SportNeb Express 9R-023 series User manual

666001-6310 V1.1
Compressor Nebulizer
Instruction Manual
Part No. : 3055
SAVE THESE INSTRUCTIONS.
READ ALL INSTRUCTIONS BEFORE USE.
Model No: 9R-023 series
CAUTION - U.S. Federal Law restricts this device to
sale by or on the order of a physician.
This product has been tested and successfully
approved with the following standards:
EN 60601-1
EN 60601-1-2
Contents
IMPORTANT SAFEGUARD…………………………1
Introduction……………………………………………2
Product Description…………………….…………..3
Operation………………………………………..…….4
Cleaning………………………………………………..5
Storage……………………………………………….6
Maintenance…………………………………………7
Troubleshooting……………………………………8
Specifications.………………………………………..9
1. IMPORTANT SAFEGUARDS
DANGER - To reduce the risk of electrocution:
1. Always unplug this product immediately after using.
2. Do not use while bathing, showering, dish washing, or close
to water sources of any kind.
3. Do not place or store product where it can fall or be pulled
into a tub or sink.
4. Do not place in or drop into water or other liquid.
5. Do not reach for a product that has fallen into water. Unplug
immediately.
WARNING - To reduce the risk of burns, electrocution, fire or
injury to persons:
1. This product should never be left unattended when plugged
in.
2. Close supervision is necessary when this product is used by,
on or near children or invalids.
3. Use this product only for its intended use as described in this
manual. Use this product only under doctor’s direction. Do
not use attachments not recommended by the manufacturer.
4. Never operate this product if a) it has a damaged cord or
plug, b) it is not working properly, c) it has been dropped or
damaged, d) it has been dropped into water. Return the
product to a specified service center for examination and
repair.
5. Keep the cord away from heated surfaces.
6. Never block the air openings of this product or allow objects
to fall or be inserted into the air vent openings or place it on a
soft surface such as bed or couch, where the air openings
may be blocked.
7. Never use while sleeping or feeling drowsy.
8. Never drop or insert any object into any opening or hose.
9. Do not use in outdoors or operate where aerosol (spray)
products are being used or where oxygen is being
administered in a closed environment such as an oxygen
reservoir.
NOTE, CAUTION , SYMBOLS AND WARNING
STATEMENTS:
NOTE : Indicates information that user should pay special
attention to.
CAUTION : Indicates correct operating or maintenance
procedures in order to prevent damage to or destruction of
the equipment or other property.
WARNING : Calls attention to a potential danger that
requires correct procedures or practices in order to prevent
personal injury.
O Off, disconnection from the mains
I On, connection to the mains
~Alternating current
IPX0 Enclosed equipment without protection against ingress
of water
Attention
Class II
“BF” symbol, indicate this product is according to the
degree of protecting against electric shock for the type
BF equipment.
Disposal of Electrical & Electronic Equipment (WEEE):
This product should be handed over to an applicable
collection point for the recycling of electrical and
electronic equipment. For more detailed information
about the recycling of this product, please contact your
local city office, household waste disposal service or the
retail store where you purchased this product.
2. Introduction
2.1 Intended Use
The SportNeb eXPRESS Compressor Nebulizer System
is intended to provide a source of compressed air for
aerosol therapy. It is used in conjunction with a jet
(pneumatic) nebulizer to produce medicated aerosols for
inhalation by pediatric and adult patients with respiratory
symptoms.
CAUTION - Indications for therapy include asthma,
chronic bronchitis, infection of the upper respiratory
tract, chronic obstructive pulmonary disease and
other respiratory disorders in accordance with a
medical doctor’s prescription. Except the usage
mentioned above, please do not use this product for
any other purpose. This device can be used with
adults or pediatric patients under physician’s
prescription.
2.2 Safety Precaution Instruction
When using this electrical product, especially when
children are present, one should always follow basic safety
precautions. Do not install, maintain or operate this
equipment without reading, understanding and following
the proper SportNeb eXPRESS Compressor Nebulizer
System instruction manual, otherwise injury or damage
may result. Important information is highlighted by using
the following bulletin:
DANGER:Urgent safety information for hazards that will
cause serious injury or death.
WARNING:Important safety information for hazards that
might cause serious injury or property damage.
CAUTION:Information for preventing damage to the product.
For 120V only-
This appliance has a polarized plug (one blade is wider
than the other). To reduce the risk of electric shock, this
plug is intended to fit into a polarized outlet only one way. If
the plug does not fit fully into the outlet, reverse the plug.
If it still does not fit, contact a qualified electrician. Do not
modify the plug in any way.
3. Product Description
1. Power Switch
2. Filter Cap (disposable filter inside)
3. Air-Outlet Connector
4. Integrated Carrying Handle
5. Power Cord
6. Tubing Holder
7. Cooling Air Openings

666001-6310 V1.1
4. Operation
NOTE - Before initial operation, the nebulizer cup
assembly should be cleaned following instructions
described in the “Cleaning” section.
WARNING - Before connecting the power cord, make
sure the I/O (ON/OFF) switch is in the O (OFF) position.
The plug is also served to disconnect the device.
L’appareil est également muni d’une fiche de
connexion à l’électricité.
4.1 Daily Use Operation
CAUTION - The SportNeb eXPRESS Compressor
Nebulizer System is designed for intermittent use
only. Do not operate it continuously for more than 30
minutes for a single use without turning it off and
following a cooling period for least 30 minutes.
1. Before each use inspect the SportNeb eXPRESS
Compressor and nebulizer cup assembly for damage
or wear, replace as needed.
2. Place the SportNeb eXPRESS Compressor on a
table or other flat stable surface. Be sure you can
easily reach the controls when seated. Do not use
this device on the floor.
3. With the power switch in the O (OFF) position, plug
the power cord into an appropriate electrical wall
outlet.
4. Connect one end of the tubing to the compressor
air-outlet connector.
5. Assemble the nebulizer cup and add indicated
medication to the nebulizer’s cup before use.
6. Attach the other end of the tubing into the air-inlet
connector founded at the bottom of the nebulizer cup.
7. Turn on the SportNeb eXPRESS Compressor by
pressing the power switch to the I (ON) position and
begin treatment.
8. If treatment needs to be interrupted, simply press
power switch to O (OFF) position.
9. When the treatment is complete, turn off the
compressor by pressing the power switch to O (OFF)
position and unplug the unit from the electrical outlet.
Equipment not suitable for use in the presence of a
flammable anesthetic mixture with air or with oxygen
or nitrous oxide. This device has no AP or APG
protection.
NOTE : L’équipement ne peut être utilisé s’il y a
risque de mélange d’un anesthésique inflammable
avec l’air ou l’oxygène ou oxyde nitreux.
CAUTION - During the treatment, the patient should
not touch the outer case due to expected rise in unit
temperature.
4.2 Safety Overload
NOTE - Do not exceed 30 minutes of continuous
operation.
1. The motor of this device has a built-in thermal
overload protector. Should the motor overheat, the
protector will automatically shut off the motor. Should
this occur, turn the I/O (ON/OFF) switch to the O
(OFF) position and allow the motor to cool down for
approximately 30 minutes before turn it on again.
2. If the overload protector shuts off the motor frequently,
you may have an unstable voltage situation.
3. If the unit shuts down and cannot restart, it may need
to be replaced. Call your provider immediately.
5. Cleaning
5.1 Compressor Outer Case Cleaning
WARNING - Electric shock hazard. Do not remove
outer case of this unit. All disassembly and
maintenance of this unit must be done by a qualified
service technician. Refer servicing to qualified service
personnel.
WARNING - This unit does not require oil. Do not
attempt to lubricate any internal parts.
WARNING - Unplug unit before cleaning. Do not
submerge in water for cleaning.
1. Wipe the main unit with a damp cloth every few days
to keep it dust-free.
2. Do not use any powdered type cleaners or soap. Do
not submerge the unit into water.
5.2. Nebulizer Cup Cleaning
All parts of the disposable nebulizer, except tubing, should
be thoroughly cleaned after each use. If your doctor
specifies a specific cleaning procedure, follow that
procedure.
WARNING -To prevent possible risk of infection from
contaminated medication, cleaning of the nebulizer is
recommended after each treatment.
1. After each use, disassemble the nebulizer cup, tee
and mouthpiece completely, wash all parts in warm
soapy water and rinse thoroughly. Allow to air dry.
Store in a clean dry location.
2. Once daily, after washing as above, soak nebulizer
components in a fresh solution consisting of one part
warm water and one part white vinegar for 30 minutes
followed by a warm water rinse.
NOTE - The disposable nebulizer kit is for single
patient use only.
NOTE – Please follow national requirements to
dispose the unit properly.
6. Storage
Keep the unit and accessories dry. Avoid direct sunshine.
7. Maintenance
7.1 General Information
1. This unit is oil-less. Do Not Lubricate.
2. Risk of electric shock. Do not disassemble the main
unit.
3. All maintenance must be performed by a qualified
service personnel.
7.2 Filter Change
NOTE - Change the filter once every
month or when filter turns gray. Please
follow the below instructions as right
figures.
1. Open the filter cap.
2. Remove dirty filter with a small,
pointed object. Discard the filter.
3. Replace with a clean filter.
Additional filters should be
purchased from your provider.
4. Put the filter cap back.
CAUTION - Do not use cotton or any other material as
a filter. Do not wash or reuse the filter. Do not operate
the unit without a filter.
8. Troubleshooting
If your SportNeb eXPRESS Compressor Nebulizer fails to
function, consult the Troubleshooting guide below. If the
problem persists, consult your equipment provider.
Problem Cause and Solution
Device
doesn’t
operate.
‧Check if plug is properly fit into an
appropriate electrical outlet.
‧When device has been run continuously
for over 30 minutes right before using, an
auto shut down may activate by built-in
thermal protector, cool down device for
30 minutes before next usage.
Weak
Nebulization
‧Check for proper electrical voltage.
‧Check tubing for blockage or air leakage at
connection to SportNeb eXPRESS
compressor or nebulizer cup, replace as
needed.
‧Check the nebulizer cup if it is properly
assembled and not damaged. If there is
any damage, replace as needed.
‧Check if filter is too dirty, replace as
needed.
9. Specifications
Electrical Rating
(Note: Refer to the rating
label on the product)
100VAC,60Hz,1.2A
120VAC,60Hz,1.2A
( For 120V System)
230VAC,60Hz,0.6A
100VAC,50Hz,1.2A
230VAC,50Hz,0.6A
230V-240VAC,
50Hz, 0.6A
Maximum Compressor
Pressure ≧30 psi ≧30 psi
Operating Flow Rate ≧5.5 lpm ≧5.0 lpm
Nebulization Rate 0.2 - 0.3 ml/min
Particle size 0.5 ~ 5 microns*
Classification
Class II.
BF equipment.
IPX0
No AP/APG protection.
Applied part Mouthpiece or Nasal mask
Dimensions (W x D x H) 14.6 ×20.3 ×9.5 cm /
5.7” ×7.9” ×3.7”
Weight (approx.) 1.8 kg / 4.0 lb
Fuse (see note 3) T5A 250VAC for 120V system,
T1.6A 250VAC for 230V system
Warranty 3 Years
Operation: 10℃to 40℃/ 50℉to 104℉
Storage: -15℃to 50℃/ 5℉to 122℉
Temperature
Transport: -15℃to 70℃/ 5℉to 158℉
Operation: 10% to 90%RH non-condensing
Storage: 10% to 90%RH non-condensing
Environment
Humidity
Transport: 10% to 90% RH non-condensing
All specifications are subject to change without notice.
Note:
1. *Values are determined by supplier’s nebulizer.
2. Consult distributor(s) or EU representative(s) for
additional technical documents.
3. The Nebulizer is fitted with a fuse as specified in
the Specification column, it is designed to be
maintained by the manufacturer or its agents.
Users are not allowed to open the cover to
replace a blown fuse.
DISTRIBUTED BY:
Table of contents