Siruba PS Series User manual

PATTERN MACHINE TOUCH PANEL
操作說明書
OPERATION MANUAL


ENGLISH
ENGLISH

For the sewing machine, automatic mechanic system, and auxiliary devices (hereinafter referred as “machine "), it
is inevitable to conduct work near moving parts of the machine. This means that there is always a potential risk from
the moving parts. Operators actually operating the machine and service technicians performing maintenance and
repair are strongly advised to read and understand fully the following instructions in advance.
The safety instructions include items which are not listed in the specifications of your product.
It is the manager/supervisor´s responsibility to have their fellow workers fully understand before operation.
Fail to follow the instructions listed in this manual may cause severe injury or even death, and damage to the
property.
Explanation of warning indications and labels.
GENERAL SAFETY INSTRUCTION
CAUTION HIGH VOLTAGE
Do not open the cover
of control box within 10
minutes after turn off
the power.
HIGH SPEED MOTION
POSITION
In case of industrial
accident
CAUTION HIGH SPEED
MOVING PARTS
PREVENT FROM WORK-
RELATED INJURIES
HIGH SPEED MOTION
POSITION
In case of industrial
accident
CAUTION
機械作動部份請注意裝上
保護裝置
穿線、換線、調整、清潔
時請注意關閉電源.
Moving parts may cause in jury.
Operate with safety devices.
Turn off main switch before
threading, changing bobbin and
needle, cleaning etc.
PICTORIAL WARNING INDICATION PICTORIAL WARNING INDICATION
There is a risk of injury if contacting a
moving section.
Be aware that holding the sewing
machine during operation can hurt your
hands.
There is a risk of electrical shock if
contacting a high-voltage section.
There is a risk of entanglement in the belt
resulting in injury.
There is a risk of a burn if contacting a
high-temperature section.
There is a risk of injury if you touch the
button carrier.
Be aware that eye de ciency can be
caused by looking directly at the laser
beam.
INDICATION LABEL
The correct direction is indicated.
There is a risk of contact between your
head and the sewing machine. Connection of a earth cable is indicated.

Danger
An accident means "to cause personal injury or death, or damage to property."
When it is necessary to perform service on electrical parts, be sure to turn the power off and wait for 5 minutes or more
before opening the power cabinet/box in order to avoid electrical shock.
Caution
1. Basic precaution
(1) Read the manual and other papers supplied with accessories of the machine before operation. Keep the manual
and papers at hand for quick reference.
(2) The content of this section includes items which are not listed in the specification of your product.
(3) Always wear safety goggles and gloves to avoid accident caused by parts breakage.
(4) For those who use a heart pacer, please consult the medical specialist first.
2. Safety devices and warning labels
(1) Check to ensure all safety devices are correctly installed in place and properly before operation.
(2) If any of the safety devices is removed for service cause, please be sure to replace it back to position and verify
that it works normally before resuming operation.
(3) Always keep the warning labels adhered on the machine clearly visible. If any of the labels is missing or
contaminated, replace with a new one at soon.
3. Application and modification
(1) It is prohibited to use the machine for any application other than its original intention, or in any manner other than
that prescribed in the instruction manual.
(2) Never modify or alter the machine. Any unauthorized change of the specification will not be covered by the
warranty.
(3) Our company assumes no responsibility/liability to damages, injuries, or death resulting from the machine which
has been modified or altered.
4. Education and training
(1) The plant managers/supervisors are obliged to provide education and training to operators and service
technicians. A good education/training plan not only avoids personal injury but also prevent damage to the
property.
(2) Only a well-trained operator is allowed to operate the machine.
(3) Only a certified technician is allowed to perform service to the machine.
5. Situations that you must turn off the power
Turning off the power: press EMG Stop (if there is one), switch off the power, and remove the power plug from the
outlet.
(1) When there is a failure or abnormality, press EMG Stop (if there is one), switch off the power.
(2) To prevent accident resulting from abrupt start of the machine, before operating the machine, always turn off the
power and switch on again.
(3) When cleaning or inspecting the machine, make sure the machine stops completely after turning off the power.
(4) When performing service (i.e. changing of adjusting any component), make sure the power is off and the
machine stops completely.
SAFETY PRECAUTIONS

6. Remove the power plug by holding the plug section instead of the cord to avoid electrical shock, leakage, or fire
accident.
7. Turn off the power whenever the machine is left unattended between works.
8. In case of a power failure or black out, turn off the power to avoid damage or accident.
9. Fail to obey instructions above may cause severe injury or death to the operators.
1. Transportation
(1) When you lift or move the machine, please take the machine weight into consideration and apply a safe manner.
Refer to the specification for the information you need for transportation.
(2) Apply sufficient safety measures when lifting or moving the machine to avoid falling or dropping.
(3) To avoid unexpected accident, do not reuse the packing material for transportation.
2. Unpacking
(1) Before proceeding to unpacking, check the balance of the machine and apply necessary tools to hold the proper
position.
(2) When unpacking, follow the instruction printed on the cartoon. Be careful of the nails and chips when unpacking
from a wooden rack.
3. Installation:
3A. Table and Stand
(1) Only adopt a qualified genuine table and stand to assure the holding support. In case you need to leave the
machine on a surface temporarily for service, make sure the surface is strong enough to hold the weight.
(2) If casters are applied to the table stand, adopt casters with a locking mechanism only and lock them well to
secure the machine during the operation and service.
3B. Cable and Wire
(1) The cables and wires must comply with the specification and requirement.
(2) The cables and wires shall be free from bending or extra force. Reserve a free space of at least 30mm between
cables/wires and the moving parts.
(3) Do not apply starburst connection when wiring.
(4) All connectors must be fixed securely. And always hold the connector body when removing it.
3C. Grounding
(1) Grounding is necessary and must be done by a certified technician.
(2) Check and ensure the grounding is secured before operation.
3D. Motor
(1) The motor must comply with the specification and requirement.
(2) If there is a belt in the motor transmission, adopt or apply a proper protector to avoid entangling.
4. Before Operation
(1) Before turning on the power, make sure all the connectors, cables, and wires are free from damage, dropout, or
looseness.
PRECAUTIONS TO BE TAKEN IN VARIOUS OPERATION STAGES

(2) Check and make sure the pulley rotation follows the same direction as labels.
(3) Make sure all the stand casters are locked or fixed in position.
(4) Keep the working area clean from obstacles.
5. During Operation
(1) Always keep your fingers, hair, or clothing away from the moving components and moving area. Do not place
your personal belongings on the machine.
(2) The machine is designed to run at high speed. Always keep your hands away from the moving area. Do not
resume the work cycle until the machine stops completely.
(3) Be careful not to be caught by the machine or components when removing or resetting the machine.
(4) To avoid accident caused by abrupt start, when performing service on the motor or belt, make sure the power is
off and the machine stops completely.
(5) A servo motor is silent as the machine stops. Be sure to turn off the power to avoid an abrupt start.
(6) Always keep the fan and airway of the power cabinet clean from any obstacle.
6. Lubrication
(1) Apply only qualified oil and grease onto the parts as instructed in the manual.
(2) If the lubricant contacts your eye or body, wash it off immediately. Consult a medical care if necessary.
(3) If the lubricant goes into your body accidentally, go to the nearby medical care immediately.
7. Service
(1) Only a certified engineer/technician is allowed to perform service to the machine, including adjusting and
repairing. Use only genuine parts for replacement. Our company assumes no responsibility/liability for any
accident caused by improper repair or adjustment, or the use of any parts other than genuine one.
(2) Only a certified technician or authorized engineer is allowed to repair or maintenance the electric system.
(3) When performing service to air-driven parts, like an air cylinder, first disconnect the air supply and expel the air
completely to avoid abrupt start.
(4) Check all screws and nut are fixed well after adjusting and replacement.
(5) A periodical cleaning is necessary. Make sure the power is off and the machine stops completely before cleaning.
(6) If the machine functions poorly or abnormally, stop the operation and turn off the power. Contact the authorized
dealers or us to request for a technical service support.
(7) When there is a fuse failure, turn off the power, find out the cause of the failure and apply solution to it, then
replace with a new one with the same spec.
(8) Periodically check and clean the fan airway and the cable/wiring.
8. Working Environment
(1) The machine should be free from the affection of electro-magnetic wave.
(2) The power supply should be in good and reliable condition, the fluctuation of rated voltage should be less than
10%.
(3) Always check the air pressure and quality. Some extra device might be needed if the supply is not reliable.
(4) The machine is designed to be used with ambient temperature 5°C ~ 35°C, relative humidity 35%~85%.
(5) To protect the electronic components and for safety cause, when there is a frost resulting from a dramatic
temperature rise, disconnect the power and wait until it dry completely.
(6) For safety cause, when there is a thundering or lightening, stop the operation and disconnect the power supply.
(7) Do not use TV or radio nearby the machine as to avoid interference.
(8) Apply necessary protection during operation. Follow applicable regulations set by local administration.
(9) For disposal of packages, lubricant, and product, please follow the applicable regulations set by local
administration.

CONTENT PAGE
SUMMARY DESCRIPTION 1
INSTRUCTION 5
QUICK (P) PATTERN OPERATION 22
COMBINATION © PATTERN OPERATION 25
PATTERN EDITING 30
INFORMATION FUNCTION 39
COMMUNICATION FUNCTION 40
MODE AND PARAMETER SETTING 45
APPENDIX 1 ERROR TABLE 57

SUMMARY DESCRIPTION
Overview
This series of industrial sewing machine computer control system, the spindle motor is driven by the world's advanced
level of AC servo control technology, featuring large torque, high efficiency, stable speed and low noise. Diversified
operation panel design can meet the requirements of different customers. The system adopts German structure
design, which is convenient and quick to install and maintain. The system control software can be upgraded through
remote communication, which is convenient for users to continuously improve product performance.
Model
Project Flat seam stitch sewing machine (with large hook)
1 Stitch Type Single Needle Lockstitch
2 Maximum Sewing Speed 2,700rpm
3 Sewing Size(X×Y)GSM-1310G maximum: 130×100mm;
GSM-2210G maximum: 220×100mm
4 Feeding Type Intermittent Feed (Stepping Motor)
5 Needle Gauge 0.05-12.7mm
6 Total Stitch Memory 500,000 stitch (※)
7 Maximum Stitch 20,000 stitches (1 program)
8 Storage of pattern data in the memory Memory: 999 (※). USB: No Limit
9 Type of Pressor Foot Electromagnetic specifications: Steppting Motor,
Pneumatic specifications: Pneumatic Type
10 Lift length of clamp Electromagnetic specifications: up to 25mm, Pneumatic
specifications: up to 30mm
11 Two Step Pressor Foot
Electromagnetic specifications: left and right integrated presser foot.
Pneumatic specifications: left and right split presser foot
12 Intermittent presser foot lift length 22mm
13 Intermittent presser stroke size 2-4.5mm、4.5-10mm 或0(3 mm at the factory)
14 Hook Type Half turn 2x hook (standard hook optional)
15 Thread Fastening Device Standard
16 Thread Trimmer Device Standard
17 Data Storage Type Memory (flash memory), CF card (32, 64, 128, 256MB)
[Optional] 3.5 Disk 2HD/1.44MB.2DD
18 Number of User Program 50
19 Number of Loops 9
20 Motor AC Servo Motor 550W
21 Total Weight
Machine Head: approximately 88kg, Operating Panel: approximately
0.6kg Control Box: 14.2-16.2kg (Depend on Voltage)
22 Voltage Single phase 100V/220V, 3-phase 200V/220V/380V/400V 400VA
23 Air Consumption 0.5Mpa 1.81/min
Technical Data Sheet
Maximum sewing speed should be reduced according to the sewing conditions.
P1

Safety Precautions
1.Operating environment
Do not use this control unit in the following environments:
(1)Power supply voltage
Voltage fluctuation will exceed ±10% of the rated
voltage.
Ppower supply capacity cannot be guaranteed in a
location with a specified capacity.
(2)Radio interference
Nearby location with radio wave transmitters, high-
frequency machines generate strong electric and
magnetic fields.
(3)Temperature and Humidity
Room temperature is between 0 °C to 50 °C.
Outdoor or direct sunlight.
Location next to heater
Relative humidity is between 5% and 95% (non-
condensing).
(4)Air
Corrosive or dusty location.
Place where air or oil explosion are likely to occur.
(5)Vibrate
Place where vibration most likely to occur. Control Box
should be place somewhere else without any vibration.
2.Assemble
(1)Control Box
Please follow instruction and install correctly.
(2)Attachment
To install other accessories, turn off the power and
unplug the power cord.
(3)Power Cord
Do not use force to pinch the power cord or
excessively twist the power cord.
Please do not leave the power cord near the rotating
parts, at least 25mm or more.
Before the control box connects to power supply,
please check whether the power supply voltage is
same as voltage indicate on the control box and
exact position. If a power transformer is used, the
same power supply must be checked before it can be
supplied. At this moment, power switch on the sewing
machine should be at [OFF] position.
(4)Ground Wire
In order to prevent electric shock and electric leakage
result electric shock. Grounding wire on the power line
must be grounded.
(5)Accessories
If you need to use electrical accessories, please follow
the instructions.
(6)Disassemble
Before remove control box, please turn of the power
and unplug all power plugs.
While unplug power plug, pelase do not pull the wire.
Please pull the power plug by hands.
High voltage inside control box. Switch off power and
wait for 5 minutes before open control box cover.
3.Maintenance, Inspection and Repair
Repair and maintenance task should be performed by
trained technicians.
When replacing the needle and the bobbing, be sure to
turn off the power.
Please use original parts from supplier
4.Other Safety Issue
Please do not touch any rotate and moving parts while
sewing machine is running. (especially needle and belt
accessories). Hair should not go near the machine to
avoid any unexpected issue.
The control device must not fall to the ground, and it is
not allowed to insert other items into the gap.
Please do not operate with the covers removed.
If the control device is damaged or cannot be operate.
Please have it checked by an experienced technician or
send to repair center. Please do not operate the machine
until defects eliminated.
Please do not modify or change the control unit by
yourself.
5.Disposal
Please dispose with general industrial waste.
6.Warning signs and danger signs
Wrongful behavior may result dangerour.
Please check below description
Please follow the instructions to work.
Pay attention to the danger of high
voltage.
Pay attention to high temperatures.
Be sure to connect the ground wire.
Never do it.
Caveat: Wrong actions can result in serious
injury or death.
Note:
Wrong actions can result in injury or
damage to the house or property.
Symbol with description as below
P2

Warning! Use of Precautions
Noise
interference
Power supply
Green
(green/yellow)
High voltage danger
P3
1. Foot must leave the pedal before pressing [ON] 2. Power must turn off when operator left
workstation.
3. If you want to cross the head or change the
needle or thread, be sure to turn off the power.
4. The grounding wire should be grounded.
5. Do not use multi-jack extension cords for home
use.
6. High voltage inside control box. Switch off
power and wait for 5 minutes before open control
box cover.
7. After replacing the motor, be sure to set the spindle motor mounting angle as shown in this document.
8. Keep away from machines that generate high-
frequency interference.
9. If the external signal socket is used to connect the
application accessory, the length of the cable should be
as short as possible. Long cable may cause malfunction.
Use the isolation cable for the connection cable.
10. If the fuse is blown, please replace the issue and then replace the fuse with same capacity.

Operation Method
screen operation panel system
adopts the industry's advanced
touch operation technology. It
comes with friendly interface and
convenient operation. Innovative
changes to the daily use of the
user. The user can use the finger
or other object to touch the screen
to complete the corresponding
operation. Users should avoid
touching the screen with sharp
objects during operation to avoid
permanent damage to the touch
screen.
Funciton keys include a preparation
key, an information key, a mode
key, and a communication key.
Refer to the descriptions in the
following sections for specific
operation methods.
Standardization
Function buttons adopt industry-
recognized graphic logo. Graphics
are international languages that
can be recognized by worldwide
users.
Warning! Users should take care to avoid touching the screen with sharp objects during use to
avoid permanent damage to the touch screen.
P4

INSTRUCTION
Universal Button
The buttons for common operations on each interface of the system are as follows:
No. 圖示 功能
1 Confirmation key →Input interface enters the sewing interface / sewing interface to
exit to the input interface
2 Information button →View version information and threading diagram
3 Communication key →USB disk communicates with the panel to perform mutual
copying of patterns or parameters
4 Setting button →Enter function interface
5 Pattern selection button →Open pattern file
6 Registration button →Register pattern number
7 Name key →enter the name of the pattern
8 Electric pressure frame lifting button →Motor type lift frame, pneumatic invalid
9 Medium presser foot height →Set height of intermediate presser foot
10 Adjustment button →Adjust the seam point
11 Threading key →Threading
12 Cancel button →cancel current set value / exit current interface
13 Confirmation key →Save current setting value
14 Trial sewing button →Enter single step seam interface
15 Winding button →enter winding mode
P5

Basic Operatoin
①Turn On Power Switch
After the power is turned on, the data login
interface is displayed.
②Select the pattern no.
The selected pattern No. will be displayed under
the current interface. Press the pattern selection
button and enter the sub-menu to select
the pattern No.
For details on the operation of pattern selection,
see [2.8 Pattern Selection].
③Prepare Mode for sewing
After pressing the READY key , the button is
darkened to indicate that the pattern
confirmation interface has been entered. At this
moment sewing can be performed.
④Start Sewing
Place the sewing item on the presser foot, step on
the pedal to lower the presser foot, start the sewing
machine, and start sewing.
P6

Ordinary Pattern Operation
(1)Sewing data registration interface
The data login interface as shown on right. For
detailed function description, please refer to the
function key description table.
Function Description:
No. Function
A Pattern Name Display Area
B Tension Button
C Pattern Graphic Display Area
D Speed Button
E X Zoom Rate Button
F Y Zoom Rate Button
G Adjust the sewing point button
H Threading Button
I Pattern Information Display Area
J P Pattern Shortcut Button Area
K P Pattern Register Button
L P Pattern Page up Button
M P Pattern Page Down Button
N Pattern Selection Button
O Pattern Registration Button
P Pattern Naming Button
QElectric Presser Foot Lift Button
R Medium Presser Foot Height Button
S Counter Mode Button
T Counting Value Button
P7

(2)Sewing Interface
Press Ente to sewing interface as shown on
the right. For detailed function descriptions, please
refer to the function key description table.
NO. Function
A X Zoom Rate Display
B Y Zoom Rate Display
C Inoperable Button
D P pattern area is not operational
E Trial Sewing Button
F Winding Button
--- Other buttons with the input interface function
P8

Pattern Registration
Up to 999 ordinary patterns can be registered.
Press to enter the pattern registration interface
(as shown on the right):
①Enter pattern number
Select desire pattern number by using the
digit keys. The pattern number range must be
201~999. If you enter another number range will
be displayed.
②Register New Pattern
After confirm the pattern number and pressing
, previously displayed pattern data will be
copied to the new registration pattern. And after
the operation is completed, return to the new
registration pattern data login interface.
If the entered number is already registered, it will
overwrite existing pattern.
Press the button to exit the registration
interface.
P9

Pattern Naming
Press to enter the pattern naming interface (as
shown on the right)
A Delete Delete input characters
one by one
B Shift Right Shift Right
C Shift Left Shift Left
D Empty Clear all charac ters
currently entered
Select the character you want to enter and
press to end the pattern naming operation.
Position of the character can be determined by
moving the cursor, and the delete key can eliminate
the position character.
P10

Winding
①Install Bobbin
Insert the bobbin as shown on the right.
②Display bottom line winding interface
After the winding button is pressed , the
winding interface displayed (as shown on the
right)
③Start Winding
After stepping left pedal and presser foot drop,
step on the start pedal to start winding.
④Stop Sewing Machine
After the winding is started, step on starting pedal
to stop rotating. Once winding stopped, step on
the left pedal to lift the presser foot back to sewing
mode.
P11

Threading
①Enter Threading Mode
Press the key on the input interface or the
sewing interface to enter the threading state. The
threading button turns red . The screen
changes as shown in the figure. In this state, the
machine cannot perform other operations.
②Exit Threading Mode
After threading, press the key again return
back to input interface or sewing interface.
P12
Table of contents
Popular Touch Panel manuals by other brands

PQ Labs
PQ Labs MTSIR321 Series user manual

Winmate
Winmate R15IB3S-SPC369 user manual

Xilica Audio Design
Xilica Audio Design XTouch Series: XTouch50 Quick install guide

InFocus
InFocus JTouch 00 Series Hardware guide

JETWAY
JETWAY HPC-156 user manual

Avalue Technology
Avalue Technology MPC-21W3 Quick reference guide