Sanuvox SANUVAIR S1000 VOC User manual

Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.1
Instruction Manual
Photos illustrating products are non contractual.
SANUVAIR®S1000 VOC
SMOKE AND ODOR REDUCTION UNIT
Commercial Model
Installation Date: _______________ Installed by: _________________
Installer Contact Info.: _________________________________________
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit
or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.
1. Installation and servicing of UV units or systems (in an
air conditioning system or not) can be hazardous. Only
trained and qualied service personnel should install,
repair or service equipment.
2. Untrained personnel can perform basic maintenance
functions such as replacing lamp(s) and/or lter(s). All
other operations should be performed by trained service
personnel.
3. The unit is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
CAUTION: Unit is not a toy. Keep away from
unsupervised children. Do not leave children unattended
with the unit.
4. DO NOT hang onto the UV unit or system.
5. Some UV units or systems could be heavy: Make sure
you have a minimum of 2 people to safely move or install
these UV units or systems, and make sure you adopt the
most ergonomic position possible (use UV unit or system
handles, if applicable).
CAUTION: Installing or maintaining heavy equipment,
especially overhead, can cause back pain or other injuries.
6. When installing or servicing an overhead UV unit or system,
be careful not to fall off the stepladder. Furthermore, make
sure the UV unit or system latches are always in place to
prevent falling parts.
CAUTION: Some parts of some UV units and systems
may open suddenly if the UV unit or system is installed
high up without its locks.
7. Units that are obviously damaged must not be operated.
8. CAUTION: When working on the UV unit or system,
observe precautions on the literature, tags and labels
attached to the UV unit or system, and all other safety
precautions considered as best practices in the HVAC
industry, if applicable.
9. When applicable, local regulation may comprise more
restrictive installation and/or certication requirements.
The aforementioned requirements prevail on those of this
document and the installer agree to conform to these at his
own expense.
10. Follow all the safety instructions outlined in this document
and respect all local and national codes applicable.
11. All UV units or systems contain a UV-C source. Damage to
the housing or unintended use of the UV unit or system may
result in harmful UV-C leaks. UV-C may, even in little doses,
cause harm to the eyes and skin.
12. Never expose eyes or skin to an operating UV lamp.
Therefore, before installing or performing maintenance
on the UV unit or system, TURN OFF AND DISCONNECT
the UV unit or system from all power sources (there
may be more than one switch to disconnect) and also
disconnect the HVAC system, is applicable.
CAUTION: Electrical shock may cause injuries or
possibly death. FIRST AID INSTRUCTIONS: If injured,
consult a doctor.
13. UV rays may damage certain types of lters (polymer or
plastic); please keep the UV unit or system light away from
shining directly on plastic.
14. When installing or performing maintenance on the UV unit
or system, it is recommended to wear safety gloves. In
order to avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
15. Just like conventional uorescent lamps, UV lamps contain
a small quantity of mercury: if a lamp breaks, clean and
dispose of with care. UV lamps can be disposed/recycled
after use in the same way as any other uorescent lamps.
Contact and follow the specic instructions of your local
and national authorities.
15.1. Dispose of unit or system according to the specic
instructions and standards of your local and national
authorities.
16. Use only specied SANUVOX branded replacement
UV lamps for your UV unit or system. Use of any other
lamps will void your warranty and can result in damage to
the UV unit or system.
17. Sanuvox UV units or systems are not waterproof. DO NOT
INSTALL OUTDOORS OR IN WET LOCATION unless
specied otherwise.
18. Use of this unit or system supplements, but does not
replace, infection control best practices. Users must follow
all these practices, particularly with regard to cleaning and
disinfecting surfaces.
SAVE THESE INSTRUCTIONS
For any inquiries on a UV unit or system, contact:
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
REGISTER
YOUR WARRANTY

2
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS 1
TABLE OF CONTENTS 2
ABOUT THE PRODUCT 3
COMPONENTS 3
How it Works 3
SETUP & INSTALLATION 4
What you will need 4
What’s included 4
Step by Step Installation | UV Lamp(s) & Filters 4
Step by Step Installation | Added Ducts 6
Step by Sep Installation | VOC Detector 7
OPERATION 8
How to Operate your Product 8
How to Select Speed 8
MAINTENANCE 8
How to Replace Lamp 8
Step by Step Lamp Replacement 8
How to Replace Filters 9
Step by Step Filter Replacement 9
How to Replace VOC Detector 10
Step by Step VOC Detector Replacement 10
How to Clean your Product 10
STORAGE 10
ULTRAVIOLETS 10
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE 10
TROUBLESHOOTING 11
Problems & Solutions Table 11
Step by Step Test Procedure A 11
WARRANTY 12
CUSTOMER SERVICE 12

B
D
C
E
G
F
H
I
A
J
3
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
ABOUT THE PRODUCT
The Sanuvair® S1000 VOC is designed to help reduce smoke buildup by continuously drawing air through a UV chamber. The
detector automatically turns on and off a second lamp to actively deal with the increase or decrease of smoke.
For information or recommendations on how to size your specic application, please call SANUVOX at 1-888-726-8869.
COMPONENTS
How it Works
The Sanuvair® S1000 VOC is comprised of a ventilator, speed selection switch, a MERV8 prelter, two UV lamps and a volatile
organic compound (VOC) detector. The ventilator pulls air through the unit, exposing it to the UV lamps, which reduces odors
through a photo-oxydation process. Air is then circulated through the MERV8 prelter and supplied back to the room. The VOC
detector turns the second UV lamp on when required.
A. Holes for 1 x pair of 8" inlet collars
B. Holes for 1 x pair of 8" outlet collars
C. 2 x 16" UV ‘J’ lamps
(one with blue tips, and the other with yellow tips)
D. Aluminum reecting chamber
E. 2 ballasts
F. Door
G. 1 x 2" MERV 8 prelter
H. Safety cut-off switch
I. Power 120 Volt or 230 Volt
J. VOC detector

4
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
SETUP & INSTALLATION
What you will need
Utility knife, scissors, suitable wall plugs and screws (as needed), screwdriver and pliers.
CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack,
install and setup your product. Conrm you have access to the necessary power source for the product requirements (see unit
or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.
What’s included
The Sanuvair® S1000 VOC, a 2" MERV 8 pleated pre-lter, additional pre-lters for replacement (2), a UV lamp with blue tips, a
UV lamp with yellow tips, a VOC detector with its connection caps, 20' of wiring and a basic installation kit.
Step by Step Installation | UV Lamp(s) & Filters
STEP 1
STEP 2
Remove
access door
to the UV
Lamp(s)
1. Open the unit access door of your S1000 VOC unit.
2. The UV lamps will be installed in the Aluminum Reecting Chamber.
Start with the blue-tipped lamp, which should be installed at the
back of the unit. To slide out the Aluminum Chamber, remove the two
buttery bolts and screws which secure it in place.
The installation kit includes: a UV caution decal, a maintenance decal, a pair of cotton gloves, a pair of 8" inlet collars, a pair of
8" outlet collars, Phillips screws (12) and larger screws for installation (4).

5
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
STEPS 3 & 4
3. Adhere the included foam gasket (included in the Lamp box) to the
porcelain end-cap with the 4 pins.
4. Insert the end-cap with foam gasket into the clamp* assembly and
tighten. Be careful not to over tighten as it may result in end-cap
breaking.
NOTE: A clamp (or up to four, if you ordered addditional lamps) is there
to hold the lamp(s).
STEP 6
STEP 5
STEP 7
5. Insert the white-plug into the UV Lamp’s 4 pins. The plug will only t
in two of four ways. Either way is ne. The exposed wire-set is Teon
coated and is resistant to UV exposure.
Repeat steps 2 through 5 for the second lamp (yellow tips) which must
be installed near the access door.
6. UV Lamp(s) and Ballast Position: The lamp should be positioned
towards a central point in the middle of the unit’s aluminum reection
chamber. For models with multiple lamps, you must position the lamps in a
‘X’ to bring them closer to the middle and optimize the UV dose of the unit.
7. Insert the MERV 8 prelter. Follow the arrow for airow for proper lter
direction.
8. After the lter is installed, close the latch to secure the lter in place.
Close the door of the blower compartment.
You are now ready to install your S1000 VOC unit.

6
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
STEP 1
STEP 2
STEP 3
Step by Sep Installation | Added Ducts
Inlet Collar (left side) Outlet Collar (right side) 1. Install Inlet / Outlet Collars (each collar is a set of 2" x 8" round
inlet and outlet): Open the access door and insert the two pairs of
collars into the S1000 VOC unit. Align the holes and screw down each
pair of collars from the top of the unit with the included philips screws (6
screws per collar).
NOTE: Pay special attention to the orientation of the notch on the right
side collar.The notch (highlighted in black) should be pressed up against
the right side of the SANUVAIR®S1000.
3. Install your 8" pipes (rigid in aluminum or galvanized or aluminized
exible).
NOTE: When ducting-in the unit, avoid 90 degree elbows when possible.
Your are now ready to install
your VOC detector.
2. Secure the unit to the wall OR ceiling, using suitable supports, wall
plugs and screws (not included). Make sure you have a power outlet
nearby to plug the unit into.
CAUTION: Your S1000 VOC unit is bulky. Make sure that there are
always two people to lift and handle it to avoid any injuries.

7
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
1. Take the VOC detector out of its packaging and determine the best
location to install it.
NOTE: The VOC detector should be installed near the main source of
volatile organic compounds (smoke, dirty air, etc.), on a wall, 6" from the
ceiling.
2. Install the detector on the wall using the appropriate screws.
STEP 3
STEP 4
Step by Step Installation | VOC Detector
STEP 1 & 2
3. Remove the cover of your detector to make the connection: Use the
supplied cable to connect your detector to your unit. If the 20' of wire are
not enough, you can use BX wiring with 3 wires.
4. Use the connection caps (included) to connect the wires from the
connector box to the same colored wires from your unit.
5. Adjust your detector settings as needed, then replace your detector cover.
NOTE : The detector is pre-set to 3.0V DC by default. To adjust these
settings use a voltmeter with “alligator” type probes, as well as a small
screwdriver to turn the adjustment screw. The closer your setting is to 3.0V
DC, the more sensitive the detector will be and the faster it will trigger.
6. Turn the unit ON and wait approximately 5 minutes for the startup phase
to be completed, and for the VOC detector to calibrate. Use a gas lighter
(no ame), near the detector, which should trigger it. The second lamp
should turn on (with the appropriate LED on the front plate).
Positive
Neutral
Sensor
Setting Screw:
triggers at
3.0V DC
Your new SANUVAIR®S1000 VOC is now ready to operate!

8
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
OPERATION
How to Operate your Product
The Sanuvair® S1000 VOC is an automatic unit: once it’s installed and plugged in, simply press the power switch to turn it ON.
How to Select Speed
The Sanuvair® S1000 VOC features a variable speed control, located on the front of the
unit.
It is recommended that the unit be operated at its highest speed at all time to maximize
the benets of the air purier.
MAINTENANCE
How to Replace Lamp
Replace UV lamps yearly. Replacing lamp on the Sanuvair® S1000 VOC is quick and easy. Simply turn off the power source,
unlatch and open the access door, unscrew the metal access plate to the reection chamber, remove and dispose of old lamps,
replace with new Sanuvox branded UV lamps, screw back the metal plate, close the access door and turn power source back
on. See below for detailed step by step instructions.
CAUTION: In order to avoid reduced performance of lamps, do not touch lamp glass without gloves.
Step by Step Lamp Replacement
STEP 1 1. Unlatch and open the access door and unscrew the metal access plate
to the reection chamber.
CAUTION: Before installing or performing maintenance on the unit or
system, TURN OFF AND DISCONNECT the unit or system from all
power sources.
2. Prepare the new lamp. Remove the contents from packaging. Only
after you have visually inspected the UV lamp should you break the
security seal on the underside of the cardboard sleeve. Be sure to wear
the cotton gloves (included) guaranteeing a clean lamp free from
ngerprints.
NOTE: Fingerprints on the lamp might negatively impact the UV output
of the lamp.
3. While holding the new UV lamp by its porcelain end-cap, slide it into the
metallic reection chamber.
STEP 2
STEP 3
STEP 4
4. Slide the porcelain tip through the retention clamp.
NOTE: Make sure the lamp is horizontal in this section and not touching
the metal walls.

9
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
5. Carefully push the white connector onto the four pins. The plug is
designed so it can only be installed one way. You may have to rotate the
socket 90° to line up the pins with the holes. The connector will t into
position.
NOTE: Too much force applied from the opposite end-cap may break
the lamp.
Repeat steps 2 through 5 for the second lamp. Respect the placement
of the lamps: the lamp with blue tips at the back, and the lamp with
yellow tips near the access door.
6. Screw back in place the metal plate and close the access door.
STEP 5
STEP 6
How to Replace Filters
Replace prelter every 3 to 6 months or as needed.
Check regurlarly to maintain maximum performance of your unit.
Step by Step Filter Replacement
1. Open the lters and motor access door at the front of the unit.
Start by unlocking the access door latches.
2. After opening the unit’s access door, grasps both edges of the prelter
and pull with equal force to slide it out.
3. Unpack the new prelter and place it in the unit, then close the access
door.
NOTE: Make sure to install lters according to air ow direction for
maximum performance.
STEP 1
STEP 2
STEP 3

10
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
ULTRAVIOLETS
Ultraviolet wavelengths (UV) emitted by Sanuvox units and systems are identical to ultraviolets produced by the sun. UVC
damage nucleic acids (DNA/RNA) of microorganisms, which inactivates them. Unlike conventional UV lamps on the market,
Sanuvox units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces.
CAUTION: Never expose eyes or skin to an operating UV lamp.
STORAGE
The Sanuvair® S1000 VOC unit is xed installation and therefore, requires no specic storage.
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE
The Sanuvair® S1000 VOC has a power consumption of up to 750W.
The product is rated at 120/240 VAC, 50/60 Hz.
See product label to conrm power consumption of your specic unit or system.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY.
DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE
PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO
MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.
How to Clean your Product
Maintenance of the unit should be perform at the regular intervals to keep the benets of the UV air purier.
For optimal performance, the lamp should be kept free of dust and residue deposit. Clean when necessary with mild soap or
alcohol. Always spot test the cleaner to make sure it does not damage the surface.
Once a year or as needed, clean the interior of the unit (wall and motor plate), with mild non-abrasive soap. It is recommended
to use products that are environmentally friendly.
CAUTION: Under no circumstance should water be sprayed or splashed onto the product.
How to Replace VOC Detector
Replace VOC Detector every 5 years.
Step by Step VOC Detector Replacement
1. Turn OFF your unit.
2. Prepare the new VOC detector.
3. Unplug and dispose of the old VOC detector.
4. Connect the new VOC detector.
5. Turn back ON the unit.
6. Wait approximately 1 to 2 minutes for the calibration period. To test
installation, use a gas lighter near the detector, which should turn on the
second lamp and ballast (and their associated LED on the front panel).
STEP 2

11
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
Problem Possible Cause Solution
Unit doesn’t come ON. - There is no power to the electrical outlet. - Make sure the power outlet is working.
- Make sure the unit is plugged in to 120V
outlet.
- The On/Off switch is not ON. - Push the ON button on the display.
- The power cord is damaged. - Replace power cord.
- The micro switch / cut-off switch is not well
engaged.
- Make sure the lamp door is well closed.
- Make sure the lamp door pin pushes on the
micro switch / cut-off switch.
Unit comes ON, but 1 or more lamps are
OFF: their “glow” isn’t visible throught the
outlet louver.
- Defective lamp(s)
- Defective ballast(s)
- Defective VOC detector
- Follow Test Procedure A at the
bottom of the page.
Unit comes ON and lamps are ON, but the
motor is not turning or is making rattling
noise.
- Motor is defective. - Replace motor.
- Motor wire connection is not properly
connected.
- Check motor wire connections, making sure
there are no loose wires..
Unit operates only on one speed. - Defective speed control or loose wiring. - Check wiring or replace speed control.
Contact your contractor for all your needs in terms of replacement parts:
power cord, control panel display, UV lamp, ballast, lter, grill, fan motor, stand, handle, etc.
TROUBLESHOOTING
If your product is not working properly, refer to the following.
What you will need
A Phillips No. 2 screwdriver and spare parts.
Step by Step Test Procedure A
1. Turn the unit OFF and ON. Wait for the VOC detector to calibrate (5 min).
2. Use a gas lighter near the VOC detector (no ame).
Lamp and ballast LED #2 should turn ON.
3. If ballast LED #2 is still OFF, replace ballast.
If lamp LED # 2 is still OFF, test lamp by swapping with Lamp #1. If Lamp was defective, replace lamp.
If both LED (lamp and ballast #2) are still OFF after replacing, adjust sensitivity of the VOC detector: Attach alligator clips to
the positive and neutral post on the electronic card. Use a screwdrive and adjust the screw, which will increase or diminish
the voltage (factory set at 3.0 VDC). The higher the voltage, the quicker the detector reacts.
4. If both LED (lamp and ballast #2) are still OFF after replacing the lamps and ballasts, and adjusting the VOC detector,
change the VOC detector.

12
Instruction Manual for Sanuvair®S1000 VOC
1-888-726-8869www.sanuvox.com
WARRANTY
You should rst read all instructions before attempting to use this product.
For this warranty to be valid, keep a copy of the proof of purchase.
UV lamps 1 year
Ballast 3 years
Electric Motor 1 year
VOC Detector 1 year
A. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to
damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered
manufacturing defects under this warranty.
SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so
the above limitations or exclusions may not apply to you. This warranty gives specic legal rights, and you also may have other rights which vary from
jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. This warranty does not cover the lters, prelters or other accessories (if included), except for material or workmanship defects.
Call us toll-free at 1-888-726-8869 or email: [email protected]
Please be sure to specify product name.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT
TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING
CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.
CUSTOMER SERVICE
TO ORDER REPLACEMENT PARTS
PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE
Toll-Free Phone #: 1-888-726-8869
Email: [email protected]
Website: www.sanuvox.com
Please be sure to specify product name.
Replacement parts for this product
BST120/277SHS Ballast with multi-voltage input of 120-277 VAC, 50/60 Hz
LMPHXJ160 T6 High Intensity 16" ‘J’ shaped UV lamp (blue caps)
LMPHGXJ160-4 T6 Dual Zone High Intensity 16" ‘J’ shaped UV lamp (yellow caps)
FTR-17 MERV 8 Prelter
or the MERV 8 carbon prelter #FTR-2A
ELC-DET-VOC-1A VOC Detector
FLEX0825 8" diameter exible tubing, 25' long
WARNING: Use only specied SANUVOX branded replacement UV lamps with your unit or system. Use of any other
lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).
REGISTER
YOUR WARRANTY
ONLINE AT
www.sanuvox.com
Table of contents
Other Sanuvox Fan manuals
Popular Fan manuals by other brands

Salda
Salda VSA 220 M 3.0 Installation instruction

OSTBERG
OSTBERG LPKB Series Directions for use

Vectaire
Vectaire ELEGANCE EL1203 Installation and operating instructions

KDK
KDK K12UX Operating and installation instructions

Helios
Helios M1/120 N/C Installation and operating instructions

Barcol-Air
Barcol-Air CERA-1 installation instructions