All of the user should comply with warning item and manual, any
misuse cause of the damages are not included in our guarantee, and
also cannot be responsible for any malfunction & problem owing to
ignore the manual.
ACCESSORIES
These items are packed together with the product:
Name
Quantity
Unit
Remark
USER MANUAL
1
PCS
DMX CABLE
1
PCS
POWER CABLE
1
PCS
CLAMP
2
PCS
OMEGA
2
PCS
SAFETY CABLE
1
PCS
SAFETY INSTRUCTION
Please keep this User Guideforfuture consultation. If you sell the unit to another
user, be sure that they also receive this instruction booklet.

4
GENERAL GUIDELINES
NEVER OPEN THIS FIXTURE WHILE IN USE!
During the initial operation of this fixture, a light smoke or smell may emit
from the interior of the fixture. This is a normal process and is caused by
excess paint in the interior of the casing burning off from the heat
associated with the lamp and will decrease gradually over time.
This fixture is a professional lighting effect designed for INDOOR / DRY
LOCATIONS ONLY on stage, in nightclubs, theatres, etc.
Please make sure there are NO FLAMMABLE MATERIALS close to the

5
fixture while operating, to prevent any fire hazard.
The fixture must be installed in a location with adequate ventilation, at least
1.5 feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are
blocked.
DO NOT attempt installation and/or operation without knowledge how to
do so.
DO NOT permit operation by persons who are not qualified to operate this
type of fixture. Most damages are the result of operations by
nonprofessionals. Consistent operational breaks may ensure the fixture will
function properly for many years to come.
DO NOT shake fixture, avoid brute force when installing and/or operating
fixture.
Always install the fixture with an appropriate safety cable. When installing
the fixture in a suspended environment, always use mounting hardware
that is no less than M10 x 25 mm, also be sure the hardware is insert in the
pre-arranged screw holes in the bracket of the fixture.
Use the original packaging and materials to transport the fixture in for
service.
DO NOT TOUCH the housing bare-hand during its operation. Turn OFF
the power and allow approximately 15 minutes for the fixture to cool down
before replacing or serving.

6
INSTALLATION
C A U T I O N S
For added protection, mount the fixture in areas outside walking paths,
seating areas, or in areas were unauthorized personnel might reach the
fixture.
Ambient operating temperature range for this fixture is 5° to 113°F. (-15°
to 45°C) Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area
can hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety
attachment, such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or
servicing.
The unit should be mounted via its screw holes on the bracket. Always ensure
that the unit is firmly fixed to avoid vibration and slipping while operating. And
make sure that the structure to which you are attaching the unit is secure and is
able to support a weight of 10 times of the unit’s weight. Also always use a

7
safety cable that can hold 12 times of the weight of the unit when installing the
fixture.
The equipment must be fixed by professionals. And it must be fixed at a place
where is out of the touch of people.
Clamp mounting
The moving head provides a unique mounting bracket assembly that
integrates the bottom of the base, the included ‘Omega Bracket’ and the
Safety Cable rigging point in one unit (see the illustration below).When
mounting this fixture to truss be sure to sere to secure an appropriately rated
clamp to the included Omega Bracket using a M10 screw fitted through the
center hole of the ‘omega bracket’. As an added safety measure be sure to
attached at least one properly rated Safety Cable to the fixture using one of
the safety cable rigging point integrated in the base assembly.

8
DMX-512 control connection:
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the
other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving
head together through serial linking. The cable needed should be two core, screened cable
with XLR input and output connectors. Please refer to the diagram below.
DMX-512 connection with DMX terminator:
For installations where the DMX cable has to run a long distance or is in an electrically noisy
environment, such as in a discotheque, it is recommended to use a DMX terminator. This
helps in preventing corruption of the digital control signal by electrical noise. The DMX
terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3,which
is then plugged into the output XLR socket of the last fixture in the chain. Please see
illustrations below.

9
TECHNICAL SPECIFICATION
Light Sources: Philips MSD Platinum 5R or Osram 7R ( Color temperature:
8000K)
Power Voltage: AC 100-240V, 50/60Hz
Power Consumption: 350W
Product Size:523×337×511mm
Packing Size: 635X440X725
Net weight:19.5KG
Control
DMX Channel: 16 DMX Channel
Control Modes: DMX-512
Control Signal: DMX512/Master-Slave/Auto run
Pan/Tilt
Pan/Tilt: 540°/ 270°
Pan/Tilt Resolution: 16 bit
Construction
Display: Colorful Touch Screen
Data In/Out socket: 3-pin XLR sockets
Power Socket: Powercon in
Protection Rating: IP20
Two 1/4 turn fastening Omega Clamps
Color wheel: one color wheel, 14 kinds of color chips in one color wheel
Gobo: 17 gobos
Effect Wheel: Rotation eight prism, Rotation vortex , frost.

10
Feature
Amazing dot matrix, four tact switch, 180° turning show
0-100% mechanical dimming, mechanical dimming and free dimming available.
Strobe macro control available.
Lens optical system electric focus .beam angle 0~4°
Over heat protection
Please Note: Specifications and improvements in the design of this unit and this manual are subject
to change without any prior written notice
CONTROL SYSTEM
Th
e
D
M
X512
is
w
id
ely
used
in intellig
ent
ligh
ti
ng
con
tr
ol, with a DMX 512
controller. Connect several lights together dmx in and dmx out,
3
pin
XLR
connectors
:
Pin
1:
G
ND
,
Pin
2:
Nega
tive
s
ign
a
l
(-),
Pin
3:
P
o
s
itive
s
i
gna
l
(+)

11
PANEL OPERATION
Brief
The light panel diagram show as Figure 1, Left area is TFT Displayer, support
touch, and right area is encoder button, both of touch and coder button can
operate light and setting.
Display & operation just like ‘Android operation system’, touch the item will set
or modify setting.
Note: Prevent damage the touch or TFT displayer, Can not use sharp objects
chick displayer.
Figure 1 Panel diagram
Operation
Operate light with touch or encoder button
⚫The left area is TFT Displayer and touch, chick item or value with finger will
to complete operation of set light setting(parameters) or view light state.
⚫The area on the right hand side is rotary encoder with button, As auxiliary
input interface, if disable touch function,, the encoder can been choose
to set or view the item, and then press the encoder button to confirm the
selection, rotary encoder again set the parameter value, finally, Press
encoder button one again to save value or setting.

12
Parameter value setting
When the selected item is value need to been modified, the dialog shown in
Figure 2 will popup.
Figure 2 Dialog of value setting
⚫Modify value:Can quickly modify value via pull the slider to the desired
position, or click the button of ‘up’ or ‘down’ whit finger on the right side to
set the exact desired value, another way is roll encoder on the right hand
side of panel.
⚫Apply value:When Value had been modified, Then press the bottom of
‘apply’ in the left corner to apply to the light, but hav’t saved;
⚫Save Value:Any time, click on the lower right corner of the "OK" button,
the setting will been saved into internal memory.
Boolean parameter setting
⚫when the selected parameters is a Boolean value (such as ON or OFF),
can directly modify setting by chick corresponding item, the setting will
been saved right now.
⚫When the parameter is a key item, chick corresponding item, a dialog
shown in Figure 3 will been popup ask for the confirm. Chick ‘sure’ to
confirm.

13
Figure 3 Dialog of confirm
Sub Menu(Parameter)
Chick item of main menu, enter corresponding sub menu, shown in Figure 4,
total 6 sub menu, includes class of parameter and status:
⚫ADDRESS:Set light DMX address.
⚫WORKMOD:Set light work mode, master or slave mode when in auto run
mode.
⚫DISPLAY: Set display parameter, eg. select language.
⚫TEST:Used for test light, modify DMX channel data to test function, the
corresponding function of reference channel function table.
⚫ADVANCE:Set light running parameter.
⚫STATUS:view light current status.

14
Figure 4 Parameter menu
Operation and parameter instruction
Via following operation, enter sub menu(parameter menu) shown in Figure 4
⚫In main menu, chick 1/6 function button into corresponding parameter
menu.
⚫In sub menu(page), chick main item on the left side of displayer, can shift
to corresponding sub menu(page) quickly.
Set DMX Address
Click and select the "ADDR", can enter the page of DMX address setting, range
from 1 to 512, the address code shouldn’t is not greater than (512- channels
quantity), otherwise the light will not been controlled. Following is the operation:
Enter the page of DMX address, as shown in Figure 5, click the blank area in
right side of display will pop-up diglog as in Fig. 4, modify value, then click
‘ENTER’ to confirm and save DMX address code.
Figure 5 page of DMX Address
Set Light work mode
Enter the page of ‘WORK MOD’ as shown in Figure 6 and modify setting. Can
set light work mode, control lamp and DMX channel mode..

15
Light includes 3 work mode: DMX MODE, AUTO RUN and SOUND MODE,
Parameter definition as following:
⚫DMX Mode :Under this mode, the light receive data from the DMX
controller and move.
⚫AUTO RUN:Under this mode, light will run with inside code(data), ignore
data from DMX controller.
⚫SOUND Ctrl:Under this mode, light ignore data from DMX controller.,
When there is a strong sound in stage, the light will run a scene, otherwise
it will keep the last scene.
⚫M/S Choose:’M/S Choose’ is available when light just in ‘AUTO RUN’ or
‘SOUND Ctrl’ mode. If this item is set as ‘OFF’, the light don’t send data to
other light via DMX Cable. When ‘ON’, the data will send to other slave light
immediately.
⚫Lamp control:Turn on lamp when this item is set ‘ON’, otherwise, turn off
lamp. The gap between operation is limited to 30 second.
⚫Channel mode:Light support 2 DMX Channel mode: sample or extend。
Figure 6 page of work mode
Set display
Light support 2 language, rotation display,Enter page as shown in Figure7 to
set parameter following:
⚫Language:Select display as simplified Chinese or English.

16
⚫Screen Saver:when panel is idle(these is no operation in 10 second),
displayer will enter saver status. When set as ‘mode 1’,saver status is
close display, as ‘mode 2’ saver status will display DMX address code(DMX
MODE) or display LOGO(AUTO RUN or SOUND CTRL). As ‘OFF’, keep
light up displayer and show main menu。
⚫Screen Rotation:rotate displayer.
⚫Touch enable :Disable or enable touch function, when disable, use
encoder to operate light and set parameter.
⚫Touch adjust:adjust touch function, normally, not enter this item.
Figure7 page of display
Test light
Enter the page as shown in Figure 8, Light will into test mode, in this mode, the
light does not receive the data for DMX controller.:
⚫PAN: range for 0 to 255;
⚫TILT: range for 0 to 255;
⚫FOCUS: range for 0 to 255;
⚫COLOR: range for 0 to 255;
⚫GOBO: range for 0 to 255;
⚫PRISM: range for 0 to 255;
⚫FROST: range for 0 to 255;;
⚫STROBE: range for 0 to 255;。

17
Figure 8 page of Test
Set light run parameter
Enter the page as shown in Figure 8, set the parameter of light:
⚫Pan Invert: Reverse PAN move.
⚫Tilt Invert: Reverse TILT mover.
⚫Rectify enable:set as ‘OFF’, PAN or TILT will disable position rectify
function. As ‘ON’, when PAN or TILT lose steps, light will rectify auto.
⚫Pan Offset: Set PAN original position.
⚫Tilt Offset: Set TILT original position.
⚫Lamp up when: Select lamp on mode, includes 3 mode: power on, after
reset done and manual;
⚫Factory setting: restore all parameter to factory setting.

18
Figure 9 page of run parameter
View status
Enter the page as shown in Figure 10:
⚫View light current status, version;
⚫DMXClr: Click to clear all DMX data to ‘0’.
⚫SysRst:Click to reset light.
Figure 10 page of status
CHANNEL DESCRIPTION:
1. COLOR
The light support color halftone color mixing, forward / reverse rainbow effect,
speed adjustable, detailed in Table 1.
Table 1 Detail of color
CH NO.
NAME
VALUE
FUNCTION
CH1
COLOR
0~4
WHITE
5~9
WHITE+COLOR1
10~14
COLOR1
15~19
COLOR1 + COLOR2

19
20~24
COLOR2
25~29
COLOR2 + COLOR3
30~34
COLOR3
35~39
COLOR3 + COLOR4
40~44
COLOR4
45~49
COLOR4 + COLOR5
50~54
COLOR5
55~59
COLOR5 + COLOR6
60~64
COLOR6
65~69
COLOR6 + COLOR7
70~74
COLOR7
75~79
COLOR7 + COLOR8
80~84
COLOR8
85~89
COLOR8 + COLOR9
90~94
COLOR9
95~99
COLOR9 + COLOR10
100~104
COLOR10
105~109
COLOR10 + COLOR11
110~114
COLOR11
115~119
COLOR11 + COLOR12
120~124
COLOR12
125~129
COLOR12 + COLOR13
130~134
COLOR13
135~139
COLOR13 + COLOR14
140~144
COLOR14
145~149
COLOR14 + WHITE
150~199
Rotate forward(Fast -- slow)
200~255
Rotate reverse(Slow -- fast)

20
2. DIMMING & STROBE
The light support multiple strobe mode, as show Table 2 in detail.。
Table 2 detail of strobe
CH NO.
NAME
VALUE
FUNCTION
CH2
STROBE
0~3
Dark
4~103
Slow strobe to fast strobe
104~107
White
108~207
Slow strobe to fast strobe(mode 2)
208~212
white
213~225
Free strobe ,slow
226~238
Free strobe ,middle
239~251
Free strobe ,fast
252~255
White
CH3
DIMMER
0-255
0 ~ 100%
3. GOBO
Lighting GOBO support pattern / anti flow, support pattern shake, soft to the fast
adjustable, see detail is shown in table 3.
Table 3 detail of gobo
CH NO.
NAME
VALUE
FUNCTION
CH4
GOBO
0~2
WHITE
3~5
Gobo1
6~8
Gobo2
9~11
Gobo3
12~14
Gobo4
15~17
Gobo5
18~20
Gobo6
21~23
Gobo7
23~26
Gobo8
Table of contents
Other Rico Dj Equipment manuals
Popular Dj Equipment manuals by other brands

Velleman
Velleman HQ Power HQLP10012 user manual

Everdeck Staging
Everdeck Staging VERSA 750 DECK Assembly manual

Velleman
Velleman HQ-POWER COPERNICUS IV LED MOONFLOWER 469... user manual

Martin
Martin RUSH PAR 3 RGB user manual

Robert Juliat
Robert Juliat ALEX Technical file

ProLights
ProLights JETSPOT-3 user manual