manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Shield-Kon
  6. •
  7. Power Tools
  8. •
  9. Shield-Kon ERG740 User manual

Shield-Kon ERG740 User manual

10
90
80
70
60
50
40
30
20
0
D 101
FIGURE 1
TABLE 1
(1.27 - 1.79 mm) .050 - .070 in.
(1.80 - 2.28 mm) .071 - .089 in.
(2.29 - 2.55 mm) .090 - .100 in.
(3.01 - 3.34 mm) .119 - .131 in.
(2.56 - 3.00 mm) .101 - .118 in.
(3.35 - 3.65 mm) .132 - .143 in.
(3.66 - 4.13 mm) .144 - .162 in.
(4.14 - 4.71 mm) .163 - .185 in.
(4.72 - 5.12 mm) .186 - .201 in.
(5.13 - 5.86 mm) .202 - .230 in.
(5.87 - 6.36 mm) .231 - .250 in.
(6.37 - 7.00 mm) .251 - .275 in.
(7.01 - 7.62 mm) .276 - .300 in.
DIAMETER OF SHIELD CONNECTOR CAT.
NO. & CODE
RSK101 or
RSK5101
RED
RSK201 or
RSK5201
BLUE
RSK301 or
RSK5301
YELLOW
RSK401 or
RSK5401
GREEN
1 OR 2 PIECES 0.25mm
#24 AWG STR
OR 1
#22 AWG STR
1 OR 2 PIECES 0.25mm
#22 AWG STR
or 1 PIECE 0.5mm
#20 AWG STR
1 OR 2 PIECES 0.25mm
#22 AWG STR
1 PIECE 0.5mm OR 2
#20 AWG STR
1 OR 2 PIECES 0.5mm
#20 AWG STR
or 1 PIECE 0.75mm
#18 AWG STR
DIE CAT. NO
(STEEL)
D-301G
D-301J
D-401N
D-401M
D-401L
D-401K
D-301H
D-201F
D-201E
D-201D
D-201C
D-101B
D-101A
GROUND WIRE
RANGE
ERG740 ERGONOMIC HAND TOOL
OPERATING INSTRUCTIONS
for RSK Series Wrap Around Connectors
IMPORTANT: Read and understand all of the instructions and safety information in this
manual before operating or servicing this tool.
INTENDED USE:
Wrap around connectors have been designed to ground the shield of single
or multiple conductor shielded cables. It Is suggested that the customer evaluate the suitability
of these connectors and verify their performance for the particular application .
WARNING
KEEP ALL BODY PARTS AWAY FROM DIE NEST
DURING GAGING OR CRIMPING PROCEDURE.
WARNING
HANDLES ARE NON-INSULATING.
DO NOT CRIMP ON HOT ENERGIZED WIRES.
OPERATING INSTRUCTIONS
MATCHING THE CONNECTOR AND DIE TO THE CABLE
1
1.
Measure the diameter of the cable shield using a calibrated
measuring tool or the RSK gauge (part number RSK-LEHRE)
which is in the tool case lid. Rotate the cable in order to
locate the maximum shield diameter. Exert only light
pressure on the cable to get an accurate measurement, see
Figure. 1.
When using the RSK gauge , try to nd the appropriate slot
in the gauge by ensuring that the cable only goes in the top
of the slot. If the cable goes completely to the bottom of
the slot, you should try the cable in the smaller adjacent
slot.
Once you nd the appropriate slot, you can read the
associated RSK connector by the color of the slot and the
appropriate die by the number marked below the slot.
2. For twisted pair and other non-symmetrical shielded
cables, measure the dimension of the major axis or the
largest width of the cable.
When you use the RSK gauge, try to nd the appropriate
slot in the gauge by tting the largest width of the cable
into the slot. Similar to step 1, if the cable goes completely
to the bottom of the slot, try the next smaller adjacent slot.
3. Once the shield diameter is established, refer to Table 1 for
the appropriate connector and installing die.
TA04632 B Page 1 of 2
CAT. No. DIM. (mm) TOL.
D-101A 3.6 mm ±0.10 mm
D-101B 3.9 mm ±0.10 mm
D-201C 4.4 mm ±0.10 mm
D-201D 4.6 mm ±0.10 mm
D-201E 4.9 mm ±0.10 mm
D-201F 5.1 mm ±0.10 mm
D-301G 6.2 mm ±0.10 mm
D-301H 6.5 mm ±0.10 mm
D-301J 6.8 mm ±0.10 mm
D-401K 8.0 mm ±0.10 mm
D-401L 8.2 mm ±0.10 mm
D-401M 8.8 mm ±0.10 mm
D-401N 9.1 mm ±0.10 mm
1. Open the tool handles completely
to fully retract the ram.
2. Insert the stem of upper die into
the tool frame.
3. Insert the separation spring of the
lower die into the upper die
opening. Push up rmly, and
insert the lower die stem into the
hole in the ram.
NOTE:
These connectors
should not be used with
multi-conductor shielded
cables whose conductors are
solid or stranded bonded wire.
1. Remove the cable jacket
as required and prepare
the shield as shown in the
standard method
illustration.
2. When the cable inner
conductor insulation is
vinyl of .015 in, or less
thickness or Teon* of
.010 in. or less thickness,
use foldback method 1 or
2 as ilIustrated.
3. When the shield is foil or is
spiral wrapped, use
foldback method 2.
4. When using either
foldback method, be sure
to measure the diameter
of the shield after it is
folded back. Refer to
Table 1 for proper die
selection.
*Teon is a registered
trademark of E.I. Du Pont De
Nemours and Company
1. For a single ground wire. strip the wire 7/16 in (11mm) and
twist the strands together.
2. For two ground wires. strip each wire 1/2 in. (12mm) and twist
the two wires together.
3. If hairpinning (hooking) the ground wire is desired, strip the
wire 1/2 in . (12mm) and bend it as shown. Use one die size
larger.
1. Insert the connector, with the ground trap facing up, into the
nest area of the die. Be sure to center the connector.
2. Place the ground wire into the ground trap and the shielded
cable into the bottom to the connector. Be sure to butt the
cable jacket and the ground wire insulation against the metal
connector edge. The ground wire can exit from either direction.
3. Squeeze the tool handles completely to form the connector
around the shield.
INSTALLING THE DIES IN THE
ERG740 TOOL
1. Install the die set into the
ERG740 Tool.
2. Close the tool handles until the
die faces are touching.
3. Using calipers, measure the die
nest height and compare to the
die gauging chart to ensure die
nest opening is within the
specied tolerance range.
GAUGING THE DIES
CABLE PREPARATION
GROUND WIRE PREPARATION
INSTALLING THE CONNECTOR
ON SHIELDED CABLE
Thomas & Betts Corporation
Memphis, Tennessee
www.tnb.com TA04632 B Page 2 of 2© 2011 Thomas & Betts. All Rights Reserved.
For Parts or Service, contact the Thomas & Betts Tool Service Center at
1-800-284-TOOL (8665).
WARRANTY: Thomas & Betts sells this product with the understanding that the user will
perform all necessary tests to determine the suitability of this product for the user's intended
application. Thomas & Betts warrants that this product will be free from defects in materials
and workmanship for the period stated on the enclosed warranty card. Upon prompt
notication of any warranted defect, Thomas & Betts will, at its option, repair or replace the
defective product or refund the purchase price. Proof of purchase is required. Misuse or
unauthorized modication of the product voids all warranties.
Limitations and Exclusions: THE ABOVE WARRANTY IS THE SOLE WARRANTY
CONCERNING THIS PRODUCT, AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE
SPECIFICALLY DISCLAIMED. LIABILITY FOR BREACH OF THE ABOVE WARRANTY IS
LIMITED TO COST OF REPAIR OR REPLACEMENT OF THE PRODUCT, AND UNDER NO
CIRCUMSTANCES WILL THOMAS & BETTS BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES.
CAUTION
Do not solder dip the ground wire ends.
Do not use solid ground wire.
CAUTION
During all stripping operations, use extreme care to
prevent nicking or cutting of the shield or inner
conductor insulation. This could result in short circuits.
CAUTION
Be sure that neither the cable outer jacket nor the
ground wire insulation is under the metal portion of
the connector. This will overload the dies.
D 101 A
SHIELD
JACKET COND. DIELECTRIC
AS
REQ.
7/16 in. (11 mm)
STANDARD METHOD
SHIELD COND. DIELECTRIC
AS
REQ.
7/16 in. (11 mm)
JACKET
FOLDBACK METHOD 1
SHIELD ROLLED BACK
COND. DIELECTRIC
AS
REQ.
JACKET
FOLDBACK METHOD 2
2
3
4
5
UPPER DIE STEM
UPPER DIE
SEPARATION
SPRING
LOWER DIE STEM
LOWER DIE
RAM
NEST AREA
6
HAIRPIN GROUND WIRE
GROUND
WIRE
NOTE: DO NOT FORM OR BEND
GROUND LEAD TRAP
INSULATION
1/4 in. (6 mm)
GROUND WIRE
GROUND TRAP
CABLE
Ground Wire
Dies
Dies
Cable
Connector
GROUND TRAP
D 101 A

This manual suits for next models

1

Popular Power Tools manuals by other brands

Cornwell Tools CAT9000HS operating manual

Cornwell Tools

Cornwell Tools CAT9000HS operating manual

Metabo KS 216 M Lasercut Original instructions

Metabo

Metabo KS 216 M Lasercut Original instructions

Shock Line MA PREGI 35N1 Operating and maintenance instructions

Shock Line

Shock Line MA PREGI 35N1 Operating and maintenance instructions

Kemper 1058KIT user manual

Kemper

Kemper 1058KIT user manual

Craftsman 235.199140 owner's manual

Craftsman

Craftsman 235.199140 owner's manual

Lund Rampage 86645 installation instructions

Lund

Lund Rampage 86645 installation instructions

K-Tool KTI63619 owner's manual

K-Tool

K-Tool KTI63619 owner's manual

Bosch PST 7000 E Original instructions

Bosch

Bosch PST 7000 E Original instructions

Laguna Tools T800i operating manual

Laguna Tools

Laguna Tools T800i operating manual

Sharper Image 205397 user guide

Sharper Image

Sharper Image 205397 user guide

YATO YT-09618 Original instructions

YATO

YATO YT-09618 Original instructions

VERTO 52G057 instruction manual

VERTO

VERTO 52G057 instruction manual

JAMEC PEM TDR3000 instruction manual

JAMEC PEM

JAMEC PEM TDR3000 instruction manual

Weller Micro WXPP Translation of the original instructions

Weller

Weller Micro WXPP Translation of the original instructions

Yokota YX-380SA manual

Yokota

Yokota YX-380SA manual

9circle 9CL-11070 instruction manual

9circle

9circle 9CL-11070 instruction manual

Makita WT02 instruction manual

Makita

Makita WT02 instruction manual

DGSHAPE CA-DK2 user manual

DGSHAPE

DGSHAPE CA-DK2 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.