Spin-W SW-G190E User manual

GSM INTRUSION ALARM SYSTEM
INSTRUCTION MANUAL
GSM - PSTN - SMS - TOUCH
GSM Wireless Security Alarm System

Printed in Shenzhen
RE: GSM-August-2013
SECURE YOUR HOME AND BUSINESS

Key Features
• Smart touch keypad with 4 line message LCD display
• Quad-band GSM communication, works with SIM card
• Calender, ve personal emergency phone numbers
• One central monitoring station phone number
• Alarm notication via phone call or SMS
• Built-in speaker and microphone
• Remote two-way intercom
• Extra SMS phone number for system's status
• Alarm memo, entry delay, exit delay
• Hybrid alarm, 30 wireless zones, 4 hardwired zones
• Advanced zone attribute, user-friendly zone names
• Temperature display and relay signal output
• Support wireless LCD/LED keypad and wireless siren
• Support user code and installer code
• 100 alarm log
• SMS alert, when system: Arm/Disarmed, sensor's low battery, AC power
failure, phone line disconnect
• Reset factory design
• Built-in siren
• Alarm communication via ADEMCO Contact ID protocol
• Backup rechargeable battery, last more than 24 hours
• Work with CCTV system, IP camera
3

Technical Information
• Power supply: AC=100 ~ 230V 50Hz/60Hz
• Working voltage: DC12V 1A
• Static current: < 35mA (when not in charging)
• Alarm current: < 120mA
• Backup Battery: 3.7V 800mA
• Standby time: Around 24 hours
• Charging time: 8 hours
• GSM frequency: 850/900/1800/1900MHz
• GSM Transmission power: 2W
• Receiving and emitting frequency: 433MHz (868MHz optional)
• Wireless transmission distance: ≤100 m (Open space)
• Working condition:Temperature: -10ºC ~ 50ºC Humidity:5% ~ 80%
4

Font panel View
q
w
e
r
t
y u i o
a
s
d
f
q LCD Display w GSM Signal LED e Fire Alarm
r Burglary t Medical Help y SpeedDial Button
u Home/Stay Arm i Down/Disarm o SET/Exit
a Up/Away Arm s Left/Delete/Log/* d Right/Phone Call/#
f Conrm/Save
5

Back panel View
| +12V- |31 32 33 34 |-BELL+|No Com|
Anti-Tamper Switch
Installation Bracket
Speaker
Wired Connection
DC 12V input jack
ON OFF
Telephone line
SIM Card Slot
Reset
6

Arm/Disarm System
Activate Away Arm
In keypad, touch to activate Away Arm.
Remotely via SMS, send SMS content: xxxx1
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 1 to activate the Away Arm.
Activate Stay Arm
In keypad, touch to activate the Stay Arm
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 2 to active the Stay Arm
Disarm
In keypad, touch then, input xxxx+OK
Remotely via SMS, send SMS content: xxxx0
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 3 to disarm.
Notice
"xxxx" is the current user code, default user code
is "1111", and default admin/installer code is "1234"
The system is working with separate wireless LCD/
LCD keypads, for activate and deactive operation,
please refer to manual of wireless keypad.
7

Voice Memo/Phone Call
Quick Alarm
Touch for 2 seconds to trigger re alarm.
Touch for 2 seconds to trigger burglary alarm.
Touch for 2 seconds to trigger medical help.
Recording Voice Memo
When system is in Disarm status, touch
for 2 seconds for recording memo.
Maxim recording time is 10 seconds.
Playback Voice Memo
When system is in Disarm status, touch
the system will playback the voice memo.
Check System Log
The system can record 100 pieces event log, you
can touch to check these log, when system
is not in setup status.
OK
OK
Make Phone Call
When alarm system in disarm status, you can
make phone call via alarm panel. Touch then
input the phone number, touch to make
phone call.
The function enables alarm system can be used as
a portable cell phone.
Pick up Phone Call
If there is a phone call to alarm system, the conrm
circle's LED will light up, and you can touch
to pickup phone call.
Speed Dial Function
When touch " A" or "B" key on the keypad, the
alarm system will make the speed dial phone call
with preset phone numbers (eg: the person that
needs to be notified in case of an emergency, a
carer, Mum or Dad).
OK
OK
X
8

Basic Alarm Setting
Enter into Setting Status
When system is in Disarm status, touch
then input admin code, default "1234", touch "OK"
for conrm, to enter into setting status.
System Time setting
When system is setting status, choose the "Time
Setting" for modifing the current time. The time
will automatically back to default, once the alarm
system is complete OFF.
Time Setting
Phone No. Setting
SMS Setting
Record >
Time Setting
04:54:08
09/11/2013
THU >
Touch " ▲▼ " to select and " " to delete the
default date, then enter with new time (XX hours,
XX minute, XX second). Do same procedure for
date.
Touch " ▼ " and " ◄► " select the week, touch
"OK" to conrm all settings.
X
Alarm Receiving Phone Number
This alarm system can totally preset up to 5
personal emergency phone numbers for alarm
receiving.
Time Setting
Phone No. Setting
SMS Setting
Record >
Phone Groups 1
Alarm Call >
28901540
Touch "◄► " to select the Alarm Call or Alarm
SMS, then touch "▼ " , you can input the number.
1st and 2nd group for setting Alarm SMS, 3rd
group for setting Alarm SMS or Alarm Call, 4th&5th
groups for setting Alarm Call.
Touch " " you can delete the existing phone
number.
You need touch "OK" to save, and navigate into
next phone number setting menu.
Notice: Maximum digitals for phone number input
is 15.
X
9

Basic Alarm Setting
SMS Number for System Status
The alarm system can preset one phone number
for receiving SMS report of system's status,
including AC power recover, Arm/Disarm, PSTN
OFF, Host Low Voltage, Sensor Low Voltage.
Time Setting
Phone No. Setting
SMS Setting
Record >
SMS Phone No.
1388888888888
AC Power Recover
OFF >
Arm/Disarm SMS
OFF >
Host Low Volt
OFF >
Sensor Low Volt
OFF >
Touch " " to delete exist phone number, enter new mobile phone number. Touch " OK" to save the
phone number, it will navigate to event report selection.
Touch "◄►" to select enabled or disable the event report.
AC power recover means when external electricity is recover, the alarm system will send SMS.
Arm/Disarm SMS means when alarm system is Armed or Disarmed, the system will send SMS.
PSTN Off means when fixed phone line is cut or with trouble, the system will send SMS.
Host Low Volt means when backup battery is low, the system will send SMS.
Sensor Low Volt means when battteries run out in wireless sensors, it will send SMS.
X
10
PSTN Off
OFF >

Advanced Alarm Setting
Record Voice Memo
The system allows user to record up to 10 seconds
voice memo. When alarm phone call is picked up,
press "5" to listen the voice memo.
Record
OFF >
Record
R e c o r d i n g T i m e
10
Touch "◄►" to choose "On" to record voice, and
touch "OK" to start voice recording.
Arm Delay/Exit Delay
The Arm delay or exit delay can allow user to exit
protected area before system is Armed. The time is
adjustabe from 00 to 59 seconds.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting >
Arm Delay
10
Seconds
Alarm Delay/Entry Delay
The alarm delay or entry delay can allow user to
set alarm delay zones before system set alarm off.
This allow user enter into specic detection area to
disarm the system without triggering alarm.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting >
Alarm Delay
10
Seconds
Touch " " to delete exist data, and input new
seconds e.g 10. It accpet time between 00 - 59.
Touch "OK" to save.
Notice: You need go to [Zone attribute] to enable
which zones are belong to this function, therefore it
can work.
X
Touch " " to delete default data, and enter new
time. Touch "OK" to save.
X
11

Advanced Alarm Setting
Siren Setting
It allows siren time setting for each of zones. The siren
time can be set from 00-59 minutes. User can choose
whether use built-in siren or not. The function is useful, if
user want to choose mute alarm.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting >
Zone No.
00
Siren Time
01
Minute
Built-in Siren
On >
Touch " " to delete the zone number, and input new zone number from 00-34. Touch "OK" to save
Touch " " to delete the siren time, and input new siren time, "00" means disable. Default value is 01
Touch "◄►" to choose "On" to enable built-in siren, and touch "OK" to save.
X
X
Tone Setting
Tone setting means the alarm system will make
"beep" sound, when detects system event, such as
telephone line cut, Arm/Disarm, Temperature Alert.
Arm Delay
Alarm Delay
Siren Setting
Tone Setting >
PSTN OFF Tone
Off >
Arm/Disarm Tone
Off >
Arm/Disarm Beep
Off >
Temp Alert
Off >
▲
12

Call in Setting
Call in Setting
The system can receive the phone call via telephone line and GSM. It allow user to set the ring times
from 1 to 9. When the ring time reach to preset times, it will pick up the phone call for remotely control.
Call in Setting
Program&Delete
Zone Attribute
Upload >
PSTN Call in Tone
9
GSM Call in Tone
3
Program&Delete
Use this function to program/delete wireless sensors and accessories (remote keyfob, wireless LED/LCD
keypad). The wireless zone number is from 00-30. Zone 00 is for programming wireless remote keyfob or
keypads.
Touch " " to delete exist data, It accpets ring time between1-9. Touch "OK" to save.
X
Call in Setting
Program&Delete
Zone Attribute
Upload >
Zone No.
00
Program
Delete
Zone No.
00
Programming
Zone No.
00
Success
Delete
13

Zone Programming
Touch " " to delete the zone number, and input new zone number from 00-30. Touch "▲▼" to choose
[program], then touch "OK", the LCD will display [Programming]. Trigger the wireless sensors/accessories
for two times, the LCD display [Success], touch "OK" to save, you can continue to enroll more sensors.
Touch " " to delete the zone number, and input new zone number from 00-30. Touch "▲▼" to choose
delete, the LCD will display [Success], touch "OK" to save. This will erase the current sensors in the zone
from the alarm system.
X
X
Zone Attribute
The system has advanced zone attribute, it allow user to choose each of attribute for the zones, it helps
user to customize the system, which can be more suitable for specic installation. Ensuring the zones with
correct attribute, therefore sensors can work properly.
Call in Setting
Program&Delete
Zone Attribute
Upload >
Zone No.
01
Activate >
0 Defence Line >
00Help >
Alarm Delay Off >
Zone Chime Off >
Smart Sensor Off >
Touch " " to delete the zone number, and input new zone number from 00-30. Touch "OK" navigate to
next menu. Touch "OK" you will navigate to last level menu.
Bypass Sensor: Touch ""◄►" to choose "Disable" to deactivate/bypass this zone.
Zone type: Touch "▲▼" to choose defense line, touch "◄►" to change the value from including 0, 1, 2.
Sensor type: Touch "▲▼" to choose sensor type, touch "◄►" to change the sensor type.
Alarm Delay: Touch "▲▼" to choose alarm delay off, touch "◄►" to enable or disable the alarm delay.
Zone Chime: Touch "▲▼" to choose zone chime off, touch "◄►" to enable or disable this function.
X
14

Zone Attribute
Smart Sensor Off: Touch "▲▼" to choose smart sensor off, touch "◄►" to enable or disable this
function.
Notice:
[0 Defense line] means re, panic alarms, which are belong to 24 hours emergency zone. It will trigger the
alarm system, even the system in disarm status.
[1 Defense line] means perimeter protection, which is belong to perimeter zone. It will work when alarm
system in both Away Arm and Home Arm modes.
[2 Defense line] means interior protection, which is belong to motion zone. The sensors in this zone will
be activated when system is in Away Arm mode, but will be de-activated, when system in Home Arm/Stay
Arm mode.
Zone Number Zone Type Sensor Type Sensors
00 N/A Wireless Remote Keyfob Maximum 10 pcs
01 ~ 10 Emergency Zone Wireless Sensors Panic, Smoke, Gas Leak
11 ~ 20 Perimeter Zone Door sensor, IR beam
21 ~ 30 Motion Zone PIR motion sensor
31 ~ 34 Hardwired Zone Hardwired Sensors
Default Zone Type
Wireless Remote Wireless Door Sensor Wireless PIR motion Wireless Smoke
00 12 21 02
Default zone number for sensor and keyfob for standard alarm kit
15

Monitored Alarm Setting
Upload
The system can either be used as self-monitoring system or monitored by security company. It's
compatible with ADEMCO Contact ID protocol for alarm monitoring. If you want to link the alarm system
into alarm monitoring centre, you need to do this operation. More over, the system can not only upload
alarm information, also can upload system's status to central monitoring station.
Call in Setting
Program&Delete
Zone Attribute
Upload >
Center Phone No.
911
User Code
0001
Upload Status?
Off >
Touch " " to delete exist number, and input new alarm monitoring centre number. Touch "OK" to save,
then navigate to next level menu, touch " " to delete default user code, and input your user code,
touch "OK" to save, then navigate to next level menu, touch "▲▼" to choose disable or enalbe upload
status, touch "OK" to save, navigate to next status selection menu.
AC Fail Upload
Off >
Host Low Volt
Off >
Sensor Low Volt
Off >
Manual Test
Off >
Period Test
00000
▲
X
X
16

User/Admin Code Setting
User Code
Navigate to this menu, user can modify the user
code. The user code with authorization for Arm/
Disarm the system via keypad, SMS, phone call,
mobile applications (APP). The default user code
is "1111".
Password Setting
Pin Setting
Reset
Time Arm/Disarm >
Password Setting
####
Admin Code
Navigate to this menu, user can modify the admin
code. The admin code with authorization for
programming the system. The default admin code
is "1234".
Password Setting
Pin Setting
Reset
Time Arm/Disarm >
Pin Setting
####
Reset
Navigate to this menu, user can reset the alarm
system. The system will reset to factory status.
If user have done wrong programming, can not
be solved, then you can use reset function. It will
erase all the user's programming data.
Password Setting
Pin Setting
Reset
Auto Arm/Disarm >
Reset
Off >
Touch "◄►" to choose "On" , then touch "OK" to
reset the alarm system.
17

Auto Arm/Disarm
Auto Arm/Disarm
This function can make the alarm system automatically Arm/Disarm in preset time for
everyday.
Password Setting
Pin Setting
Reset
Auto Arm/Disarm >
SUN
--:-- Away Arm
--:-- Stay Arm
--:-- Disarm
MON
--:-- Away Arm
--:-- Stay Arm
--:-- Disarm
Touch " " to delete the default time, and input new time e.g: 1200, touch "▲▼" navigate to next time
setting, touch "OK" to save, it will navigate next day for auto arm/disarm setting.
Notice:
The time format should be 12:00, hours then minutes. Wrong time input can not be saved.
X
Temperature Control
This system is built-in temperature sensor for monitoring onsite temperature. You can set the upper limit
and lower limit to make temperature alert (NC. dry contract output).The temperature range can be from
00° ~ 70° . If you enabled SMS notification, then it will send the text message alert. If choose output OFF,
then the dry contract will be used as alarm output.
Temp Control
Speed Dial
Temp Upper limit
32
Output On >
Temp Lower limit
15
Output Off >
18

Speed Dial Phone Call
Speed Dial
There are two special buttons on the keypad, they are "A, B". User can preset phone number for this two
buttons. When system is in Disarm status, the user can touch "A" or "B" for making speed dial phone call.
The phone number can be the person that needs to be notied in case of an emergency, a carer, Mum or
Dad.
Temp Control
Speed Dial
A P h o n e N o .
1008610086 >
B P h o n e N o .
10011001 >
Notice:
After nish the setting, you can touch to exit setting status. The system will automactially exit setting
status, when without any operation on keypad.
19

Alarm Handle for User
Receiving Alarm SMS
Once an alarm occurs, the system will send SMS as long as user choose for alarm SMS notication. The
system will send SMS with below content:
(0001)Alarm System: 11 Zone Door Sensor Alarming
20
Inquiry System's Status
The system allow user to inquiry the system's status, send "User code + C" text message to alarm
system, alarm will reply text message inform you whether it's Armed or Disarmed.
SMS Content:XXXXC
Table of contents