Occupancy Indicator Light Installation
Cutout template (shown to scale)
Ø .375" (10 mm)
2.375"
(60 mm)
3.5625"
(91 mm)
1. Tools required: Wire strippers, drill, tape
measure, screwdriver, and drywall saw.
2. Wireless receiver and indicator light
location: Locate switch inside restroom.
Measure height to top of outlet box.
3. On opposite side of wall (outside of restroom),
measure 3" (76 mm) above height of switch
and make cutout for indicator light as shown
in "Cutout Template" shown below.
HH+3"
(76 mm)
Inside restroom Outside restroom
4. Receiver mounting: Wireless receiver
mounts to electrical box using threaded
connector as shown.
External sensor in
12V DC out
0-10V- (Gray)
0-10V+ (Purple)
Relay load (Red)
Hot, 120-277 VAC (Black)
Neutral (White)
Orange, Gray,
and Purple wires:
Connect to indicator
light connector
Yellow wire
capped, not used
Red wire capped,
not used
5. AC voltage wiring: Connect line voltage to
BLACK wire and neutral to WHITE wire. RED
and YELLOW wires are not used.
Touchless Occupancy Indicator System
Installation Guide for 601146, 601147, 601148, and 601153
PAGE 1 OF 3
6. Indicator light installation: Feed cable of
indicator light through cutout and into switch
outlet box. Secure cable using included
strain relief connector. Ensure drywall
anchors are retracted far enough that wings
will be able to pop open by turning screws
counter-clockwise until anchor is at end of
bolt. Insert light into cutout and turn bolts
clockwise until anchors are securely held
against back of drywall. Connect indicator
light to wireless receiver via connectors.
1. Mount sensor in main area of restroom that will
experience most trafc. Sensor should be mounted
6 - 8 ft (1.8 - 2.4 m) from ground.
2. Remove mounting plate from sensor by pressing release
tab located on top of sensor. Hold mounting plate against
wall and mark two (2) mounting points. Drill two holes
with a 0.1875" (4.8 mm) bit and insert wall anchors.
Insert rst screw loosely and level mounting plate.
Insert second screw and hand-tighten both screws.
3. System operation and setup: System has been
programmed and sensors have been linked to the
corresponding receivers. No setup is required. When
sensor detects motion, indicator light will be illuminated
RED. If no motion is detected for 45 seconds, light will
change to GREEN.
Wireless sensor Installation – Wall mount
1. Remove mounting plate from sensor. Hold mounting plate
in place on ceiling and use a pencil to lightly mark two (2)
small dots for screw drill points. Drill two (2) holes with a
0.1875" (4.8 mm) drill bit and insert wall anchors. Insert
rst screw loosely and level mounting plate. Insert second
screw and hand-tighten both screws.
2. Remove ceiling tile from desired installation location.
Place mounting plate squarely on ceiling tile and insert
wire bracket through two (2) holes in mounting plate.
Feed wires through holes in ceiling tile. On front of ceiling
tile, atten wire bracket so it is snug against mounting
plate. On back of ceiling tile, twist wires together to hold
mounting plate securely.
3. Attach sensor to mounting plate, sliding sensor onto
mounting plate until it snaps into place.
Wireless sensor Installation – Ceiling mount
Touchless Occupancy Indicator System
Installation Guide for 601146, 601147, 601148, and 601153
PAGE 2 OF 3
SloanLED Headquarters
5725 Olivas Park Drive, Ventura, CA, USA
888.747.4LED (888.747.4533) • info@SloanLED.com
SloanLED.com
SloanLED Europe b.v.
Argonstraat 110, 2718 SN Zoetermeer, NL
+31 88 12 44 900 • europe@SloanLED.com
P/N 400403 Rev B 2020-10-21
Customer service and technical support
1. Set receiver into "Learn" mode by pressing LRN button
for one (1) second. LRN LED begins toggling RED/
GREEN indicating linking/unlinking mode is active.
2. Press "Menu" button on sensor once. LRN LED on receiver will display solid GREEN for four (4) seconds
and indicator light will remain RED for four (4) seconds. Once indicator light begins to ash RED/GREEN
again, wait 30 seconds or press LRN button for one (1) second to exit linking mode.
Multi-sensor Installations
LRN
button
Menu
button
601147 601153
Menu
button
Set
button
Set
button
Touchless Occupancy Indicator System
Installation Guide for 601146, 601147, 601148, and 601153
PAGE 3 OF 3

This manual suits for next models

3

Popular Measuring Instrument manuals by other brands

COLOGICX PROTOGEN EGCP-03 user manual

COLOGICX

COLOGICX PROTOGEN EGCP-03 user manual

Hach HQ11d Basic user manual

Hach

Hach HQ11d Basic user manual

TANEL Electronics WIP-22D user manual

TANEL Electronics

TANEL Electronics WIP-22D user manual

biochrom Novaspec III Plus manual

biochrom

biochrom Novaspec III Plus manual

Hach Hach SL1000 Basic user manual

Hach

Hach Hach SL1000 Basic user manual

KERN MSF 200 operating instructions

KERN

KERN MSF 200 operating instructions

Chauvin Arnoux DECADES BOXES user manual

Chauvin Arnoux

Chauvin Arnoux DECADES BOXES user manual

Ninglu AM706 Operation & installation manual

Ninglu

Ninglu AM706 Operation & installation manual

Milwaukee MI805 user manual

Milwaukee

Milwaukee MI805 user manual

Water I.D. PoolLAB 1.0 user manual

Water I.D.

Water I.D. PoolLAB 1.0 user manual

ADVANTEST R3267 series Operation manual

ADVANTEST

ADVANTEST R3267 series Operation manual

ENDA EPA242 manual

ENDA

ENDA EPA242 manual

Extech Instruments 461920 user guide

Extech Instruments

Extech Instruments 461920 user guide

Test Equipment Depot XFTP SAT LITE Operation manual

Test Equipment Depot

Test Equipment Depot XFTP SAT LITE Operation manual

Nidec ST-1100 Operation manual

Nidec

Nidec ST-1100 Operation manual

AT AT-LA500 user manual

AT

AT AT-LA500 user manual

Shihlin electric SPM-3 user guide

Shihlin electric

Shihlin electric SPM-3 user guide

sewerin Multitec 560 operating instructions

sewerin

sewerin Multitec 560 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.