FX3S SERIES PROGRAMMABLE
CONTROLLERS
HARDWARE MANUAL
This manual describes the part names, dimensions, mounting, cabling and
specifications for the product. This manual is extracted from FX3S Series User's
Manual - Hardware Edition. Refer to FX3S Series User's Manual - Hardware
Edition for more details. Before use, read this manual and manuals of relevant
products fully to acquire proficiency in the handling and operating the product.
Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration: Phillips is a registered trademark of Phillips Screw Company.
The company name and the product name to be described in this manual are
the registered trademarks or trademarks of each company.
Effective December 2017
Specifications are subject to change without notice.
©2013 MITSUBISHI ELECTRIC CORPORATION
Safety Precaution (Read these precautions before use.)
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
This manual classifies the safety precautions into two categories:
and .
Depending on the circumstances, procedures indicated by may
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated manuals
Associated manuals
FX3S Series PLC (main unit) comes with this document (hardware manual).
For a detailed explanation of the FX3S Series hardware and information on
instructions for PLC programming, refer to the relevant documents.
Manual Number JY997D48301
Revision G
Date December 2017
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
STARTUP AND
MAINTENANCE
PRECAUTIONS
•Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
•Before cleaning or retightening terminals, cut off all phases of the power
supply externally.
Failure to do so may cause electric shock.
•Before modifying or disrupting the program in operation or running the
PLC, carefully read through this manual and the associated manuals and
ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND
MAINTENANCE
PRECAUTIONS
•Turn off the power to the PLC before attaching or detaching the memory
cassette. If the memory cassette is attached or detached while the PLC's
power is on, the data in the memory may be destroyed, or the memory
cassette may be damaged.
•Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.
•Turn off the power to the PLC before connecting or disconnecting any
connection cable.
Failure to do so may cause equipment failures or malfunctions.
•Turn off the power to the PLC before attaching or detaching the following
devices.
Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, display module, expansion boards, special adapters
and memory cassette
•Do not use the chemicals for cleaning.
•If there is the possibility of touching the PLC inside a control panel in
maintenance, make sure to discharge to avoid the influence of static
electricity.
DISPOSAL PRECAUTIONS
•Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORTATION AND
STORAGE PRECAUTIONS
•The PLC is a precision instrument. During transportation, avoid impacts
larger than those specified in section 2.1 by using dedicated packaging
boxes and shock-absorbing palettes. Failure to do so may cause failures
in the PLC. After transportation, verify operation of the PLC and check for
damage of the mounting part, etc.
How to obtain manuals
For the necessary product manuals or documents, consult with your local
Mitsubishi Electric representative.
Manual name Manual No. Description
FX3S Series
User's Manual
- Hardware Edition
JY997D48601
MODEL CODE:
09R535
Explains FX
3S
Series PLC
specification details for I/O, wiring,
installation, and maintenance.
FX3S/FX3G/FX3GC/
FX3U/FX3UC Series
Programming Manual
- Basic & Applied
Instruction Edition
JY997D16601
MODEL CODE:
09R517
Describes PLC programming for
basic/applied instructions STL/
SFC programming and devices.
MELSEC-Q/L/F
Structured
Programming Manual
(Fundamentals)
SH-080782
MODEL CODE:
13JW06
Programming methods,
specifications, functions, etc.
required to create structured
programs.
FXCPU Structured
Programming Manual
[Device & Common]
JY997D26001
MODEL CODE:
09R925
Devices, parameters, etc.
provided in structured projects of
GX Works2.
FXCPU Structured
Programming Manual
[Basic & Applied
Instruction]
JY997D34701
MODEL CODE:
09R926
Sequence instructions provided
in structured projects of GX
Works2.
FXCPU Structured
Programming Manual
[Application Functions]
JY997D34801
MODEL CODE:
09R927
Application functions provided in
structured projects of GX Works2.
FX Series
User’s Manual
- Data Communication
Edition
JY997D16901
MODEL CODE:
09R715
Explains N:N link, parallel link,
computer link, no protocol
communication by RS
instructions/FX2N-232IF.
Certification of UL, cUL standards
Please consult with Mitsubishi Electric for information on UL, cUL standard
practices and the corresponding types of equipment.
Compliance with EC directive (CE Marking)
This product complies with EC directive, however, this document does not
guarantee that a mechanical system including this product will comply with EC
directive.
Compliance to EMC directive and LVD directive of the entire mechanical
system should be checked by the user/manufacturer. For more details please
contact the local Mitsubishi Electric sales site.
Caution for compliance with EC Directive
•Please use the FX3S Series programmable controllers while installed in
conductive shielded control panels under a general industrial environment.
•Programmable controllers are open-type devices that must be installed and
used within conductive control panels. Please secure the control panel lid to
the control panel (for conduction). Installation within a control panel greatly
affects the safety of the system and aids in shielding noise from the
programmable controller.
•For the control panel, use the product having sufficient strength, fire
protectiveness and shielding property to an installation environment.
•24 V DC of the power supply must be supplied from the circuit double/
reinforced insulated from the main power supply (MAINS).
Caution for compliance with the LVD directive (EN61010-2-201:2013)*1
•To an external connection port other than AC power supply terminal and AC
input/output terminal, connect the circuit separated from a dangerous
voltage by a double/reinforced insulation.
•Between the commons having the adjacent relay output terminals, if an
external power supply is higher than 120 V AC, the insulation is basic.
Therefore, when using 120 V AC or higher external power supply and 30 V
DC/AC or lower external power supply between the adjacent commons, do
not handle 30 V DC/AC or lower external power supply as a touchable part,
(When handling 30 V DC/AC or lower external power supply as a touchable
part, add a basic insulation.)
•Do not wire two or more crimp terminals to one terminal. (If the wiring with
two or more wires is needed, take an appropriate action such as adding an
external terminal.)
•For crimp terminals to be used for the wiring applied with 30 V AC or higher,
use the products with insulating sleeves.
•Cutoff device such as a breaker or a circuit protector should be installed in
accordance with the following precautions.
- Use EN60947-1 or EN60947-3 standards.
- Use CP30-BA 2P 1-MD 0.5A or the cutoff device having the cutoff
performance equivalent to CP30-BA 2P 1-MD 0.5A.
- Place the cutoff device so that it can be operated easily.
- Specify that the cutoff device is for this equipment.
*1 For the time of compliance with the LVD directive (EN61010-2-201:2013),
refer to FX3S Series User's Manual - Hardware Edition.
Incorporated Items
Check if the following product and items are included in the package:
1. Outline
1.1 Part names
When the top covers are open
FX3S/FX3G/FX3GC/
FX3U/FX3UC Series
User's Manual
- Analog Control Edition
JY997D16701
MODEL CODE:
09R619
Describes specifications for
analog control and programming
methods for FX3S/FX3G/FX3GC/
FX3U/FX3UC Series PLC.
FX3S/FX3G/FX3GC/
FX3U/FX3UC Series
User's Manual
- Positioning Control
Edition
JY997D16801
MODEL CODE:
09R620
Explains the specifications for
positioning control of FX3S/FX3G/
FX3GC/FX3U/FX3UC Series and
programming procedures.
Included Items
FX3S-10M
FX3S-14M
FX3S-20M
FX3S-30M
Product 1 unit
Dust proof protection sheet 1 sheet
Manuals [Japanese/English] 1 manual
Manual name Manual No. Description
No. Name
[1] Top cover
[2] Terminal names
shows a function grounding terminal.
[3] Terminal block covers
[4] Input display LEDs (red)
[5] Peripheral device connecting connector cover
[6]
Operation status display LEDs
POW Green On while power is on the PLC.
RUN Green On while the PLC is running.
ERR
Red Flashing when a program error occurs.
Red Lights when a CPU error occurs.
[7] Output display LEDs (red)
[8] The year and month of production
[9] Model name (abbreviation)
[10] DIN rail mounting hooks
No. Name
[1] Optional equipment connector
[2] Power supply terminal, Input (X) terminals
[3] Variable analog potentiometers
Upper side: VR1, Lower side: VR2
[4] RUN/STOP switch
[5] Peripheral device connecting connector (USB)
[6] Peripheral device connecting connector (RS-422)
[7] Service power supply terminal (AC power type only),
Output (Y) terminals
[8] Terminal cover
[9] Optional equipment connecting screw holes
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8][9][10]
[1]
[8]
[9]
[3]
[4]
[2]
[5]
[6]
[8]
[7]
Side
B
Side
A
Side
BJAPANESE ENGLISH
JY997D48301G