- 9 - SUMMIT 201805 GAS OVEN
SGWO30SS MANUAL
INSTALLATION INSTRUCTIONS
SPECIAL WARNING:
ONLY QUALIFIED AND AUTHORIZED PERSONNEL SHALL INSTALL OR SERVICE
THIS RANGE.
READ “SAFETY INSTRUCTIONS” IN THIS BOOKLET BEFORE USING RANGE.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE,
MAINTENANCE OR USE OF RANGE CAN RESULT IN SERIOUS INJURY OR
PROPERTY DAMAGE, AND SO THE MANUFACTURE WILL NOT BE RESPONSIBLE.
This appliance must be installed in accordance with the manufacturer’s installation
instructions and local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 / NFPA 54 in the U.S.A., and current CAN/CSA B149.1 Natural Gas
and Propane Installation Code.
CLEARANCE DIMENSIONS
Appliance may be installed with zero inches clearance adjacent to (against) combustible
construction at the rear and on the sides. For complete information in regard to the
installation of wall cabinets around the oven and clearances to combustible walls, see the
installation drawing fig. n° 08. For Safety Considerations, do not install unit in any
combustible cabinetry which is not in accordance with the installation drawings. The
recess in which an oven unit is installed shall be constructed so as to provide a complete
closure around the recessed portion of the appliance, and any openings around gas and
electric service outlets shall be closed at the time of installation, except when the
construction of the appliance provides the necessary closure.
CAUTION: SOME CABINETS AND BUILDING MATERIALS ARE NOT DESIGNED TO
WITHSTAND THE HEAT PRODUCED BY THE NORMAL SAFE OPERATION OF A
LISTED APPLIANCE. DISCOLORATION OR DAMAGE, SUCH AS DELAMINATION,
MAY OCCUR.
LOCATING THE OVEN, WARNING:
Do not install beneath work counters. The bottom of the cut-out section of the appliance
installation must be located not lower than 16 inches (406 mm) from the floor level, in
accordance with the manufacturer’s instructions. Make sure the flow of combustion or
ventilation air is not obstructed. (See fig. 08 on next page.)
VENTILATION
Ventilation must be in accordance with local installation code. The appliance must be
installed in a well-ventilated environment to guarantee a correct combustion gases
exchange, proper air circulation and working temperature within safety limits (see figure
08).