ROHS AM1-WA1 User manual

Cooling Fans Introduction FM
AC Input
MRS
AC Input
Variable Flow
MRS
AC Input
MU
DC Input
Long-Life
MDE
DC Input
MDS/MD
AC Input
MB
DC Input
MBD
AC Input
MF
DC Input
MFD Thermostats Accessories Installation
Cooling Module
Axial Flow Fans Centrifugal Blowers Cross Flow Fans
E-133
Cooling Fans
Thermostats
Thermostats

Cooling Fans
E-134 ORIENTAL MOTOR GENERAL CATALOG 2009/2010
Features E-134 /Product Line E-134
●Additional Information●
Technical Reference ➜ Page F-1
Safety Standards ➜ Page G-2
Thermostats AM1-WA1 and AM1-XA1
automatically performs ON/OFF fan control in
accordance with the temperature fluctuation inside
the equipment. It helps improve the equipment’s
“environmental” performance relative to energy
savings, noise reduction, etc.
List of safety standard approved products (Model, Standards, File No., Certification Body)
●
➜Page G-11
Features
■
Effective for Energy-Saving
●
Thermostat makes it possible for fans to operate only when cooling
is necessary.
This product makes for energy-saving by automatically stopping fans
for example, at night, when the amount of heat generation declines
following the load rate’s decline in equipment, or in winter, when the
ambient temperature drops and forced cooling is not necessary.
Noise Reduction
●
The fans are operated only when cooling is required, thereby keeping
fan noise to a minimum.
● RoHS-Compliant
Thermostats AM1-WA1 and AM1-XA1 conform to the RoHS
Directive that prohibits the use of six chemical substances including
lead and cadmium.
Details of RoHS Directive
● ➜Page G-38
Easy Setting
●
Range of operating temperature: 0 to +60˚C (+32 to +140˚F)
In addition, the setting is very easy; all you have to do is set the front
dial to the desired temperature.
Elimination of Power Supply
●
There is no need to provide a separate power supply for the
thermostat.
Conforms to DIN Rail, Compact Design
●
W33 mm×H60 mm×D35 mm (W1.30 in.×H2.36 in.×D1.38 in.)
Thermo bimetal built-in thermostat
Product Line
■
Type Model
Fahrenheit AM1-WA1
Centigrade AM1-XA1
Thermostat, Operating Manual
The following items are included in each product.
Specifications
■
Item Specifications
Type of Sensor Thermo bimetal, Contact: Normal open
Operating Temperature Range [0∼60˚C (+32∼140˚F)]±10˚C (18˚F)
Differential [Operating temperature −7˚C (12.6˚F)]±4˚C (7.2˚F)
Applicable Lead Wire Size AWG18∼14 (0.75∼2.5 mm2)
General Specifications
■
Item Specifications
Dielectric
Strength
Between the frame
and the terminal
Sufficient to withstand 3.75 kVAC for one minute under
normal ambient temperature and humidity.
Between the
terminals
Sufficient to withstand 0.5 kVAC for one minute under
normal ambient temperature and humidity.
Ambient Temperature −20∼+80˚C (−4∼+176˚F)
Ambient Humidity 90 % or less (non-condensing)
Color Light gray
Notes:
If foreign objects get into the sensor, the thermostat may not work properly. The use of a filter
●
at the intake is recommended so foreign objects will not enter the area where the sensor is
located.
Be sure to use the applicable products.
●
Install the product on an IEC (DIN) rail. Make sure that no force (tension, stress, etc.) is
●
applied to the terminal section.
Thermostats
AM1-WA1/AM1-XA1
RoHS-Compliant
AM1-WA1 AM1-XA1

Cooling Fans Introduction FM
AC Input
MRS
AC Input
Variable Flow
MRS
AC Input
MU
DC Input
Long-Life
MDE
DC Input
MDS/MD
AC Input
MB
DC Input
MBD
AC Input
MF
DC Input
MFD Thermostats Accessories Installation
Cooling Module
Axial Flow Fans Centrifugal Blowers Cross Flow Fans
E-135
Specifications E-134 /Dimensions E-135 /Connection E-135
ON/OFF Control of a Single Fan
●
When the temperature within the enclosure rises to a specified level
(preset temperature), the thermostat activates the fan automatically.
Once the enclosure interior is sufficiently cooled, it causes the fan to
stop. This is a great way to save energy and reduce noise.
Application Example
◇
AM1-XA1
AM1-WA1
Connection Example
◇
Cooling Module FM Series
AC Power Supply
AM1-WA1
AM1-XA1
ON/OFF Control of Multiple Fans
●
Multiple fans can be effectively controlled in cases where more than
one fan is needed to produce the required air flow or static pressure.
For example, a thermostat can control a maximum of nine MU1238
type fans. (A six-fan configuration is shown.)
Application Example
◇
MU1238
AM1-WA1
AM1-XA1
Connection Example
◇
AC Power Supply
AM1-WA1
AM1-XA1
When using 6 fans (
● MU1238)
Thermostat
Number of
Fans
Input
W
Noise Level
dB (A)
ON 6 84 51
OFF – 0 0
Applicable Products
■
Input Series Model Number of Connectable Fans
Single-Phase
AC-Input
MU Series All models 9
FM Series All models 9
MRS Series
MRS25 1
MRS20 2
MRS18 2
MRS16 5
MB Series
MB1665✽
MB1255 1
MB1040 4
MB840 7
MB630, MB520 9
MF Series MF930, MF915 5
For
✽ MB1665 type, thermostats can be used only for single-phase 100 VAC and 200 VAC
products.
Note:
Impression of voltage exceeding the rated voltage may shorten the service life of the product.
●
Dimensions
■ Unit = mm (in.)
Mass: 45 g (1.6 oz.)
AM1-WA1: E108
AM1-XA1: E108
12
60 (2.36)
33 (1.30)35 (1.38)
Effective Use of the Thermostat
■
Using a fan with a thermostat provides automatic on/off control of the fan and air flow switching.

Cooling Fans
E-136 ORIENTAL MOTOR GENERAL CATALOG 2009/2010
Features E-134 /Product Line E-134
Control the Number of Constant Speed Fans in Operation
●
The use of two thermostats enables switching the number of
fans being operated to change the air flow in accordance with
temperature.
This helps save energy and reduce noise.
This control method is effective with densely mounted equipment.
●
Application Example
◇
MU1238
AM1-WA1
AM1-XA1
Connection Example
◇
AC Power Supply
■Temperature of Lower
Set Temperature: 25°C (77°F)
■Temperature of Upper
Set Temperature: 40°C (104°F)
AM1-WA1
AM1-XA1
ON
OFF
ON
OFF
Time
Upper
No Operation
Inside
Temperature
Operation OperationMax. Load of System
40˚C (104˚F)
33˚C (91˚F)
25˚C (77˚F)
18˚C (64˚F)
Lower
No Operation
Notes:
Connect the lead wire to the thermostat as shown in the diagrams, regardless of how many fans are used or of the fan's wire diameter.
●
When connecting multiple fans, always use a terminal block. Don't connect the lead wires of multiple fans directly to the thermostat.
●
When using variable flow fan, don't connect the lead wires for connecting variable resistor directly to the thermostat.
●
Recommended Crimp Terminal
●
Crimp terminal is not included. When crimp terminal is required for connecting, use the crimp terminal shown below.
Phoenix Contact Inc: Al 1-8
Applicable lead wire size: AWG18
MU1238
● Type Multiple Switching Control
Temperature
Number of
Fans
Input
W
Noise Level
dB (A)
High 40˚C
(104˚F) 684 51
Low 25˚C
(77˚F) 342 48
This manual suits for next models
1
Table of contents
Popular Thermostat manuals by other brands

Honeywell
Honeywell FocusPRO 6000 Series Competitive comparison

Grasslin
Grasslin Termo 605 user manual

Gingerway
Gingerway GW-4361 instruction manual

Honeywell Home
Honeywell Home The Digital Round T8775A installation instructions

BASETech
BASETech 1539300 operating instructions

Aprilaire
Aprilaire 8400 series owner's manual