superior pump 92581 User manual

8
OWNER’S MANUAL
INSTALLATION AND
OPERATION INSTRUCTIONS FOR
SUBMERSIBLE SUMP/EFFLUENT PUMP
Model:
92581, 92571
92731, 92751
92181, 92151
2
7
Ref# Description Part #
1 Power Cord 99102
2 Oil Fill Plug with O-ring 99056
3 Pump Housing Cover 99166
4 Gasket 99162
5 Shaft Seal 99157
6 Impeller 99152
7 Volute/Base 99165
8 Intake Screen 99163
9 Vertical Float Switch 92010
10 Vertical Float Switch Bracket 99104
11 2” MNPT x 1-1/2” MNPT Adapter 99250
12 Tethered Float Switch 92000
REPLACEMENT PARTS
To order replacement parts call
6
NOTICE !Height and/or piping restriction will reduce the pump output performance. See the
performance chart below to insure you have the proper pump for your application. Whenever
possible use the same size or larger pipe as the pump discharge for optimum performance.
Reducing the pipe size will not harm your pump; it will just reduce the output.
PERFORMANCES
Model
#
Output in gallons per minute at listed discharge
Height above pumping level
0’ 5’ 10’ 15’ 20’ 25’ 30’ 35’ 40’ 45’
92581
92571 75 70 64 57 49 40 31 21 11 0
92731
92751 80 75 69 61 55 45 38 25 16 2
92181
92151 86 81 75 68 61 52 43 31 20 3
SPECIFICATIONS
Power supply requirements 120V, 60 Hz
92581, 92571 Motor 1/2 HP, Continuous Duty,
Split Capacitor
92731, 92751 Motor 3/4 HP, Continuous Duty,
Split Capacitor
Thermally Protected
92181, 92151 Motor 1 HP, Continuous Duty,
Split Capacitor
Thermally Protected
Amps 7.5
Liquid Temperature Range 32° F - 120° F (0° C - 49° C)
Circuit Requirements 15 amp minimum
Solids Handling 1/2”
Discharge Size 2” NPT
Warranty 3 Years
3
4
USE AND INSTALLATION
Always disconnect the power source before attempting to install, service or
perform maintenance on the pump. Failure to do so may result in fatal
electrical shock. Always disconnect the power source before servicing pump.
Your Superior Pump is designed and built to give you reliable performance and long life. It will
pump water automatically for years when properly installed in the right environment.
REMOVING OLD PUMP. (If necessary)
1. Make sure power supply is disconnected.
2. After the power is off, remove the old pump. There are many different possible types of
installations. It is best to remove all old piping and start over with new piping. Be sure to clean all
debris and dirt out of the sump basin before installing your new pump. Be sure to have a
grounded 120V AC outlet mounted within 6 ft. of your sump basin. Again, it is highly
recommended that a GFCI (ground fault circuit interrupter) outlet be installed in the receptacle
box.
NOTICE !
A qualified electrician must perform all wiring.
INSTALLATION (New Pump)
1. Set your new pump in the bottom of the sump basin off to one side. The pump should be
placed on a solid foundation. Do not place the pump directly on the ground or sandy or
rocky surfaces. Sand and small stones may clog or cause damage to your pump.
2. Make sure the float switch will swing freely from the bottom to top without coming in contact
with the side of the sump basin. Contact with the side of the sump basin may cause the
switch to malfunction. See figure below.
3. It is highly recommended to install a full flow, swing type check valve (not included) as close
to the discharge outlet on the pump as possible. A new check valve will greatly increase the
life of your pump. The check valve should be the same size as the pump discharge.
A. Grounded Outlet. A GFCI outlet is
strongly recommended.
B. Discharge Pipe
C. Full-flow swing type check valve
D. Sump Basin
E. Position pump so the float switch
operates freely without touching the
sides of the basin.
5
4. Connect the pump and check valve together using schedule 40 PVC pipe and fittings.
You can also use DWV or ABS pipe, as this is not a pressure installation. Corrugated
drain hose is intended for temporary use and should not be used in a permanent
installation. Although there are many types of pipe that work adequately for this
installation, PVC is recommended.
5. Test your installation after you have completed setting up the pump. Plug the cord from
the pump into the piggyback plug of the float switch, then plug that into your grounded
outlet. The pump should not run at this point. If the pump runs, the switch is stuck in the
upright position or the pump is plugged directly into the outlet and not through the
piggyback switch plug. Fill the sump basin with water using buckets or a hose. When the
switch floats to the upright position, the pump will turn on. The switch will turn off the
pump when it reaches the down position. You may adjust the switch to meet your
particular needs. Remember the switch must swing freely without touching the sides of
the sump basin.
NOTE: This pump has a built in anti-airlock device. Leakage is normal from this device.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSES HOW TO CORRECT
If the pump does
not start or run
Pump is not plugged in, switch or breaker is off Plug pump in or turn on switch/breaker
Check for blown fuses or tripped circuit breakers or
tripped GFCI outlets Replace fuse, reset breaker, reset GFCI outlet
Float switch is defective Check and replace if necessary
Motor thermal protector tripped Allow pump to cool. Pump will reset
Float switch is stuck or obstructed Remove obstruction or position pump so it will not
become stuck
The pump starts
and stops too often
Backflow of water from discharge hose/pipe Install or replace check valve
Float switch is defective Replace float switch
If the pump runs
but moves little or
no water
Clogged intake screen Clean or replace screen
Clogged discharge hose/pipe Remove clog
Frozen discharge hose/pipe Allow hose/pipe to thaw
Pump is air locked Clean out airlock hole with a paper clip or pipe cleaner
Low line voltage Check wire size and increase if necessary
Check valve is stuck in the closed position Inspect, repair or replace if necessary
Check valve is installed backwards Make sure valve is installed in the correct direction of
flow
Worn, damaged or clogged pump parts Inspect for wear, damage or clog and clean or replace
if necessary
Discharge head exceeds pump capacity If pumping height is over 25’, the pump will not move
water. See performance chart
Pump does not
shut off
Float switch is obstructed or stuck Remove obstruction
Defective Float Switch Replace switch

This manual suits for next models

5

Other superior pump Water Pump manuals

superior pump 94505 User manual

superior pump

superior pump 94505 User manual

superior pump 92570 User manual

superior pump

superior pump 92570 User manual

superior pump 90084 User manual

superior pump

superior pump 90084 User manual

superior pump 92900 Owner's manual

superior pump

superior pump 92900 Owner's manual

superior pump 91025 User manual

superior pump

superior pump 91025 User manual

Popular Water Pump manuals by other brands

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Watershed Innovations

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Graco Modu-Flo AL-5M instructions

Graco

Graco Modu-Flo AL-5M instructions

Messner MultiSystem MPF 3000 operating instructions

Messner

Messner MultiSystem MPF 3000 operating instructions

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

Xylem

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

WilTec 50739 Operation manual

WilTec

WilTec 50739 Operation manual

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Franklin Electric

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Ingersoll-Rand PD02P Series Operator's manual

Ingersoll-Rand

Ingersoll-Rand PD02P Series Operator's manual

VS ZJ Series Operating	 instruction

VS

VS ZJ Series Operating instruction

Flotec FPZS50RP owner's manual

Flotec

Flotec FPZS50RP owner's manual

SKF Lincoln FlowMaster II User and maintenance instructions

SKF

SKF Lincoln FlowMaster II User and maintenance instructions

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Xylem

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Water Duro Pumps DCJ500 Operating & installation instructions

Water

Water Duro Pumps DCJ500 Operating & installation instructions

Action P490 Operating instructions & parts manual

Action

Action P490 Operating instructions & parts manual

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

Flo King

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

ARO ARO PD15P-X Operator's manual

ARO

ARO ARO PD15P-X Operator's manual

Pumptec 112V Series Operating instructions and parts manual

Pumptec

Pumptec 112V Series Operating instructions and parts manual

Virax 262070 user manual

Virax

Virax 262070 user manual

Neptun NPHW 5500 operating instructions

Neptun

Neptun NPHW 5500 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.