FieldBus Input/Output System
■ModBus/TCP Network Adapter
■PROFIBUS Network Adapter
■Digital Input / Output
■Analog Input / Output
■Special Module
Quick Guide
FnIO S-series
NA-9189
1. NA-9189 Specification
* Specifications and designs could be changed without advance Notice
Class 2, adjacent to voltage rating (30Vmax.)
ITEM SPECIFICATION ITEM SPECIFICATION
Surrounding Air
Temp./
Ambient Temp. -20℃~55℃ / -40℃~85℃ Network Type Modbus/TCP
Relative Humidity 5% ~ 90% without condensation Cable EtherNet Cable(Shield Cable)
Durable-vib./impact IEC68-2-6(2G) / 10G Cable Length(m) Up to 100m from Ethernet Hub
EMC/ESD EN50082 / EN50081 Comm. Sp(Kbps) 10/100Mbps
Mount Position On the left of FnIO-S series Expansion No. Max. 32 module
Atmosphere Not so dusty without corrosive gas Max. node Limited by Ethernet Specification
Field Supp.Volt. Class 2, 24VDC
24VDC (11VDC ~ 28.8VDC)Max. Digital I/O Input :
2016points/Output:2016points
Field Supp. Cur. Max. 10A Max. Analog I/O Input : 126Ch / Output : 126Ch
FnBus Sup. Cur Max. 1.5A@5Vdc Max. Byte size Input : 252Bytes / Output : 252Bytes
Baud rate set Auto-negotiation Operation Mode 8 MODBUS/TCP, 4 HTTP, BOOTP.
Size 45mm ×99mm ×70mm IP Address setting Window Command, BOOTP
Weight 150g Power Dissipation 60mA typical @24Vdc
Certification UL / cUL / CE / FCC / DNV / LR /
RoHS(EU, China)
TCP/IP
Cautions for your Safety
Do not assemble the products and wire with power applied to the system. Else it may cause an electric arc, which can result into unexpected
and potentially dangerous action by field devices. Arching is explosion risk in hazardous locations. Be sure that the area is non-hazardous or
remove system power appropriately before assembling or wiring the modules.
Do not touch any terminal blocks or IO modules when system is running. Else it may cause the unit to an electric shock or malfunction.
Keep away from the strange metallic materials not related to the unit and wiring works should be controlled by the electric expert engineer.
Else it may cause the unit to a fire, electric shock or malfunction.
If you don’t follow the directions, it could cause a personal injury, damage to the equipment or explosion
If you disobey the instructions, there may be possibility of personal injury, damage to equipment or
explosion. Please follow below Instructions.
Check the rated voltage and terminal array before wiring. Avoid the circumstances over 55℃of temperature. Avoid placing it directly in the
sunlight.
Avoid the place under circumstances over 85% of humidity.
Do not place Modules near by the inflammable material. Else it may cause a fire.
Do not permit any vibration approaching it directly.
Go through module specification carefully, ensure inputs, output connections are made with the specifications. Use standard cables for wiring.
Use Product under pollution degree 2 environment.
Before using the unit
*We appreciate you for purchasing CREVIS Products. To use the units more effectively, please read this quick guide and refer to
the respective user manual for further details.
Warning!
Caution!
* Power Isolators must be used according to the usage of 5VDC/24VDC/48VDC or AC Voltage modules