SurgiTel ErgoVision FLM User manual

Remember that the hinge
tension is adjustable by
adjusting the center tension
screw on the hinge.
 To achieve the optimum
resolution and field size,
make sure that the telescope
oculars are touching the
frame's lens.
Doc No. 23822Q
SurgiTel
ErgoVision®
Front-Lens-Mounted (FLM) Telescopes
USER INSTRUCTIONS
►Thank you for choosing SurgiTel®!
Your SurgiTel®telescopes have been designed to meet the demanding needs
of today’s clinical professionals. Please keep in mind that you will have
a hand-eye coordinaon adjustment period of about two weeks. Begin
slowly with simple movements, working your way up to more complicated
procedures. In the end, SurgiTel®telescopes will allow you to see, work, and
feel your best.
►GETTING STARTED
1
2
3
4
Remove protection caps.
Adjust nose pads.
Adjust your pupillary distance knob
to a comfortable setting where the
two images converge together. (see
Adjusting P.D. (Pupillary distance)
section)
Move your frame slightly away
from face/eyes to minimize fogging.
5
6Adjust the tension in the hinge to a
comfortable setting. (see Adjusting
Flip-up Tension section) Make sure
to add slightly more tension when
using a clip-on light.
Position your oculars against the
frame lens to maximize field size.
Starting Magnification Tips
 A new or upgraded user to magnicaon will experience a normal
“adjustment” period.
 This is normal as you are adjusng to using your new loupes on two levels:
 Hand/Eye Coordinaon – geng used to working with a magnied eld.
 Improved Posture – geng used to sing more upright.
 For the 1 Week: Begin by working for 1-2 hours in the morning on simple
procedures.
 For the 2 Week: Gradually work your way to more complex procedures,
both in the morning and aernoon.
 Also, do not walk around with your telescopes on. Be sure to take them o
when walking around.
®
SurgiTel®
a division of General Scientific Corporation
77 Enterprise Drive • Ann Arbor, MI 48103-9503
E-mail inf[email protected] • www.surgitel.com
►SETTINGS/ADJUSTMENT
All SurgiTel®telescopes are factory set to the users specicaons. If minor
adjustments are necessary for change in preference(s) follow the steps below.
1. Loosen the slide retainer screw that allows you to adjust the V.P. (vercal
posion). (g 1)
2. Place the loupes at the lowest posion on the frame, then slowly raise
upward unl you achieve a comfortable ocular height. To hold V.P., make
sure the slide retainer screw is ghtened. (g 1)
3. Adjust the declinaon angle by moving the ocular rack unl your preferred
head lt is achieved. Then adjust the ocular rack to aain your line of
sight. (g 6)
4. Tighten all hinge screws with hex key (add slight tension) once you have
found your comfortable declinaon angle and alignment.
5. Posion yourself into your working posion and adjust the P.D. (pupillary
distance) knob (g 3) unl you have one image in an oblong/oval shape.
(g 4)
►ADJUSTING V.P. (VERTICAL POSITION)
1. Loosen the slide retainer screw that allows the slide retainer to move up/
down. (g 1)
2. Posion the loupes on your face/nose.
3. Adjust the oculars unl oculars are aligned to the eyes.
4. If oculars are not moved enough to align, remove loupes from your face to
adjust. Remove slide retainer screw and change placement. For screw
placement guidance refer to g 2.
Low nose
Medium nose
High nose
fig 1 fig 2
►ADJUSTING FLIP-UP TENSION
• Top Locking Screw
The whole loupe system can be ipped up to
open up your line of sight by simply rotang
link-hinge upwards (g 5). If you ip-up your
loupes frequently, leave this screw a lile
loose.
• Boom Locking Screw
Allows adjustment and locking of declinaon
angle (g 6). Maintains angle while ipped-
up or ipped-down. If you use your loupes at
dierent working postures, you should leave
this screw loose and allow the middle tension
screw to hold it in place.
• Middle Tension Screw
The level of ipping tension can be adjusted by
ghtening the middle screw. Tighten or loosen
the center screw so that the ip-up tension is
acceptable.
*Note: This hinge system is designed to work with the middle tension screw. The
top and boom screws are used for locking purposes.
fig 6
fig 5
►ADJUSTING P.D. (PUPILLARY DISTANCE)
1. Posion the loupes on your face and nose.
2. Using the P.D. knob (g 3), spread the oculars apart to the widest distance.
3. When looking through the oculars, focus on an object in front of you (such as
your thumb). If it is not in focus, move your thumb/object towards or away
from you unl you see it clearly.
4. With the other hand slowly adjust the P.D. knob unl you have one image in
an oblong/oval shape. (g 4)
Adjust pupillary (P.D. Knob) to a comfortable
setting where two images converge together.
(
fig 3,4)
fig 4
fig 3
Optimal/Preferred
Pupillary Adjustment
►CLEANING & DISINFECTION
FACTORY REFURBISHMENT CLEANING: is available if you come across a dicult
cleaning situaon. Call customer support for details: 800-959-0153
►ADJUSTING NOSE PAD(S)
When the nose pads are properly adjusted to your face, they will provide excel-
lent comfort and balance. If the nose pads do not make even contact with your
nose comfortably, please follow the direcons described below.
DO CLEAN:
Use quaternary ammonium
compounds is ok. Dry thoroughly.
For full list of recommended
disinfectants, visit www.surgitel.com/
help
Any cleaners with alcohol,
ethanol, ammonia,
glutaraldehydes, iodophors
Rinse Under Running Water
Submerge in Water or
Any Liquid
Autoclave
DO NOT USE: DO NOT:
Use eyeglass cleaners (without
alcohol), hydrogen peroxide
or apply mild soap and water
with a soft cloth until particles
are loosened. Wipe or air dry.
DO DISINFECT:
SurgiTel’s mission is to provide the best products for your Vision & Ergonomics
at Work. To support this commitment SurgiTel®warranties all of its products.
SurgiTel®strives to make the best loupes and light systems available. Please
inspect and try on product immediately upon receipt. If you notice any issues,
contact our customer service department at 800-959-0153.
For both warranty and out-of-warranty issues, contact SurgiTel® Customer
Service regarding repairs.
Warranties vary by product. Check www.surgitel.com/warranty for more details.
Check www.surgitel.com/help for up to date care information/instructions.
Please keep up to date on care information/instructions, as warranties can be
affected if product is misused.
►PATENT
U.S. Patent Numbers: US 7,791,798; US 8,913,318; US D649,571; US 8,964,292;
US 9,465,235; US D746,354; US 9,383,077; US 7,719,765, US 9,494,299, US
8,068,169, etc.
►WARRANTY
• Adjusng Nose Pads for Too
High Oculars
Adjust the width of the nose pads
by bending the nose pad wire
mounts outwards (g 7). By doing
so, this will reduce the height of
the frame and lower the ocular
posion.
• Adjusng Nose Pads for Too
Low Oculars
Adjust the width of the nose pads
by bending the nose pad wire
mounts inwards (g 8). By doing
so, this will increase the height
of the frame and raise the ocular
posion.
• Adjusng Nose Pads for Low
Nose
If the nose pads are not evenly
placed on the bridge of the nose,
bend the wire mounts down and
away from the frame (g 9) and
readjust the width of the nose
pads if necessary. Note that the
wire mount lt angle depends on
the bridge of the nose. The less
nose bridge you have, the larger
the lt becomes to t your nose.
fig 7
fig 8
fig 9
fig 7
fig 8
fig 9
How to adjust nose pad to t nose

Other SurgiTel Telescope manuals

SurgiTel Odyssey Wireless LED User manual

SurgiTel

SurgiTel Odyssey Wireless LED User manual

SurgiTel ErgoVision User manual

SurgiTel

SurgiTel ErgoVision User manual

SurgiTel ErgoVision User manual

SurgiTel

SurgiTel ErgoVision User manual

SurgiTel ErgoVision TTL User manual

SurgiTel

SurgiTel ErgoVision TTL User manual

SurgiTel ST250 User manual

SurgiTel

SurgiTel ST250 User manual

SurgiTel SurgiCam HD User manual

SurgiTel

SurgiTel SurgiCam HD User manual

SurgiTel Odyssey LED User manual

SurgiTel

SurgiTel Odyssey LED User manual

Popular Telescope manuals by other brands

SKY-WATCHER 1501EQ5 instruction manual

SKY-WATCHER

SKY-WATCHER 1501EQ5 instruction manual

SKY-WATCHER DOB6 instruction manual

SKY-WATCHER

SKY-WATCHER DOB6 instruction manual

Celestron Ultima 9 1/4 installation guide

Celestron

Celestron Ultima 9 1/4 installation guide

ORION TELESCOPES & BINOCULARS SKYVIEWPRO 6LT EQ 9872 instruction manual

ORION TELESCOPES & BINOCULARS

ORION TELESCOPES & BINOCULARS SKYVIEWPRO 6LT EQ 9872 instruction manual

Celestron Cometron FirstScope 76 Quick setup guide

Celestron

Celestron Cometron FirstScope 76 Quick setup guide

Levenhuk Skyline 70x900 EQ user manual

Levenhuk

Levenhuk Skyline 70x900 EQ user manual

Leica 82 HD Specifications

Leica

Leica 82 HD Specifications

cassini C-JRS operating instructions

cassini

cassini C-JRS operating instructions

Onstep GOTO quick start guide

Onstep

Onstep GOTO quick start guide

Zhumell ECLIPSE 114 owner's manual

Zhumell

Zhumell ECLIPSE 114 owner's manual

Zhumell Kepler user guide

Zhumell

Zhumell Kepler user guide

TMB Optical TMB-80 instruction manual

TMB Optical

TMB Optical TMB-80 instruction manual

AstroMedia 209.NST instructions

AstroMedia

AstroMedia 209.NST instructions

Saxon 909EQ2 instruction manual

Saxon

Saxon 909EQ2 instruction manual

Celestron CPC Series instruction manual

Celestron

Celestron CPC Series instruction manual

Celestron FirstScope 76EQ Quick setup

Celestron

Celestron FirstScope 76EQ Quick setup

ORION TELESCOPES & BINOCULARS GoScope II Operating and assembly manual

ORION TELESCOPES & BINOCULARS

ORION TELESCOPES & BINOCULARS GoScope II Operating and assembly manual

Vixen VC200L brochure

Vixen

Vixen VC200L brochure

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.