1. Functional Description
1-1. Functional Description..........................P.1
1-2. Setting Procedure.................................P.1
2. Diagram of Functions and Settings
2-1. Diagram of Functions and Settings......P.2
3. Others
3-1.
Precautions When Selecting Settings
.....P.3
3-2. Factory Settings ...................................P.4
3-3. Error Display Indicator Readings .........P.4
3-4.
Introducing FX-301(P) Updated Version Unit
..P.5
4. Settings for NAVI Mode
4-1. NAVI Mode Functions and Settings.....P.6
4-2. Teaching Mode
[when using FX-301(P)(-HS) or FX-305(P) normal mode]
P.10
4-3. Teaching Mode
[when using FX-305(P) window comparator mode]
P.13
4-4. Threshold Value Fine Adjustment Mode
[when using FX-301(P)(-HS) or FX-305(P) normal mode]
P.19
4-5. Threshold Value Fine Adjustment Mode
[when using FX-305(P) window comparator mode]
P.20
4-6. Output Operation Setting Mode .........P.22
4-7. Timer Operation Setting Mode...........P.23
5. PRO1 Mode
5-1.
PRO1 Mode Functions and Settings
.....P.24
5-2. Response Time Change Function......P.27
5-3.
Timer Setting Function [FX-301(P)(-HS)]
....
P.28
5-4. Timer Setting Function [FX-305(P)]....P.29
5-5. Hysteresis Function............................P.31
5-6. Stability Function................................P.32
5-7. Shift Function .....................................P.33
5-8.
Light Emitting Amount Selection Function
..P.34
6. PRO2 Mode
6-1.
PRO2 Mode Functions and Settings....
P.35
6-2. Digital Display Setting Function .........P.37
6-3. Digital Display Inversion Function......P.38
6-4. ECO Mode Setting Function ..............P.39
7. PRO3 Mode
7-1.
PRO3 Mode Functions and Settings...
P.40
7-2. Data Bank Load Setting Function......P.41
7-3. Data Bank Save Setting Function......P.42
8. PRO4 Mode
8-1.
PRO4 Mode Functions and Settings...
P.43
8-2. Setting Contents Copy Function ........P.44
8-3.
Remote Data Bank Load Setting Function ..
P.45
8-4.
Remote Data Bank Save Setting Function..
P.46
8-5.
Selection for Communication Change to Permit / Not to Permit
..
P.47
8-6. Backup Setting Function....................P.48
9. PRO5 Mode
9-1.
PRO5 Mode Functions and Settings.....
P.49
9-2. Code Setting Function........................P.51
9-3. Adjust Lock Function..........................P.52
9-4. Setting Reset Function.......................P.53
9-5.
Interference Prevention Switching Function [FX-305(P) only]
....P.54
10.PRO6 Mode [FX-305(P) only]
10-1.
PRO6 Mode Functions and Settings....
P.55
10-2. Output 1 Sensing Mode Settings.....P.56
10-3. Output 2 Sensing Mode Settings.....P.58
11.Others
11-1. Key Lock Functions..........................P.59
11-2.
Threshold Value Confirmation Function
..P.59
PRO Mode Operation Guide
FX-301(P)(-HS)/305(P)
DIGITAL FIBER SENSOR
For the operation method of FX-301B/G/H, refer to ‘Digital fiber sensor FX-301/302/303 series
PRO mode operation guide’ on the SUNX home page.

Functional Description
1-1. Functional Description
1-2. Setting Procedure
1
1Operation indicator (Orange) …FX-301(P)(-HS) : Lights up when output is ON.
Output 1 operation indicator (Orange)
…
FX-305(P) : Lights up when output 1 is ON.
2Stability indicator (Green) …
Output 2 operation indicator (Orange)
…
3MODE indicator …RUN (Green) :
TEACH (Yellow) :
ADJ (Yellow) :
L/D (Yellow) :
TIMER (Yellow) :
PRO (Yellow) :
4Jog switch …Turning this switch in the ‘’or ‘’direction, allows different items to be viewed for
selection and pressing the switch then confirms the selected setting.
5MODE key …
This key is used to select operating modes and to cancel settings during the configuration process.
The [MODE key] and [Jog switch] are utilized to configure various settings.
Cancel: If the [MODE key] is pressed, the unit will return to the previous settings status, immediately before the
[Jog switch] was pressed (the selected setting has been confirmed).
Selection and confirmation of settings are performed according to the order of the numbers, as shown on the amplifier: 1, 2 and 3.
Press the [MODE key]
(mode selection / cancellation)
1
Turn the [Jog switch] in the ‘’or ‘’direction
(chooses setting for selection)
2Press the [Jog switch]
(confirms the selected setting)
3
1FX-301(P)(-HS): Operation indicator (Orange)
FX-305(P): Output 1 operation indicator (Orange)
2FX-301(P)(-HS): Stability indicator (Green)
FX-305(P): Output 2 operation indicator (Orange)
3MODE indicator
4Jog switch
5MODE key
, and are in the correct order for selecting settings.
Lights up during normal sensing operation.
When this indicator lights up, the ‘threshold value’can be set by
utilizing either ‘2-level teaching’, ‘limit teaching’or ‘full-auto teaching’.
When the FX-305(P) is in window comparator mode, the ‘threshold
value’can be set by either ‘1-level teaching’, ‘2-level teaching’or
‘3-level teaching’whenever this indicator lights up.
When this indicator lights up, fine adjustment of the ‘threshold value’
can be performed.
When this indicator lights up, the output operation can be set.
When this indicator lights up, timer operation can be set.
(Timer period can be set in PRO1 mode.)
When this indicator lights up, further advanced functions, such as the
copying and memory functions, can be set.
FX-301(P)(-HS) :
Lights up when the incident light intensity is great enough for stable operation.
FX-305(P) : Lights up when output 2 is ON.
1

Diagram of Functions and Settings
2-1. Diagram of Functions and Settings
2
The amplifier features and settings are generally classified into two main modes; the ‘NAVI mode’for items and
settings that are frequently reconfigured, and the ‘PRO mode’that contains more detailed settings.
Allows fine adjustment of the
‘threshold value’. (Refer to p.19~)
Adjust
ADJ
The ‘threshold value’can be set by utilizing
either ‘2-level teaching’, ‘limit teaching’or
‘full-auto teaching’. (Refer to p.10~)
This indicates normal sensing
operation.
Run
RUN
NAVI
mode
PRO
mode
Sets output operation either Light-
ON, or Dark-ON. (Refer to p.22)
L-ON / D-ON
L/D
Configures operation of the timer.
(Refer to p.23)
Timer
TIMER
Switches among response
times. (Refer to p.27)
Response Time Change
Configures timer operation.
(Refer to p.28~)
Timer Setting
Sets hysteresis level.
(Refer to p.31)
Hysteresis
Teaching
TEACH
PRO1
PRO2
PRO3
PRO4
PRO5
Shifts the ‘threshold value’by a
certain percentage increment in
‘limit teaching’. (Refer to p.33)
Shift
Permits selection of stability indicator response
levels for changes in the range for lighting up.
(Refer to p.32) [FX-301(P)(-HS) only]
Stability
Changes the light emitting a-
mount selection setting. (Refer
to p.34)
Light Emitting Amount Selection
Allows selection of different
content to be indicated in the
digital display. (Refer to p.37)
Digital Display Setting
Sets the viewing orientation of
the digital display.
(Refer to p.38)
Digital Display Inversion
Sets the digital display to turn
ON / OFF.
(Refer to p.39)
ECO Mode
Loads configuration setting from
the data bank. (Refer to p.41)
Data Bank Load
Saves configuration setting into
the data bank. (Refer to p.42)
Data Bank Save
Using optical communications, configuration
settings from the main unit are copied to
connected sub units all at once. (Refer to p.44)
Copy
Using optical communication, configuration
settings can be loaded from respective
data banks all at once. (Refer to p.45)
Remote Data Bank Load
Using optical communication, current configu-
ration settings can be saved into respective
data banks all at once. (Refer to p.46)
Remote Data Bank Save
Allows basic configuration information
to be set in a single step, by inputting
a 4-digit code. (Referto p.51)
Code
Allows fine adjustment of the ‘threshold
value’to be directly performed during
RUN mode. (Refer to p.52)
Adjust Lock
All settings, except for data
bank information, revert to
factory settings. (Refer to p.53)
Reset
Switches the number of units for which
interference prevention switching is enabled.
* FX-305(P) only. (Refer to p.54)
Interference Prevention
Switching
P.24~
P.35~
P.40~
P.43~
P.49~
When using optical communication for carrying out copy /
load / save operations all at once, this function allows optical
communication to pass through the unit. (Refer to p.47)
Communication Change
To Permit / Not to Permit
Allows not to save the threshold
value, by teaching via external
input in EEPROM. (Refer to p.48)
* The FX-301(P)-HS is not
equipped with a PRO4
setting function.
Backup
The items that can be set are different for output 1 and output 2.
P.55~
Output 1
Output 2
Sets a threshold value for ON /
OFF operation. (Refer to p.56)
Normal Mode
Judges if set two threshold values are within the
required range or not. This can be selected in
1-level / 2-level / 3-level teaching. (Refer to p.56)
Window Comparator Mode
Sensing mode that cancels out slight changes in
light intensity so that only sudden increases in
incident light intensity are sensed. (Refer to p.56)
Rising Differential Mode
PRO6
Trailing Differential Mode
Sensing mode that cancels out slight changes in
light intensity so that only sudden decreases in
incident light intensity are sensed. (Refer to p.56)
Error Output
Output when overcurrent occurs or when
a communication error occurs from
connected incompletely. (Refer to p.58)
Alarm Output
Be used as alarm output when the threshold
value for output 2 is linked to output 1 and
the light amount drops. (Refer to p.58)
Available only
in FX-305(P)
*
When the FX-305(P) is in window comparator mode,
the ‘threshold value’can be set by either ‘1-level
teaching’, ‘2-level teaching’or ‘3-level teaching’.
Allows various detailed settings to be configured, such as
optical communications, save / load and other settings.
Pro
PRO
2

Others
3-1. Precautions When Selecting Settings
3
Press the MODE
key once.
Example:When operating in PRO mode.
Press the Jog
switch.
To cancel
Canceling operations
1Select ‘PRO mode’.
To cancel any operation, press the [MODE key]. If the [MODE key] is pressed once, the unit will return to
the previous settings status immediately before the [Jog switch] was pressed.
When changing the status of any setting, ensure that the selected setting is subsequently confirmed.
If confirmation is not performed, the new setting will not take effect.
Confirming settings
Example:When setting response time change.
(In case of FX-301)
S-D
(reduced intensity)
STD
(standard)
H-SP
(ultra high-speed)
FAST
(high-speed) LONG
(long-range)
Press the
Jog switch.
Press the
Jog switch.
The digital display will quickly blink 3 times to
confirm the setting.
2If the [Jog switch] is pressed, the current mode
will be displayed.
* The factory setting is ‘STD (standard)’.
4If the [Jog switch] is pressed, the digital display
will quickly blink 3 times, confirming the setting.
Setting protection
1Select ‘response time change’.
2If the [Jog switch] is pressed once, the unit will enter
the ‘response time change’state.
3If the [Jog switch ] is turned, the digital display
will blink.
Select the desired mode.
3To cancel the ‘response time change’operation,
press the [MODE key] once.
4The display will return to the previous [PRO1 mode]
selection screen.
You can use the ‘key lock function’to protect settings. (Refer to p.59.)
Key lock function
This function can be used to prevent the operator from accidentally changing the sensor settings.
Turn the Jog switch to select
the desired mode.
3

3-2. Factory Settings
Factory settings for the FX-301(P)(-HS)/305(P) are indicated below:
If the unit is reset using the ‘9-4 Setting Reset Function’from ‘PRO5 Mode’on p.53, the resulting settings will be
those indicated below:
Output 1:
,
Output 2:
Model No.
Item
Response time
Timer period
Hysteresis
Stability
Shift amount during limit teaching
Light emitting amount selection function
Display
Display turning
ECO mode
Selection for transmission change to permit / not to permit
Backup
Code
Adjust lock
Interference prevention switching function [FX-305(P) only]
Sensing mode [FX-305(P) only] (Note)
Settings
Standard (standard)
10 ms
H-02 (standard)
S-02 (standard)
15 %
Level 4 (MAX)
Incident light intensity display
OFF
OFF
OFF
ON
0004
ON
Settings
40
L-ON
Without timer
Digital display
FX-301(P)FX-301(P)-HS
Digital displaySettings
80
L-ON
Without timer
Digital display Digital display
FX-301(P)Error description
FX-305(P)Measures
Turn off the power, then check the
load.
Confirm that all amplifiers are
properly connected to each other.
The load has short-circuited and excess
current is flowing.
: Output 1, : Output 2
FX-301(P)FX-301(P)-HS
FX-305(P)
FX-305(P)
Settings
Standard F (standard 2)
10 ms
H-02 (standard)
15 %
Level 4 (MAX)
Incident light intensity display
OFF
OFF
OFF
ON
J004
ON
IP-1
Normal mode
Settings
Output 1: 80, Output 2:120
L-ON
Without timer
Digital display
Settings
H-SP (ultra high-speed)
10 ms
H-02 (standard)
S-02
(standard)
15 %
Level 2
Incident light intensity display
OFF
OFF
ON
004
ON
Digital display
NAVI mode
PRO mode
3-3. Error Display Indicator Readings
In case of errors, attempt the following measures:
Note: In window comparator mode, the factory settings for teaching method is ‘2-level teaching’.
Model No.
Item
Threshold value
Light-receiving operation
Timer operation
Communication error has occurred at
time of connection.
In case of using functions of PRO4
mode
()
(ON when light is received) (ON when light is received)(ON when light is received)
4

3-4. Introducing FX-301(P) Updated Version Unit
Upgraded functions
Changes in appearance
Updated version units of the FX-301(P) (red LED type) have been manufactured since June 2004. There are
some differences in the functions and communication method between these units and previous version units.
Before change After change
Top view
Side view
Name
plate
Display
Uses special parts
*
‘NAVI’is printed on the both sides
* ‘NAVI’is printed only on a side
Top view
Side view
Change in shape
of jog switch
Added to
name plate
Checking minor changes between previous and new models can be
done by checking whether the printing is on both sides or only one side.
An ultra high-speed mode (H-SP) has been added to the existing
4 response time modes [high-speed (FAST), reduced intensity
(S-D), standard (STD) and long range (LONG)].
This is changed using ‘’in ‘’.
1. Response times added
Before change After change
4 steps 150 !s (FAST)
250 !s (S-D)
250 !s (STD)
2 ms (LONG)
5 steps
150 !s (FAST)
65 ¨s (added)(H-SP)
250 !s (S-D)
250 !s (STD)
2 ms (LONG)
2. Extension of timer period
The setting range for the timer period was previously 500 ms, but
this has been extended to a new range of 9999 ms.
3. Light emitting amount selection function
The light emitting amount can be changed to one of 4 levels
(5 levels when emission halt is included). However, the number of
levels that can be set will vary depending on the response time
settings.For further details, refer to p.34.
4. Backup, copy lock and key lock functions added
Backup
Copy lock
Key lock
: This selects whether or not threshold values set by
teaching are written to (stored in) an EEPROM.
: This selects whether copy function and data bank
function communication are possible or not.
: This disables input using switches to prevent
accidental changing of settings.
Digital display only
Previous version unit: Sensitivity surplus is indicated by the number
of blinks of the stability indicator.
After change
Changes in operation
1.Timer selection method
Previous version unit:
Timer type was changed using PRO1 mode.The ‘TIMER’
setting in NAVI mode could onlybe turned on or off.
After change :The type of timer can be changed using the
‘TIMER’function in NAVI mode.
Display changes
1. Checking blinking of sensitivity margin
The stable margin display method after teaching has been changed.
2. Initial direct code value changed
The factory default settings for the direct codes have been changed.
2. Checking threshold value in RUN mode
After change:The threshold values can be checked by turning the jog switch.
Previous version unit 0000
m The default setting for the timer period is 10 ms, and the direct code for
10 ms is ‘4’, so this has been changed.
After change 0004
Internal circuit changes
1. Addition of an APC circuit
A four-chemical emitting element which provides stable sensing
over long periods has been added, as well as an APC (Auto
Power Control) circuit that improves stability during short periods.
1Program the sensor to indicate ‘PRO4’.
2Press the ‘jog switch’and the ‘MODE key’
simultaneously.
3
When stop pressing the ‘jog switch’and the ‘MODE key’,
the spec. is set and ‘PRO4’is indicated.
The optical communications
spec. of the group B The optical communications
spec. of the group A
Stop optical
communications
•When the units of the group A and the group B are connected in
cascade as Figure B shown above, optical communications cannot
be done. When the optical communications function is used,
connect them as Figure A shown above. If the units cannot be
placed as Figure A, the following measure 1or 2should be
taken.
Affix the communication window seal of the accessory amplifier
protection seal (FX-MB1) to the communication window of the
amplifier.
If the measure 1described above cannot be taken, change the
optical communications spec.of the group B units.
1
2
Cautions on sensor connection in cascade
When the units in the group A and the group B shown in the table
below are connected in cascade, connect them in cascade as
Figure A shown below.
<Figure A><Figure B>
Optical communications
are possible Optical communications
are impossible
Group A Group B Group A
Group B
•
Group A
Group B
FX-301(P): Updated version
unit, FX-305(P),
FX-301(P)-C1
FX-301(P): Previous
version unit,
FX-301G(P) / B(P) / H(P),
FX-302(P), FX-303(P),
LS-400 series (Note 1)
How to change the optical communications spec. of Group B units
Follow the procedure given below to change the optical
communications spec. of the group B units. Be sure to set the
optical communications spec. to ‘3 (the optical communications
spec. of the group A)’or ‘0 (stop of the optical communications)’.
•
Notes:1)
When LS-400 series is connected
with the digital fiber amplifier in
cascade, be sure to locate LS-400
series at the left-most position (when
viewed from the connector side).
Every time the jog switch and the MODE key are pressed simul-
taneously, the indicated No.will change from ‘5’n‘0’n‘0’n‘3’n‘5’in turn.
Notes: 2)
When the optical communications spec. is set to ‘3 (the optical communications
spec. of the group A)’, be sure to mount the units close together. Furthermore,
take care of the following.
The optical communications function may not be usable due to the environment. etc.
Do not carry out the collective channel load or save.
•
•
Notes: 3)
<Procedure to change>
5

Settings for NAVI Mode
4-1. NAVI Mode Functions and Settings
4
In [NAVI mode], frequently changed settings can be easily configured.
Settings for four functions can be configured.
RUN :
Normal Sensing Operation
TEACH : Teaching Mode
This indicates normal sensing operation. Incident light intensity is displayed in real
time. The factory setting is that the ‘threshold value’cannot be changed directly.
When the ‘Adjust Lock Function’in ‘PRO5 Mode’is disabled, manual fine adjustment
of the ‘threshold value’can be performed during normal sensing operation.
The threshold value can be confirmed by turning the jog switch (Refer to p.59). In
addition, key lock function can also be set (Refer to p.59).
This mode sets the ‘threshold value’by utilizing teaching.
When using FX-301(P)(-HS) or FX-305(P) normal mode
The ‘threshold value’can be set with any of the 3 teaching methods, ‘2-level
teaching’, ‘limit teaching’and ‘full-auto teaching’.
2-level teaching is a method of setting the threshold value by teaching the
amplifier unit two different status conditions - sensing object present and sensing
object absent.
The ‘threshold value’is usually set using this method.
Sensing operation * Sensing operation when ‘threshold value’
can be fine adjusted
Refer to the section entitled ‘9-3. Adjust Lock
Function’from ‘PRO5 Mode’on p.52.
Refer to p.10 ~ for setting procedure
P.10
2-level Teaching
Thru-beam type Reflective type
Sensing object present Sensing object absent Sensing object present Sensing object absent
Teaches only the status condition in which no sensing object is within sensing
range (status in which incident light intensity is stable). This method is used to set
a ‘threshold value’for conducting sensing in the presence of a background, or
when extremely small objects are to be detected.
P.11
Limit Teaching
P.12
Full-auto Teaching
This method is used to set the threshold value while the sensing objects are still
moving on the production line, without stopping the production line.
Thru-beam type
Thru-beam type
Reflective type
Reflective type
Background
Minute
object
6

TEACH : Teaching Mode
Refer to p.13 ~ for setting procedure
P.13~
1-level Teaching
When using FX-305(P) window comparator mode
The ‘threshold value’can be set with any of the 3 teaching methods, ‘1-level
teaching’, ‘2-level teaching’and ‘3-level teaching’. By setting two ‘threshold
values’, both ON and OFF can occur between the two threshold value levels.
This sets the shift value to any desired value, and sets the threshold values (1_SL,
2_SL) by means of 1-level teaching.
P.15~
2-level Teaching
This carries out 2-level teaching (P-1, P-2) and sets the threshold values (1_SL,
2_SL).
ON
0
P.17~
3-level Teaching
This carries out 3-level teaching (P-1, P-2, P-3) and sets the threshold value
(1_SL) between A and B and the threshold value (2_SL) between B and C as
shown in the diagram below.
After teaching, P-1, P-2 and P-3 are automatically assigned in ascending order to
‘A’, ‘B’, and ‘C’.
Hysteresis
Output
(L-ON)
4,000 / 9,999 Incident light
intensity
ON
1_SL 2_SL
OFF
Time
Shift value
Shift value
ON
1_SL
2_SL
P-1
0
P-1 2_SL1_SL
Output
(L-ON)
Shift value
OFF
Incident light
intensity
4,000 / 9,999
Output
(L-ON)
OFF ON OFF
Time
ON
P-11_SL
P-22_SL
0
OFF
Incident light
intensity
4,000 / 9,999
Output
(L-ON)
Output
(L-ON)
P-1
1_SL
OFF ON OFF
P-2
2_SL
* In this figure, the incident
light intensity of P-1 is
less than that of P-2.
Time
ON
A
1_SL
2_SL
B
C
0
OFF
Incident light
intensity
4,000 / 9,999
Output
(L-ON)
Output
(L-ON)
P-1
1_SL
OFF ON OFF
P-2
2_SL
P-3
When using FX-305(P) differential mode
Sensing of only sudden changes in incident light intensity is carried out, so that
this is ideal for sensing edges of object such as glass.
Set to ‘full-auto teaching’if teaching is to be carried out.(Refer to p.12 for details.)
Furthermore, if the response time has been set in STDF, LONG or U-LG mode,
mount to make the threshold values to more than the following values.
STDF mode : 40 digits
LONG mode: 60 digits
U-LG mode : 100 digits
•
•
•
7

ADJ : Threshold Value Fine Adjustment Mode
This mode allows fine adjustment of the ‘threshold value’setting.
When the incident light intensity display has been selected, the threshold value
can be adjusted in increments as low as a one digit.
When the percentage display has been selected, the threshold value can be
adjusted in increments of one digit (varies depending on the ‘threshold value’).
However, when FX-305(P) is in window comparator mode, the percentage display
function cannot be utilized.
* The factory setting is; FX-301(P): 40, FX-301(P)-HS: 80,
FX-305(P) output 1: 80, FX-305(P) output 2: 120.
Refer to p.19~ for setting procedure
0Threshold value
Threshold
value 1 Threshold
value 2
Incident light intensity
Output operation
L-ON
D-ON
Output operation
L-ON
D-ON
* The factory setting is L-ON (Light-ON).
0
L/D: Output Operation Setting Mode
Refer to p.22 for setting procedure
When using FX-301(P)(-HS) or FX-305(P) normal mode
When using FX-305(P) window comparator mode
When set to ‘L-ON’, the output will be ON if the incident light intensity becomes
greater than the ‘threshold value’.
When set to ‘D-ON’, the output will be ON if the incident light intensity becomes
less than the ‘threshold value’.
When set to ‘L-ON’, if the incident light intensity is between the two ‘threshold
value’levels, the output will be ON. If the incident light intensity is outside of the
two threshold value levels, the output will be OFF.
When set to ‘D-ON’, if the incident light intensity is between the two ‘threshold
value’levels, the output will be OFF. If the incident light intensity is outside of the
two threshold value levels, the output will be ON.
This mode allows the selection of output operation from either L-ON (Light-ON), or
D-ON (Dark-ON).
When using rising differential mode
Output
operation
L-ON Time
ON
Output
operation
L-ON
D-ON
ON
TT
OFF
When using trailing differential mode
Time
ON
OFF
OFF
ON
OFF
TT
Incident
light
intensity
Incident
light
intensity
*The output time ‘T’can be set by changing
the timer period in timer setting mode
(initial value: 10 ms).
*The output time ‘T’can be set by changing
the timer period in timer setting mode
(initial value: 10 ms).
For L-ON, output is ON for a constant period of time when the incident light
intensity is rising.
For D-ON, output is OFF for a constant period of time when the incident light
intensity is rising.
For L-ON, output is ON for a constant period of time when the incident light
intensity is trailing.
For D-ON, output is OFF for a constant period of time when the incident light
intensity trailing.
Incident light intensity
0 4,000 / 9,999
ONOFF
OFFON
ONOFF OFF
OFFON ON
0 4,000 / 9,999
TT
D-ON
TT
8

PRO mode allows the configuration and usage of the following timer
operations: OFF-delay / ON-delay / ONE SHOT.
Timer period can be selected from 0.5 ms to 9,999 ms.
Please refer to the section entitled ‘5-3. Timer Setting Function [FX-301(P)(-HS)]’
from ‘PRO1 Mode’on p.28.
PRO mode allows the configuration and usage of the following
timer
operations: OFF-delay / ON-delay / ONE SHOT / ON-delay •OFF-delay /
ON-
delay •ONE SHOT.
Timer period can be selected from 0.5 ms to 9,999 ms.
Please refer to the section entitled ‘5-4. Timer Setting Function [FX-305(P)]’
from ‘PRO1 Mode’on p.29.
TIMER : Timer Operation Setting Mode
Refer to p.23 for setting procedure
FX-305(P)
This mode sets the timer operation and set the type of timer.
For FX-301(P)(-HS) the setting can be selected from Without timer / OFF-delay /
ON-delay / ONE SHOT timer, and the FX-305(P) includes these and also
ON-delay •OFF-delay / ON-delay • ONE SHOT timers.
FX-301(P)(-HS)
9

10
4-2. Teaching Mode [when using FX-301(P)(-HS) or FX-305(P) normal mode]
The ‘threshold value’can be set by utilizing three kinds of teaching, whichever ‘2-level teaching’, ‘limit teaching’or ‘full-auto teaching’.
* The factory setting is this mode for FX-305(P). (Refer to p.55)
2-level teaching is a method of setting the ‘threshold value’by teaching the amplifier two different
status conditions - sensing object present and sensing object absent. The ‘threshold value’is
usually set using this method.
2-level Teaching
1Press the [MODE key] once to select ‘TEACH mode’.
3Press the [Jog switch] when in the status condition of -
sensing object is present.
2FX-305(P): Turn the [Jog switch] to select the desired
‘output’for setting.
5Press the [Jog switch] when in the status condition of -
sensing object is absent.
8The ‘threshold value’setting will be displayed.
9The incident light intensity will again be displayed, indicating
that configuration is now complete.
FX-305(P): The output that has been set will be displayed.
0Press the [MODE key] 5 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’(normal
sensing operation).
4The digital display will blink and indicate the incident light
intensity reading, then the MODE indicator / TEACH
(yellow) will blink.
This indicates that the second point item is now ready for
input.
6
The digital display will again blink and indicate the incident light intensity reading
and the ‘threshold value’will be set to a value midway between the incident
light intensities when the sensing object is present and when it is absent. The
blinking MODE indicator / TEACH will stop blinking and continuously light up.
*
Fine adjustment of the ‘threshold value’can be performed in the ‘4-4.
Threshold Value Fine Adjustment Mode [when using FX-301(P)(-HS) or
FX-305(P) normal mode]’described on p.19.
()
7The sensing stability status will be displayed.
•When stable sensing can be performed
nThe digital display will blink the word ‘’.
•When stable sensing cannot be performed
nThe digital display will blink the word ‘’.
Place a fiber within sensing range.
Turn the Jog switch to select
the desired output for setting.
Press the
MODE key once.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Status condition - sensing object is present
Status condition - sensing object is absent
Stable sensing
Output 1 Output 2
In case of FX-301(P)(-HS)
In case of FX-305(P)
Thru-beam type Reflective type
Thru-beam type Reflective type
Difference between incident light
intensities is not great enough.
Press the MODE key
5 times or keep it pressed
for 2 . or more.

Teaches only the status condition in which no sensing object is within sensing range (status in
which incident light intensity is stable). This method is used to set a threshold value for
conducting sensing in the presence of a background, or when extremely small objects are to be
detected.
Limit Teaching
1Press the [MODE key] once to select ‘TEACH mode’.
3Press the [Jog switch] when in the status condition of -
sensing object is absent.
2FX-305(P): Turn the [Jog switch] to select the desired
‘output’for setting.
5Turn the [Jog switch] in the ‘’or ‘’direction.
When using thru-beam fiber
When using reflective fiber
6The sensing stability status will be displayed.
•
When stable sensing can be performed
nThe digital display will blink the word ‘’.
•
When stable sensing cannot be performed
nThe digital display will blink the word ‘’.
7The ‘threshold value’setting will be displayed.
•
If the switch is turned toward the ‘’direction, the digital display will scroll
from the left to the right (twice) and the threshold value will be shifted down by
approximately 15 %, to a value lower than the incident light intensity reading.
•
If the switch is turned toward the ‘’direction, the digital display will scroll
from the right to the left (twice) and the threshold value will be shifted up by
approximately 15 %, to a value higher than the incident light intensity reading.
*
The initial factory-set value of the shift amount is approximately 15 %.
The shift amount can be changed by utilizing the ‘5-7. Shift Function’from ‘PRO1 Mode’,
described on p.33. (The percentage adjustment is variable from 0 % to 80 %, in increments of 5 %.)
4The digital display will blink and indicate the incident light
intensity reading, then the MODE indicator / TEACH
(yellow) will blink.
Press the
MODE key once.
Status condition - sensing object is absent
Press the MODE key
5 times or keep it pressed
for 2 sec.or more.
Turn the Jog switch
in the ‘’or ‘’ direction.
The digital display will
scroll (twice).
Press the
Jog switch.
Stable sensing
Turn the Jog switch to select
the desired output for setting.
Press the
Jog switch.
Output 1 Output 2
Place a fiber within sensing range.
Minute
object
In case of FX-301(P)(-HS)
In case of FX-305(P)
Background
Thru-beam type Reflective type
Stable sensing cannot be performed.
9Press the [MODE key] 5 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’(normal
sensing operation).
8The incident light intensity will again be displayed, indicating
that configuration is now complete.
FX-305(P): The output that has been set will be displayed.
11

12
Stable sensing Difference between
incident light intensities
is not great enough.
Full-auto teaching is used to set the threshould value while the sensing objects are still moving on the
production line, without stopping the production line.
* When the FX-305(P) is in differential sensing mode, set the threshold value by full-auto teaching.
(Refer to p.55)
Full-Auto Teaching
1Press the [MODE key] once to select ‘TEACH mode’.
7The ‘threshold value’setting will be displayed.
5The threshold value is set to a value midway between the
incident light intensities in the object present and object
absent conditions.
9Press the [MODE key] 5 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’(normal
sensing operation).
8The incident light intensity will again be displayed, indicating
that configuration is now complete.
4‘’is displayed on the display.
Release the jog switch when the object has passed.
* The incident light intensity is read when ‘’is displayed.
3In the status condition keep the [Jog switch] pressed for
0.5 sec. or more, when the object is moving on the
production line.
2FX-305(P): Turn the [Jog switch] to select the desired
‘output’for setting.
6The sensing stability status will be displayed.
•When stable sensing can be performed
nThe digital display will blink the word ‘’.
•When stable sensing cannot be performed
nThe digital display will blink the word ‘’.
Place a fiber within sensing range.
Status condition-moving the production line.
Press the MODE
key once.
Keep the Jog
switch pressed.
Press the MODE key
5 times or keep it pressed
for 2 sec.or more.
Turn the Jog switch to select
the desired output for setting.
Press the
Jog switch.
Output 1 Output 2
In case of FX-301(P)(-HS)
In case of FX-305(P)

This is the method of setting the threshold
values (1_SL, 2_SL) by one level (P-1) teaching.
The shift value can be set as desired.
*
The shift value units can be selected from two units:‘digit’or‘%’.
*
The shift value of the factory setting is set to‘100’of‘digit’units.
To set the shift value, refer to the section entitled‘10-2. Output
1 Sensing Mode Settings’from‘PRO6 Mode’on p.56.
1Press the [MODE key] once to select ‘TEACH mode’.
2Press the [Jog switch] to select ‘output 1’.
4-3. Teaching Mode [when using FX-305(P) window comparator mode]
1-level Teaching
The ‘threshold value’can be set using ‘1-level teaching’, ‘2-level teaching’or ‘3-level teaching’. When FX-305(P) is in window
comparator mode, teaching is performed using the teaching methods described in the section entitled ‘10-2. Output 1 Sensing Mode
Settings’ from ‘PRO6 Mode’on p.56. To change the teaching method, follow the procedures also described under the same heading.
* Window comparator mode can be set for output 1 only.
* The factory setting is ‘1-level teaching ( )’.
3The current teaching method will be displayed for 0.5 sec.,
and then the unit will enter the ‘P-1’setting state.
1Press the [MODE key] 5 times to select ‘PRO mode’.
2Turn the [Jog switch] 6 times towards the ‘’direction to
select ‘PRO mode’.
3Turn the [Jog switch] to select ‘output 1’, and then press the
[Jog switch] to confirm the setting.
4Turn the [Jog switch] to select ‘window comparator mode’,
and then press the [Jog switch] to confirm the setting.
5Turn the [Jog switch] to select ‘1-level teaching’, and then
press the [Jog switch] to confirm the setting.
4If the [Jog switch] is pressed while in the status condition
when a sensing object is present that can be used as a
baseline, then the display will blink and indicate the incident
light intensity reading.
Time
Shift value
Shift value
1_SL
2_SL
P-1
0
Incident light
intensity
9,999
Output
(L-ON)
P-1
2_SL1_SL
Output
(L-ON)
Shift value
OFF ON OFF ON
OFF
For further details, refer to ‘10-2. Output 1 Sensing Mode Settings’on p.56.
The status condition when a sensing object is
present that can be used as a baseline.
Setting in PRO6 mode beforehand
Setting in NAVI mode
Incident light
intensity of P-1.
Press the
Jog switch.
Press the
Jog switch.
Turn the Jog switch
6 times toward the
‘’direction.
Turn the Jog switch
to select output 1.
Press the
MODE key once.
Press the MODE key
3 times or keep it pressed
for 2 sec.or more.
Output 1
Press the
MODE key 5 times.
Turn the Jog switch
to select window
comparator mode.
Turn the Jog switch
to select 1-level
teaching.
To be continued on the next page 13

14
Press the MODE key 5 times
or keep it pressed for 2 sec.
or more.
9Press the [MODE key] 5 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’(normal
sensing operation).
6The setting for ‘lower limit value 1_SL’will be displayed.
7The setting for ‘upper limit value 2_SL’will be displayed.
5The display will indicate whether the upper and lower
threshold value limits have been correctly set or not.
•If ‘ ’ is blinking…the upper and lower limits have
been set correctly.
•If ‘ ’ is blinking…the upper and lower limits have
not been set correctly.
* The factory setting for shift value is‘100’.
To set the shift value, refer to the section entitled
‘10-2. Output 1 Sensing Mode Settings’from ‘PRO6 Mode’
on p.56.
8The output 1 will again be displayed, indicating that
configuration is now complete.
Lower limit value 1_SL
Upper limit value 2_SL
Upper and lower limits have
not been correctly set.
Stable sensing

The status condition when a sensing object is present
that can be used as a baseline for the lower limit.
2-level Teaching This is a method of setting the thresh-
old values (1_SL, 2_SL) by two levels
(P-1, P-2) teaching.
Select ‘2-level teaching ( )’in
PRO6 mode beforehand.
1Press the [MODE key] once to select ‘TEACH mode’.
2Press the [Jog switch] to select ‘output 1’.
3The current teaching method will be displayed, and then the
unit will enter the ‘P-1’setting state.
4If the [Jog switch] is pressed while in the status condition
when a sensing object is present that can be used as a
baseline for the lower limit, then the display will blink and
indicate the incident light intensity reading.
When using thru-beam type fiber
•Press the [Jog switch] for the sensing object that has the
greatest amount of interrupted light.
When using reflective type fiber
•Press the [Jog switch] for the sensing object with the
lowest incident light intensity.
Note) Even if procedures 4and 6are reversed, teaching for a
sensing object with low incident light intensity will
automatically cause the setting of ‘lower limit value 1_SL’.
Time
ON
P-11_SL
P-22_SL
0
OFF
Incident light intensity
9,999
Output
(L-ON)
P-1
1_SL
OFF ON OFF
P-2
2_SL
Output
(L-ON)
Turn the Jog switch
6 times toward the
‘’direction.
Turn the Jog switch
to select output 1.
Press the MODE key
3 times or keep it pressed
for 2 sec.or more.
Press the
MODE key 5 times.
Turn the Jog switch
to select window
comparator mode.
Turn the Jog switch
to select 2-level
teaching.
1Press the [MODE key] 5 times to select ‘PRO mode’.
2Turn the [Jog switch] 6 times towards the ‘’direction to
select ‘PRO mode’.
3Turn the [Jog switch] to select ‘output 1’, and then press
the [Jog switch] to confirm the setting.
4Turn the [Jog switch] to select ‘window comparator mode’,
and then press the [Jog switch] to confirm the setting.
5Turn the [Jog switch] to select ‘2-level teaching’, and then
press the [Jog switch] to confirm the setting.
For further details, refer to ‘10-2. Output 1 Sensing Mode Settings’on p.56.
Setting in PRO6 mode beforehand
Setting in NAVI mode
Press the
MODE key once.
Incident light
intensity of P-1.
Press the
Jog switch.
Press the
Jog switch.
Output 1
To be continued on the next page
15

16
The status condition when a sensing object is present
that can be used as a baseline for the upper limit.
Upper and lower limits have
not been correctly set.
8The setting for ‘lower limit value 1_SL’will be displayed.
9The setting for ‘upper limit value 2_SL’will be displayed.
0The output 1 will again be displayed, indicating that
configuration is now complete.
APress the [MODE key] 5 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’(normal
sensing operation).
Press the MODE key 5 times
or keep it pressed for 2 sec.
or more.
6If the [Jog switch] is pressed while in the status condition
when a sensing object is present that can be used as a
baseline for the upper limit, then the display will blink and
indicate the incident light intensity.
When utilizing thru-beam type fiber
•Press the [Jog switch] for the sensing object that has the
least amount of interrupted light.
When utilizing reflective type fiber
•Press the [Jog switch] for the sensing object with the
greatest incident light intensity .
5The unit will enter the ‘P-2’setting state and ‘TEACH’(yellow)
will blink on the MODE display.
7The display will indicate whether the upper and lower limits
have been correctly set or not.
•If ‘ ’ is blinking…the upper and lower limits have
been set correctly.
•If ‘ ’ is blinking…the upper and lower limits have not
been set correctly.
Incident light
intensity of P-2.
Lower limit value 1_SL
Upper limit value 2_SL
Press the
Jog switch.
Stable sensing

3-level Teaching
This is a method of setting the threshold range by three
levels (P-1, P-2, P-3) teaching and set the threshold values
at the middle of ‘A’and ‘B’(1_SL) and ‘B’and ‘C’(2_SL).
After teaching, P-1, P-2 and P-3 are automatically
assigned in ascending order to ‘A’, ‘B’, and ‘C’.
Select ‘3-level teaching ( )’in PRO6 mode
beforehand.
The status condition when sensing object ‘A’is present
that has the lowest incident light intensity.
1Press the [MODE key] once to select ‘TEACH mode’.
2Press the [Jog switch] to select ‘output 1’.
3The current teaching method will be displayed, and then the
unit will enter the ‘P-1’setting state.
4If the [Jog switch] is pressed while in the status condition
when sensing object ‘A’is present that has the lowest
incident light intensity, then the display will blink and indicate
the incident light intensity reading.
And then the unit will enter the ‘P-2’setting state and
‘TEACH’(yellow) will blink on the MODE display.
Note) ‘P-1’, ‘P-2’and ‘P-3’are set in that order even if
procedures 4, 5and 6are changed around.
Output
(L-ON)
Time
ON
A
1_SL
2_SL
B
C
0
OFF
Incident light
intensity 9,999
Output
(L-ON)
P-1
1_SL
OFF ON OFF
P-22_SLP-3
AB C
For further details, refer to ‘10-2. Output 1 Sensing Mode Settings’on p.56.
Setting in PRO6 mode beforehand
Turn the Jog switch
6 times toward the
‘’direction.
Turn the Jog switch
to select output 1.
Press the MODE key
3 times or keep it pressed
for 2 sec.or more.
Press the
MODE key 5 times.
Turn the Jog switch
to select window
comparator mode.
Turn the Jog switch
to select 3-level
teaching.
1Press the [MODE key] 5 times to select ‘PRO mode’.
2Turn the [Jog switch] 6 times towards the ‘’direction to
select ‘PRO mode’.
3Turn the [Jog switch] to select ‘output 1’, and then press
the [Jog switch] to confirm the setting.
4Turn the [Jog switch] to select ‘window comparator mode’,
and then press the [Jog switch] to confirm the setting.
5Turn the [Jog switch] to select ‘3-level teaching’, and then
press the [Jog switch] to confirm the setting.
Setting in NAVI mode
Press the
MODE key once.
Incident light
intensity of P-1.
Press the
Jog switch.
Press the
Jog switch.
Output 1
To be continued on the next page 17

18
5If the [Jog switch] is pressed while in the status condition
when sensing object ‘B’is present that has an incident light
intensity in between that of sensing object ‘A’and sensing
object ‘C’, the display will blink and indicate the incident light
intensity reading.
And then the unit will enter the ‘P-3’setting state.
The status condition when sensing object ‘B’is present that
has an incident light intensity in between that of sensing
object ‘A’and sensing object ‘C’.
Upper and lower limits have
not been correctly set.
The status condition when sensing object ‘C’is present
that has the greatest incident light intensity.
Press the MODE key 5 times
or keep it pressed for 2 sec.
or more.
0The output 1 will again be displayed, indicating that
configuration is now complete.
APress the [MODE key] 5 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’(normal
sensing operation).
6If the [Jog switch] is pressed while in the status condition
when sensing object ‘C’is present that has the greatest
incident light intensity, the display will blink and indicate the
incident light intensity reading.
8The setting for ‘lower limit value 1_SL’will be displayed.
9The setting for ‘upper limit value 2_SL’will be displayed.
7The display will indicate whether the upper and lower limits
have been correctly set or not.
•If ‘ ’ is blinking…the upper and lower limits have
been set correctly.
•If ‘ ’ is blinking…the upper and lower limits have not
been set correctly.
Lower limit value 1_SL
Upper limit value 2_SL
Incident light
intensity of P-3.
Press the
Jog switch.
Incident light
intensity of P-2.
Press the
Jog switch.

4-4.
Threshold Value Fine Adjustment Mode [when using FX-301(P)(-HS) or FX-305(P) normal mode]
1Press the [MODE key] twice to select ‘threshold value fine
adjustment mode’.
2FX-305(P): Turn the [Jog switch] to select the desired ‘output’
for setting.
3If the [Jog switch] is pressed, the ‘output’will be set.
4The current ‘threshold value’will be displayed.
* The factory setting is;
FX-301(P): 40, FX-301(P)-HS: 80
FX-305(P) output 1: 80, FX-305(P) output 2: 120
5If the [Jog switch] is turned toward the ‘’or ‘’direction,
the ‘threshold value’will change and the new value will blink.
If an increased ‘threshold value’is desired,
turn the [Jog switch] toward the ‘’direction.
If a decreased ‘threshold value’is desired,
turn the [Jog switch] toward the ‘’direction.
* When using the FX-301(P) in LONG mode, it is
recommended that you set the threshold value to ‘15 digits’
or more.
7Press the [MODE key] 4 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’(normal
sensing operation).
6If the [Jog switch] is pressed, the digital display will quickly
blink 3 times, confirming the setting of the currently
displayed ‘threshold value’.
In case of
turning toward
the ‘’.
Turn the Jog switch to set the
desired threshold value.
In case of
changing
threshold value
to 35.
Turn the
Jog switch.
Press the
Jog switch.
Press the MODE key
4 times or keep it pressed
for 2 sec.or more.
Turn the Jog switch to select the
desired output.
Press the
Jog switch.
Output 1 Output 2
Press the
MODE key twice.
The digital display will quickly
blink 3 times to confirm the value.
This mode allows fine adjustment of the ‘threshold value’setting.
In case of FX-301(P)(-HS)
In case of FX-305(P)
The current
threshold
value
19
Other manuals for FX-301
1
This manual suits for next models
4
Table of contents
Other Sunx Amplifier manuals
Popular Amplifier manuals by other brands

thomann
thomann the t.amp E4-130 user manual

SINGTRONIC
SINGTRONIC KA-1000DSP user guide

Ehrhorn Technological Operations
Ehrhorn Technological Operations Alpha 77 PA-77 instruction manual

YORKVILLE
YORKVILLE DG10 Service manual

Axxera
Axxera MINI AX460D Installation & owner's manual

YORKVILLE
YORKVILLE AP1020 owner's manual