manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Stanley
  6. •
  7. Water Pump
  8. •
  9. Stanley STAPB70 User manual

Stanley STAPB70 User manual

OWNER’S MANUAL
This appliance can be used by children aged from 8 years and above and any persons, provided
they have experience and knowledge regarding the use of the product, or supervision or instruction
regarding the use of the appliance in a safe way, and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be completed by children.
Attention!
If the appliance or the supply cord is damaged, it must be repaired by manufacturer, its service agent
or qualied person.
Meaning of crossed – out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact you local government for information regarding the collection systems available.
WARNING
!
- 2 -
1. Applications
2. Model Description
3. Hydraulic Performance Curve - STAPB70
4. Hydraulic Performance Curve - STAPB120
5. Safety Precautions
6. Product Structure
7. Dimension
8. Pipeline Installation
9. Electrical Connection
10. Start-up and Maintenance
11. Troubleshooting
Contents
- 8 -
8. Pipeline Installation
This product should be installed and maintained by a qualied person, or someone who has read this manual and
understands the use requirements. Installation and operation should be in accordance with local regulations and
recognized operation standards. Install pipelines properly as stipulated in the manual, and conduct frost protection
measures for the pipeline.
WARNING
!
1. For the pump installation, the inlet pipe
should be as short as possible with the least
turnings. The pump should be installed in a
ventilated and dry environment. It could be
installed outside, provided having proper
covering to prevent rain and wind.
2. For pipeline use, valves should be installed
on inlet and outlet pipelines and the inlet
pipeline should be installed with a check valve.
OWNER’S MANUAL
- 9 -
A:
1. Foot valve
2. Inlet pipe
3. Tie-in
4. Filling plug
B: Installation precautions for inlet pipelines
1. While installing the electric pump, do not use too
soft rubber tube for the inlet pipeline. This avoids
it being sucked at.
2. The foot valve should be vertically placed and
installed 30cm from water bottom to avoid
sucking in sands and stones (B2);
3. Joints of the inlet pipelines should be sealed with
the least elbows, so no water can be sucked.
4. Diameter of the inlet pipe should be at least in
accordance with that of the water inlet, so as to
avoid too much water loss which will inuence
outlet performance.
5. Pay attention to drop of water level while using.
The foot valve should not be above the water
surface (B1).
6. In case the inlet pipe is longer than 10m or its
lifting height exceeds 4m, the pipe diameter
should exceed diameter of water inlet of the
pump.
7. Ensure the pump will not be affected by pipeline
pressures while installing the pipelines.
8. Filter should be installed in inlet pipelines so as
to avoid solid particles to enter into the electric
pump.
C: Installation Precautions of the outlet
pipeline
Pipe diameter of the outlet pipeline should be at
least in accordance with that of the water outlet,
so as to reduce its voltage drop, ow rate issues
and to reduce the noise emitted by the pump.
5. Drain plug
6. Electric pump
7. Valve
- 10 -
9. Electrical Connection
Unless the power is off, do not touch the wiring in the junction box.
The electric pump should have reliable grounding to prevent current leakage with leakage protection switch
being equipped.
WARNING
!
1. Electrical connection and protection should be conducted according to stipulations. Specication
of working voltage is marked on the nameplate; please ensure the motor is in accordance with
power supply.
2. In case the working area of the electric pump is too far from the power supply, power
transmission lines should be of a heavier gauge, otherwise the electric pump cannot work
normally because the voltage drop is too dramatic.
3. In case the electric pump is used outdoor, extended lines should apply rubber cables for outdoor
use.
4. Check rotation of the motor (three-phase motor)
5. Check whether operation of the electric pump is normal, rotation is correct, which could be
observed from the fan blade terminal, e.g. clockwise rotation means correct direction. In case the
rotation is incorrect, cut off power and exchange the two power leads.
OWNER’S MANUAL
- 11 -
10. Start-up and Maintenance
Do not start up the pump before the pump chamber is lled with water.
Do not touch the electric pump unless its power has been cut off for at least 5 minutes.
Do not dismount the pump body unless water in the pump chamber is emptied.
WARNING
!
Rotate the fan blade before startup, check
whether the pump rotation is exible and then
unscrew the water-lling plug, ll the pump
chamber with clean water from the water
injection hole, then tighten the plug screw
after gas has been completely discharged The
valve should be shut tightly while starting up
the pump. After the pump discharges water
and operates normally, adjust the valve to the
required ow (ow and lift will be displayed on
the nameplate).
Attention:
1. In case no water is discharged after being started for more than 5 minutes with the water lled,
turn off the electric pump, re-ll water or check whether the inlet pipeline has leakages.
2. In case of any frost and ice damages, please open the drain plug to empty water in the pump
chamber. When start up the pump again, open the drain plug, ll water and tighten it and then
the pump is usable.
3. In case not use for a long time, water in the pump should be emptied. The pump body, impeller
and support should be cleaned and coated with anticorrosive oil before they are put in a
ventilated and dry place for use.
4. In case the pump is halted for a long time, start it up again according to above diagram.
5. In summer or when the ambient temperature is high, pay attention to ventilation, avoid dew on
electrical parts which will result in electrical faults.
6. In case the motor is hot or abnormal, cut off the power immediately and check faults according to
the following table.
- 12 -
11. Troubleshooting
Check the pump after power cut-off.
WARNING
!
OWNER’S MANUAL
- 13 -

This manual suits for next models

1

Other Stanley Water Pump manuals

Stanley SCE520 Operation instructions

Stanley

Stanley SCE520 Operation instructions

Stanley SXGP900XFE User manual

Stanley

Stanley SXGP900XFE User manual

Stanley SM21 User manual

Stanley

Stanley SM21 User manual

Stanley SXGP900XFBE User manual

Stanley

Stanley SXGP900XFBE User manual

Stanley ST4WPLT-(CA) User manual

Stanley

Stanley ST4WPLT-(CA) User manual

Stanley BXUP250PCE User manual

Stanley

Stanley BXUP250PCE User manual

Stanley tp03 User manual

Stanley

Stanley tp03 User manual

Stanley SM50 User manual

Stanley

Stanley SM50 User manual

Stanley STAPB40 User manual

Stanley

Stanley STAPB40 User manual

Stanley SXUP1000XWE User manual

Stanley

Stanley SXUP1000XWE User manual

Stanley tp03 User manual

Stanley

Stanley tp03 User manual

Stanley TP0813X User manual

Stanley

Stanley TP0813X User manual

Stanley SXUP400PCE User manual

Stanley

Stanley SXUP400PCE User manual

Stanley TP08 User manual

Stanley

Stanley TP08 User manual

Stanley Enerpac PRO Series User manual

Stanley

Stanley Enerpac PRO Series User manual

Stanley SM20 User manual

Stanley

Stanley SM20 User manual

Popular Water Pump manuals by other brands

Whale UF2025 Installation & user's instructions

Whale

Whale UF2025 Installation & user's instructions

Amsino AMSure user manual

Amsino

Amsino AMSure user manual

Lutz B50 Translation of the original instructions

Lutz

Lutz B50 Translation of the original instructions

VERDER HI-CLEAN VA-2H25 Repair parts list

VERDER

VERDER HI-CLEAN VA-2H25 Repair parts list

PSG Wilden P220 Series Engineering, operation & maintenance

PSG

PSG Wilden P220 Series Engineering, operation & maintenance

Husqvarna WT 10MP Operator's manual

Husqvarna

Husqvarna WT 10MP Operator's manual

ProMinent Sigma2 S2Cb operating instructions

ProMinent

ProMinent Sigma2 S2Cb operating instructions

MATALA WATER TECHNOLOGY G-1900 Instruction and maintenance manual

MATALA WATER TECHNOLOGY

MATALA WATER TECHNOLOGY G-1900 Instruction and maintenance manual

TOOLCRAFT TO-7159158 operating instructions

TOOLCRAFT

TOOLCRAFT TO-7159158 operating instructions

Gardner Denver Oberdorfer Pumps 406M-04 Installation, operation and maintenance instructions

Gardner Denver

Gardner Denver Oberdorfer Pumps 406M-04 Installation, operation and maintenance instructions

Ingersoll-Rand ARO 613201-3-C Operator's manual

Ingersoll-Rand

Ingersoll-Rand ARO 613201-3-C Operator's manual

Hi-Force HPX2800 operating instructions

Hi-Force

Hi-Force HPX2800 operating instructions

ITT Goulds Pumps AF 42 LM Installation, operation and maintenance manual

ITT

ITT Goulds Pumps AF 42 LM Installation, operation and maintenance manual

Golander pump FG600S Operation manual

Golander pump

Golander pump FG600S Operation manual

Rothenberger TP25 Instructions for use

Rothenberger

Rothenberger TP25 Instructions for use

Seachem Impulse 400 owner's manual

Seachem

Seachem Impulse 400 owner's manual

PYD Electrobombas PH Series user manual

PYD Electrobombas

PYD Electrobombas PH Series user manual

Walrus TPH50T5KF instruction manual

Walrus

Walrus TPH50T5KF instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.