1. About this document
1.1 Function
These operating instructions provide all the information required for
mounting, commissioning, safe operation and also disassembly of
the device. The operating instructions must be available in a legible
condition and a complete version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The passive fieldbox must only be used according to the following
versions or for applications that are approved by the manufacturer.
Detailed information regarding the range of applications can be found in
the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
Content
1 About this document
1.1 Function ..............................................1
1.2 Target group: authorised qualied personnel..................1
1.3 Explanation of the symbols used ...........................1
1.4 Appropriate use ........................................1
1.5 General safety instructions ...............................1
1.6 Warning about misuse ...................................2
1.7 Exclusion of liability .....................................2
2 Product description
2.1 Ordering code .........................................2
2.2 Destination and use .....................................2
2.3 Technical data .........................................2
3 Mounting
3.1 General mounting instructions .............................3
3.2 Dimensions ...........................................3
3.3 Accessories ...........................................3
4 Electrical connection
4.1 General information for electrical connection..................3
4.2 LED indicators and fuse elements ..........................3
4.3 Pin assignment of module connection .......................4
4.4 DIP switch conguration and jumper ........................5
4.5 Connector conguration..................................5
4.6 Wiring example ........................................6
5 Set-up and maintenance
5.1 Functional testing.......................................8
5.2 Maintenance ..........................................8
6 Disassembly and disposal
6.1 Disassembly...........................................8
6.2 Disposal ..............................................8
7 Conguration
7.1 Conguration examples ..................................8
103013760-EN / D / 2019-01-07
EN Operating instructions. . . . . . . . . . . . .pages 1 to 8
Original

2
Operating instructions
Passive fieldbox PFB-SD-4M12-SD
EN
1.6 Warning about misuse
In the event of improper or unintended use or tampering, use
of the passive fieldbox could expose persons to danger or
cause damage to the machine or system components.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
PFB-SD-4M12-SD
Option Description
PFB Passive fieldbox
SD Evaluation side: SD interface
4M12 4 device connectors for M12 connector
SD Device connection: SD interface
2.2 Destination and use
The passive fieldbox PFB-SD-4M12-SD is designed for the connection
of 4 electronic safety relays in SD interface version of the manufacturer
SCHMERSAL. It serves to connect up to 4 safety switchgear units in
series.
In order to increase the safety function, it is possible to connect multiple
passive fieldboxes in series.
The secure OSSD outputs of the connected safety relays are switched
in series and wired to a compatible security analysis by the passive
fieldbox PFB-SD-4M 12-SD.
The non-secure SD interface signals of the devices are connected in
series and wired to an SD Gateway.
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
2.3 Technical data
Standards: IEC 60947-1
Materials:
- Enclosure: polyamide / PA 6 GF
- Inspection window: polyamide / PACM 12
- Encapsulation: polyurethane / 2K PU
- Labelling plates: polycarbonate / PC
Mechanical data
Type of electrical connection: Panel jack / integrated socket
Connection:
- Connectors: M12 / 8-pole, A-coded
- Power: M12-Power / 4-pole, T-coded
- IN & OUT signals: M12 / 4-pole, A-coded
Tightening torque of connectors:
- M12 connector: max. 1.5 Nm
- Recommended for SCHMERSAL cables: 1.0 Nm
Fixing screws: 2x M6
Tightening torque of the fixing screws: max. 3.0 Nm
Ambient conditions
Ambient temperature: −20 °C … +65 °C
Storage and transport temperature: −25 °C … +70 °C
Relative humidity: 10 % … 95 %, non condensing
Resistance to shock: 30 g / 11 ms
Resistance to vibration: 5 … 10 Hz, amplitude 3.5 mm;
10 … 150 Hz, amplitude 0.35 mm / 5 g
Protection class: IP67 to IEC 60529
Protection class: III
Insulation values to IEC 60664-1:
- Rated insulation voltage Ui: 32 VDC
- Rated impulse withstand voltage Uimp:0.8 kV
- Over-voltage category: III
- Degree of pollution: 3
Electrical data
Supply voltage UB: 24 VDC -15% / +10%
(stabilised PELV mains unit)
Rated operating voltage Ue: 24 VDC
Operating current Ie:
- Fieldbox (external fuse protection required): 10 A
- Derating M12 Power connector: 10 A to 55 °C
7 A to 65 °C
- Device connection: 0.8 A
(internal protection available)
- Safety outputs Y1 and Y2: 0.1 A
Device connection line fuse: Automatically resetting
fuse element 1.5 A
LED indications
1 green LED „Pwr“: Supply voltage fieldbox
4 green LED "P": Fuse-element device connection 1 - 4
4 yellow LED "I“: Input safety enable device connection 1 - 4
Protection class IP67 is only reached if all M12 connectors
and blanking plugs, as well as the inspection window are
properly fastening with screws.
All fieldboxes have a good resistance against chemicals
and oil. When used in aggressive media (.e.g chemicals,
oils, lubricants and coolants in high concentrations) the
material resistance must in each case be checked in
advance for the specific application.

3
PFB-SD-4M12-SD
Operating instructions
Passive fieldbox
EN
3. Mounting
3.1 General mounting instructions
Fasten fieldbox with two M6-screws on a flat mounting surface, for
mechanically strain-free installation. The maximum tightening torque is
3.0 Nm. Any mounting position.
Do not install fieldbox outside closed room
3.2 Dimensions
All measurements in mm.
36.1
25.6
135.6
156.6
63
3.3 Accessories
3.3.1 Cables
Power - Cable M12, 4 poles, straight, T-coded
5.0 m Pre-wired cable, female connector 103013430
10.0 m Pre-wired cable, female connector 103013431
3.0 m Connecting cable, male / female connectors 103013432
5.0 m Connecting cable, male / female connectors 103013433
7.5 m Connecting cable, male / female connectors 103013434
IN & OUT signals - Cable M12, 4 poles, straight, A-coded
5.0 m Pre-wired cable, male connector 103013421
10.0 m Pre-wired cable, male connector 103013422
3.0 m Connecting cable, male / male connectors 103013423
5.0 m Connecting cable, male / male connectors 103013424
7.5 m Connecting cable, male / male connectors 103013425
Device connection - Cable M12, 8 poles, straight, A-coded
0.5 m Connecting cable, male / female connectors 101217786
1.0 m Connecting cable, male / female connectors 101217787
1.5 m Connecting cable, male / female connectors 101217788
2.5 m Connecting cable, male / female connectors 101217789
3.5 m Connecting cable, male / female connectors 103013428
5.0 m Connecting cable, male / female connectors 101217790
7.5 m Connecting cable, male / female connectors 103013429
3.3.2 Colour codes of the Schmersal cables
M12, 4-pole M12, 8-pole
PIN Conductor colour PIN Conductor colour
1 BN Brown 1 WH White
2 WH White 2 BN Brown
3 BU Blue 3 GN Green
4 BK Black 4 YE Yellow
−−−5 GY Grey
−−−6 PK Pink
−−−7 BU Blue
−−−8 RD Red
3.3.3 Further accessories
Sealing stickers for inspection window, 4 pcs 103013919
Protective caps for M12 sockets, 10 pcs 103013920
Labels, frame 4 x 5 pcs 103013921
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
To supply the fieldbox, cables with a cross-section of maximum 1.5 mm²
can be connected.
Secure the supply voltage of the fieldbox with a 10 A fuse.
4.2 LED indicators and fuse elements
The fileldbox features 4 yellow and 5 green LED indicators.
1 green LED "Pwr" Supply voltage status of
the fieldbox
4 green LED "P"
at device connection
Fuse-element status
device connection
4 yellow LED "I"
at device connection
Safety enable status
connnected device
The 4 device connections are each equipped with an automatically
resetting 1.5 A fuse for wiring protection.
If the fuse element triggers, the respective green power LED "P" goes
out.

4
Operating instructions
Passive fieldbox PFB-SD-4M12-SD
EN
4.3 Pin assignment of module connection
Pwr
I OPower
2
1
3
4
P
I
P
I
P
I
P
I
I O
O
N
1 8765432
“POWER” LED
Device connection 2
Input LED
“POWER” LED
Device connection 3
Input LED
“POWER” LED
Device connection 1
Input LED
“POWER” LED
Device connection 4
Input LED
Connection Power-IN Connection Power-OUT
Power-LED fieldbox
DIP switch fieldbox configuration
Connection Out signals
SD and safety signals
Park position Jumper 2Park position Jumper 1
Jumper fieldbox configuration
Connection IN signals:
SD and safety signals

5
PFB-SD-4M12-SD
Operating instructions
Passive fieldbox
EN
4.4 DIP switch configuration and jumper
When you open the inspection window, ensure that no
moisture or excessive humidity penetrates into the fieldbox.
The position of the DIP switch and the jumper is shown in black.
Fieldbox in the centre of a series circuit.
4 devices connected
O
N
1 8765432
No jumper set
All switches OFF
3 devices connected
O
N
1 8765432
Jumper 5/6 set
Switch 5+6 ON
2 devices connected
O
N
1 8765432
Jumper 3/4 set
Switch 3+4 ON
1 device connected
O
N
1 8765432
Jumper 1/2 set
Switch 1+2 ON
Last fieldbox in the series circuit
4 devices connected
O
N
1 8765432
Jumper 7/8 set
Switch 7+8 ON
3 devices connected
O
N
1 8765432
Jumper 5/6 and 7/8 set
Switch 5+6 and 7+8 ON
2 devices connected
O
N
1 8765432
Jumper 3/4 und 7/8 set
Switch 3+4 and 7+8 ON
1 device connected
O
N
1 8765432
Jumper 1/2 and 7/8 set
Switch 1+2 and 7+8 ON
The sealing labels available as an accessory can be used
to seal the inspection window after the configuration has
been checked.
4.5 Connector configuration
4.5.1 Connector configuration of device connection
PIN Colour* Signal Description of device signals
1 WH A1 +24 VDC device supplied
2 BN X1 Safety input 1
3 GN A2 0 VDC device supply
4 YE Y1 Safety output 1
5 GY OUT Diagnostic output
6 PK X2 Safety input 2
7 BU Y2 Safety output 2
8 RD IN Solenoid control
4.5.2 Connnector pin assignment Power IN & OUT of fieldbox
PIN Colour* Signal Description
1 BN A1 +24 VDC device supplied
2 WH A2 0 VDC device supply
3 BU A2 0 VDC device supply
4 BK A1 +24 VDC device supply
4.5.3 Connector pin assignment IN signals of the fieldbox
PIN Colour* Signal Description
1 BN IN Input SD interface
2 WH Y1 Safety output 1
3 BU OUT Output SD interface
4 BK Y2 Safety output 2
4.5.4 Connector pin assignment OUT signals of the Fieldbox
PIN Colour* Signal Description
1 BN OUT Output SD interface
2 WH X1 Safety input 1
3 BU IN Input SD interface
4 BK X2 Safety input 2
* Color code of SCHMERSAL M12 accessory cables

6
Operating instructions
Passive fieldbox PFB-SD-4M12-SD
EN
4.6 Wiring example
I O
Power
2
1
3
4
I O
SD
I O
Power
2
1
3
4
I O
SD
O
N
1 8765432
Safety IN 2
Safety IN 1
0 VDC
+24 VDC
10A
SD-Out
0 VDC
+24 VDC
SD-Out
SD-In
FB
2
1231
231 4
I O
Power
2
1
3
4
I O
SD
O
N
1 8765432
O
N
1 8765432
BK (4)
BN (1)
WH (2)
WH (2)
BU (3)
BK (4)
BU (3)
BN (1)
PLC
Power supply
Safety-
monitoring
module
Safety
switchgear
- Fieldbox in the centre
JP & SW 7 + 8 OFF
- 4 devices connected
JP & SW 1 - 6 OFF
- Last eldbox
JP & SW 7 + 8 ON
- 3 devices connected
JP & SW 5 + 6 ON
- Fieldbox in the centre
JP & SW 7 + 8 OFF
- 2 devices connected
JP & SW 3 + 4 ON
SD Gateway
Terminals Optional
additional SD line

7
PFB-SD-4M12-SD
Operating instructions
Passive fieldbox
EN
4.6 Wiring example
I O
Power
2
1
3
4
I O
SD
I O
Power
2
1
3
4
I O
SD
O
N
1 8765432
Safety IN 2
Safety IN 1
0 VDC
+24 VDC
10A
SD-Out
0 VDC
+24 VDC
SD-Out
SD-In
FB
2
1231
231 4
I O
Power
2
1
3
4
I O
SD
O
N
1 8765432
O
N
1 8765432
BK (4)
BN (1)
WH (2)
WH (2)
BU (3)
BK (4)
BU (3)
BN (1)
PLC
Power supply
Safety-
monitoring
module
Safety
switchgear
- Fieldbox in the centre
JP & SW 7 + 8 OFF
- 4 devices connected
JP & SW 1 - 6 OFF
- Last eldbox
JP & SW 7 + 8 ON
- 3 devices connected
JP & SW 5 + 6 ON
- Fieldbox in the centre
JP & SW 7 + 8 OFF
- 2 devices connected
JP & SW 3 + 4 ON
SD Gateway
Terminals Optional
additional SD line

8
Operating instructions
Passive fieldbox PFB-SD-4M12-SD
EN
5. Set-up and maintenance
5.1 Functional testing
A check must be carried out to ensure that the projected safety function
is effective.
The security function, the configuration of the DP switch
and the jumper, as well as the proper installation, must be
checked by the responsible security expert / security officer.
5.2 Maintenance
The passive fieldbox operates error-free if installed and used properly.
6. Disassembly and disposal
6.1 Disassembly
Only disassemble the passive fieldbox if it is in de-energized state.
6.2 Disposal
Dispose of the passive fieldbox properly in accordance with national
regulations and laws.
7. Configuration
7.1 Configuration examples
3 configurations are shown respectively for the different SCHMERSAL devices. One configuration with long cable lengths (maximum),
one configuration with medium cable lengths (medium) and one configuration with shorter cable lengths (small).
The following assumptions are made for the configuration examples listed in the table:
• The examples represent maximum configurations. If individual cable lengths are shortened, larger systems are possible
• 2 x 1.5 mm² power supply wiring and 10 A fuse protection
• Use of SCHMERSAL cables
• The cable lengths listed in the table between power supply and the 1st field box, and between fieldboxes are maximum lengths.
Reducing the individual cable lengths is not critical.
Device / configuration
version
Max. number
of devices
Equals number
of fieldboxes
Length of the cable (A)
up to the 1st fieldbox
Length of the cables (B)
between the fieldboxes
Length of stub cables (C)
for device connection
AZM 200 / Maximum 16 4 10.0 m 10.0 m 7.5 m
AZM 200 / Medium 20 5 7.5 m 7.5 m 5.0 m
AZM 200 / Small 22 5.5 7.5 m 5 m 3.5 m
MZM 100 / Maximum 18 4.5 10.0 m 10.0 m 7.5 m
MZM 100 / Medium 22 5.5 7.5 m 7.5 m 5.0 m
MZM 100 / Small 26 6.5 7.5 m 5 m 3.5 m
AZM 300 / Maximum 24 6 10.0 m 10.0 m 7.5 m
AZM 300 / Medium 28 7 7.5 m 7.5 m 5.0 m
AZM 300 / Small 31 8 7.5 m 5 m 3.5 m
RSS & CSS / Maximum 31 8 10.0 m 10.0 m 7.5 m
RSS & CSS / Medium 31 8 7.5 m 7.5 m 5.0 m
RSS & CSS / Small 31 8 7.5 m 5 m 3.5 m
Mixed / Maximum 24 6 10.0 m 10.0 m 7.5 m
Mixed / Medium 28 7 7.5 m 7.5 m 5.0 m
Mixed / Small 31 8 7.5 m 5 m 3.5 m
Mixed fitting of fieldbox: 2 x MZM 100, 1 x AZM 300 and 1 x RSS / CSS
(A) (B)
(C)
(B)
(C) (C)
24 VDC
Power
Fieldbox Fieldbox Fieldbox
Devices Devices Devices
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal
Phone: +49 - (0)2 02 - 64 74 - 0
Telefax: +49 - (0)2 02 - 64 74 - 1 00
E-Mail: [email protected]
Internet: http://www.schmersal.com
Table of contents
Other schmersal I/O System manuals