The units described in these instructions are for use in a Standard UK Plug Socket,
they also feature a Standard UK Plug Socket on the front side of the product.
In the case of the RFRP-20, the front socket is provided as an additional socket
for convenience. The socket must remain switched on at all times in order for the
repeater to remain operational.
Supply Voltage: 230V~
Frequency: 868MHz
Minimum control distance: 20mm
Range uninterrupted: 200M
Ingress protection: IP20
Dimensions: 60 x 120 x 80mm
Applicable standards: EN607 30-1 ED.2
The Signal Repeater will extend the range between transmitters and receivers by up to 200M in free-air, and offer a solution in the
event building materials restrict the original signal sent. See the installation guidance notes supplied with this device.
Notes:
If more than one repeater is required for the same transmitter, the installer must ensure the signal going through the additional
repeaters does not transmit to the same receiver. This may confuse the receiver and cause false activation. To resolve the issue,
remove the pairings from additional repeaters, see section 3a below.
WARNING!
Please read through these steps before attempting to use the unit.
The instructions feature steps that must be carried out in quick succession.
An awareness of the steps beforehand will make this process easier.
Before you start; make sure all
receivers in the vicinity are in their
“off” state. Any receivers left on may
interfere with the programming of
the repeater.
Plug in the unit with the socket
power off.
While holding the “Status/Prog”
button, switch on the socket.
Continue holding the “Status/Prog”
button until the red indicator light
shows. Release the button. The
indicator light will flash green.
While the green light is flashing
press the “Status/Prog” button
again. The light should now
flash red for 5 seconds then no
light will appear. This indicates
the unit is in “Learning Mode”.
To Remove Pairings: (following on from step 3) If you press the “Status/Prog” button again, while the red light is flashing, it will clear
any stored pairings. The red light will illuminate for 5 seconds then clear, once all lights are off, press the “Status/Prog” button again to
confirm.
3a Programming / Learning Mode
1 RFRP-20 - Signal Repeater
1 2 3
2 Signal Range
Any device with the signs of damage and/or missing parts should NOT be installed and
should be returned to the seller.
Please refer to ‘Installation Guidance Notes’ supplied with the range of receiver before
commencing with the installation.
Devices are designed to be mounted internally only.
www.click-smart.com
If the address starts with: Change that number to:
0 8
1 9
2 A
3 B
4 C
5 D
6 E
7 F
If using a Smart Box (with app), RF Touch or
an RF Pilot you must go through an offset
procedure.
You must enter the address of the receiver
into the Smart Box (via the app) RF Pilot or
RF Touch but you must alter the address
according to the table below:
Once you have entered the address
into the Smart Box (via the app),
RF Touch or RF Pilot and while the
repeater is still in learning mode
(switched on but with no light
showing) use the remote control
(Smart Box via app, RF Touch or RF
Pilot) to switch the receiver on or off.
You will notice that the light on the
repeater blinks green if the unit has
been paired.
Move to step 6.
Once you have successfully paired
the devices, press the “STATUS/
PROG” button to switch to resume
normal operation. The green indicator
will be constantly illuminated.
You can link up to 20 devices per
repeater. When you have reached
the maximum number of devices the
green indicator on the repeater will
flash, then the red indicator will flash
and then constantly green.
5a 5b 6
For all bilateral control devices:
Examples:
An address of: 001C76 would change to:
801C76
An address of: 703E54 would change to:
F03E54
3c Programming / Learning Mode
3b Programming / Learning Mode
For pairing with basic switch transmitters as
shown below.
For sensor devices as shown below including
the PIR and window/door contacts
Still while no indicator lights are illuminated on the repeater;
use the control that is paired with the receivers you wish to
assign to the repeater. Press a button/switch on the control
to turn the receiver on. The repeater status light should flash
green once to indicate the pairing has been made.
Move to step 6
Still while no indicator lights are illuminated
on the repeater; insert the battery/batteries
into the product. The repeater status light
should flash green to indicate the pairing
has been made.
Otherwise move to step 6
4a 4b
Scolmore Park, Landsberg, Licheld Road Industrial Estate, Tamworth, Staffordshire B79 7XB
Tel: +44 (0) 1827 63454 Fax: +44 (0) 1827 63362 www.scolmore.com V1.1
If pairing these devices to a Smart Box, RF Touch or RF Pilot see step 5a below.

Popular Repeater manuals by other brands

1010music MX4 user guide

1010music

1010music MX4 user guide

Icom IC-FR3000 Series Remote control manual

Icom

Icom IC-FR3000 Series Remote control manual

Icom ID-RP1 instruction manual

Icom

Icom ID-RP1 instruction manual

PureLink PT-R-HD20 user manual

PureLink

PureLink PT-R-HD20 user manual

Compaq Netelligent 3024 user guide

Compaq

Compaq Netelligent 3024 user guide

Enik TRx 433 N quick start guide

Enik

Enik TRx 433 N quick start guide

Ksenia divide Installation and programming manual

Ksenia

Ksenia divide Installation and programming manual

Eminent EM4597 Quick install

Eminent

Eminent EM4597 Quick install

Lantronix LTR8T installation guide

Lantronix

Lantronix LTR8T installation guide

Hongxin GZF9003-V user manual

Hongxin

Hongxin GZF9003-V user manual

Uniden Force Preliminary service manual

Uniden

Uniden Force Preliminary service manual

OneVue Smart-Sync B100-R install guide

OneVue

OneVue Smart-Sync B100-R install guide

C&C TECHNIC Smart View Intelligent KVM-S1 user manual

C&C TECHNIC

C&C TECHNIC Smart View Intelligent KVM-S1 user manual

Danfoss CF-RU instruction manual

Danfoss

Danfoss CF-RU instruction manual

Kenwood TKR-750 instruction manual

Kenwood

Kenwood TKR-750 instruction manual

BEC 2090AC Quick install guide

BEC

BEC 2090AC Quick install guide

Cabletron Systems CXRMIM installation guide

Cabletron Systems

Cabletron Systems CXRMIM installation guide

ESD CAN-Repeater Hardware manual

ESD

ESD CAN-Repeater Hardware manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.