Smarteh LPC-2.C05 User manual

USER MANUAL
Longo programmable controller
LPC-2.C05
GSM module
Version 5
SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +3 6(0) 3 44 00 / e-mail: in[email protected] / www.smarteh.si

Longo programmable controller LPC-2.C05
Written by SMAR EH d.o.o.
Copyright © 2012, SMAR EH d.o.o.
User Manual
Document Version: 005
July 1, 2012
i

Longo programmable controller LPC-2.C05
S ANDARDS AND PROVISIONS: Standards, recommendations, regulations
and provisions of the country in which the devices will operate, must
be considered while planning and setting up electrical devices. Work
on 100 .. 240 V AC network is allowed for authorized personnel only.
DANGER WARNINGS: Devices or modules must be protected from
moisture, dirt and damage during transport, storing and operation.
WARRAN Y CONDI IONS: For all modules LONGO LPC-2 – if no
modifications are performed upon and are correctly connected by
authorized personnel – in consideration of maximum allowed
connecting power, warranty of 24 months is valid from the date of sale
to the end buyer, but not more than 36 months after delivery from
Smarteh. In case of claims within warranty time, which are based on
material malfunctions the producer offers free replacement. he
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not include damage due to transport or because of unconsidered
corresponding regulations of the country, where the module is
installed.
his device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous voltage in the device can cause electric shock and may
result in personal injury or death.
NEVER SERVICE HIS PRODUC YOURSELF!
his device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).
If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.
Waste electrical and electronic equipment (WEEE) must be collected
separately!
LONGO LPC-2 complies to the following standards:
•EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-
3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013
•LVD: IEC 61010-1:2010 (3rd Ed.), IEC 61010-2-201:2013 (1st Ed.)
Smarteh d.o.o. operates a policy of continuous development.
herefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.
MANUFAC URER:
SMAR EH d.o.o.
Poljubinj 114
5220 olmin
Slovenia
ii

Longo programmable controller LPC-2.C05
Longo programmable controller LPC-2.C05
1 DESCRIP ION...................................................................................1
2 FEA URES.......................................................................................2
3 INS ALLA ION..................................................................................3
3.1 Connection scheme....................................................................3
3.2 Mounting instructions.................................................................5
3.3 Module labeling........................................................................7
4 ECHNICAL SPECIFICA IONS..................................................................8
APPENDIX A: PROGRAMMERS GUIDE...........................................................9
5 CHANGES .....................................................................................11
6 NO ES..........................................................................................12
iii

Longo programmable controller LPC-2.C05
DESCRIPTION
LPC-2.C05 module is used for communication with mobile GSM equipment, like GSM phone or GSM
modem. he communication between LPC-2 system and mobile equipment is established through
SMS messages.
Up to eight digital and eight analog values could be represented from LPC-2 system as well as up to
eight digital and eight analog commands could be sent from GSM phone or other mobile equipment.
his commands could act direct to digital and analog outputs or can be used for parameter settings.
LPC-2 system can works also in alarming mode, where SMS alarm message is sent in case of
abnormal situation (temperature too high, water leakage, etc.). he SMS alarm messages are sent
recurrently every hour on first three phone numbers stored on the SIM card. If the phone numbers
are stored in the international notation (with country code) then the prefix must start with “00”
and not with “+” symbol (e.g. Slovenian international code is 00386).
When LPC-2.C05 module is correctly installed and it is ready to operate. In this case status LED1
must blink (refer to the able 6). he starting sequence is executed once after reset. Complete time
base is 40 sec (see below).
a) b) c)
a) LED1 blinks once after reset and then is off – SIM card not inserted or SIM card PIN still enabled
b) LED1 blinks once after reset and then is on – GSM network problem; check antenna and GSM signal
level with the mobile phone
c) LED1 blinks once after reset and then start blinking – normal starting sequence; everything OK
IMPORTANT: The PIN number of the SIM card must be disabled otherwise LPC-2.C05 will not be
connected to the GSM network!
Module is powered from internal BUS.
NO E: For proper system configuration and data allocation please refer to LPC Composer software
help menu.
1

Longo programmable controller LPC-2.C05
2 FEATURES
Figure 1: LPC-2.C05 communication
module.
Table : Technical data
Dual band 900/1800 MHz
Optional RS-232 communication port, 9600 bps, 8 bits, one stop bit, no parity, no flow control,
reserved for external A command
Standard DIN EN50022-35 rail mounting
2

Longo programmable controller LPC-2.C05
3 INSTALLATION
3. Connection scheme
Figure 2: Connection scheme
Table 2: ANT.
AN . Antenna connector SMA/F (GSM antenna SMA/M)
Table 3: SIM CARD
SIM CARD SIM card connector
Table 4: K
Internal BUS Data & DC power supply Connection to I/O module
Table 5: K2
Internal BUS Data & DC power supply Connection to I/O module
3

Longo programmable controller LPC-2.C05
Table 6: LEDs
SIM Green LED: indicates C05 SIM
state
OFF: power off
Blink once: SIM card not inserted
or PIN enabled
ON: SIM status OK
NE Green LED: indicates C05 Network
state
OFF: power off
Blink once & ON: Low GSM signal
ON: SIM status OK
Status Green LED: indicates C05 state
OFF: power off
Blinking: In SMS RX/ X operation
ON: Normal starting sequence
4

Longo programmable controller LPC-2.C05
3.2 Mounting instructions
Figure 3: Housing dimensions
Dimensions in milimeters.
All connections, module attachments and assembling must be done
while module is not connected to the main power supply.
Mounting instructions:
1. Switch OFF main power supply.
2. Mount LPC-2.C05 module to the provided place inside an electrical panel (DIN EN50022-35
rail mounting).
3. Screw antenna (delivered together with LPC-2.C05 module) to the antenna connector.
4. Mount other LPC-2 modules (if required). Mount each module to the DIN rail first, then
attach modules together through K1 and K2 connectors.
5. Switch ON main power supply.
Dismount in reverse order. For mounting/dismounting modules to/from DIN rail a free space of at
least one module must be left on the DIN rail.
NO E: LPC-2 main module should be powered separately from other electrical appliance connected
to LPC-2 system. Signal wires must be installed separately from power and high voltage wires in
accordance with general industry electrical installation standard.
5
53
90
95
36
60

Longo programmable controller LPC-2.C05
3.3 Module labeling
Figure 5: Labels on housing
Label 1 (MC3 sample): Label 2 (MC3 sample):
Label 1 description:
1. LPC-2.MC3 is the full product name.
2. P/N:225MC304000 00 is the part number.
•225 – general code for product family,
•MC3 – short product name,
•0400 – sequence code,
•04 – year of code opening,
•001 – derivation code,
•00 – version code (reserved for future HW and/or SW firmware upgrades).
3. D/C: 6/05 is the date code.
•6 – week and
•05 – year of production.
Label 2 description:
1. S/N:MC3-S9-0500000 90 is the serial number.
•MC3 – short product name,
•S9 – user code (test procedure, e.g. Smarteh person xxx),
•0500000 90 – year and current stack code,
•05 – year (last two cyphers),
•00000190 – current stack number; previous module would have the stack number
00000189 and the next one 00000191.
6

Longo programmable controller LPC-2.C05
4 TECHNICAL SPECIFICATIONS
Table 7: Technical specifications
Power supply from internal BUS
Power consumption 1 W
Communication
Optional RS-232 communication port, 9600 bps, 8
bits, one stop bit, no parity, no flow control,
reserved for external A commands
Antenna connector SMA/M
Antenna impedance 50 Ω
Phone book capacity 100
SMS storage capacity 40 in ME (mobile equipment)
up to 25 in SIM (SIM dependent)
Frequency range GSM 900 and GSM 1800
Dimensions (L x W x H) 90 x 53 x 60 mm
Weight 120 g
Ambient temperature 0 to 50 °C
Ambient humidity max. 95 %, no condensation
ransport and storage temperature -20 to 60 °C
Pollution degree 2
Protection class IP 30
7

Longo programmable controller LPC-2.C05
APPENDIX A: PROGRAMMERS GUIDE
Memory allocation
ables below shows the example of memory allocation for C05 on position #1.
Boolean variables Rx:
I/O Module FBOOL8
I/O Name BI 0 BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 BI 7
Range 0 .. 1
Address MC3: 0x1069 + (N * 0x0040)
MC7: 0x0702 + (N * 0x0040)
Boolean variables x used to select the number of analogue (BI 0-BI 3) and digital (BI 4-BI 7) input
signals:
I/O Module FBOOL8
I/O Name BI 0 BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 BI 7
Range 0 .. 1
Address MC3: 0x1438 + (N * 0x0040)
MC7: 0x0101 + (N * 0x0040)
Boolean variables x:
I/O Module FBOOL8
I/O Name BI 0 BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 BI 7
Range 0 .. 1
Address MC3: 0x1439 + (N * 0x0040)
MC7: 0x0102 + (N * 0x0040)
8

Longo programmable controller LPC-2.C05
Word variables Rx:
I/O Module FWORD16
I/O Name WORD1 WORD2 WORD3 WORD4 WORD5 WORD6 WORD7 WORD8
Range 0 .. 65535
Address MC3: 0x160a + (N * 0x0040)
MC7: 0x0703 + (N * 0x0040)
Word variables x:
I/O Module FWORD16
I/O Name WORD1 WORD2 WORD3 WORD4 WORD5 WORD6 WORD7 WORD8
Range 0 .. 65535
Address MC3: 0x143a + (N * 0x0040)
MC7: 0x0103 + (N * 0x0040)
Boolean variable x used for alarming of the LPC-2 system(s):
I/O Module FBOOL8
I/O Name BI 0 BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 BI 7
Range 0 .. 1
Address MC3: 0x144e + (N * 0x0040)
MC7: 0x0117 + (N * 0x0040)
N = module position number;
N of Main module is 0 and counts up by 1 with every next module
9

Longo programmable controller LPC-2.C05
5 CHANGES
he following table describes all the changes to the document.
Date V. Description
1.7.2012 005 CGP General update , New HW and FW version
11.5.2010 004 Updated warranty permanence.
30.6.2005 003 he initial version, issued as LPC-2.C05 module UserManual.
10

Longo programmable controller LPC-2.C05
6 NOTES
11
Table of contents