4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
TABLE OF CONTENTS
Safety and Your Fireplace......................... Page 2
Packaging ................................................Page 4
Introduction .............................................Page 4
General Information.................................Page 4
Commonwealth of Massachusetts
Requirements.......................................Page 6
Cold Climate Insulation............................Page 7
Manufactured Home Requirements .........Page 7
Location...................................................Page 7
Vent Termination Clearances ...................Page 8
Appliance and Vent Clearances ................Page 10
Pre-Installation Steps............................... Page 11
Typical Installation Sequence ..................Page 11
Step 1. Framing........................................Page 11
Step 2. Routing Gas Line .........................Page 13
Step 3. Vent Restrictor Installation...........Page 14
Step 4. Install The Venting System ..........Page 15
Vertical Termination Systems................... Page 16
Horizontal Termination System ................Page 21
Step 5. Field Wiring.............................. Page 27
Step 6. Optional Blower Kit Wiring .......Page 28
Step 7. Connecting Gas Line ................Page 28
Step 8. Verifying Appliance Operation......Page 29
Step 9. Installing Logs .........................Page 30
Step 10. Remove/Install Glass Door ......Page 32
Step 11. Burner Adjustments ................. Page 32
Step 12. Attaching Safety-in
Operation Warnings ..............................Page 34
Step 13. Hood Installation......................Page 35
Finishing Requirements ...........................Page 35
Installation Accessories ...........................Page 36
Gas Conversion Kits................................Page 37
Important Safety Information...................Page 39
Installation, Service, And Maintenance
Notices.................................................Page 41
Appliance Operation Notices ...................Page 41
General Information.................................Page 41
Operation/Care of Your Appliance ............Page 43
Gas Controls Access................................Page 43
Variable Flame Adjustment.......................Page 44
Maintenance ............................................Page 45
Front Glass Enclosure Panel, Barrier,
Removal and Installation ..................... Page 46
Install Volcanic Stone, Embers and Logs.Page 47
Burner Flame Appearance/Sooting and
Adjustments.........................................Page 49
Wiring Diagrams .....................................Page 51
Accessory Components ........................... Page 52
Maintenance Schedule.............................Page 55
Lighting Instructions................................Page 56
Troubleshooting Guide ............................Page 60
Replacement Parts List ...........................Page 62
Warranty .................................................Page 65
Please read and understand these
instructions before beginning your
installation.
PACKAGING
The assembled vented gas fireplace heater is
packaged with:
1 - logs in a carton located within the firebox.
2 - one plastic bag of glowing embers in the
bottom compartment.
3 - literature package containing the Installa-
tion and Operation Manual (this manual),
Safety Flyer, Glass and Barrier Flyer and
Safety-in-Operation Warning Labels.
4 - one rear and one top vent restrictor are
provided with this fireplace. See Page 14
for installation instructions.
5 - one hood.
6 - front face assembly with barrier installed.
7 - 4" top stand off taped diagonally to the rear
of the fireplace.
INTRODUCTION
The Millivolt appliances have a millivolt gas
control valve with piezo ignition system. If any
optional accessories that will require electrical
power are to be installed, the electrical power
mustbeprovided atthetime ofapplianceinstal-
lation.TheElectronic appliancesaredesignedto
operateonnaturalorpropanegas.Anelectronic
intermittentpilot ignition system provides safe,
efficient operation. External electrical power is
required to operate these units.
These vented gas fireplace heaters are sealed
combustion, air-circulating gas fireplaces de-
signed for residential applications.
Approved Vent Components - These fireplaces
are designed, tested and listed for operation
and installation with the following vent com-
ponents only:
•Secure Vent®Direct-Vent System Compo-
nents manufactured by IHP,
• ®Flexible Vent Components
manufactured by IHP and
•Z-FLEX®Model GA Venting Systems listed
to UL1777 and ULCS635 manufactured by
Flexmaster Canada Limited.
Use only the correct size venting (4-1/2" inner
and 7-1/2" outer).
These approved vent system components are
labeled for identification. DO NOT use any
other manufacturer’s vent components with
these appliances.
NOTE:
-
-
barrier for this appliance.
Children and adults should be alerted to the
hazards of high surface temperature and
should stay away to avoid burns or clothing
ignition.
Les enfants et les adultes devraient être infor-
mésdes dangers queposent les températures
de surface élevées et se tenir à distance afin
d’éviter des brûlures ou que leurs vêtements
ne s’enflamment.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING
Young children should be care-
in the same room as the appli-
and others may be susceptible
to accidental contact burns. A
physicalbarrierisrecommended
if there are at-risk individuals in
the house. To restrict access to
adjustable safety gate to keep
other at-risk individuals out of
surfaces.
AVERTISSEMENT
Lesjeunesenfantsdevraientêtre
surveillésétroitementlorsqu’ils
se trouvent dans la même pièce
lesjeunesenfantsoulesadultes
peuvent subir des brûlures s’ils
viennent en contact avec la sur-
facechaude. Ilestrecommandé
d’installerunebarrièrephysique
-
tent la maison. Pour empêcher
installez une barrière de sécu-
surfaces chaudes.
GENERAL INFORMATION
Installation and Operation Instructions
900357-00, 09/2015
Innovative Hearth Products
DRT4000 Direct Vent Gas Fireplace