Sub-Zero Wolf Outdoor Pro Wall Hood User manual

Page 2
SERVICE MANUAL INTRODUCTION
This service manual helps with troubleshooting and diagnosing
malfunctions, completion of repairs, and return of the product to
proper operating condition. Read the complete instructions
contained within before initiating any repairs.
This guide is intended for use by Factory Certified Service. Wolf
Appliance, Inc. recommends that only Factory Certified Service
companies do repairs.
Warning and Caution product safety labels appear throughout
this manual. Product safety labels appear at the beginning of
some sections. Follow the instructions in the product safety
labels to avoid personal injury and/or product damage. The
sample safety labels explain the types of notices that appear in
this manual.
WARNING
States a hazard that may cause serious injury or
death if precautions are not followed.
CAUTION
Indicates minor injury or product damage may occur
if precautions are not followed.
IMPORTANT NOTE: Highlights especially important information.
TIP: Indicates additional, useful information.
Information and images contained herein are copyright of Wolf
Appliance, Inc. Neither this manual nor any information or
images contained herein may be copied or used in whole or in
part without the express written consent of Wolf Appliance, Inc.
©Wolf Appliance, Inc., all rights reserved.
WOLF PRODUCT RATING PLATE INFORMATION
On Pro Wall Hoods the rating plate is located on the left hand
wall.
Important information for each product is listed on the product
rating plate. Rating plates identify:
▪Model
▪Serial number
▪Electrical information
MODEL DESCRIPTIONS AND SALES ACCESSORIES
For more details on individual model descriptions and a listing
of all compatible sales accessories, see the
Wolf Distributor
Price List
.
PROFESSIONAL VENTILATION MODEL KEY
Model Character Description
ICB International Designation
P Professional Ventilation
W Model Type Wall
I Model Type Island
L Model Type Liner
WC Model Type Wall Chimney
24, 30, 36, 40, 42, 46, 48, 52,
54, 58, 60, or 66 Width (in inches)
19, 22, 24, 27, 33, or 34 Depth (in inches)
10, 12, or 18 Height (in inches)
O Outdoor
PRODUCT USE AND CARE AND INSTALLATION GUIDES
Product use and care guides, installation guides, and other
product specifications are available in the
Product
Specifications and Manuals Library
.
Pro Outdoor Hoods
General Information
GENERAL INFORMATION
service.subzero.com
828743 REVA 02/2019 1

Page 3
UNIT WARRANTY
Product warranty is determined by the installation location and
the date of installation.
▪View product warranties at
http://service.subzero.com/
ClaimsAndOrderProcessing/Pages/WarrantyInfo
.
▪Warranties start on the day of product installation.
▪Search for warranty and service information by serial
number, customer last name, and address using Unit
History at
http://service.subzero.com/Tools/UnitHistory
.
Pro Outdoor Hoods
General Information
service.subzero.com
828743 REVA 02/2019 2

Page 4
FILTER ASSEMBLY REMOVAL
Remove the Filter Assembly
1Hold the filter assembly by the knobs, and push the filter
assembly toward the top of the hood.
2Pull the bottom of the filter assembly toward the center of
the hood.
3Pull the filter assembly down.
4Remove the filter assembly from the unit.
FILTER ASSEMBLY INSTALLATION
Install the Filter Assembly
1Place the filter assembly into the channel at the top of the
hood.
2Push the filter assembly up.
3Push the bottom of the filter assembly toward the lower
channel of the hood.
4With the filter assembly over the lower channel, lower the
filter assembly down into the grease cup.
HALOGEN LAMP REMOVAL
Remove the Halogen Lamp
1Rotate the halogen lamp counterclockwise.
2Remove the halogen lamp from the unit.
HALOGEN LAMP INSTALLATION
Install the Halogen Lamp
1Place the pins of the halogen lamp into the larger holes in
the lamp socket.
2Rotate the halogen lamp clockwise.
LAMP SOCKET REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the lamp socket, first remove:
1
Halogen lamp
Remove the Lamp Socket
1Use a small Phillips screwdriver to remove the screws from
inside the lamp socket.
2Pull the lamp socket down and disconnect the lamp socket
wire harness.
Pro Outdoor Hoods
Component Removal and Installation
COMPONENT REMOVAL AND INSTALLATION
service.subzero.com
828743 REVA 02/2019 3

Page 5
3Remove the lamp socket from the unit.
LAMP SOCKET INSTALLATION
After installing the lamp socket, install:
1
Halogen lamp
Install the Lamp Socket
1Connect the lamp socket wire harness.
2Insert the lamp socket wire harness into the hood and place
the lamp socket into lamp frame.
3Use a small Phillips screwdriver to install the screws into the
lamp socket.
BLOWER KNOB REMOVAL
Remove the Blower Knob
1Use a 1/16" Allen wrench to loosen the set screw in the
blower knob.
2Remove the blower knob from the blower switch shaft.
BLOWER KNOB INSTALLATION
Install the Blower Knob
1Place the blower knob onto the blower switch shaft.
2Use a 1/16" Allen wrench to tighten the set screw in the
blower knob.
FILTER SPRING REMOVAL
To remove the filter spring, first remove:
1
Filter assembly
Remove the Filter Spring
1Compress the filter spring, and pull one end of the filter
spring from the opening.
2Remove the other side of the filter spring from the opening.
3Remove the filter spring from the unit.
FILTER SPRING INSTALLATION
After installing the filer spring, install:
1
Filter assembly
Install the Filter Spring
1Place one end of the filter spring into the opening.
2Compress the filter spring and push the other end of the
filter spring into the opening.
Pro Outdoor Hoods
Component Removal and Installation
REMOVE THE LAMP SOCKET (continued)
service.subzero.com
828743 REVA 02/2019 4

Page 6
GREASE CUP REMOVAL
To remove the grease cup, first remove:
1
Filter assembly
Remove the Grease Cup
1Lift the grease cup from the lower channel of the hood.
2Remove the grease cup from the unit.
GREASE CUP INSTALLATION
After installing the grease cup, install:
1
Filter assembly
Install the Grease Cup
TIP: The long side of the L-shaped grease cup sits on the
bottom of the hood channel.
1Place the grease cup into the lower channel of the hood.
2Push the grease cup back into the channel until it stops.
WIRE COVER REMOVAL
To remove the wire cover, first remove:
1
Filter assembly
Remove the Wire Cover
1Use a Phillips screwdriver to remove the screw from the
wire cover.
2Remove the wire cover from the unit.
WIRE COVER INSTALLATION
After installing the wire cover, install:
1
Filter assembly
Install the Wire Cover
1Place the wire cover into the hood.
2Use a Phillips screwdriver to install the screw into the wire
cover.
BLOWER MOUNTING PLATE REMOVAL
To remove the blower mounting plate, first remove:
1
Filter assembly
Remove the Blower Mounting Plate
1If an internal blower is installed in the hood, remove the
internal blower from the unit.
2Use a socket to remove the nuts from the blower mounting
plate.
Pro Outdoor Hoods
Component Removal and Installation
service.subzero.com
828743 REVA 02/2019 5

Page 7
3Remove the blower mounting plate from the unit.
BLOWER MOUNTING PLATE INSTALLATION
After installing the blower mounting plate, install:
1
Filter assembly
Install the Blower Mounting Plate
1Place the blower mounting plate into the hood.
2Use a socket to install the nuts onto the blower mounting
plate.
3If an internal blower was removed from the hood, install the
internal blower.
INTERNAL FRAME REMOVAL
To remove the internal frame, first remove:
1
Filter assembly
2
Grease cup
Remove the Internal Frame
1Use a Phillips screwdriver to remove the screws from the
front of the internal frame.
2Pull the front of the internal frame down five inches.
3Pull the internal frame forward off of the rear tabs.
4Remove the internal frame from the unit.
INTERNAL FRAME INSTALLATION
After installing the internal frame, install:
1
Grease cup
2
Filter assembly
Install the Internal Frame
1Install the rear of the internal frame over the tabs in the
hood.
2Lift the front of the internal frame into place on the hood.
3Use a Phillips screwdriver to install the screws into the
internal frame.
INNER PANEL REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the inner panel, first remove:
1
Filter assembly
2
Grease cup
3
Internal frame
Remove the Inner Panel
1Use a Phillips screwdriver to remove the screws from the
inner panel.
2Move the lower edge of the inner panel forward.
3Pull the top of the inner panel past the support frame.
Pro Outdoor Hoods
Component Removal and Installation
REMOVE THE BLOWER MOUNTING PLATE (continued)
service.subzero.com
828743 REVA 02/2019 6

Page 8
4Lower the inner panel, and disconnect the blower and light
switch wire connectors.
5Disconnect the wire connector from the blower speed
control.
6Disconnect the wire connectors from the lamp sockets.
7Disconnect the wire connectors from the heat sensor.
8Disconnect the wire harness from the blower plug socket.
9Remove the wire harness from the wire retainer.
10 Rotate one side of the inner panel past the side of the hood.
11 Remove the inner panel from the unit.
INNER PANEL INSTALLATION
After installing the inner panel, install:
1
Internal frame
2
Grease cup
3
Filter assembly
Install the Inner Panel
1Raise the inner panel into the hood with one side of the
inner panel lower than the other.
2Rotate the lower side of the inner panel into the hood.
3Install the wire harness into the wire retainer.
4Connect the wire harness to the blower plug socket.
5Connect the wire connectors to the heat sensor.
6Connect the wire connectors to the lamp sockets.
7Connect the wire connector to the blower speed control.
8Connect the blower and light switch wire connectors. Raise
the inner panel.
9Place the top of the inner panel behind the support frame.
Insert the tabs into the holes.
10 Use a Phillips screwdriver to install the screws into the inner
panel.
HEAT SENSOR REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the heat sensor, first remove:
1
Filter assembly
2
Grease cup
3
Internal frame
4
Inner panel
Remove the Heat Sensor
1Use a Phillips screwdriver to remove the heat sensor
mounting screws.
2Remove the heat sensor from the unit.
HEAT SENSOR INSTALLATION
After installing the heat sensor, install:
1
Inner panel
2
Internal frame
3
Grease cup
4
Filter assembly
Install the Heat Sensor
1Place the heat sensor onto the inner panel.
2Use a Phillips screwdriver to install the heat sensor
mounting screws.
Pro Outdoor Hoods
Component Removal and Installation
REMOVE THE INNER PANEL (continued)
service.subzero.com
828743 REVA 02/2019 7

Page 9
BLOWER PLUG SOCKET REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the blower plug socket, first remove:
1
Filter assembly
2
Grease cup
3
Internal frame
4
Inner panel
Remove the Blower Plug Socket
1Use a 5/16" socket to remove the blower plug socket ground
screw.
2Press in the tabs on the side of the blower plug socket.
Push the blower plug socket through the inner panel.
3Remove the blower plug socket from the unit.
BLOWER PLUG SOCKET INSTALLATION
After installing the blower plug socket, install:
1
Inner panel
2
Internal frame
3
Grease cup
4
Filter assembly
Install the Blower Plug Socket
1Insert the blower plug socket into the inner panel.
2Use a 5/16" socket to install the blower plug socket ground
screw.
BLOWER SWITCH REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the blower switch, first remove:
1
Filter assembly
2
Grease cup
3
Internal frame
4
Inner panel
Remove the Blower Switch
IMPORTANT NOTE: Removing the blower switch usually
damages the switch tabs. Do not remove the blower switch
without a replacement available.
1Disconnect the wire connector from the blower speed
control.
2Use a wide pair of pliers to compress the tabs on the back
of the blower switch.
3Push the blower switch down out of the hood.
4Remove the blower switch from the unit.
BLOWER SWITCH INSTALLATION
After installing the blower switch, install:
1
Inner panel
2
Internal frame
3
Grease cup
4
Filter assembly
Install the Blower Switch
1Insert the blower switch into the hood.
Pro Outdoor Hoods
Component Removal and Installation
service.subzero.com
828743 REVA 02/2019 8

Page 10
2Connect the wire from the blower speed control to the
blower switch.
LIGHT SWITCH REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the light switch, first remove:
1
Filter assembly
2
Grease cup
3
Internal frame
4
Inner panel
Remove the Light Switch
IMPORTANT NOTE: Removing the light switch usually
damages the switch tabs. Do not remove the light switch
without a replacement available.
1Use a wide pair of pliers to compress the tabs on the back
of the light switch.
2Push the light switch down out of the hood.
3Remove the light switch from the unit.
LIGHT SWITCH INSTALLATION
After installing the light switch, install:
1
Inner panel
2
Internal frame
3
Grease cup
4
Filter assembly
Install the Light Switch
Insert the light switch into the hood.
BLOWER SPEED CONTROL REMOVAL
WARNING
Turn off the power to the product before starting this
procedure.
To remove the blower speed control, first remove:
1
Filter assembly
2
Grease cup
3
Internal frame
4
Inner panel
Remove the Blower Speed Control
1Disconnect the wire connector from the blower switch.
2Use 1/2" socket to remove the nut from the blower speed
control shaft.
3Push the blower speed control up into the hood.
4Remove the blower speed control from the unit.
BLOWER SPEED CONTROL INSTALLATION
After installing the blower speed control, install:
1
Inner panel
2
Internal frame
3
Grease cup
4
Filter assembly
Install the Blower Speed Control
1Insert the blower speed control into the hood.
Pro Outdoor Hoods
Component Removal and Installation
INSTALL THE BLOWER SWITCH (continued)
service.subzero.com
828743 REVA 02/2019 9

Page 11
2Use a 1/2" socket to install the nut onto the blower speed
control shaft.
3Connect the wire connector from the blower switch to the
blower speed control.
10" TRANSITION REMOVAL
To remove the 10" transition, access to the top of the hood is
required. This might be from a space above the hood, or the
hood may need to be uninstalled.
Remove the 10" Transition
1Use a Phillips screwdriver to remove the screws from the
damper brackets.
2Remove the damper brackets from the unit.
3Remove the 10" transition from the unit.
10" TRANSITION INSTALLATION
Install the 10" Transition
1Place the 10" transition onto the top of the hood.
2Place the damper brackets onto the 10" transition.
3Use a Phillips screwdriver to install the screws into the
damper brackets.
Pro Outdoor Hoods
Component Removal and Installation
INSTALL THE BLOWER SPEED CONTROL (continued)
service.subzero.com
828743 REVA 02/2019 10

Page 12
TROUBLESHOOTING GUIDE PRO WALL HOOD
This section explains how to troubleshoot various components
in a Wolf Pro Wall Hood.
WARNING
To avoid electric shock, disconnect power to the
hood when preparing for tests. Care should be used
while doing any test with the hood energized.
WARNING
The hood is heavy and is lowered from the
installation when being uninstalled.
Pro Outdoor Hoods
Troubleshooting Guide Pro Wall Hood
service.subzero.com
828743 REVA 02/2019 11

Page 13
PRO WALL HOOD TROUBLESHOOTING TABLE
Symptom Possible Cause or Diagnostic Test Resolution
Hood lights and blower do
not turn on.
The breaker is open. Reset the breaker.
GFCI circuit is tripped. The unit should not be installed on a GFCI circuit.
Change the outlet type.
Verify the house circuit is dedicated, the correct
voltage, and sized correctly.
If necessary, contact an electrician to bring the circuit
into specification.
Confirm that the L1, N, and ground are correctly
connected. Make sure the connections are tight.
Blower motor runs only at
high speed.
Heat sensor closed. Confirm heat sensor is closed.
Blower speed control. Check for voltage changes out of the blower speed
control.
Hood lights do not work. Test the operation of the halogen lamp. If only one halogen lamp is out, replace the halogen
lamp.
Disconnect the wire connectors from the light switch
and measure the resistance.
If no continuity in either the on or off position, replace
the light switch.
Disconnect the electrical supply wire to the light
switch and check for the correct voltage.
If no voltage, trace the wire to the issue and repair the
wire.
Blower motor does not
run at any speed.
Internal blowers: Check the voltage at the blower plug
socket connector while the blower is running.
Check L1 to ground, L2 to ground, and L1 to L2 for
the correct voltage.
Disconnect the wire connectors from the blower
switch and measure the resistance.
If no continuity in either the on or off position, replace
the blower switch.
Disconnect the electrical supply wire to the blower
switch and check for the correct voltage.
If no voltage, trace the wire to the issue and repair the
wire.
Test the resistance of the blower speed control. The resistance of the blower speed control should
change as the knob is turned. The resistance should
never be infinite or open.
Check the blower. Replace the blower.
Blower motor runs, but
does not change speeds
(not at high speed).
This failure can be caused by:
▪Blower speed control failure
▪Wrong voltage supplied to the hood
1Check the voltage to the hood.
2Check the voltage output of the blower speed
control by back-pinning the wire connector of the
black to orange wire connector to ground. The
voltage should change as the knob is turned.
Blower comes on by itself. Heat sensor is closing. ▪Hood installation to close to cooking equipment.
▪Cooking equipment producing too much heat.
▪Blower issue.
▪Ducting issue.
▪Heat sensor failure.
Hood does not move
enough air.
Verify the duct run is the correct size, including:
▪Wall/roof cap is correct.
▪No reduction in size at any point.
▪Damper is installed correctly.
▪No excessive elbows.
▪No excessive length.
▪No air box used.
Correct the duct issue. Recommended duct size is
10".
Blower motor is not changing speeds. See "Blower motor runs only at high speed" or
"Blower motor runs, but does not change speeds."
Filters are dirty. Remove the filters to test. Clean the filters.
Pro Outdoor Hoods
service.subzero.com
828743 REVA 02/2019 12

Page 14
TEST THE LINE VOLTAGE IN THE WIRING BOX
WARNING
Components are energized during these tests.
Use extreme caution to prevent electrical shock
or shorting out the unit.
1Disconnect the wire connectors from the home power
supply.
2Measure the voltage from the electrical supply L1 (typically
black) to ground. The voltage should be 110 VAC to 127
VAC.
3Measure the voltage from the electrical supply neutral
(typically white) to ground. The voltage should be 0 VAC.
4Measure the resistance from the electrical supply ground
(typically green) to ground. The resistance should be 0 Ω.
5Measure the voltage from the electrical supply L1 to neutral.
The voltage should be 110 VAC to 127 VAC.
TEST THE LINE VOLTAGE AT THE BLOWER PLUG SOCKET
WARNING
Components are energized during these tests.
Use extreme caution to prevent electrical shock
or shorting out the unit.
1On the blower plug socket side of the wire connector, back-
pin the black and white wires as described below, with the
blower running on high.
2Measure the voltage from the black wire to the ground. The
voltage should be 110 VAC to 127 VAC.
3Measure the voltage from the white wire to the ground. The
voltage should be 0 VAC.
4Measure the resistance between the ground to a unit
ground. The resistance should be 0 Ω.
5Measure the voltage from the black wire to the white wire.
The voltage should be 110 VAC to 127 VAC.
TEST THE INTERNAL BLOWER
Do these tests only after confirming the voltage is correct up to
the internal blower.
1Unplug the internal blower plug.
2On the blower plug, measure the resistance from pin L1 to
Neutral.
3Measure the resistance from the plug L1 to the blower
casing.
4Measure the resistance from the plug Neutral to the blower
casing.
5If the reading is open from L1 to Neutral or there is
continuity from L1 or Neutral to the blower case, replace the
blower.
Pro Outdoor Hoods
Test Procedures
TEST PROCEDURES
service.subzero.com
828743 REVA 02/2019 13

Page 15
PRO WALL HOOD TECHNICAL DATA
PRO WALL HOOD TECHNICAL DATA
Parameter Value
AC power 110 VAC to 127 VAC
Blower switch 828568 125 VAC 20 A
Light switch 828569 125 VAC 20 A
Blower speed control 828570 120 VAC 7 A (Max)
Heat sensor 828571 Opens and closes at 200°F
Pro Outdoor Hoods
Technical Data
TECHNICAL DATA
service.subzero.com
828743 REVA 02/2019 14

Page 16
OUTDOOR PRO WALL HOOD WIRING DIAGRAM
Pro Outdoor Hoods
Wiring Diagrams
WIRING DIAGRAMS
service.subzero.com
828743 REVA 02/2019 15

Page 17
Pro Outdoor Hoods
Wiring Diagrams
service.subzero.com
828743 REVA 02/2019 16
Table of contents
Popular Ventilation Hood manuals by other brands

Baumann
Baumann AURA Instructions for using, maintaining and installing

NEFF
NEFF D 96T5N0 Operating and installation instructions

Malloca
Malloca SLIM K1522 user manual

inventum
inventum AKI6015RVS user manual

Foster
Foster CILINDRO ISLAND Installation maintenance and operating instructions

Rainford
Rainford RCH6601T Plus User instructions