Installation Instructions Specifications are subject to change without notice Page 1
Inline Extraction Fan Kits - 150mm Contour
Thank you for purchasing this quality 150mm inline extraction fan kit.
To ensure correct function and safety, please read all instructions before using the product and keep all instructions for future reference.
Description Order Code
Standard Switching FAN7044
When using electrical appliances, basic safety precautions should always
be followed to reduce the risk of fire, electrical shock and personal injury.
This Manrose inline extraction fan kit is designed for ventilation within a shower
cubicle. The high performance fan provides high levels of extraction and enables
additional ducting to be added to this system.
ABCD
200 143 170 185
DIMENSIONS A C
BD
SPECIFICATIONS
Duct
(mm) Fan Type
Max.
Fan Watts
(W)
Max.
Fan Pressure
(PA)
Free Air Fan Performance Specific
Fan Power
(W/l/s)
Interior Grille Exterior Grille
(l/s) (m3/hr)
150 EC Axial 18 91 105 380 0.17 Range Selection Fixed Louvre White
Note: Grille cut-out size is a nominal diameter for a circular cut-out.
TECHNICAL
Supply Motor Housing Impeller & Outer Rotor Ducting
220-240V AC, 50Hz Die cast aluminium PBT plastic 5m Flexible PVC
Adapter Plate
Round Square
White Black LED White LED Black White Black LED White LED Black
DCT4502 DCT4503 DCT4506 DCT4507 DCT4504 DCT4505 DCT4508 DCT4509
Fascia Selections (sold separately)
Compliance: AS/NZS60335-2.80:2016
FAN TIMER SELECTION
Please use the FAN2444 fan timer model shown Do not use old model FAN2444 (with resistor) or FAN0372 fan timers

Installation Instructions Specifications are subject to change without notice Page 2
Inline Extraction Fan Kits - 150mm Contour
REGULATIONS AND STANDARDS
Choosing the Right Fan to Comply
Fans cannot be selected on the basis of free-air performance only. Fans must now be selected on the basis of the complete installed system
performance for a designated room as per the table below.
1) Toilets only require ventilation if they have no openable windows
2) Simx recommends 40 l/s for laundries with unvented non-condensing tumble dryers as covered in AS 1668: Part 2 2012
Recent unregulated extract fan practices in New Zealand has trended to basic, low pressure axial fan products, as installed system performance has
not been defined for independent inspection testing and compliance signed off by local authorities.
New Zealand Building Code and Healthy Homes
The following two category requirements have been established for mandatory extraction ventilation in New Zealand.
The New Zealand Building Code for New Building Consents
The building regulatory system sets out a framework to promote good quality decisions being made during the Building Consent process. The
legislation and regulations work together, as the building regulatory system. The functional clauses of the NZ Building Code are grouped and
described by a letter and number. Clause G of the NZ Building Code covers services, with G4 setting out the performance requirements for
ventilation. The Building Code is enshrined in law. The New Zealand Building Code, G4, has been changed. This is supported by Acceptable Solution
G4/AS1 Fourth Edition that specifies mechanical ventilation in accommodation units that contain cooktops, showers and baths.
Residential Tenancy Regulations to the Healthy Homes Standards
Residential Tenancy Regulations for rental properties only is changing to the Healthy Homes Standards, sub part 4 - Ventilation Standards.
Complying with the Acceptable Solution G4/AS1
To comply, the mandatory mechanical extract system must deliver minimum airflow rates for the complete installed ventilation system. This means
that airflow rates must deliver the airflow after resistance of the ducting, internal and external grilles, as well as all other accessories, such as
backdraught shutters, are included.
Fan selection is important as some types are far better at overcoming ducting system pressure drops.
Additionally, the quality of the ducting system installation can be all important. Rigid duct systems (see page 102) are best as they are the most
efficient. Good installation practice is vital for flexible duct systems.
Room Airflow Rate (min.)
Intermittent Continuous
Toilet1) 25 l/s 10 l/s
Bathroom/shower 25 l/s 10 l/s
Laundry2) 40 l/s -
Kitchen 50 l/s 12 l/s
Duct Supports
Exterior Grille
Airflow
Airflow
Interior Grille
Sealant Cavity
Sleeve
Maximum length of
flexible ducting
Minimum radius =
diameter of ducting
Bathroom Kitchen
25 l/s Metres of Ducting 50 l/s Metres of Ducting
12345678910 12345678910
No. of
Bends
1
No. of
Bends
1
2 2
3 3
4 4
5 5
Fan Selection
Hyper150 EC Mixflo 150 Blue Jet
Preferred flexible
ducting route
Peaks and troughs
Restrictions

Installation Instructions Specifications are subject to change without notice Page 3
Inline Extraction Fan Kits - 150mm Contour
INLINE EXTRACTION FAN KIT INSTALLATION AND ELECTRICAL CONNECTION MUST
BE CARRIED OUT BY A REGISTERED ELECTRICIAN
BEFORE INSTALLING THE INLINE EXTRACTION FAN KIT, MAKE SURE YOU HAVE TURNED OFF THE MAIN
ELECTRICITY SUPPLY. DO NOT TURN IT BACK ON UNTIL THE INLINE EXTRACTION FAN KIT IS FULLY
INSTALLED AND READY TO USE.
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A REGISTERED ELECTRICIAN IN ACCORDANCE
WITH THE LATEST WIRING RULES AS/NZS3000.
CAUTION
• Before use, please check that the supply voltage and that of the appliance are the same (see product rating label).
• All wiring and wiring connections must comply with all current national wiring rules and regulations including AS/NZS3000:2017, or latest
edition thereof.
• Any changes or modifications made or attempted to this product, without the prior written approval of the manufacturer, will void any and all
stated warranties.
• When fitting through an external wall, and external grille must be fitted at all times.
• Fan kits should only be installed by fixed wiring. A flexible cord should not be used.
• This fan is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are capable of, and have been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
• Children should be supervised to ensure that they do not play with the fan.
• In case of damage to the supply cord, switch off the device and do not tamper with it. Damaged supply cords must only be repaired or
replaced exclusively by the manufacturer or by an appointed representative. Failure to comply with the above may endanger the safety of
people and cause possible damage to the whole system.
• The fan kit is to be installed so that the blades are more than 2.1m above the floor.
• Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances when
mounted in outside windows or walls.
WARNING
• This inline extraction fan kit is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials away
from the fan kit and keep them away from the sides and rear.
• Do not use near or in the immediate vicinity of a bath or swimming pool or any wet areas.
• To protect against electric shock, do not immerse cord or plug in water or any other liquids.
• Do not insert or allow foreign objects to enter any ventilation openings, as this may cause an electric shock, fire or damage to the fan kit.
• Do not put fingers or foreign objects into the grille while in operation.
• Any changes or modifications made or attempted to this product, without the prior written approval of the manufacturer, will void any and all
stated warranties.
• To prevent overheating of this fan kit, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and
outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER.
• Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
• This product contains recyclable materials. Do not dispose of this product as unsorted council waste. Please contact your local council for the
nearest collection point.

Installation Instructions Specifications are subject to change without notice Page 4
Inline Extraction Fan Kits - 150mm Contour
ELECTRICAL CONNECTIONS
BROWN
BLUE
LIVE
EARTH
NEUTRAL
GREEN/YELLOW
F
N
TIMER
FAN2444
LIVE
NEUTRAL
EARTH
LIGHT SWITCH
FLUSH BOX
(WALL MOUNTED)
BLUE
BROWN
GREEN/YELLOW
S
L
Diagram 1
Diagram 2

Installation Instructions Specifications are subject to change without notice Page 5
Inline Extraction Fan Kits - 150mm Contour
1. First select the fascia you prefer in your room. There are eight designs in the Contour fascia range with the selection from white, or black, round
and square fascias with, or without, an LED all suitable for fitting to the adapter plate supplied as part of this kit.
2. The interior grille comes in two parts, the adapter unit (supplied) and the fascia (sold seoarately). Cut a 238mm hole in the ceiling directly
over the shower head ensuring first that the area above is free from obstruction and between two joists.
3. Push the adapter unit section into the hole in the ceiling and use the attached fixing clips to secure the adapter unit to the ceiling. Complete by
fitting the fascia to the adapter plate by aligning the spring clips.
4. Select a suitable place for the fan to be screwed to a joist and secure using two screws through the fixing bracket. The fan motor is of ball
bearing design to prolong the life of the motor.
NOTE: The discharge end of the fan unit is the end where you can see the fan blade clearly. There is also an arrow on the unit
showing airflow direction.
5. For the exterior grille select a suitable position in either the soffit or on an outside wall for the fixed louvre grille. Carefully remove the grille
insert from its housing by levering gently at the sides with a small screwdriver. Cut a 160mm hole ensuring first that the area above is free from
obstruction.
6. Attach one end of the flexible duct to the spigot with the duct tape provided and, from the outside, feed the duct through the hole until the grille
is flush with the soffit/wall.
Mark the position of the fixing holes on the soffit/wall. Drill the holes and screw the grille to the soffit/wall then refit the chosen grille to the
chassis.
NOTE: It is best not to cut the flexible duct until the grille has been screwed to the outside surface to avoid the possibility of
cutting the duct too short.
7. Pull the flexible duct gently to the discharge spigot of the fan and cut it to length and connect to the fan with duct tape provided.
NOTE: The discharge end of the fan unit is the end where you can see the fan blade clearly. There is also an arrow on the unit
showing airflow direction.
8. Connect the remaining piece of duct to the ceiling grille and onto the fan using the duct tape provided.
NOTE: Make sure wherever possible to keep the duct running in a straight line as this will improve the performance of the fan.
9. Make the electrical connection as follows:
Wiring of Standard Switching model FAN7044 (Diagram 1).
The fan can be connected to the light switch so that the fan will start when the light is switched on, or a dedicated fan switch (not supplied).
The fan should not be accessible to a person using either the shower or the bath.
Wiring of Timer Switching model (timer sold separately) (Diagram 2).
The fan can be connected to the light switch so that the fan will start when the light is switched on, or a dedicated fan switch (not supplied).
The fan should not be accessible to a person using either the shower or the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm2in section in section. All wiring
must comply with current regulations. This system should be installed by a registered electrician.
The timer mechanism supplied is a fully adjustable timer which is installed in the flush box. This means that the fan will run on for approx
0-20 minutes depending on settings (see diagram 2 for wiring instructions, and also instructions included with FAN2444 timer).
NOTE: There is an adjustable 0-5 minute delay time setting for switching the fan on.
INSTALLATION

Installation Instructions Specifications are subject to change without notice Page 6
Inline Extraction Fan Kits - 150mm Contour
Flexible duct
Adapter plate and fascia
External grille
EC axial inline extraction fan
screwed to the joist
TYPICAL INSTALLATION
PUB01550 2001
Recommended
mounting position

Simx Warranty Information
In this warranty:
We means Simx;
You means the consumer of the Goods
Supplier means the authorised distributor or retailer that sold you the Goods in New Zealand or Australia; and
Goods means the Simx product accompanied by this warranty and purchased in New Zealand or Australia.
The benefits provided to you under the following warranty are in addition to any other rights and remedies available
to you under the law:
1. If, during the time from the date of purchase (Warranty Period), there is a defect in the Goods due to improper
workmanship or material, we will replace or repair the Goods without charge. Any replacement product is
warranted only for the time remaining on the original Warranty Period.
2. We are not obliged to replace or repair the Goods under clause 1 if the Goods have been improperly stored,
installed, connected, used, operated, repaired, damaged, abused, tampered with, altered (without our written
approval), or not maintained in accordance with our recommended installation, connection and operating
instructions.
3. We exclude liability for:
a) consequential loss or any other loss or damage caused to property or persons arising from any cause
whatsoever;
b) damage to consumable items such as lamps and starters; and
c) damage arising from normal wear and tear.
4. In order to claim under this warranty you must, within the Warranty Period, return the Goods to the Supplier,
together with the original proof of purchase including the details below:
Supplier Name _____________________________
Date of Purchase _____________________________
Model Number _____________________________
Invoice/Receipt No. _____________________________
5. This warranty does not cover the cost of claiming under the warranty or transporting the Goods to and from the
Supplier.
Our Goods come with guarantees that cannot be excluded under the New Zealand and Australian Consumer Law.
You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the Goods repaired or replaced if the Goods fail to be of
acceptable quality and the failure does not amount to a major failure.
To speak to someone about your Simx product or claiming under this warranty, please contact:
Simx Ltd New Zealand
p: +64 9 259 1660 f: +64 9 259 1661
www.simx.co.nz
Table of contents
Popular Air Handler manuals by other brands

AERA
AERA EVO-MODULAR user manual

Williams
Williams AH Installation, operating, & maintenance instructions

Amana
Amana M Series manual

York
York YBAH Series Installation, operation & maintenance manual

American Standard
American Standard TMM5A0B24M21SAA Installer's guide

INGENIA
INGENIA CAH Operation and maintenance