Design and selection
Operate the unit only within the specified supply voltage limits.
If the supply voltage exceeds the rated voltage limits the unit and
connected equipment might malfunction or could be damaged. It could
also become a fire hazard.
Do not operate beyond specification range.
Fire, malfunction or unit and connected equipment damage can result.
Please construct a backup system, such as making the
equipment or unit a multiple system, or designing a fail-safe in
advance to prevent damage due to the breakdown and the
malfunction of this product.
Mount the emergency stop outside of the enclosure so that it can
stop the system operation immediately and intercept the power
supply.
These instructions must be followed when using the Gateway
unit in an interlocking circuit:
•Provide valve interlocking by another system such as
mechanical protection.
•Check the Gateway unit regularly to ensure mechanical
protection.
There is a risk of getting injured if the interlock does not operate
correctly.
Wiring
Perform wiring correctly.
There is a possibility that a unit and connected equipment will be
destroyed if incorrectly wired.
Do not perform wiring while power is on.
If there is an explosive atmosphere present there is a risk of an
explosion.
There is also a possibility of failure of operation due to the damage of a
unit and connected equipment.
Do not lay wires or cables with power cable or high-voltage
cable in the same wiring route.
There is a possibility of failure of operation due to electrical noise on
the signal cable or a surge in the power cable. Separate the wiring of
reduced wiring system from power cables.
Confirm proper insulation of wiring.
With insulation failure (contact with other circuits, insulation failure
between terminals, etc), there is a risk of explosion if an explosive
atmosphere is present. There is also a possibility of damage to a unit
and connected equipment due to the applied excess pressure or current.
Operating environment
Do not use in an environment where water, chemicals, or oil
are present. Prevent dust and particles collecting on or around
the unit.
It will cause failure or malfunction.
Do not use in an area where a magnetic field is generated.
It will cause malfunction.
Do not connect or disconnect cables when the unit is powered.
Fire or an explosion may result if an explosive or combustible gas is
present.
Do not use in an environment with temperature cycle.
Heat cycles other than that of daily change of the temperature can effect
inside of the units.
Do not expose the wiring system to heat radiation from a heat
source located nearby.
It will cause failure or malfunction.
Do not use in an environment where a surge source more than
the CE marking standard allow is present.
Internal circuit elements can deteriorate or break when equipment
generating a large surge (electromagnetic lifter, high frequency induction
furnace, motor, etc.) is located near the wiring system. Provide surge
preventives, and avoid interface.
Use the wiring system equipment with surge absorber when a
surge-generating load such as relay or solenoid valve is driven
directly.
Do not expose the wiring system to vibration and impact.
It will cause failure or malfunction.
Adjustment and Operation
Do not allow short circuit of loads.
Connected equipment may be damaged by excess current flow if a load is
short circuit. Input unit fuse will break. Output and SI unit have protective
function for excess current flow, but it is possible that they will be damaged,
as the protective function does not cover all modes.
The SI unit should be used within the range of specifications given
below and in the product catalogue.
If labelled with X: special conditions apply:
1. Protect the SI unit from sources of heat which can generate surface
temperatures higher than the ATEX temperature classification.
2. Protect the SI unit and cables against all impact or mechanical
damage using a suitable ATEX compliant enclosure.
3. Protect the SI unit from direct sunlight or UV light using a suitable
protective cover.
4. Do not disconnect the M12 connectors before first switching off the
power supply.
5. Use only ATEX approved M12 connectors and use only shielded
cable to provide grounding.
6. Use only a damp cloth to clean the SI unit body, to avoid an
electrostatic charge.
Mounting
Do not drop, bump or apply excessive impacts
while handling.
Otherwise it can result in damage to the SI unit causing
failure or malfunction.
Hold the body for handling.
Otherwise it can result in damage to the SI unit causing
failure or malfunction.
Mount units using the proper tightening torque.
If a unit is tightened beyond the range of tightening torque,
the mounting screws, mounting brackets or unit may be
damaged
Do not mount the unit where it may be stepped on.
If the unit is stepped on it will be damaged.
Wiring
Avoid repeatedly bending or stretching the lead
wires.
Do not crush or strain the wire. It will cause the wire to
break and make the unit malfunction
Ground the reduced wiring system to a secure,
safe and noise-proof place
Grounding should be performed near the unit to shorten the
grounding distance.
Maintenance
Only clean the product with a damp cloth.
Do not wipe the product with chemicals such as benzene or
thinners. It will cause damage to the product.
Installation & Maintenance Manual
SI Unit
Series 56-EX500-S001/S101
Read this manual before using this product.
For future reference, please keep this manual in a safe place.
This manual should be read in conjunction with the current catalogue.
General recommendation
These safety instructions are intended to prevent a hazardous
situation and/or equipment damage.
These instructions indicate the level of potential hazard by label of
"Caution", "Warning" or "Danger".
Operator error could result in injury or
equipment damage.
Operator error could result in serious injury
or loss of life.
In extreme conditions, there is a possible
result of serious injury or loss of life.
•A system designer or a person who decides a system
specification should judge the compatibility of a reduced
wiring system.
Since the products specified here are used in various operating
conditions,their compatibility for the specific
wire saving
system
must be based on specifications or after analysis and/or tests to
meet your specific requirements.
•
Only trained personnel should operate pneumatically operated
machinery and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it
Assembly, handling or repair of wire saving systems should be
performed by trained and experienced operators.
•
Do not service machinery/equipment or attempt to remove
component until safety is confirmed.
1) Inspection and maintenance of machinery/equipment should only be
performed after confirmation of safe locked-out control positions.
2) When equipment is to be removed, confirm the safety process as
mentioned above. Switch off air and electrical supplies.
3) Before machinery/equipment is re-started, ensure all safety measures to
prevent sudden movement of actuators etc. (Supply air into the system
gradually to create backpressure, i.e. incorporate a soft-start valve).
•
Contact SMC if the product is to be used in any of the following
conditions:
1) Conditions and environments beyond the given specifications, or if
product is used outdoors.
2) Installations in conjunction with atomic energy, medical equipment, food
and beverage, or safety equipment.
3) Applications which have the possibility of having negative effects on
people, property or animals.
Special safety analysis is required.
Do not carry out operation or setting of this equipment with wet
hands.
It may cause an electric shock to the operator.
Maintenance
Do not disassemble, modify (including change of printed circuit
board) or repair.
An injury or failure can result.
Perform the following maintenance periodically in order to prevent
possible danger due to the unexpected.
Confirm wiring and screws are not loose.
Loose screws or wires may cause unintentional malfunction.
These instructions must be followed while in maintenance:
•
Turn off the power supply.
•
Stop the supplied fluid, exhaust the residual pressure and verify
the
release of fluid before performing maintenance.
Otherwise it can cause injury.
56-EX500
-
Q 01
SI Unit for SV series Manifold Valve
SI Unit for VQC series Manifold Valve
EX500-TF 09GB-B
Safety Instructions
Safety Instructions (continue)
Model Indication Method
Intended conditions of use
Design and selection
Ensure there is sufficient clearance for maintenance activities.
When designing an application, be sure to allow sufficient clearance for
maintenance and inspections.
The direct current power supply to be used should be UL1310 class
2 power supply when conformity to UL is necessary.
56-EX500
-
S 01
:n
:n
:
Caution
Warning
Danger
Output specification
0 NPN output (+ COM.)
1 PNP output ( - COM.)
Output specification
0 NPN output (+ COM.)
1 PNP output ( - COM.)
ATEX Category 3
ATEX Category 3
II 3G Ex nA II T5 X 5ºC≤Ta≤45ºC
II 3D tD A22 IP67 T52ºC X
C`
ATEX Marking Description
II 3G Ex nA II T5 X 5ºC≤Ta≤45ºC
II 3D tD A22 IP67 T??ºC X
Equipment Group II
Category 3
Gas (G) and Dust (D) environment
Ex - European standards apply
nA - Non-sparking apparatus
II - for all types of gas
T5 - temperature classification
tD - protected by enclosure
A22 - for zone 22
IP67 - Protection structure
Ta - Ambient temperature
T??ºC - Max. surface temperature
X - special conditions apply, see
instructions
Series 56-EX500-Q001/Q101
II 3G Ex nA II T5 X 5ºC≤Ta≤45ºC
II 3D tD A22 IP67 T54ºC X
C`
Tighten the screws which hold the SI unit to the SUP / WXH Block
assembly, with specified tightening torque (0.6Nm).
Refer to IMM of SV and VQC series for further details.
COM
PWR
C1
C2
56-EX500-S001/101
56-EX500-Q001/101
56-EX500-S001/101
56-EX500-Q001/101
EX500-TF 09GB-B
Na es and Functions of individual parts
Installation Outline with Di ensions
Communication connector M12 connector (8 pin, socket) : Connecting with Input Unit.
M12 connector (8 pin, plug) : Connecting with Gateway Unit.
Connecting block Solenoid valve (Single, Double)
Rated voltage 24VDC
Current consumption 100mA or less (at rated voltage)
Ambient temperature /
humidity
+5 to 45 / 35% to 85%RH (without
condensation)
Protection structure IP67
Current supply for block 0.3A Max.
Weight 56-EX500-S001/101 : 115g
56-EX500-Q001/101 : 105g
56-EX500-S001/101
56-EX500-Q001/101
Number of connecting
block
Double solenoid valve : 8 block Max.
Single solenoid valve : 16 block Max.
Specification
SUP/EXH Block Ass’y
M3X10: 2 pcs
Power Save Block
SI Unit for VQC series Manifold
Power LED
Communication LED
Communication connector
Connect to Input Unit
Connect to Gateway Unit
Communication connector
Power LED
Communication LED
Communication connector
Connect to Input Unit
Communication connector
Connect to Gateway Unit
SI Unit for VQC series Manifold
SI Unit for SV series Manifold
SUP/EXH Block Ass’y
SI Unit for SV series Manifold M3X30 : 4 pcs
AUSTRIA (43) 2262 62280 NETHERLANDS (31) 20 531 8888
BELGIUM (32) 3 355 1464 NORWAY (47) 67 12 90 20
CZECH REP. (420) 541 424 611 POLAND (48) 22 211 9600
DENMARK (45) 7025 2900 PORTUGAL (351) 21 471 1880
FINLAND (358) 207 513513 SLOVAKIA (421) 2 444 56725
FRANCE (33) 1 6476 1000 SLOVENIA (386) 73 885 412
GERMANY (49) 6103 4020 SPAIN (34) 945 184 100
GREECE (30) 210 271 7265 SWEDEN (46) 8 603 1200
HUNGARY (36) 23 511 390 SWITZERLAND (41) 52 396 3131
IRELAND (353) 1 403 9000 UNITED KINGDOM (44) 1908 563888
ITALY (39) 02 92711
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)
Specifications are subject to change without prior notice from the manufacturer.
© 2009 SMC Corporation All Rights Reserved.
Contact
Pollution Degree Pollution Degree 2

This manual suits for next models

3

Other SMC Networks I/O System manuals

SMC Networks EX245-SPN1A User manual

SMC Networks

SMC Networks EX245-SPN1A User manual

SMC Networks 56-EX600-SEN7-X10 User manual

SMC Networks

SMC Networks 56-EX600-SEN7-X10 User manual

SMC Networks EX600-WPN User manual

SMC Networks

SMC Networks EX600-WPN User manual

SMC Networks EX600-SDN Series User manual

SMC Networks

SMC Networks EX600-SDN Series User manual

SMC Networks 56-EX500-IB1 Instruction Manual

SMC Networks

SMC Networks 56-EX500-IB1 Instruction Manual

SMC Networks EX250-SCA1A Instruction Manual

SMC Networks

SMC Networks EX250-SCA1A Instruction Manual

SMC Networks EX600-SPR Series User manual

SMC Networks

SMC Networks EX600-SPR Series User manual

SMC Networks EX245-SPN1 User manual

SMC Networks

SMC Networks EX245-SPN1 User manual

SMC Networks EX500-IE1 Instruction Manual

SMC Networks

SMC Networks EX500-IE1 Instruction Manual

SMC Networks EXW1-BMJA Series User manual

SMC Networks

SMC Networks EXW1-BMJA Series User manual

SMC Networks EX600-AXA Instruction Manual

SMC Networks

SMC Networks EX600-AXA Instruction Manual

SMC Networks EX600-WEN User manual

SMC Networks

SMC Networks EX600-WEN User manual

SMC Networks EX245-EA2 Series User manual

SMC Networks

SMC Networks EX245-EA2 Series User manual

SMC Networks EX250-IE1 User manual

SMC Networks

SMC Networks EX250-IE1 User manual

SMC Networks EX600-WEN User manual

SMC Networks

SMC Networks EX600-WEN User manual

SMC Networks EX600 Series User manual

SMC Networks

SMC Networks EX600 Series User manual

SMC Networks EX600-DYPB Instruction Manual

SMC Networks

SMC Networks EX600-DYPB Instruction Manual

SMC Networks EX250-IE2 User manual

SMC Networks

SMC Networks EX250-IE2 User manual

Popular I/O System manuals by other brands

Contec COM-2PD(PCI)H user guide

Contec

Contec COM-2PD(PCI)H user guide

Contec COM-1C-LPE user guide

Contec

Contec COM-1C-LPE user guide

National Instruments FIELDPOINT FP-PWM-520 operating instructions

National Instruments

National Instruments FIELDPOINT FP-PWM-520 operating instructions

Bosch Rexroth IndraControl S67 Series manual

Bosch

Bosch Rexroth IndraControl S67 Series manual

Phonetics Annunciator Module SCADA 3000 user manual

Phonetics

Phonetics Annunciator Module SCADA 3000 user manual

Omron DST1-ID12SL-1 Operation manual

Omron

Omron DST1-ID12SL-1 Operation manual

M-system R30PA2 instruction manual

M-system

M-system R30PA2 instruction manual

RME Audio Digiface Ravenna user guide

RME Audio

RME Audio Digiface Ravenna user guide

turck BL20-B3S-SBB Hardware and engineering

turck

turck BL20-B3S-SBB Hardware and engineering

iSystem IOM6 ADIO user manual

iSystem

iSystem IOM6 ADIO user manual

Stahl IS1 manual

Stahl

Stahl IS1 manual

Bosch Rexroth IndraControl S67 Series Application description

Bosch

Bosch Rexroth IndraControl S67 Series Application description

Beckhoff KL2819 Documentation

Beckhoff

Beckhoff KL2819 Documentation

Extron electronics USP 507 installation guide

Extron electronics

Extron electronics USP 507 installation guide

AMCI 4402 user manual

AMCI

AMCI 4402 user manual

9dot NCORE manual

9dot

9dot NCORE manual

ICP DAS USA I-7000 Series quick start guide

ICP DAS USA

ICP DAS USA I-7000 Series quick start guide

ICOP Technology QEC-R D Series user manual

ICOP Technology

ICOP Technology QEC-R D Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.