SAN-UP MJS 218 User manual

HUMIDIFICADOR ULTRASÓNICO
ULTRASONIC
HUMIDIFIER
Modelo/Model MJS 218
Manual
de instrucciones
Instructions manual
IMPORTANTE:
Para habilitar la garantia:
Registre su Producto
ingresando a:
www.sanup.com.ar
Registro de Producto y
complete el formulario.
Gracias

Índice
Atención.........................................................................2
Datos Técnicos y Estructura...............................................3
Instrucciones de uso.........................................................4
Limpieza y cambio de filtro de agua.................................4
Consejos.........................................................................5
Limpieza con detergente de ácido cítrico...........................5
Soluciones a problemas...................................................6
• No desmonte, ni repare, ni reconstruya el aparato por su
cuenta, diríjase a un service autorizado.
• Si el cable está estropeado, solo se realizará el cambio
en un service autorizado.
• Notome el enchufe con las manos mojadas.
• En caso de haber ruidos u olores extraños, apague
el aparato.
• Antes de limpiar o trasladar el aparato, apáguelo.
• Notoque el agua o el componente del sumidero
siel aparato estáen marcha.
• No arranque el aparato sin agua enel tanque.
• No raye el transductorcon objetos duros.
• No deje correr agua enel cuerpo principal del aparato.
• Notoque el transductor cuando el aparato está
en marcha.
• Si no utiliza el aparato por un largo período de tiempo,
desenchúfelo.
• No descargue el tanque sinapagar el aparato primero,
esto dañaría el transductor.
• Nollene el tanque con agua a más de 40º, cambiaría
el color ola apariencia del aparato.
• Para asegurar que el humidificador funcione bien,
coloque, el aparato enlos siguientes sitios:
Atención
2

Capacidad: 2 L
Autonomía: ≤8 hs.
<35dB
≥260 ml


5
Español
Consejos
• Utilice agua del grifo o agua desmineralizada.
• Limpie el transductor, el tanque y el cuerpo principal cada
semana.
• Cambie el agua frecuentemente para mantener el tanque
limpio.
• Mantenga el tanque y el sumidero seco si no se usa el humi-
dificador por largo plazo.
• Deje todos los componentes del humidificador secos antes
del embalaje.
• No toque el transductor con objetos duros, límpielo con un
paño húmedo. Es mejor que lo limpie con agua salada.
Limpieza con detergente de ácido cítrico
1) Apague y desenchufe el humidificador.
2) Seque el agua del sumidero.
3) Vierta 1 o 2 gotas de ácido cítrico sobre el transductor. Tire
el agua caliente (60º) en el sumidero hasta que el agua corra
sobre la placa de encender.
4) Limpie con un paño la superficie del transductor.
5) Después, limpie el sumidero otra vez con agua limpia.

Soluciones a problemas
6
Español
Indicador LED enmodo
en espera no ilumina,
no sale viento, ni niebla
No está bien conectado
ala corriente eléctrica Conecte el enchufe en
el tomacorriente
Luz roja de indicador
iluminada, no sale
viento ni niebla
No hay agua en
el tanqueRellene el agua en
el tanque
Nieblasale con olor
El aparato es nuevoAbra el tanque y
póngalo boca arriba
por 12 horas
No sale niebla
El transductor está
sucioLimpie el transductor
El agua estásucia o
guardada por largo
tiempo en el tanque
Limpie el tanque
y cambie el agua
Ruidos extraños
No se ubica bien
el aparatoPonga el aparato en
un sitio plano y sólido
No corre agua
La tapa del tanque
está sucia o el tanque
no está bienlocalizado
Limpie la tapa y localice
bien el tanque
Demasiada agua en el
sumidero
Tire el agua y refije
la tapa del tanque
El agua estásucia
Limpie el tanque y
rellene con agua limpia
ProblemasCausaSolución

•Do never arbitrarily disassemble, repair or restructure the
apparatus. It must be serviced by the manufacturer, its service
agent or similarly qualifiedpersons in orderto avoid a hazard.
•Any change tothe humidifier may cause hazard without our
company’s permission.
•If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in ordertoavoid a hazard.
•Do not arbitrarily replace the power cord.
•Never handle plug with wet hands.
•Turn off and unplug if there is any abnormal noise or smell.
It must be maintained by service agent if needed.
•Turn off and unplug before cleaning or move.
•Do not touch the water or the parts in the gutter during work.
•Do not turn on the humidifier without water in the gutter.
•Do not scratch transducer with hard objects.
•Do not let the water flow or splash into the main body when
doing cleaning otherwise the units may be damaged.
•Disconnect the power before move if the humidifier is not level.
•Do not touch the transducer when the humidifier is working,
otherwise you may be hurt.
Important safeguards
Contents
7
English
Important Safeguards......................................................7
Technical Data.................................................................8
How to use.....................................................................9
Cleaning and replacement of water filter............................9
Suggestion....................................................................10
Usage of citric acid cleaning mixture
or other cleaning medicament........................................11
Troubleshooting............................................................11

•Do not pour the water into the gutter directly.
•Remember to disconnect the power if the humidifier is going
to be left unused for a long time.
•Never drain water from the gutter before disconnecting the
power, otherwise transducer will be destroyed.
•Do not pour the water over 40º C into the tank, otherwise the
color or shape may be changed.
•To make sure the humidifier work well and avoid accidents,
please choose carefully the places where you put the humidifier:
a. Where plain and firm.
b. Where far from heat resources or sunlight.
c. Where far from furniture and home appliances, otherwise
the furniture and home appliances may be affected with damp.
d. Where with a normal temperature (5ºC-40ºC), otherwise the
humidifier may be destroyed in the cold environment.
Model: MJS-218
Rated voltage 220V – 240V 50Hz
Tankage Rated power: 30w
Mist: 260mL/H
Noise: <35dB
Technical data
1)Air flow outlet
2) Handle
3)Tank
4)Cover
5)Transducer
6)Main body
7)Empty indicator
8) On/Off & Mist
control knob
9) Power indicator
8
English
1
2
3
4
5
6
7
8
9
R
E
P
U
B
L
I
C
A
A
R
G
E
N
T
I
N
A
Capacity: 2 L
Autonomy: ≤8 hs.



Usage of citric acid cleaning mixture or other
cleaning medicament
Troubleshooting
11
English
1.Turn off and unplugthe humidifier.
2.Drain water from the gutter.
3.Put 5 to 10 drop medicament or 1 to2 gram citric acid grainy
on the transducer., then pour warm water(about 60ºC) into the
gutter until the water flows overthe heating panel.
4.Brush the surface of transducer and heating panel carefully
2 to5 minutes later. Repeat the above steps if the scale can’t be
totally cleanedone time.
5.After cleaning upthe furring, please wash the sink with fresh
water before you use it.
Standby indicator
not works; no wind;
no mist
Power not connectedConnected the power
plug
Water-short indicator
on, no wind, no mistShort of waterFill with water in
the tank
Mist with abnormal
smell
New applianceOpens the tank and
puts the mouth of the
tank in shade
for 12 hours
Mist generation
abnormal
The transducer
begrimed Clean the transducer
Dirty water or the
water left toolong
Clean the tank and
replace with clean water
Abnormal noise
Resonate between the
appliance and the layerPut the appliance on
a firm layer
Water not used
The dirty cover of the
tank or the tank not
put properly
Clean the cover and put
the tank on right place
Too much water in
the gutter
Reduce some water and
re-fix the cover of tank
Dirty water
Clean the tank and
replace with clean water
Problem CauseSolution

- Las reparaciones se realizarán únicamente en los domicilios de los Services Autorizados
por San Up S.A.
-
Durante la vigencia de la Garantía los gastos de traslado se regirán por la Ley 24.240.
- El plazo máximo de cualquier reparación no superará los 90 días a partir del pedido de
cumplimiento efectuado por el usuario.
ESTA GARANTÍA DEBERÁ ESTAR ACOMPAÑADA DE LA FACTURA
DE COMPRA, DE LO CONTRARIO NO TENDRÁ VALIDEZ.
IMPORTA Y GARANTIZA: SAN UP S. A.
Ruta 8 N.º 2967- San Martín- Pcia. Buenos Aires- Argentina
GARANTÍA
Garantizamos este artefacto por el término de 1 año contra todo defecto de
fabricación o en los materiales empleados.
Fecha:......................../.........................../..............................................................
Casa Vendedora:..................................................................................................
Sello y Firma:.......................................................................................................
El fabricante no se responsabiliza por eventuales daños producidos por el uso
incorrecto del artefacto, ni tampoco por roturas, maltrato o reparaciones
realizadas por personas ajenas a nuestra Empresa.
HUMIDIFICADOR ULTRASÓNICO
ULTRASONIC
HUMIDIFIER
Modelo/Model MJS 218
HUMI/43011 R03/1113
Table of contents
Languages:
Other SAN-UP Humidifier manuals
Popular Humidifier manuals by other brands

Aprilaire
Aprilaire 800 Series Installation & maintenance instructions

Orbegozo
Orbegozo HU 2013 instruction manual

Clean Air Optima
Clean Air Optima CA-606B manual

dyras
dyras UHM-355B instruction manual

HoMedics
HoMedics TOTAL COMFORT UHE-WM350 Instruction manual and warranty information

Guardian
Guardian H3250 Use & care instructions