SERVICE MANUAL

HORIZONTAL INSTALLATION (RECOMMANDED)
450
622
383
A
A
BB
VERTICAL INSTALLATION
A
A
BB
314
408
180
1 FAN MOTOR 2 FAN MOTORS 3 FAN MOTORS
A mm 560 1340 1980
B mm 439 1139 1779
REFRIGERANT CHARGE R404A - Gr
MC 16 MC 16 SHORT MC 46 MF 56 MF 66 MF 86 MV 450 MV 600 MV 800 MV 1000
880 740 1375 1200 2700 5700 1200 1300 3000 3000

WEATHER PROOF AIR COOLED REMOTE
CONDENSER
The remote condenser versions of Cubers and
Flakers are similar to the air cooled standard
versions with the only difference of the remote
condenser and, on MC and MF series, of the Fan
Speed Control used to supply power to the fan
motor/s.
Technical specifications
1. Remote air cooled condenser fit on proper
brackets for horizontal and vertical
installation (MV series for vertical
installation only).
Cooling capacity with ΔT 15K is 4,5 KW
on MC 16/16 SHORT, MC 46, MF 56, MV
450 and MV 600; 6,0 KW on MV 800 and
MV 1000; 10,5 KW on MFE 61; 20,5 KW
on MF 83.
2. Fan motor/s 220-240/50-60/1 - 135 Watts
- 0,6 Amps with IP 44 protection (against
liquids and solids) and flow rate of 2150
m³/hr (2 motors on MF 66; 3 motors on
MF 86).
3. On MC and MF series only, an Electronic
Fan Speed Control set to 16 bar. On MV
series a standard ON-OFF hi pressure
control (15÷17 bars).
4. Pre-charged refrigerant lines of 10 meters
length equipped with AEROQUIP quick
connections.
5. Hi pressure safety control (manual reset
type) set to 34 bar on MC and MF series
(in place of the condenser temperature
sensor) and to 30 bar on MV series.
6. Hi pressure control warning light.
Installation of the remote air cooled condenser
and pre-charged refrigerant lines
A. Location considerations:
Select the best available place protected from
dirt/dust.
The weather proof remote air cooled condenser
can be installed indoor as well as outdoor and can
operate under the most different conditions (rain,
wing, snow, etc.)
Use the following formula for planning the location
of the condenser and ice machine.
Location Limits – Condenser location must
not exceed ANY of the following limits
Maximum vertical drop dd of 1 meter between the
icemaker and the remote condenser.
Maximum vertical rise rd of 3 meters.
Physical line set maximum length between
icemaker and remote condenser is 10 meters.
Limit to max. one rise and one drop.
Limit the calculated distance (CD) as per the
Calculation formula to 18 meters.
A = Drop = dd x 6.6
B = Rise = rd x 1.7
C = Horizontal run = hd x 1
CD = A + B + C
hd
dd
rd
Condenser Distance &
Location Schematic
Remote Condenser
located ABOVE Ice
Machine
Remote Condenser
located BELOW Ice
Machine

B. Unpacking and inspection:
Visually inspect the exterior of the shipping
container; any severe damage should be reported
to the delivery carrier.
Uncrate the remote condenser and pre-charged
refrigerant lines and inspect for any concealed
damage. Notify carrier of any cancealed damage.
Check that the pre-charged refrigerant lines are
intact, not kinked.
C. Remote condenser installation
Install and attach the remote condenser to the
floor or to the wall of the building using methods
and practices conform to the local building
requirements.
Remove the control box cover from the remote
condenser and connect the electrical power line
coming from the unit following the wires colors.
NOTE. Cable connecting the unit to the remote
condenser is at 230 Volts so it is imperative to
have the cable properly protected inside a plastic
or metal tube according to the local electrical
code/standard.
D. Pre-charged refrigerant lines
The set of pre-charged refrigerant lines consists
of the 3/8" O.D. self sealing gas line and 1/4" O.D.
self sealing liquid line both equipped with 1-20"
UNEF AEROQUIP quick connections on MC
16/16 SHORT, MC 46, MF 56, of 12 mm and 8
mm O.D. on MV 450-600 and 14 mm and 12 mm
O.D. on MV 800-1000.
On models MF 66 the pre-charged refrigerant
lines are 1/2" O.D. gas line and 3/8" O.D. liquid
line both equipped with 1-20" UNEF AEROQUIP
quick connections.
On model MF 86 only, 16 mm O.D. gas line and
12 mm O.D. liquid line with AEROQUIP quick
connections too.
Whenever the length of the pre-charged
refrigerant lines are longer then the distance
between the ice maker and the remote condenser
keep the excess portion indoor shaped as a
vertical spiral so to avoid refrigerant trapping.
CAUTION. Each coupling on the pre-charged
refrigerant lines is self-sealed and should be
tightened 1/4 turn more then snug tight.
ALWAYS USE TWO WRANCHES WHEN
TIGHTENING THESE FITTINGS, ONE AS
BACKUP WRENCH TO PREVENT TWISTING
OF TUBING AND POSSIBLE KINKING OR LINE
RUPTURE.
Connect the gas line coupling to the remote
condenser refrigerant fitting (labeled GAS) and to
the refrigerant fitting on the rear side of the ice
machine.
Connect the liquid line coupling to the remote
condenser refrigerant fitting (labeled LIQUID) and
to the refrigerant fitting on the rear side of the ice
machine.
ATTENTION. The inlet of the remote air cooled
condenser (gas) must be always located
above the outlet (liquid) for both horizontal
and vertical installations.
Operating instructions
The remote air cooled condenser versions of
Cubers and Flakers are operating in the same
way as the standard machine.
The only difference is the operation of the fan
motor on MC and MF series as on the remote
condenser versions it is no longer possible to use
the condenser sensor to control the ON-OFF
operation of the same.
In place of the condenser sensor has been
installed an electronic fan speed control (set up at
16 bar by its adjusting screw) and a manual reset
type hi pressure control.
The fan speed control supplies a variable power
to the fan motor so to modulate its speed and
keep to a constant value the discharge pressure.
The hi pressure control is used only as a safety
device to switch OFF the operation of the machine
in case of fan motor failure.
MC 16-16 SHORT
MC 46 - MF 56 MV 450-600 MV 800-1000 MF 66 MF 86
Remote air cooled condenser & fan motor assy 620418 00 620418 00 CM 19177506 620418 01 620418 02
Fan motor assy - LU.VE.-CONTARDO 001028 30 001028 30 001028 30 001028 30 *****
Fan motor assy - ECO 001028 32 ***** ***** 001028 32 001028 32
Hi pressure control (safety) 620498 00 620231 01 620231 01 620498 00 620498 00
Fan speed control/Electronic device 620500 00 ***** ***** 620500 00 620500 00
Fan pressure control ***** CM 19550624 CM 19550624 ***** *****
Low pressure control ***** ***** ***** ***** 620451 00
Liquid receiver ***** CM 19635339 CM 19635354 ***** *****
AEROQUIP male connection - LIQUID 650438 01 650438 01 650438 01 650438 00 650438 00
AEROQUIP female connection - LIQUID 650437 01 650437 01 650437 01 650437 00 650437 00
AEROQUIP male connection - GAS 650438 01 650438 01 650438 01 650438 00 650438 05
AEROQUIP female connection - GAS 650437 01 650437 01 650437 01 650437 00 650437 05


SCK1
VALVES
HOT GAS
ELETTROVALVOLE
GAS CALDO
SENSOR
BIN FULL
SENSORE
CONT. PIENO
PER MC46
ACQUA INGRESSO ACQUA
ELETTROVALVOLEPOMPE
VENTILATORE
SENSOR
EVAP. TEMP.
COMPRESSORE
FOR MC46
FAN
WATER
COMPRESSOR
WATER INLET
SENSORE
TEMP. EVAP.
VALVESPUMPS
MOTOR
SCARICO ACQUA
ELETTROVALVOLE
WATER DISCHARGE
VALVES CRANCKCASE HEATER
RESISTENZA COMPRESSORE
SWITCH
HI PRESSURE
PRESSOSTATO
DI ALTA
SENSOR
COND. TEMP.
SENSORE
TEMP. COND.


SCK1
VALVES
HOT GAS
ELETTROVALVOLE
GAS CALDO
SENSOR
BIN FULL
SENSORE
CONT. PIENO
PER MC46
ACQUA INGRESSO ACQUA
ELETTROVALVOLEPOMPE
VENTILATORE
SENSOR
EVAP. TEMP.
COMPRESSORE
FOR MC46
FAN
WATER COMPRESSOR
WATER INLET
SENSORE
TEMP. EVAP.
VALVESPUMPS
MOTOR
PER I MODELLI SENZA NEUTRO
MODEL WITHOUT NEUTRAL
SCARICO ACQUA
ELETTROVALVOLE
WATER DISCHARGE
VALVES CRANCKCASE HEATER
RESISTENZA COMPRESSORE
SWITCH
HI PRESSURE
PRESSOSTATO
DI ALTA
TEMP. COND.
SENSORE
COND. TEMP.
SENSOR





EV1 FAN motor
Ventilatore
EV2 FAN motor
Ventilatore
EV3 FAN motor
Ventilatore
F1 3-phase monitoring relay
controllo sequenza fasi
FC1 Spout switch
Interruttore bocchetta
FSC1 Fan Speed
Fan Speed
HL1 Power ON
Macchina in funzione
HL2 HI pressure alarm
Allarme alta pressione
HL3 LOW pressure alarm
Allarme bassa pressione
HL4 Water alarm
Allarme mancanza acqua
HL5 Spout switch light
Spia interruttore bocchetta
HL6 Bin full
Magazzino pieno
HL7 Wrong phase alarm
Allarme sequenza fasi
HL8 Current drive-motor alarm
Allarme amperometrica motoriduttore
HL9 Compressor thermal protector alarm
Allarme protezione termica compressore
KA1 Current drive-motor relay
Relè amperometrico motoriduttore
KA3 Drive-motor start relay
Relè anticipata motoriduttore
KM1 Compressor contactor
Teleruttore compressore
KM2 Drive-motor contactor
Teleruttore motoriduttore
KT1 Compressor timer delay
Ritardatore compressore
KT2 Drive-motor timer delay
Ritardatore motoriduttore
M1 Compressor
Compressore
M2 Drive motor
Motoriduttore
R1 Cranckcase heater
Resistenza compressore
SA1 Switch
Interruttore
SB1 Reset push button
Pulsante reset
SP2 HI pressure control safety
Pressostato sicurezza alta pressione
SP3 Water pressure control
Controllo bassa pressione acqua
SP4 LOW pressure control
Pressostato basa pressione
ST1 Thermostat
Termostato
TM1 Compressor thermal relay
Relè protezione termica compressore
TM1 Compressor thermal protector
Protettore termico compressore

This manual suits for next models
9
Table of contents
Popular Heat Pump manuals by other brands

Nibe
Nibe F1126 Service manual

Mitsubishi Electric
Mitsubishi Electric Trane TPCA0A 1KA70 Series Operation manual

Lennox
Lennox XP19 installation instructions

Dimplex
Dimplex SI 5MER Installation and operating instructions

Estia
Estia HWS-2101CSHM3-E installation manual

ML ELECTRONICS
ML ELECTRONICS MegaLife ML-RS-Dm30/NaA-M owner's manual