Rockwood 31896 User manual

1/2"PNEUMATIC DRILL
WITH HANDLE
INSTRUCTIONS
Item #31896

2Eastwood Technical Assistance: 800.343.9353 >> techelp@eastwood.com
The ROCKWOOD®1/2” REVERSIBLE PNEUMATIC DRILL WITH HANDLE is ruggedly designed for
many years of reliable service. It features a positive-locking forward/reverse control. A high-torque,
5-vane, ball bearing air motor and a hardened planetary gear set provide smooth operation and long
life. Speed is easily controlled with an infinitely progressive throttled trigger control.
CONTENTS
(1) 1/2” [13mm] Reversible,
Right Angle Drill
(1) Chuck Key
(1) 1/4” MNPT, Male
quick disconnect inlet fitting
(2) Handle
(1) Handle Clamp
SPECIFICATIONS
RPM: 700 free speed
Variable speed, 5 vane, ball bearing air motor
Air Consumption: 7 CFM [198 L/min] @ 90 psi [6.2 bar]
Inlet thread size: 1/4” FNPT
Maximum Chuck Capacity: 1/2” [13mm]

To order parts and supplies: 800.343.9353 >> eastwood.com 3
READ INSTRUCTIONS
• Thoroughly read and understand these product instructions before using
this tool. Failure to follow all warnings can result in tool damage or serious
physical injury.
• Keep these product instructions for future reference.
RESPIRATORY HAZARD!
• Dust and fine particulate matter is generated during the drilling process
which can contain toxic substances such as lead, silica, solvents and
others. Breathing this dust and fine particulate matter can cause many
serious respiratory health conditions. Always use NIOSH approved
respiratory protection while using this Drill.
EYE INJURY HAZARD!
• Rapidly rotating surfaces can eject metal particles, dirt and debris at high
velocity. Always wear ANSI approved eye protection when operating this tool
.
HEARING DAMAGE HAZARD!
• This tool emits high sound levels while operating. Use ANSI approved ear
protection when operating.
BURSTING HAZARD!
• Do not exceed 90 psi (6.2 bar) of tool inlet pressure. Permanent tool damage
and/or explosion could occur and cause personal injury.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION used with the safety alert symbol, indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
NOTICE is used to address practices not related to personal injury.
SAFETY INFORMATION
The following explanations are displayed in this manual, on the labeling, and on all other information
provided with this product:

4Eastwood Technical Assistance: 800.343.9353 >> techelp@eastwood.com
INJURY HAZARD!
• This tool has high-speed, rotating components which can quickly cause severe
injury. Keep fingers and hands away from moving parts when operating. Wear
thick, well-fitting work gloves and keep loose clothing, sleeves, cords, jewelry
and hair away from moving parts.
• This tool could eject sparks at high speed which can ignite flammable materials
or injure others nearby. Do not operate near flammable materials and keep all
persons and pets away from the work area.
• Do not force drill or exert excessive side forces on tool while in use as the drill
body can suddenly kick back or twist causing severe hand or wrist injury.
Drill bits can suddenly break with excessive side force.
• Always make sure the workpiece is securely clamped or anchored to avoid
sudden movements which could result in injury.
• Always disconnect Drill from air supply when changing drill bits or accessories
to prevent accidental tool starting and potential serious injury.
• Frequently inspect Chuck and overall tool condition. If damage is discovered,
discontinue tool use immediately. ONLY use drill bits or accessories rated for
700 RPM or greater use, otherwise serious injury can result in the event of failure.
VIBRATION INJURY HAZARD!
• This Drill will vibrate during use! Repeated exposure to vibration may cause
physical injury.

To order parts and supplies: 800.343.9353 >> eastwood.com 5
SET-UP
• Using a good quality
Teflon sealing tape (not
included), thread the
1/4” MNPT, Male quick
disconnect inlet fitting
into the air inlet.
• Slip the Brass Handle
Clamp over the Chuck
and onto the main
Drill Body.
NOTE: It may be
necessary to spread
the Handle Clamp
slightly to fit it over
the Chuck (FIG 1).
• Compress the thread
portion of the Handle
Clamp together then
thread the Handle onto
the Handle Clamp
(FIG 2).
NOTE: Do not fully
tighten Handle until a
comfortable position is
found for the Handle.
FIG. 1
FIG. 2
Chuck
✓
Handle
Clamp
Slide
✓
✓
Chuck
Key
Handle
Forward
(normal drilling
direction)
Reverse
Trigger
Handle Clamp
✓
✓
✓
✓
✓
✓

6Eastwood Technical Assistance: 800.343.9353 >> techelp@eastwood.com
CONNECTION
• Be sure that the air supply to the tool is clean and dry. Moisture in the supply line will quickly
damage the motor and valves.
• A minimum 3/8” I.D. air line should be used for optimal performance.
OPERATION
• Open the Chuck Jaws by rotating the shell in a Counter-Clockwise direction (as viewed
from the open end).
• Insert drill bit or accessory shank into Chuck Jaws.
• Close the Chuck Jaws by rotating the shell in a Clockwise direction (as viewed from the
open end).
• Insert Chuck Key into one of three bores of the Chuck with the gear teeth engaged and
turn Clockwise to tighten Chuck Jaws (FIG 2).
• Connect air supply, depress Trigger to begin rotating action. Speed is regulated by pressure
applied to the Trigger.
• For forward (normal drill rotation) direction, disconnect from air supply, move Forward/Reverse
Lever fully to the “F” position (FIG 2).
• To reverse drill, disconnect from air supply, move Forward/Reverse Lever fully to the
“R” position.
MAINTENANCE
• Add several drops of air tool oil before each use by dropping directly into the air inlet.
• If tool is to be unused for an extended period, add 10 drops of air tool oil directly to the air inlet,
rotate the tool motor by hand several times to distribute the oil throughout the motor, then store
the tool, handle up.
• With the air supply disconnected, open chuck jaws fully and using a #2 Philips screw driver,
periodically check that the chuck retaining screw is tight. Note: This screw is left-hand
threaded, turn counter-clockwise to tighten.
INJURY HAZARD!
Remove Chuck Key before starting Drill.

To order parts and supplies: 800.343.9353 >> eastwood.com 7
Tool doesn’t re-
spond to trigger
depression
Insufficient vol-
ume of air (CFM)
to operate tool
Verify sufficient air supply to tool.
(7 CFM @ 90 PSI minimum requirement).
Moisture or oth-
er contamination
in air supply
Check for moisture in air line and tool air inlet.
Tool perfor-
mance is slow
or sluggish
Insufficient
volume of
air (CFM) to
operate tool
Verify sufficient air supply to tool.
(7 CFM @ 90 PSI minimum requirement).
Moisture or oth-
er contamination
in air supply
Check for moisture in air line and tool air inlet.
Air Motor
is lacking
lubrication
Stop use immediately and add air tool oil directly
to air inlet.
Tool is exces-
sively noisy/
emits high
pitched sound
Air Motor
is lacking
lubrication
Stop use immediately and add air tool oil directly
to air inlet.
Tool vibrates
excessively
during use
Loose Chuck
Jaws Tighten Chuck Jaws.
Out of balance
condition from
damaged Chuck
Stop use immediately, check for damaged Chuck.
Out of balance
condition from
damaged drill bit
or accessory
Stop use immediately, replace damaged drill bit
or accessory.
TROUBLESHOOTING

© Copyright 2017 Easthill Group, Inc. 8/17 Instruction item #31896Q Rev 1
If you have any questions about the use of this product, please contact
The Eastwood Technical Assistance Service Department: 800.343.9353 >> email: techelp@eastwood.com
PDF version of this manual is available online >> eastwood.com/31896manual
The Eastwood Company 263 Shoemaker Road, Pottstown, PA 19464, USA
US and Canada: 800.343.9353 Outside US: 610.718.8335
Fax: 610.323.6268 eastwood.com
ADDITIONAL ITEMS
#43656 Titanium Step Drill Bit Set
#15645 9 Piece, 2” Sanding & Prepping Kit
#70491 Eastwood Industrial Air Hose, 3/8” x 25’
#70492 Eastwood Industrial Air Hose, 3/8” x 50’
Table of contents
Other Rockwood Drill manuals