FILLER GIRT CONNECTIONS
Figure 3
1. Roller Door Columns
Attach the filler girt to the side roller door column using a
girt bracket and two plain 10x16mm self tapping screws
in each flange.
2. End Portal Frame Column
Where the filler girt stops short of the end portal frame
column, use a girt connector bracket and two 12x30mm
flanged purlin bolts to secure the end.
3. Joining Three and Six Metre Filler Girts
Use a girt connector bracket to join filler girts at a portal frame column. Use a 12x30mm
flanged purlin bolt in each hole of the bracket. This application occurs when roller doors
are installed in the end bays of 12m long sheds. These connections should only occur at
centre portal columns.
4. Where a Girt Crosses a Portal Frame Column
In applications where the girt crosses a portal frame column, use a 12x30mm flanged
purlin bolt to secure it.
Step Three
Slide the 300mm length Superdek®
sheets into the header flashing and
fix through to the header beam and
top girt using coloured 10x16mm
self tapping screws in every pan.
INSTALL THE SHEETS
2
1