SUS SiO User manual

SiO Controller SiO2/SiO2PNP
SiO3
SiO-N1
SiO3.2
SiOt
SiO-N3/SiO-N3PNP
Instruction Manual
Version 3.9

Scope of Warranty
Warranty Period One year from purchase
1. The warranty period for this product is one year from the purchase date.
SUS will repair free of charge any failure due to defects in workmanship.
However, SUS will only offer carry-in service at our factories.
2. Even within the warranty period, the following cases shall not be covered by the
warranty.
a. Failure due to improper handling or use not based on the instruction manual
b. Failure due to electrical or mechanical modification
c. Failure or damage caused by fire, earthquake, or other natural disaster
d. Any other failure or damage for which SUS is not considered responsible
3. This warranty is valid only in Japan.
4. The warranty covers only the delivered product and does not cover any other damage
resulting from failure of the product.
SUS Corporation
http://www.sus.co.jp/
Contact the Snets sales office for inquiries.
53 Nishikata, Kikugawa-shi, Shizuoka
439-0037, Japan, Phone: 0537-28-8700
Prices, specifications, and dimensions are subject to change without prior notice for product
improvement.
Oct 2021, Version 3.9

SiO Controller
Contents
1. Introduction........................................................................................1-1
1. 1 Accessories.......................................................................................... 1-1
1. 2 Precautions for Safe Use ..................................................................... 1-2
1. 3 Compliance with EC Directive.............................................................. 1-2
2. Overview.............................................................................................2-1
3. Functions............................................................................................3-1
3. 1 Part Names and Functions................................................................... 3-1
3. 1. 1 SiO2/SiO2PNP .................................................................................3-1
3. 1. 2 SiO3..................................................................................................3-2
3. 1. 3 SiO-N1..............................................................................................3-3
3. 1. 4 SiO3.2...............................................................................................3-4
3. 1. 5 SiOt...................................................................................................3-5
3. 1. 6 SiO-N3/SiO-N3PNP..........................................................................3-6
3. 2 Principle of Operation................................................................................3-7
3. 2. 1 Program............................................................................................3-7
3. 2. 2 Cycle Time........................................................................................3-8
3. 2. 3 Input Response Time........................................................................3-8
3. 3 Installation............................................................................................ 3-9
3. 3. 1 Installation of Controller....................................................................3-9
3. 3. 2 Wiring to Controller...........................................................................3-9
3. 4 Settings ................................................................................................ 3-10
3. 4. 1 RUN Switch ......................................................................................3-10
3. 4. 2 Timer Setting.....................................................................................3-10
3. 5 Input/Output .......................................................................................... 3-11
3. 5. 1 Input/Output Connectors (SiO2/SiO2PNP).......................................3-11
3. 5. 2 Input/Output Connectors (SiO3) .......................................................3-12
3. 5. 3 Input/Output Connectors (SiO-N1)....................................................3-13
3. 5. 4 Input/Output Connectors (SiO3.2) ....................................................3-14
3. 5. 5 Input/Output Connectors (SiOt) .......................................................3-15
3. 5. 6 Input/Output Connectors (SiO-N3/SiO-N3PNP) ..............................3-16
3. 5. 7 Input Circuit Specifications................................................................3-17
3. 5. 8 Output Circuit Specifications.............................................................3-18
3. 5. 9 Examples of Input/Output Connection (SiO2/3/N1/3.2/t/N3).............3-19
3. 6 About Ethrnet communication.................................................................3-20
4. SiO-Programmer............................................................................................4-1
5. Options ...............................................................................................5-1
6. Troubleshooting.................................................................................6-1
7. Specifications.....................................................................................7-1

SiO Controller
SUS Corporation
1-1
1. Introduction
Thank you for purchasing the SiO controller.
This instruction manual describes in detail how to handle and operate the product. Read this manual
carefully and use the product properly.
After installation, keep this manual beside the product and make sure that everyone who handles the
product regularly refers to it.
This manual is for the SiO controller (SiO2/SiO2PNP/SiO3/SiO-N1/SiO3.2/SiOt/SiO-N3/SiO-N3PNP).
When using the SiO-C controller, see the “SiO-C Instruction Manual.”
The contents of this manual are subject to change without prior notice for product improvement.
For the latest information, visit the SUS website (http://www.sus.co.jp/).
1.1 Accessories
When the product is delivered, check the accessories.
SiO controller Instruction manual (simplified version)
This product consists of the controller you have purchased among the following ones
and an instruction manual (simplified version).
•SiO2/SiO2PNP •SiO3 •SiO-N1
・SiO3.2 ・SiOt ・SiO-N3/SiO-N3/PNP
Not supplied with SiO3.2

SiO Controller
SUS Corporation
1-2
1.2 Precautions for Safe Use
Read the following precautions for safe use carefully and use the product properly.
The following precautions are intended to prevent harm to customers and others as well as
damage to property.
WARNING
In principle, handling and operating the product in any way not described in this manual
should be regarded as “prohibited.”
Take sufficient safety measures to ensure that the entire system works safely even in the
event of controller failure, signal line disconnection, or instantaneous power failure.
The product cannot be used for equipment that may affect a human life.
When working on the product, be sure to turn OFF the power before starting work.
Do not touch the controller with wet hands. Doing so may cause an electric shock.
Install the controller on an incombustible object. Failure to do so may cause a fire.
Be sure to apply each connector with the voltage specified for the connector.
Also, connect each connector with the correct polarity.
Do not disassemble or modify the controller.
CAUTION
The controller is a precision instrument. Do not drop it or give it a strong impact.
When disposing of the controller, treat it as general industrial waste.
1.3 Compliance with EC Directive
SUS has confirmed that the products listed below meet the mandatory requirements of the EC
Directive.
The compliance tests have been conducted by a third party, and products that meet the
compliance standards are marked with a certification mark on the case.
Instrument
Model
EC directive
Standards
SiO controller
SiO2
SiO2PNP
SiO3
SiO-N1
SiO3.2
SiOt
SiO-N3
SiO-N3PNP
EMC Directive
2014/30/EU
EN61326-1:2013
Certification mark
Indicates a serious danger that may lead to death or serious injury.
Indicates a danger that may lead to injury or damage to property.
!
WARNING
!
CAUTION

SiO Controller
SUS Corporation
2-1
2. Overview
The SiO controller is a compact, programmable input/output controller.
It allows the user to set conditions for turning ON and OFF each output using a simple selection type
programmer.
Model Input/Output How to install
Input Output Type Connector
SiO-C-G 8 8 NPN
Flat cable connector
GF (N)
SiO-C-D 8 8 NPN
Flat cable connector
DIN rail
SiO-C-P 8 8 NPN
Flat cable connector
Screw mount
SiO2 6 4 NPN e-CON GF (N) / DIN rail
SiO2PNP 6 4 PNP e-CON GF (N) / DIN rail
SiO3 16 16 NPN e-CON GF (N) / DIN rail
SiO-N1 8 8 NPN e-CON GF (N) / DIN rail
SiO3.2 3 2 NPN e-CON GF (N)
SiOt 4 2 NPN e-CON GF (N) / DIN rail
SiO-N3 16 16 NPN e-CON GF (N) / DIN rail
SiO-N3PNP 16 16 PNP e-CON GF (N) / DIN rail
* See “7. Specifications” for details of each controller.
For SiO-C controllers, see the “SiO-C Instruction Manual.”
Basically, SiO controllers are used as connected with input and output
devices as shown below. Also, the operating condition is registered by
connecting a personal computer via USB.
etc. etc.
Output device
Input device
Basic configuration
SiO controller
AC adapter
* Option
Push button switch
Photoelectric sensor
Proximity sensor
LED
Buzzer
Relay
+ USB cable * Option
Personal computer
Register programs
Input
Output
SiO controller model list

SiO Controller
SUS Corporation
3-1
3. Functions
3.1 Part Names and Functions
This section describes the part names, functions, and applications of SiO controllers
(SiO2/SiO2PNP/SiO3/SiO-N1/SiO3.2/SiOt/SiO-N3/SiO-N3PNP).
3.1.1 SiO2/SiO2PNP
No.
Part Function
(1) Power connector Connect an AC adapter here to supply 24 V DC.
* Do not supply power from other connectors.
(2) Power LED (green) Lights when the power is ON.
(3) RUN switch Set this to RUN (right) to execute the program.
(4) RUN LED (green) Lights during RUN.
(5) Input connectors A connector used for input (e-CON (4-pole) ×6 inputs)
(6) Output connectors A connector used for output (e-CON (3-pole) ×4 outputs)
(7) IN LED (red) Lights when the input signal is ON (I1 to I6).
(8) OUT LED (green) Lights when the output signal is ON (O1 to O4).
(9) USB connector Connect the USB cable here (Micro-B USB 2.0).
(10)
T1 Sets Timer 1.
(11)
T2 Sets Timer 2.
(12)
Ground terminal Connect this to the earth using an M3×4 screw.
(13)
AL LED (red) Not used
(14)
GF mount hook A hook for installation on a GF (N) rail.
(2)
(10)
(12)
(9)
(3)
(4)
(13)
(11)
(7)
(5)
(6)
(8)
(1)
Version label
* The same applies
to SiO2PNP.
(14)

SiO Controller
SUS Corporation
3-2
3.1.2 SiO3
No.
Part Function
(1) Power connector Connect an AC adapter here to supply 24 V DC.
* Do not supply power from other connectors.
(2) Power LED (green) Lights when the power is ON.
(3) RUN switch Set this to RUN (right) to execute the program.
(4) RUN LED (green) Lights during RUN.
(5) Input connectors A connector used for input (e-CON (4-pole) ×16 inputs)
(6) Output connectors A connector used for output (e-CON (3-pole) ×16 outputs)
(7) IN LED (red) Lights when the input signal is ON (IN1 to IN16).
(8) OUT LED (green) Lights when the output signal is ON (OUT1 to OUT16).
(9) USB connector Connect the USB cable here (Micro-B USB 2.0).
(10)
T1 Sets Timer 1.
(11)
T2 Sets Timer 2.
(12)
Ground terminal Connect this to the earth using an M3×4 screw.
(13)
GF mount hook A hook for installation on a GF (N) rail.
(2)
(9)
(3)
(4)
(7)
(5)
(6)
(8)
(1)
Version label
(10)
(11)
(12)
(12)
(13)
(13)

SiO Controller
SUS Corporation
3-3
3.1.3 SiO-N1
No.
Part Function
(1) Power connector Connect an AC adapter here to supply 24 V DC.
* Do not supply power from other connectors.
(2) Power LED (green) Lights when the power is ON.
(3) RUN switch Set this to RUN (right) to execute the program.
(4) RUN LED (green) Lights during RUN.
(5) Input connectors A connector used for input (e-CON (4-pole) ×8 inputs)
(6) Output connectors A connector used for output (e-CON (3-pole) ×8 outputs)
(7) IN LED (red) Lights when the input signal is ON (IN1 to IN8).
(8) OUT LED (green) Lights when the output signal is ON (OUT1 to OUT8).
(9) USB connector Connect the USB cable here (Micro-B USB 2.0).
(10)
T1 Sets Timer 1.
(11)
T2 Sets Timer 2.
(12)
Ground terminal Connect this to the earth using an M3×4 screw.
(13)
GF mount hook A hook for installation on a GF (N) rail.
(14)
ID switch * Not used in single configuration
(15)
485 communication connector a
* Not used in single configuration
(16)
485 communication connector b
* Not used in single configuration
(2)
(9)
(7)
(5)
(6)
(8)
(1)
Version label
(10)
(11)
(12)
(13)
(4)
(3)
(14)
(15)
(16)

SiO Controller
SUS Corporation
3-4
3.1.4 SiO3.2
No.
Part Function
(1) Power connector Connect an AC adapter here to supply DC 24 V.
* Do not supply power from other connectors.
(2) Power LED (green) Lights when the power is ON.
(3) RUN switch Set this to RUN (right) to execute the program.
(4) RUN LED (green) Lights during RUN.
(5) Input connectors A connector used for input (e-CON (4-pole) x 3 inputs)
(6) Output connectors A connector used for output (e-CON (3-pole) x 2 outputs)
(7) IN LED (red) Lights when the input signal is ON (IN1 to 3).
(8) OUT LED (green) Lights when the output signal is ON (OUT1 to 2).
(9) USB connector Connect the USB cable here (Micro-B USB2.0).
(10)
Ground terminal Connect this to the earth using a M3x4 screw.
(11)
GF mount hook A hook for installation on a GF (N) rail.
(2)
(9)
(7)
(5)
(6)
(8)
(1)
Version label
(10)
(4)
(3)
(11)

SiO Controller
SUS Corporation
3-5
3.1.5 SiOt
No.
Part Function
(1) Power connector Connect an AC adapter here to supply DC 24 V.
* Do not supply power from other connectors.
(2) Power LED (white) Lights when the power is ON
(3) RUN switch Set this to RUN (right) to execute the program.
(4) RUN LED (blue) Lights during RUN
(5) Input connectors A connector used for input (e-CON (4-pole) x 4 inputs)
(6) Output connectors A connector used for output (e-CON (3-pole) x 2 outputs)
(7) IN LED (red) Lights when the input signal is ON (IN 1 to 4)
(8) OUT LED (green) Lights when the output signal is ON (OUT 1 to 2)
(9) USB connector Connect the USB cable here (Micro-B USB2.0)
(10)
Ethernet connector Connect the Ethernet device
(11)
Ethernet. Connection
LED(green) Light when a device is Ethernet connected
(12)
Ethernet. Communication
LED(yellow) Lights during Ethernet communication.
(13)
ALM LED Does not use.
(14)
Ground terminal Connect this to the earth using a M3x4 screw.
(15)
GF mount hook A hook for installation on a GF (N) rail.
(2)
(3)
(4)
(5)
(6)
Version
label
(1)
(11)
(12)
(7)
(8)
(9)
(10)
(13)
(14)
(15)

SiO Controller
SUS Corporation
3-6
3.1.6 SiO – N3 / SiO – N3PNP
No.
Part Function
(1) Power connector Connect an AC adapter here to supply 24 V DC.
* Do not supply power from other connectors.
(2) Power LED (white) Lights when the power is ON.
(3) RUN switch Set this to RUN (right) to execute the program.
(4) RUN LED (blue) Lights during RUN.
(5) Input connectors A connector used for input (e-CON (4-pole) ×16 inputs)
(6) Output connectors A connector used for output (e-CON (3-pole) ×16 outputs)
(7) IN LED (red) Lights when the input signal is ON (IN 1 to 16)
(8) OUT LED (green) Lights when the output signal is ON (OUT 1 to 16)
(9) USB connector Connect the USB cable here (Micro-B USB 2.0).
(10)
T1 Sets timer 1.
(11)
T2 Sets timer 2.
(12)
Ground terminal Connect this to the earth using an M3×4 screw.
(13)
GF mount hook A hook for installation on a GF (N) rail.
(14)
ID switch ※Not used in standalone configuration
(15)
485 communication
connector a ※Not used in standalone configuration
(16)
485 communication
connector b ※Not used in standalone configuration
(2)
(10)
(12)
(9)
(3)
(4)
(13)
(11)
(7)
(5)
(6)
(8)
(1)
Version
label
(14)
* The same applies to
SIO – N3PNP.
(12)
(16)
(15)

SiO Controller
SUS Corporation
3-7
3.2 Principle of Operation
3.2.1 Program
The SiO controller program sets the conditions for turning ON each output and how long it is kept
turned ON.
Programs are edited and registered by using the dedicated software, SiO-Programmer.
The following four items are set.
1. ON conditions: Conditions for turning ON each output
2. Status: Conditions or waiting time for turning ON each output
3. OFF conditions: Conditions for turning OFF each output
4. Output method: Method of output
Example: When turning ON OUT1 for 5 seconds after IN1 turns ON
IN1
OUT1
5 seconds
For details, see “4 SiO-Programmer” or the “SiO-Programmer Instruction Manual.”

SiO Controller
SUS Corporation
3-8
3.2.2 Cycle Time
The SiO controller repeats the above processes.
The time required to execute these three processes once is called cycle time.
The cycle time of the SiO controller is 5 msec.
It is constant regardless of the number of registered programs.
3.2.3 Input Response Time
The input ON/OFF time must be set to 10 msec or more.
Failure to do so may fail to read programs.
Therefore, the input response time is 10 msec + cycle time.
Input processing
(Acquire data)
Output processing
(Set data)
Program
processing

SiO Controller
SUS Corporation
3-9
3.3 Installation
3.3.1 Installation of Controller
Install the controller observing the following precautions.
◆Avoid installation in direct sunlight.
◆Prevent foreign matter from entering the controller.
◆Avoid using in a place with high temperature, high humidity, dust, iron powder, cutting oil, or
the like.
3.3.2 Wiring to Controller
Wire the AC adapter and I/O cables as follows.
Be sure to turn OFF the power before wiring.
1. Wiring to controller and power connector
Connect 24 V DC to the power connector. It is recommended to use the dedicated AC adapter.
Otherwise, prepare a plug of the following size:
Do not supply power except from the power connector.
Because it does not pass through the protection circuit,Controller may fail.
5.5 mm (OD) ×2.1 mm (ID), Wiring symbol:
Plug Jack
2. Connection of I/O cables
Connect I/O cables to the input/output connectors.
* Be sure to insert each connector until it clicks.
Before connection After connection
Be sure to push down the lever before disconnecting the connector.
Forcibly pulling out the connector may result in a break in the wire.
!
CAUTION
!
CAUTION

SiO Controller
SUS Corporation
3-10
3.4 Settings
SiO2/SiO2PNP SiO3 SiO-N1
SiO3.2 SiOt SiO-N3/SiO-N3PNP
* 1: RUN switch, * 2: Timer 1 / Timer 2, Not provided to SiO3.2,SiOt
3.4.1 RUN Switch
Operate the RUN switch to run and stop the program.
Slide the switch to “RUN” (right) to run, and to “STOP” (left) to stop the program.
When the program stops, outputs are all turned OFF.
Be sure to set the RUN switch to “STOP” before registering a program from the SiO-Programmer.
3.4.2 Timer Setting
The SiO controller has two timer setting trimmers.
They are used when T1 or T2 is selected by the program.
*: SiO3.2 / SiOt has no timers.
The maximum value applies when T1 or T2 is selected by the program.
SiO2/SiO2PNP/SiO3/SiO-N1/SiO-N3/SiO-N3PNP
Short Long
The setting range is 0 to 5 (initial) seconds.
The maximum value can be changed by using the SiO-Programmer.
• Operate the trimmer using a small flat-head screwdriver.
*1
*2
*1
*2
*1
!
CAUTION
*1
*2
*1
*2
*1

SiO Controller
SUS Corporation
3-11
3.5 Input/Output
3.5.1 Input/Output Connectors (SiO2/SiO2PNP)
* When connecting input/output connectors, use e-CON-compatible connectors.
SUS also provides various cables with e-CON.
Visit the SUS website mentioned in “5. Options.”
Input (e-CON 4-pole) pin arrangement Output (e-CON 3-pole) pin arrangement
Pin No. Signal
1 24V *
2 -
3 0V *
4 Input signal
* 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the
controller.
Connector Input/Output
Signal Connector type
Input connectors
I1 to I6 Input IN1 to IN6 e-CON (4-pole) *
Output connectors
O1 to O4 Output OUT1 to OUT4
e-CON (3-pole) *
Pin No. Signal
1 24V *
2 0V *
3 Output signal
Input connectors I1 to I6
* 37216-62M3-004PL<3M>, 37208-62A3-004PL<3M>
Output connectors O1 to O4
* 37212-62M3-003PL<3M>

SiO Controller
SUS Corporation
3-12
3.5.2 Input/Output Connectors (SiO3)
* When connecting input/output connectors, use e-CON-compatible connectors.
SUS also provides various cables with e-CON.
Visit the SUS website mentioned in “5. Options.”
Input (e-CON 4-pole) pin arrangement Output (e-CON 3-pole) pin arrangement
Pin No. Signal
1 24V *
2 -
3 0V *
4 Input signal
* 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the
controller.
Connector Input/Output
Signal Connector type
Input connectors
IN1 to IN16 Input IN1 to IN16 e-CON (4-pole) *
Output connectors
OUT1 to OUT16 Output OUT1 to OUT16
e-CON (3-pole) *
Pin No. Signal
1 24V *
2 0V *
3 Output signal
Input connectors IN1 to IN16
* 37216-62M3-004PL<3M>
Output connectors OUT1 to
OUT 16
* 37212-62M3-003PL<3M>

SiO Controller
SUS Corporation
3-13
3.5.3 Input/Output Connectors (SiO-N1)
* When connecting input/output connectors, use e-CON-compatible connectors.
SUS also provides various cables with e-CON.
Visit the SUS website mentioned in “5. Options.”
Input (e-CON 4-pole) pin arrangement Output (e-CON 3-pole) pin arrangement
Pin No. Signal
1 24V *
2 -
3 0V *
4 Input signal
* 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the
controller.
Connector Input/Output
Signal Connector type
Input connectors
IN1 to IN8 Input IN1 to IN8 e-CON (4-pole) *
Output connectors
OUT1 to OUT8 Output OUT1 to OUT8
e-CON (3-pole) *
Pin No. Signal
1 24V *
2 0V *
3 Output signal
Input connectors IN1 to IN8
* 37216-62M3-004PL<3M>
Output connectors OUT1 to
OUT8
* 37212-62M3-003PL<3M>

SiO Controller
SUS Corporation
3-14
3.5.4 Input/Output Connectors (SiO3.2)
* When connecting input/output connectors, use e-CON-compatible connectors.
SUS also provides various cables with e-CON.
Visit the SUS website mentioned in “5. Options.”
Input (e-CON 4-pole) pin arrangement Output (e-CON 3-pole) pin arrangement
Pin No. Signal
1 24V *
2 -
3 0V *
4 Input signal
* 24V and 0V are respectively connected to 24 V and 0 V of the power supply input inside the
controller.
Connector Input/Output
Signal Connector type
Input connectors
IN1 to IN3 Input IN1 to IN3 e-CON (4-pole) *
Output connectors
OUT1 and OUT2 Output OUT1 to OUT2
e-CON (3-pole) *
Pin No. Signal
1 24V *
2 0V *
3 Output signal
Input connectors IN1 to IN3
* 37204-62M3-004PL<3M>
Output connectors OUT1 and OUT2
* 37203-62M3-003PL<3M>
This manual suits for next models
11
Table of contents
Popular Controllers manuals by other brands

Autonics
Autonics SPC Series quick start guide

gefran
gefran GFW ADV Configuration manual

Goulds Pumps
Goulds Pumps HYDROVAR Quick start guides

Intelligent lighting
Intelligent lighting DMX-240A, DMX-240B user manual

RADEMACHER
RADEMACHER RolloTron Swivel Winder Comfort 1500 Operating and assembly manual

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-R Series Programming manual

Weishaupt
Weishaupt WRSol 1.0 manual

Fire-Lite Alarms
Fire-Lite Alarms MRP-2001E Installation, operation, and programming manual

Mitsubishi Electric
Mitsubishi Electric FX3S-10M series Hardware manual

LINK-MI
LINK-MI LM-TV09 user manual

Renesas
Renesas HIP2103-4DEMO1Z user manual

Vortice
Vortice CNU Instruction booklet