SUP’AIR BUMP STK2 User manual

SUPAIR SAS
PARC ALTAÏS
34 RUE ADRASTÉE
74650 ANNECY CHAVANOD
FRANCE
RCS 387956790
User’s manual
BUMP STK2
Indice de révision : V1 01/07/2021
English

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 2
Introduction 3
Presentation 4
Nomenclature 5
Operating principle 6
Installation in the harness 7
Use 10
Inflating the protection 10
Deflating the protection 11
Note 12
Maintenance 12
Cleaning and maintenance 12
Product longevity and warranty 12
Repair 13
Spare parts 13
Materials 13
Recycling 13
Shock Absorber 14
In case of incident 15
Service Book 16
LIST OF CONTENTS

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 3
Welcome to the world of paragliding according to SUPAIR, a world of shared passion.
The BUMP STK2 inflatable protection is an option for the STRIKE 2 hike&fly harness.
This option is particularly suitable for entering the world of light and performance!
This protection increases the damping characteristics of the STRIKE 2 and makes the harness more compact in the walking phase!
Originally designed for X-Alps pilots, it is intended for the hike & fly pilots looking for performance.
The design and choice of materials have been designed with the objective of comfort and lightness.
STRIKE 2 harness was certified EN 1651: 2018 and LTF Nfl II 91/09. Indicating that it meets European and German safety require-
ments.
The inflatable STK2 Bump has been designed for the Strike 2 and should only be used for the Strike 2.
After reading this manual, we suggest you to check your harness in static hang-posts to adjust it before your first flight.
The principle of this inflatable protection was the subject of a patent (INPI registration number 97 11915) by Pierre Bouilloux that we
filed in September 1997... and that we had not yet implemented. This patent being more than 20 years old, it has now fallen into the
public domain...
Introduction
N.B : Three important icons will help you when reading this manual :
Advice Caution ! Danger !!

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 4
GENERAL PRESENTATION

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 5
NOMENCLATURE
1
2
3
4
Pipe
Envelope
Inflatable pocket
3
4
2
1
Pull-push valve

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 6
OPERATING PRINCIPLE
The inflatable BUMP inflates by mouth and deflates as needed (carrying or flying).
The waterproof bag is structured with internal partitions to distribute pressure and overpressure (during an impact).
The fabric envelope reinforces the strength and prevents the waterproof bag from bursting during an impact.
A tube ending in a Pull-push valve allows the bag to be inflated or deflated. This action is done at the harness shoulder straps which makes it pos-
sible to inflate the protection when the pilot is in the harness at take-off (or in flight to adjust the pressure).

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 7
INSTALLATION IN THE HARNESS
1Open the zip of the under-seat pocket and open ( zip ) the BUMP
pocket
Once fitted, the inflatable BUMP doesn’t need to be removed from
the harness except for inspection and maintenance.
2Insert the Inflatable BUMP by first passing the pipe through the hole at the bottom of the pocket on the top right.
The passage (8mm diameter hole may be difficult to find)

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 8
3Pass the pipe on the left side of the harness between the backrest and the container (under the back
pocket)
4The pipe passes between the back plate pocket and the back pocket (visible by opening the horizontal zip in the back pocket). Pass
the tube through a new 8mm diameter hole into the back pocket.
INSTALLATION IN THE HARNESS

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 9
5Pull the pipe out of the back pocket through the left exit against the left shoulder strap of the harness
6Pass the pipe through the two elastic bands of the sling.
Don’t forget to close the BUMP pocket and pocket under the seat.
WARNING
INSTALLATION IN THE HARNESS
- The right side back pocket outlet is dedicated to the camel
back (the hose can be pulled out in case of emergency use)
and the left side outlet is dedicated to the inflatable protec-
tion. And not the reverse.
- Check that the tube is not twisted or pinched between the
bag and the mouthpiece, which can affect inflation in flight.

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 10
USE
INFLATE THE PROTECTION
Open the pull-push valve by pulling the movable nozzle towards you
Close the valve by pushing the nozzle towards the bag.
Inflate the bag by blowing directly into the tube. 5 long exhalations may be sufficient (depending on the pilots!).
The bag is correctly inflated when the pressure in the bag prevents further inflation (like a buoy, there is no need to force it).
1
3
2
OPEN
CLOSE

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 11
USE
DEFLATE THE PROTECTION
Pull the movable nozzle towards you Compress the harness on the protection to empty it of its air
1 2
WARNING
Don’t try to turn the valve. Risk of damaging the connection
with the pipe.
The only movements you need to do are pulling or pushing the
nozzle.
OPEN

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 12
What is the influence of the pressure of the protection on the damping performance?
This is difficult to establish precisely. Here is what we can say:
For the standard test: The protection is inflated and tested at the same altitude with a “normal” full inflation pressure at the mouth without
forcing.
At an altitude higher than the take-off altitude, i.e. higher than the inflation altitude, the pressure in the protection increases. Supair’s tests
show a stable shock absorption quality compared to the test conditions.
At an altitude lower than the take-off altitude, and therefore lower than the inflation altitude, the pressure in the protection decreases. We
have tested the half-inflated bag and the result shows that the impact performance is still within the standard, but with lower values than
those measured when the protection is fully inflated.
It is therefore recommended that, after losing a significant flight altitude in relation to the take-off altitude, you reinflate the protection in
flight using the mouthpiece (left, see page 9)
NOTE
Influence of the pressure in the protection on the performance of the damping
Clean the BUMP envelop with water.
For the valve: clean with water and washing-up liquid.
In all cases, do not use thinner or solvent as this could damage the fibres that make up the fabric of your protection.
Cleaning and maintenance
Life span and warranty
This protection is guaranteed for two years. This protection can be used for up to 5 years if there is no air leakage from the pocket and if the
fabric cover is not damaged.
CARE

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 13
We have minimized our manufacturing footprint by carefully selecting environmentally friendly materials; most of our components are recyclable.
If you estimate that your BUMP STK2 has reached the end of it life span, you can separate plastics from metals and recycle them according to your
community rules in effect. As for the fabric itself, contact your local authorities to find out how to proceed to discard it.
Possible on the fabric envelop.
If the air pocket or the valve or the pipe are damaged it is necessary to replace the entire protection.
Repair
Hardware & Parts
Materials
Recycling
There is no spare part for this approved protection and safety product.
The pocket is in PU 300 micron, neutral anti-mold material.
The envelope is made of 210 D ripstop nylon fabrics
CARE

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 14
Shock Absorber
The harness you have just purchased has a BUMPAIR type shock absorber.
This protection is intended to protect you against potential impacts. It complies with EU Regulations 2016/425 relating to personal protective equip-
ment (PPE) and certified by expert following protocol SP-002 12/2016.
The shock absorber UE conformity of your harness is certified by the following laboratory: ALIENOR CERTIFICATION n ° 2754, Z.A. du Sanital, 21 Rue
Albert Einstein, 86100 Chatellerault, FRANCE
Please note that no shock absorber can guarantee total protection against injury. The back protector does not prevent potential injuries
to the spine and/or pelvis. In addition, only the parts of the body covered by the shock absorber are likely to benefit from adaquate protec-
tion against possible impacts.
If your BUMPAIR is damaged, have it inspected and repaired at a professional qualified facility or contact us at sav@supair.com
Please note that the performance of the equipment can be dangerously affected by any mod-
ification made or improper use of the shock absorber, and negatively affect the proper func-
tionality of the protector which must be whole and properly installed. You must check that all
is in order prior each flight:
-The correct installation of the BUMPAIR shock absorber.
-The BUMPAIR seams and overall condition of the fabrics - look for holes, tears, snags ....
The protection can have a five (5) year lifespan under normal use conditions.
Warning! Following a major hard landing would justify the protector to be discarded.
The test results and the EU declaration of conformity can be found at: www.supair.com
Label meaning :
Nom du produit / Name of the product :
Entretien / Maintenance :
Date de production / Date of production :
30°C
Taille / Size :
Conform to the EPI requirements.

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 15
IN CASE OF AN INCIDENT
112EUROPE / INDIA
911
USA / CANADA
119CHINA / JAPAN
101NEPAL
112IRAN
000AUSTRALIA
111NEW ZEALAND
Help needed?
Call for help after an accident
Emergency call
numbers
YES NO
Flashlight SOS :

User’s manuel | BUMP STRIKE 2
SUPAIR | BUMP STRIKE 2 | page 16
SERVICE BOOK
This page will help you keep record of your BUMP STK2 scheduled maintenance.
Purchase date
Owner’s name :
Name and stamp of the shop :
Care
Resale
Date
Workshop’s name/ Buyer’s name
Care
Resale
Date
Workshop’s name/ Buyer’s name
Care
Resale
Date
Workshop’s name/ Buyer’s name
Care
Resale
Date
Workshop’s name/ Buyer’s name

SUPAIR-VLD
Parc Altaïs
34 rue Adrastée
74650 Chavanod, Annecy
FRANCE
info@supair.com
+33(0)4 50 45 75 29
RCS 387956790
Table of contents
Other SUP’AIR Sport & Outdoor manuals

SUP’AIR
SUP’AIR EVEREST3 User manual

SUP’AIR
SUP’AIR RADICAL 4 User manual

SUP’AIR
SUP’AIR EVO LITE User manual

SUP’AIR
SUP’AIR FLUID User manual

SUP’AIR
SUP’AIR MINIMAX BUMP User manual

SUP’AIR
SUP’AIR DELIGHT 4 SPORT User manual

SUP’AIR
SUP’AIR LOUSTIC 2 User manual

SUP’AIR
SUP’AIR DELIGHT M User manual

SUP’AIR
SUP’AIR Delight2 User manual

SUP’AIR
SUP’AIR FLUID LIGHT EVO User manual