Sundaya Apple User manual

Forced Health Improvement (FHI®):
Frequent cycling of the battery at a very low state of charge causes
fast deterioration of the battery due to sulphation and stratification.
The Apple will not allow the User to frequently operate the battery at
low state of charge. After reaching a forced Low Voltage Disconnect
(LVD),the user will not be able to discharge the battery to the same
low level again next day.This is indicated to the user with a yellow LED
Penalty mode.Only after reaching the Boost Charge level of 14.5V the
Penalty mode will be reset and the Apple will allow the user to use the
full battery capacity again.
The Apple is available in 3 standard charge/discharge current
capacities 5, 10 and 15 Amperes. With its clean and round appearance,
and all cable connections nicely covered at the backside of the unit,
the Apple is esthetically attractive for indoor installation.
The "Apple" is a unique small PV charge/discharge controller in the
Sundaya product range,specially designed for cost-effective applications
based on SMD technology. The Apple is extremely power- efficient due to
its very low voltage drop over both input and output switching Mosfets.
Unique features include Forced Health Improvement (FHI®) algorithm,
and a buzzer to remind the User of the battery’s SOC (State of Charge) as
it gets close to LVD (Low Voltage Disconnect). Furthermore,it comes with
a self-reset electronic master-switch, so that whenever the Apple is
reconnected to the battery or simply newly installed, the output will
always stay inactive until the user presses on the reset switch. A SOC
(State of Charge) indicator gives clear indication of the battery's status.
Product Description
Main Features:
# Strong input and output connectors with clear polarity markings
# Cable connectors not reachable and not visible after mounting on the
wall (safety and esthetic reasons)
# Extremely low voltage drop over power mosfets
# Boost Charge mode
# LED Indicator for charging
# LED Indicator for state of charge in 8 steps
# Electronic Overload/Short circuit protection with LED Indicator
# Electronic Master-switch to centrally cut off all loads
# Deep discharge cut off with LED Indicator
# Forced Health Improvement (FHI®) feature
1 8-steps SOC (State of Charge) LED Indicator
To indicate the SOC of the batteries, the SOC level is proportional to the
numbers of the LEDs lit up.Example: All 8 LEDs lit up indicate the
batteries are fully charged (SOC = 12.7 - 13.1V); Only the first (lowest)
LEDs lit up indicate the batteries close to exhaustion, the output of the
controller will soon be cut if the LOAD continues to be connected
without sufficient charging to replenish the batteries (SOC = 11.4 -
11.7V).
2. Deep discharge Cut-Off LED Indicator
To indicate that the controller disconnected the output due to SOC
falling below 11.9 V +/- 0.10 V on Penalty mode, or 11.5V +/- 0.10 V on
Non Penalty mode.
3. Display Button
The 8-steps SOC (State of Charge) LED Indicator, Deep discharge Cut-Off
LED Indicator, Master-switch / Overload/Short circuit LED Indicator, and
Penalty mode LED Indicator will display the status only when the Display
Button pressed.
4. On/Off Master-Switch
Toggle the controller output from on to off, or off to on by pressing the
switch once.
5. Master-switch / Overload/Short circuit LED Indicator
The LED Indicator will light up when the User turns off the output by
pressing the On/Off Master-Switch once,or the controller cuts off the
output due to a short circuit detected.
6. Penalty mode LED Indicator
The LED Indicator will light up when the Penalty mode is in effect, due to:
- During controller’s first power up, the SOC of the battery is below 12.7V
- After the controller disconnected the output due to SOC falling below
11.9 V +/- 0.10 V on Penalty mode,or 11.5V +/- 0.10 V on Non Penalty
mode.
7. Charging LED Indicator
The LED Indicator will light up when charging take place.
LED Indicators and Button/Switch Description:
11
1
2
3
5
6
7
4
#Sundaya
Battery Terminal
Connector
Load Terminal
Connector
PV Terminal
Connector
#Sundaya
#Sundaya
6. Press the On/Off Master-Switch, and hold for one or two seconds, then
release. The Load will turn on.
7. Connect the Solar Panel Input to either 12Vdc Solar modular or 12Vdc
charger such as DC10. (Caution: - please make sure the positive and
negative polarities are correctly connected)
8. The Charging LED Indicator should light up if charging is taking place.
9. Mount the controller in indoor environment with minimum exposure
to rainwater, water spill or hot temperature such as cooking oven.
10. The surface to mount the controller should be of good isolated
material such as brick wall, plastic, or wood.
Installation procedure:
1. Unpack the controller.
2. Prepare a fully charged battery.
3. Connect the controller to the fully charged battery. (Caution: - please
make sure the polarities are correctly connected)
4. Press on the Display Button. All the 8-steps SOC (State of Charge) LED
Indicator should light up if the battery is fully charged.
5. Connect the controller output to the load.Ideally, use low power load
first such as DC lighting product (Ulite3), to verify proper operation.
(Caution: - please make sure the positive and negative polarities are
correctly connected)
#Sundaya
Apple
User's Manual
#Sundaya
Sundaya Contact Information
Sundaya International Pte.,Ltd.
Address: II Tampines street 92
SINGAPORE 528872
E-mail: [email protected]m
Web Site: www.sundaya.com
Telephone: +65 6788 8345
Facsimile: +65 6788 8749
Sundaya Indonesia,PT.
Address: Jl. Pondok Randu No.38
Cengkareng, Jakarta Barat
INDONESIA 11750
Telephone: +62 21 541 6103-05
Facsimile: +62 21 541 6106
Stage-1: - When the Controller is first connected to a half charged
battery (SOC < 12.7V).
Penalty mode LED Indicator - on
Load cut-off
Stage-2: - After the battery is charged up to SOC > 12.7V.
Load indicator on
Stage-3: - After the battery fully charged (SOC > 14.5V)
Penalty mode LED Indicator - off
Controller entry to PWM mode to prevent the battery being
over charged
The Charging LED indicator will start to blink
Stage-4: - The battery discharged to SOC < 11.7V.
Warning buzzer on
Stage-5: - The battery continues discharge to SOC < 11.5V.
Deep discharge Cut-Off LED Indicator on
Penalty mode LED Indicator on
Load cut-off
Stage-6: - The battery recharged back to SOC > 12.7V
Deep discharge Cut-Off LED Indicator off
Load indicator on
Stage-7: - Under the Penalty mode, the battery discharged to SOC <
12.1V.
Warning buzzer on
Stage-8: - Under the Penalty mode, the battery continues to be
discharged to SOC < 11.9V Load cut-off
Stage-9: - The battery charged back to SOC > 12.7V
Load indicator on
After the battery fully charge (SOC > 14.5V)
Penalty mode LED Indicator - off
Controller entry PWM mode to prevent over charge
Safety:
# User should ensure the surface for mounting the controller is
sufficiently strong to carry the weight of the unit.
# Short circuit of batteries could generate excessive heat and possibly
melt down the cables, causing injury to the User.During installation or
battery replacement it is advisable to connect and secure the battery
cable to the controller first,before connecting to the terminals on the
battery.
Warranty:
All Sundaya Controller are warranted for any defects caused by faulty
components or factory error.Warranty period varies depending on the
country.Please check with your local dealer for details.
The warranty will be void under the following conditions:
-The Product shows signs of having been exposed to water spill or
submerged in liquid.
-The Product shows signs of being opened, or warranty seal is broken.
-The Product shows signs of abuse or misuse.
Mechanical Specification:
Enclosure Materials : ABS
Color : Green
Shape : Round
Size : 120mm x 40mm
Terminals :
# 8mm width Input terminal for Battery (bottom side)
# 8mm width Input terminal for Solar Panel (top side)
# 8mm width Output terminal for Load (top side)
Operation:
Load Connect Area
Buzzer Warning
Penalty Area
Remarks :
Voltage
Load
Penalty
STAGE - 1 STAGE - 2 STAGE - 3 STAGE - 4 STAGE - 5 STAGE - 6 STAGE - 7 STAGE - 8 STAGE - 9
11
12
13
14
15
Load Reconnect
Level
Penalty Mode
Disconnect level
Load Disconnect
Level
Penalty
Boost
Buzzer
Buzzer
Discharge
Charge
Load Reconnect
Penalty
Load Connect
Penalty Load
Load Reconnect
Load Disconnect
& Penalty ON
PWM Float Charge
Electrical Specification:
Nominal operating Voltage : 12VDC
Self consumption : 4 mA
Current Model Apple 5 : 5 Amp -0% +25%
Current Model Apple 10 : 10 Amp -0% +25%
Current Model Apple 15 : 15 Amp -0% +25%
Low Voltage Buzzer Warning Level : 11.70 V (Non-Penalty mode)
Low Voltage disconnect : 11.50 V +/- 0.10 V (Non- Penalty mode)
(Non-Penalty mode) (with discharge current
compensation -0.04V/A)
Low Voltage Buzzer Warning Level : 12.10 V (Penalty mode)
Low Voltage disconnect : 11.90V +/- 0.10V (Penalty mode)
(Penalty mode) (with discharge current
compensation -0.04V/A)
Load Reconnect level : 12.70 V
Penalty mode reset : 14.50V +/- 0.10V
Boost Charge Level @250c : 14.5V (with Temperature
compensation -0.02V/deg C)
PWM float Charge level : 14.10V (with Temperature
compensation -0.02V/ deg C)
Warning:
# Do not connect the controller to AC power.
# Although all controllers are reverse polarity protected,User should
ensure correct connection by respecting the polerities.
# All controllers are designed for indoor uses only.
# All solar panel or charger connected to the controller should be
dedicated to 12Vdc applications,and the current suplied to the controller
should be equal to or smaller than the controller's output current. For
example: -
Apple-5 - The maximum current input from solar panel or charger
should NOT excess 5A.
Apple-10 - The maximum current input from solar panel or charger
should NOT excess 10A.
Apple-15 - The maximum current input from solar panel or charger
should NOT excess 15A.

Sundaya Apple Regulator
Quick Start Manual
The Apple charge controller is ideal for people living in remote locations where battery protection from excessive discharges is of
paramount importance and the cost of battery replacement is very high. To achieve this level of battery protection the loads are
connected directly to the Apple charge controller to allow it to turn off your loads when the battery voltage becomes critically low,
thus protecting the battery from excessive discharge. You may choose not to use this feature and connect your loads through
appropriate fuses or circuit breakers to your battery and not use the Apple load connection. This may be the case if:
•you aren’t concerned about your battery replacement cost
•your loads exceed the 5, 10 or 20 amp rating of the apple
load controller; and/or
•you have a back-up generator
Main Features:
•8mm input and output connectors with clear polarity
markings
•Extremely low voltage drop over power Mosfets for high
efficiency
•Boost Charge mode
•Electronic Overload/Short circuit protection with LED
Indicator
•Electronic Master-switch to centrally cut off all loads
•LED voltage indicators for charging and low voltage
disconnect
•Low voltage alarm
•PWM charging with temperature compensation
LED Indicators and Button/Switch Description:
•8-steps Battery Voltage LED: The Battery Voltage level is proportional to the number of the LEDs lit up. State of charge can
roughly be equated to voltage when the batteries are at rest (no current flow in or out). All 8 LEDs lit up indicate the batteries are
fully charged (Voltage = 12.7 –13.1 V); Only the first (lowest) LEDs lit up indicate the batteries are almost totally discharged and
that the output of the controller will soon be cut if the LOAD continues to be connected without sufficient charging to replenish the
batteries (Voltage = 11.4 – 11.7V).
•Deep discharge Cut-Off LED: Indicates that the controller disconnected the load output due to battery voltage falling below 11.6
V ± 0.10 V on Penalty mode 11.5V ± 0.10 V on Non Penalty mode.
•Display Button: The LEDs will display the status only when the Display Button is pressed.
•On/Off Master Switch: Toggle the controller output from on to off, or off to on by pressing the switch once.
•Master-switch / Overload/Short circuit LED: This LED will light up when the User turns off the output by pressing the On/Off
Master-Switch once, or the controller cuts off the output due to a short circuit detected.
•Charging LED: This LED will light up when charging is taking place.
Installation procedure:
a)Connect the controller to the fully charged battery. (Caution:- please make sure the polarity is correct)
b)Press on the Display Button. All 8 Battery Voltage LEDs should light up if the battery is fully charged.
c) Connect the controller output to the load. Ideally, use low power load first such as a DC lighting product (Ulite3), to verify proper
operation. (Caution:- please make sure the polarity is correct, that positive and negative connections are correctly done).
d)Press the On/Off Master-Switch, and hold for one or two seconds, then release. The Load will turn on.
e)Connect the Solar Panel Input to either 12Vdc Solar modules or 12Vdc charger such as DC10. (Caution:- please make sure the
positive and negative polarity is correctly connected)
f) The Charging LED should light up if charging is taking place.
g)Mount the controller in indoor environment with minimum exposure to rain, moisture or high temperatures such as near the sink
or the stove.
h)The surface to mount the controller on should be of good insulated material such as brick, plastic, or wood.
i) When the Controller is first connected to a half charged battery (Voltage < 12.7V), then the load terminal may be disconnected
until the voltage rises above 12.7 volts and the on/off button is pushed. From then on the load terminal will switch off below 11.6
volts.
Safety:
Short circuit of batteries could generate excessive heat and possibly melt down the cables, causing injury to the User. At least one
(either the positive or the negative) battery lead should be protected by an appropriate HRC fuse. For the leads supplied with the
5A model we recommend using a fuse rated at 20 amps or less. For the 20A model we suggest you use at least 7.9 mm² battery
leads protected by an HRC fuse rated at 45 amps or less. During installation or battery replacement it is advisable to connect and
secure the battery cable to the controller first, before connecting to the terminals on the battery.

19.08.13
Warning:
•Although the Apple controllers are reverse polarity protected, the user should ensure correct connection by ensuring all polarity
specific connections are done correctly (positive to positive, negative to negative).
•The Apple controllers are designed for indoor use only.
•All solar panels connected to the controller should be 12Vdc, and the current supplied to the controller should be equal to or
smaller than the controller's output current.
Warranty:
All Sundaya Controllers are warranted for 2 years for any defects caused by faulty components or factory error. The warranty will
be void under the following conditions:
•The Product shows signs of having been exposed to moisture or submerged in liquid.
•The Product shows signs of being opened, or
warranty seal is broken.
•The Product shows signs of abuse or misuse.
Mechanical Specification:
Enclosure Material : ABS Plastic
Colour : Green
Shape : Round
Size : 120mmØ x 40mm
Terminals : 8mm
Electrical Specification:
Nominal operating Voltage: 12VDC
Self consumption: 4 mA
Current Model Apple 5: 5 Amp -0% +25%
Current Model Apple 10: 10 Amp -0% +25%
Current Model Apple 20: 20 Amp -0% +25%
Low Voltage Buzzer Warning Level: 11.70 V
Low Voltage disconnect: 11.50V ± 0.10V (with discharge current compensation -0.04V/A)
Load Reconnect level: 12.6V
Boost Charge Level @25/C: 14.5V (with Temperature compensation -0.02V/°C)
PWM float Charge level: 14.10V (with Temperature compensation -0.02V/°C)
Fault finding
If you are using the load terminal and the loads won't turn on:
1)When you first connect the Apple regulator to a battery, the load terminal is turned off. The load terminal is turned on by pressing
the on/off button. You can check whether the loads are on or off by holding the display button on for about 10 seconds (the on/off
light will blink every five seconds indicating the loads are off... if no light blinks, the loads are on).
2)If the cut-off light comes on and stays on, the batteries are very flat and have therefore been disconnected from the loads to
prevent damaging excessive discharge. The loads will come back on automatically when the battery has been charged back up
to safe level.
3)If there is a wiring fault (short circuit), the on/off light will come on and stay on. The loads can only be reconnected when the
wiring problem has been fixed and the on/off button has been pressed to `reset' the load terminal.
4)Check the polarity (positive and negative) of all your loads; some loads will only run if they are correctly wired. Although they will
not be damaged, no Sundaya florescent lights work if the wiring is the wrong way round.
The solar panel won't charge the battery (charge light won't come on):
i. Make sure the solar panel is wired correctly (positive and negative are correct).
ii. NOTE: the solar panel cannot be switched on or off using the on/off switch- it is always connected to the battery and will always
charge if there is sunlight on the panel.

1
Sundaya Apple Laderegulator
Bruger manual
Laderegulatoren Apple er ideel til brug sammen med solceller som oplader 12V batterier. Laderegulatoren
beskytter mod afladning, som sikrer et længere levetid på batteriet. For at sikre denne beskyttelses niveau
for batteriet skal forbruget( lamper, radio, osv. ) tilsluttes direkte til Apple laderegulatoren. Det giver mulighed
til at lukke for forbruget nå batteri niveauet er for lavt. I følgende tilfalder skal forbruget tilsluttes direkte til
batteriet igennem en sikring eller afbryder:
- hvis forbruget overstiger 5,10 eller 15 A i forhold til Apple modellen
- hvis man har en backup generator
Egenskaber
- 8mm indgang og udgangs tilslutninger med klar markeret polaritet
- Meget lav ltab i transistor reguleringen som sikrer en høj effektivitet
- Boost opladnings måde
- Elektronisk overopladning/kortslutnings beskyttelse med LED indikator
- Elektronisk ON/OFF knap for at tænde og slukke for forbrug
- LED indikator for opladning og lav spænding
- Lav spænding alarm
- PWM opladning med temperatur kompensation
LED Indikator knap beskrivelse:
1. 8-lysdioder visning af batteriets spænding:
Batteriets spænding er direkte proportional med antallet af LED som lyser. Opladnings status kan
oversættes i volt nå der er ingen forbrug fra batteriet. Hvis alle 8 LED lyser, vises at batteriet er fuld ladet op
(Spænding = 12.7 – 13.1 V); Hvis kun den nederste LED lyser, er batteriet total afladt og udgangen til
forbrug vil blive snart afbrudt, hvis der bruges mere strøm og spændingen falder under 11,4V Forbruget
bliver tilsluttet igen hvis spændingen stiger over 12,6V.
2. Dybde afladnings LED:
Viser at laderegulatoren har afbrudt forbruget fra batteriet.
3. Display knap:
Lysdioderne vil vise status kun hvis man trykker på Display knappen.
4. On/Off Master Switch:
Tænder og slukker udgangen til forbrug ved tryk på knappen.
5. Master-switch / overopladning/kortslutnings LED:
Denne lysdiode vil lyse nå brugeren vil slukke for forbrug ved at trykke på Tænd/sluk knappen eller hvis
laderegulatoren selv afbryder udgangs strømmen på grund af en kortslutning.
6. Opladnings LED:
Denne lysdiode vil lyse når der bliver ladet op fra solcellen.
Installations procedure:
1. Tilslut laderegulatoren til en fuld opladet batteri - kontroller at polariteten er rigtigt – se tegningen
2. Tryk på Display knappen. Alle 8 LEDs skal lyse hvis batteriet er fuld opladet.
3. Tilslut laderegulatorens udgang til forbrug (brug først lav forbrug komponenter som en lampe eller en lille
transistor radio) for at kontrolere at det virker (Kontroller gerne at polariteten er rigtig!!!)
4. Tryk knappen On/Off Master-Switch, og hold den nede for 1-2 sekunder og slip knappen bagefter.
Lampen eller radio vil tænde.
5. Tilslut solcellepanellet til indgangen – hvor der stå PV bag laderegulatoren. (Kontroller gerne at polariteten
er rigtig!)
6. Opladningslysdioden vil lyse hvis solpanellet levere strøm og batteriet bliver opladet.
7. Monter laderegulatoren indendørs med et minimum udsættelse for regn, støv, eller høj temperatur.
8. Overfladen hvor laderegulatoren monteres på, skal være isolerende – af træ eller hård plastik
9. Hvis laderegulatoren tilsluttes til en halv opladet batteri udgangen til forbrug bliver slukket (Spændingen <
12.7V).
Sikkerhed:
- Kortslutningen af batteriet kan generere ekstra varme som kan føre til kablernes smeltning. Og som følge
brugerens skade.

2
Vi anbefaler at man monterer minimum en sikring på den positive eller negative pol af batteriet. For
belastninger op til 5A – en sikring på minimum 20A, For belastninger op til 15A – en sikring på minimum
45A,
Advarsel:
- Selv om Apple laderegulatorerne er beskyttet mod omvendt polaritet, skal brugeren alligevel være sikker på
at polariteten og tilslutningen er korrekt (positiv til positiv, negativ til negativ).
- Apple laderegulatoren er designet til indendørs brug.
- Alle solpanellerne tilsluttet til laderegulatoren skal være beregnet til 12V og strømmen må ikke overstige
max strøm som laderegulatoren er beregnet til.
Garanti:
Alle Sundaya laderegulator har 2 års garanti mod defekte komponenter eller fabriks fejl.
Garantien vil blive ugyldig under følgende vilkår:
- produktet viser tegn på at have været vådt eller været i flydende væsker.
- produktet viser tegn på at den har været åbnet eller forseglingen er brudt.
- produktet viser tegn på vold eller mishandling.
Mekaniske specifikationer:
Material: ABS Plastic
Farve: Grøn
Form: Rund
Mål: 120mm x 40mm
Terminals: 8mm
Elektriske specifikationer:
Nominal spænding: 12VDC
Selv strømforbrug: 4 mA
Current Model Apple 5: 5 Amp -0% +25%
Current Model Apple 15: 15 Amp -0% +25%
Lav spænding buzzer advarsels nieau: 11.70 V
Lav spænding afbrydelse: 11.50V ± 0.10V (-0.04V/A)
Udgang rekonnect niveau: 12.6V
Boost opladnings niveau 25/C: 14.5V (med temperatur kompensation -0.02V//C)
PWM float opladnings niveau: 14.10V (med temperatur kompensation -0.02V//C)
Sundaya International Pte., Ltd.

3
Kort / hurtig monteringsvejledning
(Følg nøje monterings vejledningen i den beskrivende rækkefølge!)
1. Monter solcellen fast på taget eller på den ønskede stativ. (Anbefalet mod syd i 45 grader
vinkel)
2. Monter laderegulatoren og batteriet et fast sted.
3. Tilslut batteri kabel til laderegulator ved at respektere polariteten plus og minus på kabel
og laderegulator.
4. Tilslut den anden ende af kablet med kabelsko til batteriet.
5. Tilslut kablet til solcelle på solcellen – vær opmærksom på plus og minus ( brun = plus, blå
= minus)
6. Tilslut solcellekablet til laderegulator. Tilslut lamper, radio, pumper eller TV til
laderegulatoren.
7. TV 14”, inverter, pumper eller andre apparater som bruger meget strøm eller mere end
laderen er beregnet, til, tilsluttes direkte til batteriet. Afmontering foregår i absolut omvendt
rækkefølge!
Det gælder også når du kun skifter batteriet.
Alle elektriske apparater og lamper som tilsluttes gennem laderegulatoren må ikke bruge
mere end 5Ampere.
Hvis du bruger to eller flere solceller skal de tilsluttes i parallel. Bruger man flere batterier
skal de også tilsluttes i parallel (plus med plus og minus med minus)
Lav aldrig kortslutninger ! Hvis sikringen på batteri kablet springer, undersøg først årsagen
til kortslutning, ved at fjerne apparater eller lamper som har alt for stor strømforbrug. Skift
sikringen med nøjagtig den samme størrelse. Undgår at improvisere.

4

Apple
General
Product name : Apple
Product description : 12VDC Battery Charge Regulator
Operating Temperature : -10°C to +55°C
Storage Temperature : -40°C to +85°C
Standard Available Types : Apple 5 Apple 10 Apple 15 Apple 20
Available Current Output/Input Model : 5 Ampere 10 Ampere 15 Ampere 20 Ampere
Electrical:
Nominal operating Voltage : 12VDC
Self consumption : 4 mA
Low Voltage Buzzer Warning Level : 11.70 V +/- 0.10 V
Low Voltage disconnect : 11.60 V +/- 0.10 V
Load Reconnect level : 12.60 V +/- 0.20 V
Boost Charge Level @25
0
c : 14.5V +/- 0.10 V (with Temperature compensation 0.02V/ deg c)
PWM float Charge level : 14.0V +/- 0.10 V (with Temperature compensation 0.02V/ deg c)
Level Indicator
Power consumption (on/off) : 0.1 A (max) / 0 A
Battery low Condition (0%) : 11.6 +/- 0.05 V
Battery Full Condition (100%) : 12.60 V +/- 0.10 V
Indicator for Battery State of Charge : (0 - 100%) LED bar (8 steps) with push button switch
Other indicators : - Indicator for Charging mode condition
- Indicator for Master Switch Off , Short/Overload condition
- Indicator for battery cut-off condition
Mechanical
Wiring & Terminals : 8mm width Input terminal for battery (bottom side)
8mm width Input terminal for solar panel (top side)
8mm width Output terminal for Load (top side)
Enclosure Materials : Fireretardant ABS / UV stabilized
Enclosure Color : Light Green
Connector material : Brass / Nickel plated
Product dimensions (HxDia) : 40mm x 120mm
Nett product weight : 0.20 kg
Mechanical Product Drawing
Protection and Sertifications
Reverse Polarity Protection : Yes
Short Circuit Protection : Yes
Over Load Protection : Yes
Surge Protection : Yes
Enclosure protection class : IP 42
CE Compliance : Yes
C-Tick Compliance : Yes
SNI Compliance : Yes
Packing Details
Standard packaging : 1 pcs.
Packing Dimensions (LxWxH) : 156
x 130 x 40 mm
Volume / Pcs. per m3 : 0.00095 m3 / 1050pcs. per m3
Specifications sheet
Because of continuous research and development of our products the information
and specifications in this data sheet are subject to change without prior notice.
Full
cut-off
Charging
FRONT VIEW SIDE VIEW BOTTOM VIEW
Battery
Solar Panel Input Load
# Sundaya
3/4
1/2
1/4
Master Switch Off
Short / Overload
On / Off
Display
Table of contents
Popular Controllers manuals by other brands

Johnson Controls
Johnson Controls FMS-2000C installation guide

AvL Technologies
AvL Technologies AAQ Handheld Setup & operation guide

SMC Corporation
SMC Corporation LECP6 Series Operation manual

AT&T
AT&T DLC-100 user manual

Emerson
Emerson AVENTICS NL1 operating instructions

Toho Electronics
Toho Electronics TTM-P4W Series instruction manual