Content
1 INTRODUCTION.........................................4
1.1 Producer and service .................................... 4
............. 4
1.3 Intended use ................................................. 4
1.4 Improper use................................................. 4
1.5 Maintenance and service notes.................... 4
..... 4
1.7 Dimensions ................................................... 4
1.8 Symbols used ................................................ 4
........................ 4
1.10 Applicable documents................................... 5
1.11 Appropriate disposal..................................... 5
2 SAFETY.......................................................5
2.1 Structure of the warning notes..................... 5
2.2 Warning notes used ...................................... 5
2.3 Warning notes............................................... 5
3 FUNCTIONS................................................6
3.1 IO module ..................................................... 6
3.2 IO module smart ........................................... 6
4 CONNECTION DIAGRAM IO-MODUL
IO-MODUL SMART WITH DRIVE CL...........7
5 OPERATION................................................7
.......................................... 7
........................................... 8
5.3 Menu structure IO module ........................... 9
..................................................... 10
5.4.1 Volume of the buzzer.................................. 10
....................... 10
...................... 11
...................... 11
5.4.5 Adjustment of switching mode
for Out 1 to 3............................................... 11
................................... 12
................................... 12
5.4.8 Device services............................................ 13
5.4.9 System services ........................................... 13
5.4.10 WIFI (only for IO module smart) ................. 14

for DRIVE CL Operang instrucons
IO module/IO module smart
09.20214/16 H47.MOTS017EN-00
1 Introducon
begin the assembly work. Observe the notes in Chapter
2 "Safety", in order to prevent personal injury or
point lock and must be accessible to the specialist
1.1 Producer and service
KFV Karl Fliether GmbH & Co. KG
A company of the SIEGENIA GROUP
Siemensstraße 10
42551 Velbert
Tel.: +49 2051 278-0
Fax: +49 2051 278-167
E-mail: info@kfv.de
Please contact your contractual partner in case of
1.2 Target group of this documentaon
1.3 Intended use
• The IO module/IO module smart serves as an
DRIVE CL.
• The IO module/IO module smart is intended for
indoor use (IP20) with a room temperature of 0°C to
boxes or surface mounted in approved branch boxes.
•
• Use the IO module/IO module smart only when it is
• Repair of the IO module/IO module smart is not
permissible. The IO module/IO module smart must
be replaced in case of faults.
1.4 Improper use
• The IO module smart must not be installed in a
metal casing, as this could lead to shielding of the
WIFI signal.
• The IO module/IO module smart must not be used
in event of air humidity > 80 %. The device is not
approved for use in swimming pools and/or wet
• The IO module/IO module smart and its connected
electromechanical components must not be
1.5 Maintenance and service notes
Never use cleaning agents that are aggressive or
contain solvents. This could damage the surfaces of the
components.
1.6 Installaon condions and requirements
1.7 Dimensions
All measurements are given in mm.
1.8 Symbols used
The following pictograms are used in this document:
general warning symbol
the corresponding point
The following symbols for the LEDs are used in this
document:
LED lights up
indicated colours
1.9 Other types of presentaons
their meanings:
• Items of text following this marker are found in lists.
– Items of text following this marker are found in
subordinate lists.
fItems of text with this marking in front of them are
order.
Cross reference
brackets.

5/16
Operang instrucons for DRIVE CL
IO module/IO module smart
5/1609.2021H47.MOTS017EN-00
1.10 Applicable documents
components.
1.11 Appropriate disposal
Electrical devices should not be disposed of as house-
hold waste. Bring the device, accessories and packaging
to an environmentally-friendly recycling facility.
2 Safety
• All work on the 230 V AC mains power supply
must be carried out in compliance with the current
•
•
•
electronics.
2.1 Structure of the warning notes
•
personal injury and material damage,
• classify the level of danger by the signal word,
• designate the danger of personal injury via the
hazard sign,
•
• show measures to prevent danger and prohibit
The warning notes are set up according to the following
principle:
SIGNAL WORD
Type and source of danger
•
of personal injury.
due to electric shock.
2.2 Warning notes used
DANGER
The signal word "Danger" designates an immediately
threatening danger. If this danger is not prevented, it
leads to death or severe injuries.
WARNING
danger. If this danger is not prevented, it could lead to
death or severe injuries.
CAUTION
prevented, it could lead to minor or moderate injuries.
NOTE
these notes prevents damage to the components.
This symbol indicates special features and designates
2.3 Warning notes
DANGER
Risk of fatal injury from electric shock
Exposed electrical components
• All work on a 230 V AC mains power supply may only be
If energy-carrying cables are routed in parallel to data
cables (ISDN, DSL, etc.), this could lead to interference e.
g. in the speed of the data transmission.

for DRIVE CL Operang instrucons
IO module/IO module smart
09.20216/16 H47.MOTS017EN-00
3 Funcons
3.1 IO module
•
locking drive DRIVE CL
•
•
•
•
•
3.2 IO module smart
• Extension of the WIFI-capable control for the
SIEGENIA Comfort app
(available free of charge from Google Play Store or
Apple App Store)
•
locking drive DRIVE CL
•
•
•
•
•
•
•
•

7/16
Operang instrucons for DRIVE CL
IO module/IO module smart
7/1609.2021H47.MOTS017EN-00
4 Connecon diagram IO-ModulIO-Modul smart with DRIVE CL
Item name
1 DRIVE CL
2 IO-Modul/IO-Modul smart
3 Power supply
4
1
2
3
4
5 Operaon
5.1 Buons and LEDs
Item name
1
2 Menu LED
3 WIFI LED (only for IO module smart)
4 Status LED
4
1 2 3

for DRIVE CL Operang instrucons
IO module/IO module smart
09.20218/16 H47.MOTS017EN-00
5.2 Menu navigaon
9).
1.
(menu LED lights up in 1 colour).
+24 V
–
1
2
3
4
5
6
7
8
9
10
Input 1
Input 2
Out 1
Out 2
Out 3
2.
+24 V
–
1
2
3
4
5
6
7
8
9
10
Input 1
Input 2
Out 1
Out 2
Out 3
3 s
3.
+24 V
–
1
2
3
4
5
6
7
8
9
10
Input 1
Input 2
Out 1
Out 2
Out 3
4.
adjustment.
+24 V
–
1
2
3
4
5
6
7
8
9
10
Input 1
Input 2
Out 1
Out 2
Out 3
3 s
5.
further input on the IO module follows.

9/16
Operang instrucons for DRIVE CL
IO module/IO module smart
9/1609.2021H47.MOTS017EN-00
5.3 Menu structure IO module
Volume of
the buzzer
Out 3 Device
services
System
services 1)
100 % Restart the
device
Couple
devices
Level 2 Level 1
75 % Default
Separate
devices
(50 %) (Funcon R) SW version Unblock ACS
25 % Factory
0 % WIFI on
Out 1
(Funcon P)
Out 2 Out 1–3
Switching mode
Input 1 Input 2 WIFI
(Locking
bolt)
(Funcon 13) (Funcon 14) Reset WIFI
(Funcon Q) N/C contact
WPS mode
Some menu items under „System services“ and „WIFI“ can only be carried with a WIFI-capable device that is integrated in the SI-BUS system. The
The "System services" menu can be retrieved up to 10 minutes following the system start. The "WIFI" menu can be retrieved up to 5 minutes
following the system start
The default values on delivery are displayed in bold italics in brackets (example: (50%)).

for DRIVE CL Operang instrucons
IO module/IO module smart
09.202110/16 H47.MOTS017EN-00
5.4 Funcons
5.4.1 Volume of the buzzer
LED colour in
level 1
Alternang LED colours
in level 2 value Descripon
Magenta
Magenta/
White 100 % The volume of the buzzer is set to 100 %.
75 % The volume of the buzzer is set to 75 %.
Magenta/
Orange (50 %) The volume of the buzzer is set to 50 %.
Magenta/
Red 25 % The volume of the buzzer is set to 25 %.
Magenta/
0 % The volume of the buzzer is set to 0 %.
5.4.2 Feedback funcon for Out 1
LED colour in
level 1
Alternang LED colours
in level 2 Funcon Feedback
yellow
Yellow/
White (P)
The window is closed and locked.
Yellow/
Orange R
Depending on the selected adjustment:
• Close WITH locking:
the window is closed and locked.
• Close WITHOUT locking:
the window is closed but not locked.
Yellow/Red S The window is unlocked and open.
Yellow/
F

11/16
Operang instrucons for DRIVE CL
IO module/IO module smart
11/1609.2021H47.MOTS017EN-00
5.4.3 Feedback funcons for Out 2
LED colour in
level 1
Alternang LED colours
in level 2 Funcon Feedback
Light green
Light green/
White U
Light green/
(Q) The window is closed and locked.
Light green/
Orange R
Depending on the selected adjustment:
• Close WITH locking:
the window is closed and locked.
• Close WITHOUT locking:
the window is closed but not locked.
Light green/
Red S The window is unlocked and open.
Light green/
I AS soon as the voltage at the terminals of the device is switched ON.
5.4.4 Feedback funcons for Out 3
LED colour in
level 1
Alternang LED colours
in level 2 Funcon Feedback
Dark blue
Dark blue/
White V
Dark blue/
The window is closed and locked.
Dark blue/
Orange (R)
Depending on the selected adjustment:
• Close WITH locking:
the window is closed and locked.
• Close WITHOUT locking:
the window is closed but not locked.
Dark blue/
Red S The window is unlocked and open.
Dark blue/
T
5.4.5 Adjustment of switching mode for Out 1 to 3
LED colour in
level 1
Alternang LED colours
in level 2 Command Descripon
Orange
Orange/
White (Locking bolt) Out 1 and Out 2 react as locking bolts when the status is reached.
N/C contact Out 1 and Out 2 react as openers when the status is reached.

for DRIVE CL Operang instrucons
IO module/IO module smart
09.202112/16 H47.MOTS017EN-00
5.4.6 Funcons for input 1
LED colour in
level 1
Alternang LED colours
in level 2 Funcon Descripon
Vanilla
Vanilla/
White (13) Input 2 on the IO module behaves analogue to input 1 on the DRIVE CL.
15
vent
Vanilla/
Orange 16
Vanilla/Red 17
Vanilla/
22
closes the window again. The drive locks the window only when „Silent Mode OFF“ is
set (adjustment on the DRIVE CL).
Comfort app ( IO-Modul smart only).
Vanilla/
Violet 24
Toggle mode:
•
2. the drive stops
3. the drive closes and locks the window
•
5.4.7 Funcons for input 2
LED colour in
level 1
Alternang LED colours
in level 2 Funcon name Descripon
Dark green
Dark green/
White (14) Input 2 on the IO module behaves analogue to input 2 on
the DRIVE CL.
Dark green/
18 Close
The drive begins the closing process and stops if closing
without locking has been set.
This command must be repeated to close completely.
Dark green/
Orange 19 Closing and locking The drive always locks completely EVEN when closing
without locking has been set
Dark green/
Red 20 Stop or lock
and then the sash closes and locks
Dark green/
23
locks it.
changed with the SIEGENIA Comfort app ( IO-Modul smart
only).
Dark green/
Violet 21 Holiday mode
Closing and locking the window is only possible 1x.

13/16
Operang instrucons for DRIVE CL
IO module/IO module smart
13/1609.2021H47.MOTS017EN-00
5.4.8 Device services
LED colour in
level 1
Alternang LED colours
in level 2 Command Descripon
Light blue
Light blue/
White
Restart the
device
The device restarts without the voltage having to be switched OFF and ON again
(reboot)
Light blue/
Light blue/
Orange SW version The SW version is issued via a colour LED code.
5.4.9 System services
Some menu items under „System services“ can only be carried with a WIFI-capable device that is integrated in the SI-BUS system. The menu items
The "System services" menu can be retrieved up to 10 minutes following the system start.
LED colour in
level 1
Alternang LED colours
in level 2 name Descripon
Bright red
Bright red/
white Couple devices
All devices connected via the SI-BUS are successively integrated into the system. This
device is then the master device. All devices that are successfully connected signalise
this by a beep tone.
Separate
devices
All devices that are no longer connected to the SI-BUS will be removed from the SI-
separated may no longer be physically connected to the SI-BUS.The devices that are to
to the master any longer)
Light red/
Orange Unblock ACS
Light red/
Red
• all device couplings
•
• all device names
• all system names
•
Light red/
WIFI on If the WIFI switches ON, the SIEGENIA Comfort APP can be used. WIFI ON is the default
Bright red/
Violet If the WIFI switches OFF, the SIEGENIA comfort app can NOT be used.

for DRIVE CL Operang instrucons
IO module/IO module smart
09.202114/16 H47.MOTS017EN-00
5.4.10 WIFI (only for IO module smart)
Some menu items under „WIFI“ can only be carried with a WIFI-capable device that is integrated in the SI-BUS system. The menu items are always
The "WIFI" menu can be retrieved up to 5 minutes following the system start
LED colour in
level 1
Alternang LED colours
in level 2 name Descripon
red
Red/White Reset WIFI
without password)
WPS mode
The standard WPS coupling to the home network can be carried out via this menu item
from the home WIFI.

Other manuals for DRIVE IO-Modul
1
This manual suits for next models
1
Table of contents
Popular I/O System manuals by other brands

Pilz
Pilz PSS u2 ES 8DID operating manual

Contec
Contec DIO-4/4(FIT)GY specification

National Instruments
National Instruments 6711 user manual

National Instruments
National Instruments PXIe-4480 CALIBRATION PROCEDURE

HomeMatic
HomeMatic HmIPW-FIO6 Installation instructions and operating manual

Advantech
Advantech PCI-1713 user manual