Swefog Live T26 User manual

LIVE T26
IVE T26
X-POWER HD SMOKE PROCESSOR
X-POWER HD SMOKE PROCESSOR
OWNER´S MANUAL
Item no. 40 201-240 Live T26 240V 50Hz
SWEFOG
OM
PEN INDS

2
IMPORTANT!
Read all cautions and warnings prior to assembly, mounting and
operating this equipment.
IMPORTANT !
Prière de lire toutes les précautions et les avertissements avant
l’assemblage, le montage et de faire fonctionner cet équipement.
WICHTIG !
Lesen Sie alle Warnungen sorgfältig bevor Sie das Gerät zusammenbauen,
installieren und benutzen.
¡IMPORTANTE!
Por favor, lea todas las precaucionas y las advertencias antes de
ensamblar, montar y operar este equipo.
IMPORTANTI!
Leggere tutti gli avvertenti prima di montare e usare questo apparecchio.
Manufactured by:
SWEFOG TECHNOLOGY GROUP AB
P.O. Box 106
SE-682 23 FILIPSTAD, Sweden
Tel: +46 590 122 50 Fax: +46 590 122 09
internet: www.swefog.com
!
CAUTION!

3
TABLE OF CONTENTS:
HOW TO USE THIS GUIDE 4
QUICK SETUP GUIDE 4
1. INTRODUCTION 5
1.1 A few words about smoke fluid 5
1.2 The Swefog Live T26 6
1.3 How does a smoke machine work? 6
1.4 EPR-Electronic Pump Ramping 6
1.5 Intelligent Soft Start 7
2. UNPACKING 7
3. SAFETY PRECAUTIONS 7
4. CE-CONFORMITY 9
5. Installation planning & precautions 9
6. Fog capacity 10
7. WIRING & CONNECTIONS 11
7.1 Mains cable 11
7.2 DMX connection 11
7.3 DIN Remote 0-10V analogue connection 12
7.4 FAN connection 12
8. OPERATION 13
8.1 Control panel & display: 13
8.2 Operation mode 14
8.2.1 DMX mode 14
8.2.2 MANUAL mode 15
8.2.3 TIMER mode 16
8.2.4 REMOTE / 0-10V mode 17
8.2.5 Switch OFF 17
8.3 External fan output control 17
8.4 MMS – Mode Memo System 18
8.5 LFS – Low Fluid Sensing 18
8.6 Mechanical overheat protection 18
8.7 Ducting system 18
8.8 Flying installation 19
8.9 Error messages 19
9. SERVICE, MAINTENANCE & REPAIR 20
9.1 Software 20
10. TROUBLESHOOTING 21
11. SWEFOG WORLD-WIDE WARRANTY 23

4
How to use this guide:
For your safety, it is important that you read this manual thoroughly before you
operate the Live T26.
This manual describes how to unpack, plan for, set up and operate the machine. It also
lists important safety precautions and a separate service & maintenance manual for
technical support.
In this manual you will find the following symbols:
CAUTION: This symbol appears adjacent to caution messages.
Not heeding these messages could result in minor personal injury
and / or damage to equipment.
WARNING: This symbol appears adjacent to warning messages.
Not heeding these messages could result in serious personal injury !
The owner´s manual contains important safety precautions and information on how to
use your machine. Always read the owner’s manual before using the machine!
This manual and updates can also be downloaded as PDF-files from the internet:
www.swefog.com
QUICK SETUP GUIDE:
1. Read chapter 3: “safety precautions”.
2. Place machine on a level surface.
3. Prepare a SWEFOG smoke fluid canister, screw the
metal capsule on and tighten. Place the canister in the
machine and connect the fluid suction tube.
4. (For DMX control only): Connect DMX cables
5. Connect to a mains outlet with earth lead (11 Amps,
2600W)
6. Select operation mode by press MODE button.
7. Machine is ready after heat up, approx. 10 minutes.
!
CAUTION!
WARNING

5
1. INTRODUCTION:
The Live T26 is a high power smoke generator. Due to the very precise output control and
the integrated fan outlet control, the machine can be used for many purposes.
•Very high output – 1,800 m3/ minute at full power.
•Continous operation at 50% output or below.
•Precise output control 1 – 100%, adjustable in 99 steps.
•Cast aluminium heat exhanger with dual stainless steel vaporizer coils.
•Built with the use of industrial quality components.
•Full R.I.S.C. microprocessor control. Software upgrade-able.
We hope that you will be fully satisfied with the performance of Swefog Live T26. To keep
your machine functioning like new for its entire life, it is important to follow the instructions
in this manual and to have regular maintenance of the machine.
For the best results, use only original waterbased Swefog original smoke or haze fluid in the
machine. Use of any other fluid will void the warranty.
1.1 A few words about smoke fluid – What is a “quality” fluid?
Most waterbased smoke or haze fluids contains glycols. The glycols in the mixture creates
the white particles that we recognizes as smoke or haze. Mainly, there are two very important
things to remember about fluids and smoke machines:
1: The water must be de-ionized. If the water contains minerals like calcium, salt etc; the heat
exchanger´s pipes will first be coated (causes poor output), and finally it will clogg the pipes
completely, and your machine is damaged. The pipes cannot be cleaned.
2: The glycol used in the mixture has to be very clean. If not, it may clogg the heat
exchanger, and most important of all, if the glycol is not 100% pure, it may be hazardous for
health, as it will contain a few promilles of unknown substances which may be dangerous for
health when heated.
And there is one very important thing to remember about fluids and health safety:
There are many low-cost fluids available, manufactured from water and chemicals with
unknown purity. The Live T26 will probably work with most of them, but always remember:
You will always get what you paid for, use original fluid. Why? The T26 is a high
performance machine, and it is developed with Swefog fluids. If other fluids are used,
remember, these fluids are not tested & approved by the manufacturer. Other fluids can be
mixed for a different vaporize (heater) temperature or contain other chemicals and / or a
different balance between water and glycols in the mixture. There might be problems with
bad (“wet”) or even toxic smoke, which can cause serious personal injury. A clogged heater
block is able to replace. Personal injurys are worse. Always remember, you are responsible
for the safety of the smoke appliance. The manufacturer cannot be held responsible if the
wrong type of fluid is used.
Non-toxic smoke and the longest lifetime of your machine is achieved with the original fluids
your machine once was developed for. And by using Swefog original fluids, you´ll be 100%
sure the smoke produced by your machine is clean.
Swefog smoke & haze fluids are based on pure, de-ionized Swedish water which is de-
mineralized in an industrial laboratory, and guaranteed free from minerals. It contains glycol
of pharama (medical) quality only – the finest and most pure glycols available. The fluid is
mixed and bottled in our factory, which guarantees full production quality control, and a
clean fluid of the highest quality.
We strongly recommend that you use Swefog original smoke fluid in your machine. Swefog
fluids are not more expensive than any other high quality smoke fluid.

6
1.2 The Swefog Live T26:
The T26 was developed with one goal in mind: To build the most versatile smoke machine
on the market. Most smoke machines today are based on old technology, with great
difficultys to regulate the smoke output. The T26 uses a very powerful heat exchanger, with
an extremely high capacity. The dual piston-pumps are microprocessor-controlled, and the
very precise output control allow the user to create everything from very small amounts of
fog to extreme volumes of pure, white smoke.
The Live T26 is advanced, but very easy to use, with the use of an alphanumerical display
and a simple-to-use menu system.
We recommend that you should have great experience with smoke appliances to use the T26,
but you don´t have to be an engeneer to handle it. Just read this manual to understand your
machine and get started!
1.3 How does a smoke machine work ?
Very simplified, a smoke machine contains a heater block (A), a pump (B) and an electronic
control module (C). The heater block contain a pipe system, an electric heater and metal,
which works like a “battery” for heat storage. The electronic module controls the temperature
in the heater block and the pump speed. When smoke is produced, the pump starts to pump
smoke fluid into the heater. Due to the very high temperature in the heater block, the fluid
will vaporize to a white smoke. When the fluid is vaporized, it consumes tremendous
amounts of energy, which will cause the temperature in the heater block to sink. The
electronics will reduce the pump speed, and finally disable the pump, when the temperature is
below the minimum operational level, in order to avoid “wet” (unvaporized) smoke. The
machine will stop for re-heating.
1.4 EPR – Electronic Pump Ramping:
The selected output will be proportional reduced with sinking temperature in the heater
block, in order to avoid unvaporized (“wet”) smoke fluid coming out. It will also increase the
total smoke output capacity, as the machine will use all heat available in the heater block.
The reduced pump speed allow the metal to equalize the temperature in the heat exchanger.
Example: If smoke is on at 100% output, the pumps will run att full speed during the initial
burst, then the pump speed will be slowly reduced until the heater temperature is below the
minimum operational level, and the pumps will be disabled. Smoke will not be available until
the machine is re-heated.

7
1.5 Intelligent Soft Start:
To maximize performance and safety, your T26 is equipped with an advanced soft start
system (do not mix up with the EPR system). Soft start is used to reduce the “crack” noise,
created during the initial burst of smoke. The “crack” noise is caused by the pump pressure
overcoming the incredible back pressure of the heat exchanger. The soft start electronics
gradually powers the pump, eliminating this crack and ensuring a quieter and smoother
operational level following initial start up. It will also increase the lifetime of the internal
components, as high pressure peak loads on pumps, piping and couplings are reduced.
The T26 will always start the pumps at 20%. The electronics will slowly increase (or
decrease) the pump speed to the selected output level. At full output (100%) selected, the soft
start will start the pumps at 20%, and increase the speed during 6.4 seconds to 100%. The
maximum soft start time is therefore 6.4 seconds. At selected outputs below 100%, the soft
start time interval will be shorter.
Please note: The maximum pump speed is always controlled by the EPR system. If the
temperature is too low for the selected output, the EPR will automatically reduce the pump
speed. This is a fully automatic system, controlled by the processor, and cannot (and should
not) be disabled or modified by the user.
2. Unpacking:
The Live T26 package contains:
•One machine.
•One canister metal fitting with fluid suction pipe and floatchamber.
•One manual.
•Please note, no fluid is included.
•Save the carton and packing material for future use.
•If the machine needs to be transported, ship in the original box, and place it on a small pallet.
Use stripes to fix it to the pallet. It is a cheap and simple way to avoid damage during
transport.
3. Safety precautions:
•Smoke residues and fluid spillage may be dangerous. A slippery surface can cause
serious personal injury! ALWAYS check surfaces before, during and after the use of
the machine.
•Do NOT install this machine directly over an audience.
•Do NOT point the discharge directly into an audience.
•Make sure the area in which this product is to be used is well ventilated.
•Do NOT operate near flammable materials or fire.
•Do NOT place hands or face near heat exchanger or output during operation. NOTE:
There might be puffs of smoke from the output when machine is not operating.
•Do NOT expose to rain or moisture.
•Connect to mains outlet with earth. Use a cable with earth. Check for correct voltage
WARNING

8
and/or mains frequency (see machine label). NEVER use the machine with wrong mains
voltage or frequency.
•NOTE: The condensation of the smoke makes floors, stairs and other surfaces slippery.
Do NOT point the discharge towards cool or hard surfaces like wood, plastics, glass or
metal. If the machine is frequently used, or used for a long time, often check that no
surface becomes slippery.
•Use Swefog waterbased fluids only. Other fluids may damage the machine, cause
residues inside and outside the machine, or cause toxic or odorous smoke. USE OF ANY
OTHER FLUID WILL VOID THE WARRANTY.
•The fluid contain glycol. Glycol may cause some types of paint to get wet. It may also
affect other materials or surfaces. It may cause unprotected metal surfaces to corrode
(rust). Do not point the discharge directly to a painted or sensitive surface.
•NEVER mix or dilute the fluid.
•NEVER heat the fluid. Use room-temperature fluid only.
•Use your head! Use responsible concentrations of fog to create atmospheric effects.
•NOT for residential use.
•Operate in room temperature only.
•NEVER cover vents or air inlets on the machine housing.
•Service internal parts ONLY if you have the know-how and experience to perform the
service correctly. If not, please contact a Swefog service centre or the manufacturer.
NOTE: Incorrect service works and/or the use of non-original spare parts will void the
warranty.
•NEVER change parts or details inside, use original spare parts only!
•NOTE: If there is – for any reason – a fluid leakage or spillage, wipe off fluid spillage.
DO NOT use the machine until it is mended.
•NOTE: The smoke may cause residues on mirrors, lenses and similar components. Keep
away from equipment with fan ventilation.
•Must be handled by personnell with great experience with smoke appliances.
•Operating the machine with an empty fluid tank will damage the pumps. Normally, the
automatic pump shutdown system will disable the pumps when the fluid is almost empty
(approx. 0,5 L left). The system only works with the floatchamber in the tank, and
capsule facing backwards.
!
CAUTION!

9
4. CE-conformity (230V models only):
We, Swefog, declare that the appliance described in this manual
conforms to the EEC machine directive. Complete documents may
be required from Swefog.
5. Installation planning & precautions:
Carry handle
Fluid tube connector
Canister metal fitting
Output nozzle
1. Place the machine on a level surface.
2. Use Swefog fluid, 5L canister size. Remove the plastic capsule, replace it with the canister
metal fitting with fluid suction pipe (included with the machine). Ensure an airtight
connection.
RISK OF FIRE OR EXPLOSION! NEVER use any kind of flammable liquid in the
machine.
OUTPUT NOZZLE BECOMES EXTREMELY HOT! Keep hands off!
3. Place the canister in the canister space, with the capsule facing backwards. NOTE: If the
canister is placed in the opposite direction, with the capsule facing the front, the automatic
pump disable system will not work when the fluid is empty.
4. Connect the fluid tube to the canister.
5. NEVER fill fluid or replace canister while machine is operating. To refill fluid to a canister,
always remove the canister from the machine! Do NOT fill fluid with the canister placed in
the machine.
WARNING

10
XLR & DIN connectors
XLR & DIN connectors
Support handle
Mains cable
Fan fuse Fan connector
6. If the machine is to be used with DMX: Connect a 5-pin DMX cable to the male (=input)
XLR connector. See below for further instructions.
6. Fog capacity:
•In all modes, the T26 can produce fog until the temperature is below the minimum
operational level. Below this point, the pumps are unable to run.
•The machine can produce smoke continous (without interrups for re-heating) at output levels
below 50%. If the machine is to be used for continous operation, make sure the maximum
heater temperature is reached before the operation starts.
•At output levels between 50% and 80%, the machine can produce smoke for several minutes
without interrups for re-heating.
•At output levels more than 80%, the machine can produce fog for 60 – 120 seconds until the
temperature is below the minimum operational level.

11
7. Wiring & connectors:
7.1 Mains cable:
Mains cable wiring instruction:
Brown: Live
Blue: Neutral
Yellow / Green: Earth
The Live T26 is fitted with a mains cable with European standard plug with earth. If the plug
is replaced, connect the wires as shown above. Use a mains plug approved for min. 16 Amps.
RISK OF ELECTRIC SHOCK!
Refer to qualified personnell if the mains cable must be modified or replaced. NEVER
use a damaged cable.
7.2 DMX Connection:
1
2
3
4
5
15
3
24
15
3
24
Male connector Female connector Female XLR plug
Use a 5-pin female XLR for DMX input.
Pin 1 = signal + (positive)
Pin 2 = signal – (negative)
Pin 3 = 0V (earth)
Onboard XLR connectors:
MALE: Data IN for receiving data.
FEMALE: Data OUT for transmitting data.
WARNING

12
7.3 DIN Remote / 0-10V analogue connector:
DIN 41 524 pinout:
1
2
3
45
13
2
45
Female connector on machine Male plug from Swefog analogue remote controller or a 0-10V
lightdesk.
Use a 5-pin male DIN plug for connection of an analogue remote control.
Pin 1 = Smoke density (not used on T26).
Pin 2 = Ground
Pin 3 = Fan speed
Pin 4 = Smoke output
Pin 5 = +12V out (used with Swefog remote control only, NOT for use with a light desk or
for any other purpose).
Do NOT link or short circuit any pins! It may damage the machine´s electronics.
If an external voltage source (e.g. a lightdesk) is used, NEVER exceed +12V output voltage!
See chapter 6:4 (Operation: Remote / 0-10V mode) for further information.
7.4 FAN Connector:
Live + Neutral
Earth
Use a cable with IEC male connector for power supply to an external fan.
The connected fan must be earthed.
NEVER use a 2-pin IEC connector without earth.
WARNING

13
8. OPERATION :
8.1 Control panel & display:
All settings & programming is made with the use of the control panel & the
alphanumerical display.
SWITCH ON: Plug the T26 into a power socket with the appropriate voltage. NOTE: The
machine consumes 2,600 Watts = 11 Amps at 230V and NO fan connected.
•Auto-ON: If the machine has been disconnected from mains, it will automatically switch ON
when the plug is connected to a mains socket. The GREEN “standby” indicator illuminates.
•From Standby mode (RED “standby” indicator illuminates): Press and hold the “OK” switch
until the “standby” indicator illuminates GREEN.
The T26 will require approximately 8 minutes to heat to a minimum operational temperature,
and approximately 10 minutes to heat to its highest temperature.
STANDBY INDICATOR:
•No indication: The machine is disconnected from mains.
•RED: Standby.
•GREEN: Power ON.
READY INDICATOR:
•Until the GREEN “ready” indicator starts to flash, the pumps are unable to run.
•A flashing indicator indicates that the machine is able to produce fog, but the machine is still
heating and is not yet at its full capacity.
•The indicator illuminates at highest temperature. This indicates maximum fog capacity.
•The indicator will start to flash during operation. This is normal, and indicates the machine is
re-heating.
TIMER INDICATOR:
•YELLOW: Timer is in operation.

14
8.2 Operation mode:
•Press MODE switch to select how to operate the machine: DMX / Manual / Timer / Remote
0-10V/ switch off.
Op mode DMX Ch: 001
Op mode MANUAL
Time:00:00 smoke
Op mode REMOTE
SWITCH OFF? (OK)
P 0% FAN 0%
>P 0% FAN 0%
>P 0% FAN 0%
P 0% FAN 0%
MODE MODE
MODE
MODE
MODE
1.
2.
3.
4.
5.
Press MODE to select how
to control the machine.
8.2.1 DMX mode:
Select DMX mode to control the machine from a DMX light desk.
1. INTRODUCTION:
The display indicates: Operation mode (DMX), programmed start channel, pump and fan
output.
Op mode DMX Ch: 001
P 0% FAN 0%
The machine uses maximum 2 channels:
Channel 1 = Output, channel 2 = fan speed.
The last stored address will be stored in the processor´s memory when the machine is
switched off and / or mains voltage is disconnected. This address is default next time the
machine is switched on. In an application where the machine is used with the same address
every time (e.g. on tour or in permanent installations), set of address is not necessary, as the
machine always start up with the same address automatically.
If, for any reason, a different address is to be used temporarily: Set the temporary address
(indicated in display window), but do not press “OK”. The machine will respond to the
temporary address until mains power is switched off. Next time it is switched on, the
common favourite address will be set as default.
2. ADDRESS PROGRAMMING:
1. Press MENU to set a start address. Use the ▲/ ▼buttons to select an address between 1
and 511. Press OK to store the address.
Set start address
Ch: 001
2. Press MENU for exit.

15
3. The fog output and fan speed is proportional to the DMX level:
Output % DMX level ▌Output % DMX level ▌Output % DMX level
▌▌
1 4 ▌35 90 ▌70 179
5 14 ▌40 102 ▌75 191
10 26 ▌45 115 ▌80 204
15 39 ▌50 129 ▌85 217
20 51 ▌55 140 ▌90 230
25 64 ▌60 153 ▌95 242
30 77 ▌65 166 ▌100 255
3. DAISY-CHAIN MULTIPLE FIXTURES:
Use a standard DMX cable, with one male and one female 5-pin connector. Use the male plug
for connection to the DMX out (female) connector on the machine. Plug the other end
(female connector) of this cable to the next unit in the series. Repeat this step with each
successive unit in the chain (connect unit 2 to 3, unit 3 to 4 etc), until all units are connected.
Daisy-chain rule: You need one DMX cable for each unit you want to connect in the daisy-
chain.
DMX light desk
DMX out
Swefog Live T26 or
other DMX fixture
IN DMX OUT
Swefog Live T26 or
other DMX fixture
IN DMX OUT
Swefog Live T26 or
other DMX fixture
IN DMX OUT
1 2 ..n
8.2.2. Manual mode (stand-alone):
Select manual mode if you wish to operate the machine from its keypad only.
Op mode MANUAL
>P 0% FAN 0%
1. Set fog output level (P) and fan speed (Fan): Use the ▲/ ▼buttons to set an output level
from 0 to 100%. Press and hold for faster count. Use the ◄/ ►buttons to change between
smoke output and fan speed. An arrow indicates whether the smoke output ( >P ) or the fan
speed ( >Fan ) is set.
2. Press OK button for start the production of fog. The RED “smoke on” indicator illuminates.
NOTE: The soft start system always starts the machine at 20% fog output. After a few
seconds the machine will produce fog at selected level.
3. Press OK button for stop fog production.
In manual mode, the fog production is automatically disabled if the machine stop for re-
heating. After an interrupt, the user need to press the “OK” button for continue the fog
production. This is a safety feature to prevent from uncontrolled fog production.

16
8.2.3. Timer mode:
Select timer mode to produce fog with fixed time intervals. The T26 uses the microprocessor
to control operate / delay time, which makes the timer very precise.
Time: 00:00 smoke
>P: 0% FAN 0%
1. INTRODUCTION:
The machine is using the microprocessor to control the timing process, which makes smoke
& delay times 100% precise.
NOTE: Do not program short operate time intervals (below 7 seconds) if you have selected a
high fog output. The pump soft start system will prevent the pumps to run at full speed the
first seconds.
2. PROGRAMMING THE TIMER:
1. Press MENU to set operate and delay time. Use the ▲/ ▼buttons to set time in seconds. Use
the ◄/ ►buttons to change between operate and delay time. Press MENU to exit.
Set operate time
00:00 (min:sec)
◄/ ►
Set delay time
00:00 (min:sec)
2. Set fog output level (P) and fan speed (Fan): Use the ▲/ ▼buttons to set an output level
from 0 to 100%. Press and hold for faster count. Use the ◄/ ►buttons to change between
smoke output and fan speed. An arrow indicates whether the smoke output ( >P ) or the fan
speed ( >Fan ) is set.
3. ACTIVATING THE TIMER:
1. Press OK button to start the timer. The YELLOW “Timer” indicator illuminates. The display
indicates remaining time (operate / delay). The RED “smoke on” indicator illuminates when
machine is operating. The indicator is off at delay status.
Time: 00:24 smoke
>P: 75% FAN 100%
NOTE: The soft start system always starts the machine at 20% fog output. After a few
seconds the machine will produce fog at selected level.
2. Press OK to stop the timer. The Yellow “Timer” indicator is off.

17
8.2.4. Remote / 0-10V mode:
Select this mode to control the machine with a Swefog analog remote controller (optional) or
a 0-10V light desk.
Op mode REMOTE
P 0% FAN 0%
Connect the remote controller or a cable from a light desk to the 5-pin DIN connector. The
fog output and the fan speed is proportional to the amount of voltage supplied.
Swefog analog remote control:
1. Select fog output with the “fog output” knob.
2. Select fan speed with the “fan speed” knob.
3. To produce fog, press the “smoke on” switch.
NOTE: When analog remote control is used, all values are approximate. The display on the
machine indicates the current smoke output.
8.2.5. Switch off:
SWITCH OFF? (OK)
Press OK for standby. The RED standby indicator illuminates. At standby mode, the main
processor, heater, pumps and all other internal electrical parts are OFF. The machine uses a
power save circuit which senses the OK button only, for switching on.
8.3 External fan control output:
Connect a 1-phase 230V fan to the IEC fan outlet. Maximum fan motor power is 500W.
NOTE: With a fan connected, the total power consumption is increased. The fan motor power
consumption is added to the consumption of the machine (2,600W). With a 500W fan
connected, the total power consumption is 3,100W (= 13,5 Amp. At 230V ). Make sure your
power outlet socket is appropriate fused.
The fan speed is controlled with the electronics. The internal fan speed regulator works like a
light dimmer, the output voltage is 0 – 230V. Most fan motors does not start at fan speed
levels below 30 – 40%. Always test with the fan connected. To avoid fan motor damage, do
not run the fan at very low speeds, where the fan wheel does not rotate properly. If the fan is
not to be used, ensure the fan speed is set to 0%, to avoid motor damage. Consult fan
manufacturer for further information.

18
8.4 Mode Memo System (MMS):
At power on, the machine will automatically start in the same operation mode as used last
time. In DMX mode, it also remember the last programmed DMX address. Read more, see
chapter 2, “DMX mode”.
The MMS feature is a handy function for permanent installations, touring or any other
application where the machine is always used with the same operation mode.
8.5 Low Fluid Sensing – LFS
Fluid level low
Pumps disabled
The T26 is equipped with a wireless low fluid level sensing system, which will prevent the
pumps from running dry. The LFS system uses a magnetic switch underneath the fluid
canister, and a magnetic floatchamber inside the canister. When the fluid level is low (approx.
0,5 L), the pumps are disabled, and a message appears in the display.
The system will not work if the fluid cap is not facing backwards, and / or the magnetic
floatchamber is inside the canister.
NOTE: Iron filings will get caught to the magnetic floatchamber and corrode, which will
result as small, brown dots. Clean the floatchamber every time the fluid is changed or
replaced. Magnetic metal particles can be removed with a short burst with compressed air, or
a magnet.
8.6 Mechanical overheat protection:
The T26 uses three mechanical overheat protection switches: One for each pump, and one 16
Amp. thermostat for the heater block. All will automatically reset after an activation.
8.7 Ducting system:
If the machine is to be used with a fog distribution system, it should be placed so that the fog
is discharged into the distribution system´s inlet or as directed by the distribution systems
instructions. Always use the Swefog ducting system adaptor (optional). Do NOT slip the
tubing over the end of the machine´s output collar.
CAUTION! Using a ducting system may result in smoke fluid residues, which may cause
slippery floors.
!
CAUTION!

19
8.8 Flying installation:
Use the Swefog flying bracket kit (optional). NEVER install the machine directly over an
audience. ALWAYS use the drip tray provided with the kit.
CAUTION! Check and clean the drip tray often, every time the fluid canister is changed.
Fluid drops will cause slippery floors!
WARNING! Read the safety instructions provided with the flying bracket kit. Assemble and
install the kit according to the instructions provided with the kit. Always use the safety wire
provided. Wrong installation of the flying bracket kit may cause serious personal injury.
8.9 Error messages:
If a problem is discovered by the processor, it will automatically shut down the machine, and
display an error code. If an error code appears in the display, contact your Swefog dealer for
solving the problem. The basic error messages are: C101, C102, C103. All these error codes
indicates problem with the temperature sensing system.
WARNING
!
CAUTION!

20
9. SERVICE, MAINTENANCE & REPAIR:
The Live T26 is made with industrial standard components. If regular care and maintenance
is performed, the machine will last for many years of use.
If you have good know-how and great experience with smoke machines, you may perform
cleaning and basic troubleshooting. If not, refer servicing to qualified technical personnel, or
contact a preferred Swefog dealer. NEVER try to adjust or modify electrical or mechanical
parts. Preferred dealers will provide qualified service technicians, and will be able to perform
most service works.
This manual contains basic trobleshooting only. For serious problems with your machine,
contact your Swefog dealer.
9.1 Software:
The Live T26 uses a powerful microprocessor for control of all functions. The
microprocessor is using a software. If you suspect a problem with the processor, or
malfunction on electronics, always check the software version. Every time the machine is
switched ON, the model name & software version is displayed for 2 seconds in the display
window:
Swefog Live T26 v1.0
└─────────────┘ └───┘
Name & model Software version
NOTE: The software version number can not be confirmed by reading the machine label or
serial number. Due to updates, the software versions may be changed several times during
your machine´s lifetime. Always look for the correct software version shown in the display
window.
This manual suits for next models
1
Table of contents
Other Swefog Fog Machine manuals
Popular Fog Machine manuals by other brands

Velleman
Velleman HQ Power VDP1500SSM manual

SnowMasters Special Effects
SnowMasters Special Effects BM-100 Bubble Master user manual

Chauvet DJ
Chauvet DJ Hurricane 2000 user manual

leco
leco P-1 Instruction manual and parts list

Rosco
Rosco Vapour Fog Machine operating instructions

Antari
Antari HZ-350 user manual