OPTO-EDU A59.3521 User manual

A59.3521 10.5" Touch Screen Android Pad Digital Camera, 8.0M
Spec.
Model
A59.3521
Category
HD All-in-One Android 11 System Tablet Digital Camera
Sensor
1/1.8” CMOS Sensor
Effective Pixel
8M, 4K
Screen
10.5” High-Definition Touch Screen
Operation System
Android 11
WIFI
2.4GHz/5GHz Dual-band WIFI, Support WIFI6
Bluetooth
Bluetooth 5.0
Output
USB3.0*2, USB2.0*1, HDMI, Gigabit LAN Port
Pixel size
2.0um*2.0um
Power
DC-12V/2A
Function
Basic Function
Android Interaction, Installed S-Eye2.0 Measure Software
Image Adjustment
Brightness, Contrast, Saturation, Color Temperature
Camera Function
Mirror, Flip, Freeze, Black and White
UI Interface
Support User-friendly Mouse & Keyboard, And Touch Screen Operation
Photo
8.0M Image Capture
Video
1080P Video
Storage
Still Photo And Video Recording, Picture Preview
Marking
Point Coordinates, Crosshairs, Coordinate System, Text Annotations
Length
Measurement
Straight Line, Folded Line, Curve Length, Parallel Line Distance, Point Line
Distance
Geometric
Measurement
Line Segment Length, Radius Fixed Circle, 2 Point Fixed Circle, 3 Point Fixed
Circle, Concentric Circle, Radius Fixed Circle
Geometric Area
Measurement
Polygon, Rectangle
Measurement
System
Built-in S-Eye Software
Package
Box Size
237*169*10.5mm
Weight
0.6kg
Accessory
DC-12V/2A Power Adapter
Features
⚫10.5" Touch Screen Android Pad + 4K Digital Camera, All-in-One
⚫8.0M 1/1.8" CMOS Digital Camera Resolution 3840*2158@30FPS
⚫Android 11 Tablet Built-in Memory RAM 2G + ROM 16G For Photo & Video Record
⚫USB3.0+HDMI+LAN Output, Touch Screen + USB Mouse & Keyboard Control
⚫Open & See Microscope Image Directly, Built-in Software For Measure & Analysis
Specification

Operation
1. First, connect the tablet to DC-12V power adapter
2. Then connect the tablet to microscope by standard C-Mount.
(See how to connect digital camera to microscope at end of this manual.)
3. After connecting the power, long press the Power On button, the blue light stays on
4. After power on, the system directly starts into the microscope image preview interface
5. The tablet can be connected to other large monitor screen through HDMI port, to show
sync real time image of microscope camera.
6. The tablet has Android 11 system & measure software installed, no need to install any
other software.
Under measure mode, click button to capture screenshot and save measure result.
7. The tablet has touch screen, can take photo, record video, measure image, or adjust all
parameters directly by touch.
8. The USB mouse & keyboard can be connected to USB 2.0 port to control tablet directly
9. There is 16G memory built-in to store photos and videos taken by digital camera.
10. The USB disk can be connected to USB 3.0 port to copy the photos and videos recorded.
Under main interface, click button to explore, copy, paste files to USB disk.
11. The tablet can be connected to PC through USB 3.0 port or LAN port to copy files.
Power On
USB 2.0*1
HDMI
USB 3.0*2
LAN
DC-12V
C-Mount

S-Eye Software Introduction
Main Interface
The camera & tablet will enter the main interface directly after power on, and you can click the
shortcut buttons on the bottom of screen to set, take photo, record video, review, measure, zoom
in/out, mirror image, flip image, etc. as needed.
Setting, Photo Capture, Video Record, Preview, Measurement.
Digital Zoom In/Out (1x~16x), Mirror Image, Flip Image
Black/White Mode, Image Freeze, Scale Switch, Parameter Reset, Color & Size Adjust
Click arrow to show more settings:
Sound, Brightness, IE Brower, Explorer (USB Disk), Lan, WIFI, Time Set

Setting Mode
1, After the camera is turned on directly into the screen as shown
2, Click button to pop up the setting menu as above picture
3, Set the image parameters according to demand
(1) Auto Exposure: Manual Setting and Auto Setting (Default).
(2) White Balance: Automatic (Default) and One-touch Set.
Under the standard color temperature, click one-touch button when lens is facing standard light
or white paper, the camera will automatically load parameters according to the current condition,
to achieve the correct white balance.
(3) Anti-Flicker: The system provides 50HZ and 60HZ optional.
(4) Exposure: Adjust the exposure time of the camera as needed
(5) Contrast: Adjust the image contrast as needed
(6) Saturation: Adjust the image saturation as needed
(7) Brightness: Adjust the image brightness as needed
(8) Sharpness: Adjust the image sharpness as needed
(9) Color Temperature: adjust the image color temperature as needed

Calibration Setting
Click to choose the button to enter measure calibration mode.
1. mode: providing calibration mode, line calibration and circle calibration are available to be
selected. After clicking the line calibration icon, the preview interface will directly display the
line segment, according to the location and length of the calibration scale, the mouse will move
the line segment to the top of the calibration scale to overlap with the corresponding scale.
Please set the name, unit, accuracy, and finally click the save icon to complete the calibration
2. Click to delete unwanted calibration information after clicking the delete icon
3. Name: after drawing the line segment cursor, directly defaults in this position. Enter the
corresponding name and then select the unit after confirming, the cursor jump to the next
window
4. Accuracy: After setting the name and unit, you need to set the corresponding number of
decimals to ensure the measurement accuracy
5. Scale: provides the option to turn the scale on or off

Measure Mode
Click to enter measure mode, you can measure the objects, capture screenshot for report.
Point coordinates, straight line, dashes (end of right mouse button), drawing circle etc.
2 Points Circle, 3 Points Circle, Concentric Circles, Circle Center Distance.
Polygon, Rectangle, Angle, Point-Line Distance, Text Mark
Set Graph Color & Thickness, Delete One, Delete All, Save Screenshot, Export Measure Result
Table of contents