Stage4 miniMYSTYQUE 200 User manual

User manual
ENGLISH
miniMYSTYQUE 200
Version 1.0

Warning 1
3
3
3
3
4
5
6
6
7
8
10
12
Caution
Particular Warning!
Please note:
Important
Figure 1 Haze Functions
Description
Getting ready
Mounting
Set Up
Operation
Troubleshooting
Maintenance
Product Specification 13
CONTENTS
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
Read the manual
Indoor use only
This symbol indicating separate collection for electrical and
electronic equipment
Warning: situations that could cause injury to yourself or
others
Caution: situations that could cause damage to your
machine or other equipment
Note: notes, usage tips, or additional information
!
Instructional icons

1
Like all electronic products, Haze machine must be used
with safety precautions in mind.
Fill enough fog fluid before plugging in, empty fluid
tank when not in use or moving.
• Useonlyappropriate,groundedelectricpowersupplyforyour
unit. Seeyourproductspecificationlabelforappropriatepower
supply. This appliance must be earthed.
• Disconnectfromelectricmainspowersupplywhennotinuse,
whenfillingthefluidtank,orwhenchangingafuse.
Keep unit dry. If moisture or liquids enter the Haze machine case,
immediatelydisconnectpowersupply.Contactaservicetechnician
to determine safety for use.
• Beforemovingthemachine,alwaysdrainfogfluidandtightenthe
tankcapsecurelytoavoidspilling.
• Withoutuser-serviceablepartsinthepackage,pleasecontactyour
localagentorqualifiedtechnicianforservicing.
• Withoutchangeablestructurebynon-qualifieduser,pleasedonot
openthecoverorhaveanychangeatwill,otherwise,itmaycause
accident!
• Hazemachineisforadultuse.Keepoutofreachofchildren. Never
leavetheunitrunningunattended.
• Hazemachinenozzlegetshotover200degrees(centigrade)
during use.Don’ttouch!Maintainasafedistanceover100CM.
Neveraimthenozzledirectlyatpeople.
Thank you for selecting our Haze machine, you already own the
high-tech, and user-friendly Haze! Better read the manual thoroughly
before operation, follow instruction will help you have a
smooth handling with Haze machine to achieve the most
satisfactory fog effect, it will also assist unit to further prolong life
time as a whole.
Warning!
!

2
• Keepcaseclosedwhileoperating.Putthemachineindraftyplace.
Donotinsertobjectsintoairvents.Allow100CMspaceorabove
aroundthemachineforproperventilation.
• KeepHazemachineawayfromflamesandflammableitems.
Neveraimthenozzleatopenflamesorsparks.Useonlyhighquality
water-basedHazefluid.Neverputflammablesubstancesintothe
tank.
• Machinemustcooldownbeforecleaning,servicingorstoring.
• Neverputanyflammablematerial(lipid,gas,perfumeetc.)intothe
tank,readtheusermanualthoroughlybeforeoperation.
• Betteruseourhighqualitywater-basedfogfluid,randomusewith
otherHazefluidmayjamthepipe,orevenerodethecomponents
inside.
• Keepsufficientfluidintank.Operatingtheunitwithoutsufficient
fluid,thepumpwillstopworking.
• Ifanyabnormalrunningoccurs,stopitimmediately,emptythefluid,
andbringthedoneupunit(recommendoriginalbox)toyouragent
ordealerforservicing.Makesureallfluidisemptyfromthetank
beforemovingorshipping.
• Neverdrinkfogfluid.Ifingested,calladoctorimmediately.
Iffluidcontactseyesorskin,rinseskinthoroughlywithwater.
• Readusermanualinstructionsthoroughlybeforeoperating.
Followtheinstruction.Neverremovewarningorinformativelabels
from the unit.
Important Safeguards
•Readallinstruction
•Productsforindooruseonly.Keepawayfromliquids.
Neveroperateinrainorindampconditions.
•Unitmustbegrounded.
•Donnotopenunit,riskofelectricshock.
•Donotimmerseinanyliquid
•Savetheseinstructions.

3
Caution!
Therearenouserserviceablepartsinsidethisunit.
Donotattemptanyrepairsyourself,doingsowillvoid
yourmanufactureswarranty.Intheunlikelyeventyour
unitmayrequireservicepleasecontactyourlocaldealer.
Particular Warning :
Please install the product correctly according to the
instructionoftheusermanual.Toavoidanyaccident,
itisnotallowedtoinstalltheproductwithanyway
not instructed on the user manual. If accident happens
because users do not install the product according to
the instruction of the user manual, the manufacturer
willnottakeanyresponsibility.
Please note:
Specicationsandimprovementsinthedesignofthis
unitandthismanualaresubjecttochangewithoutany
priorwrittennotice.
Important
The wires in this mains lead are colored in
accordance with the following code.
230V, 240V .................................................................
GreenandYellow–Earthed(E)
Blue–Neutral(N)
Brown–Live(L)
Warning: This appliance must be earthed.
100V, 120V .................................................................
GreenandYellow–Earthed(E)
White–Neutral(N)
Black–Live(L)
Warning: This appliance must be earthed.
!

4
A. HangingBracketwithhandlescrew(usedasatripod)
B. Tank
C. FixedRing
D. AirDeector
E. Sponge
F. SmokeOutput
G. ControlSocketConnection
H. TwopinDipSwitchforFluidSensor
I. LED Indicator for No Fluid Detection
Figure1 Haze Functions
C
D
B
A
E
F
J. Manual Fog
K. PowerON/OFF
L. Fuse
M. ElectricPowerInput
N. Safety Hole
O. Pad
E
O
G
HJ
IK
M
N
L

5
Description
1. ThehighestvaluedHazecanfogcontinuouslyuntilfluidisrunout.
2. Primaryheatinguptakesonly70seconds.
3. 0-100%outputadjustment.Dry,stableandsmoothsmokeoutput.
Effectofhighqualitysmokeoutputcoordinatedwithbuilt-infan,
letthesmokebethinnerandmoreuniform.
4. Thehangingbracketcanbeadjusteddifferentangles.
It can be hung or used as tripod
5. Themachinecanbesetforfogginguporforward.
6. Equippedwith0-90degreeadjustableairdeflector.
7. Excellentdesignof1.5literliquidtankhasnoworryofoilleaking
whenbeingoperatedupsprayorforwardspray.
8. Verydurableandabletokeepworkinglongtime.
9. Self-cleaning system: 100secondsaftershotdown,themachine
stopsworking.Duringthe100seconds,themachinedoesself-
cleaning of oil residue in the pipe.
10. Functionofdetectingnofluid.Themachinestopsworking
automaticallywhenfluidisrunout,andLEDlightindicatesno
fluidstatus.ThisfunctioncanbeselectedOFF.
11. CandofoggingmanuallyorbyVT-1controller.
SimpleandhumanizeddesignletuseofminiMYSTYQUE 200
beeasier.
12. Light and thin housing can be easily hung up, located on the
ground,orinstalledinanyplaceswhereneedtheequipment.

6
Getting Ready
Allproductsarethoroughlytestedatthefactoryandshippedin
perfect condition. If damage has occurred during shipping, or if
components are missing, please contact your local dealer immediately.
Your package should include:
1.OneHazeMachine
2.One product user manual
Mounting
miniMYSTYQUE 200isshippedcomplete,readytouse.Thebracketis
installedbefore shipping, the unit can be hung in any position.
Fastentheeffectfanontormtrussing(Usea15-kgratedorstronger
C-clampboltedontothebracket,enhancingsafetynecessarilywith
safetycables).Allowenoughspace(around20cm)onallsidesfor
proper cooling.
C-clamp
safety cable
Note:
When mounting , please be sure
the safety cable must be through
thesafetyHoleonthebackofthe
machine.

7
Set Up
1. Opentheshippingcartonandcarefullyremovetheunitfromthe
shipping carton;
2. BesuretoremovepackingmaterialfromaroundtheHaze
machine, especially near the nozzle;
3. SettheHazemachineonadry,flatsurface;
4. Useonlyhighquality,water-basedfogfluid;
5. Firmlyattachtheremotecontrolmechanismtosocket(Figure1-G)
onthebackoftheunit;
6. PlugmainspowercordfromtheHazemachineintoappropriate
powersupplysocket.Waitabout70secondsforheatingelementto
heat up;
7. Refer to your controller manual for operation details;
8. Movingthemachineduringoperationcouldprobablygetair
entered into the liquid pipe and affect smoothness of fog blasts. If
this happened, press the “Manual Fog” button to fog for a
moment.Untiltheairisdispersedfromthepipe,themachinewill
recoveritsnormalfogging.
Very Important:
Pleasedonotpulloutthepowersuddenlywhenthemachineisin
normalsmokecondition.
No Fluid Detection
Themachinecanperformnouiddetection.
PleaseiponeofthetwodipswitchestoONin
thepicturelefttodetectthenouid.Whenone
ofthedipswitchesisON,theLEDindicatorwill
lightup.Whentheuidisrunout,themachine
stopsworkingautomatically,andLEDindicator
willashindicatesnouidstatus.
1. BothofthedipswitchesareOFF,themachinedoesnotdetect
whethertheuidisempty,andmachinewillnotstopworking
automatically.

8
2. Whenthemachineisstartedfor80seconds,themachinewill
detectifthereisuidcurrently.
3. Whenthemachinehasnouid,themachinetakesabout30
secondstodetect.After30secondsandthereisnouid,
themachinestopsworkingautomatically.
4. Afterllingtheuid,the“manualfog”buttonmustbeturnedOFF,
and then turned ON to reset.
Operation
Remote Control Operation...............................................................
For best result, use VT-1 wired controller.
1. Firmlyattachtheremotecontrolmechanismtosocket(Figure1-G)
onthebackoftheunit;
2. Plugmainspowercordfromthemachineintoappropriatepower
supplysocket,theredLEDuponthecontrollerislighted;
3. Thevolumeadjustmentknobonthecontrolleriswiththeswitch;
4. Turntheknobcounterclockwisetotheendtoswitchoff,thefogis
off, the green LED upon the controller is lighted;
5. Thevolumeadjustmentknobclockwiseadjustmentvolume
increases,counterclockwiseadjustmentvolumereduction,the
greenLEDuponthecontrollerisblinking;
6. When the machine stops fogging, please do not unplug the
machineimmediately,butwait100secondstoletthemachine
automaticallycleantheuidleftinthepipe.Thisistoavoidcausing
negativeeffectwhenusednexttime.

9
A-1/4”stereojack B- Knob
C- GreenLED(Volumeoutput) D- RedLED(power)
A
CB
D
VT-1 wired controller
Controllerpowercordlength:3m;
Connector:1/4“stereojack;
Function:Airvolumeadjustment&ON/OFF;
Model VT-1
Cable Length 3m
EffectiveDistance N/A
Connector 1/4”stereojack
Function ON/OFF
Volume adjustment
Dimension(LxWxH) 90x50x39mm
Weight 0.257kg

10
Manual Fogging Operation..............................................................
1. Aslongasheatingiscompleted,turnonthe“Manualfog”
button,themachinewithmaximumoutputfogging;
2. Turn off the “Manual fog” button to stop.
3. When the machine stops fogging, please do not unplug the
machineimmediately,butwait100secondstoletthemachine
automaticallycleantheuidleftinthepipe.Thisistoavoidcausing
negativeeffectwhenusednexttime.
Troubleshooting
Thistroubleshootingguideismeanttohelpsolvesimpleproblems.
Ifaproblemoccurs,carryoutthestepsbelowinsequenceuntila
solution is found. Once the unit operates properly, do not carry out
followingsteps.Iftheproblempersists,referservicingtoaqualied
technician.
Power Connected but No Smoke is Emitted:
1. Checkthepowersupply.Plugtheunitintogroundedelectric
powersupplysocketwithpropervoltage.
2. Disconnectthemachinefromelectricpowersupply.Replacefuse
withoneofthesametype.
3. Keepsufcientuidintank.
4. Checkiftheoilpipehasnormaluidpumping.
5. Checkiftheoilpipeisbroken.
6. Checkifpumpisworking(withuidowornot).
7. Checkiftheheaterisheating(touchthepaneltoseeifitiswarming).
8. Checkyourcontrollerifincorrectconnection.

11
Power Connected, Fog Blasts not Smooth:
Movingthemachineduringoperationcouldprobablygetairentered
into the liquid pipe and affect smoothness of fog blasts. If this
happened, press Manual Fog button to fog for a moment. Until the
airisdispersedfromthepipe,themachinewillrecoveritsnormal
fogging.
Shouldtherebeanylowfogemitted,runningnoisilyorhindered
fogging,pleasewaitforself-cleaningandpullouttheplug
immediately.Checkifstringenoughuid,ifthepipeconnectedto
thetankisclean,ifthere’sairinsidethepipe,iftheliquidows,if
not,plug-inagain;stillpersistsabnormalrunning,andIfcausation
isunclear,stoprunningtoavoidanydamage,shutdowntocool
it,andbringunittoyourlocalagentorappointedserviceplacefor
inspection, prohibit any dismantlement by yourself.
• Ifuidisrunout,fullthetankwithuidandpress“Manual
Fog” to off than to on again to reset.
Very Important:
Pleasedonotpulloutthepowersuddenlywhenthemachineisin
normalsmokecondition.

12
Maintenance
Beforedoingmaintenance,pleasemakesurethatthepoweriscut,the
powercordisunplugged,andthemachineitselfhascooleddown.
The maintenance must be done by qualified person.
1. Thefluidisnotallowedtogetdirty.Besuretoalwayscleanor
replacethecapsonthetank(Replacethecapsonthetankdirectly.
Thiskitincludescap,pipeandfilter)andtightthecoveroftheHaze
machinetankimmediatelyafterfilling.
2. Prolonged use, the nozzle may be clogging by impurities, periodically
usetoolstocleanthenozzles,keepthenozzleunobstructed.
3. Prolonged use, please clean the air inlet regularly.
4. Prolongeduse,spongeinsidetheventmayaccumulateoil,
periodicallycleanedoutorreplacedwithanewsponge.
5. Periodicallychecktheconnectionsamongtheoiltube,thepump
andtheheatertoseeifthere’soilleaking.Ifpositive,locktightthe
connectionscarefullywithpropertool.
6. PCboardshouldbekeptfrombeingdirtiedwithoil.Incasethis
happened,dismantlecarefullythePCB,andhaveitbrushed
cleanbothsideswithdilutealcohol.Leaveitdryitself,theninstall
itback.Makesureallwiresarewellconnected.
7. Cleanthemetalcoverwithdrycloth.

13
Product Specifications
* Voltage is preset at the factory and may not be changed.
Name Haze
Item No. miniMYSTYQUE 200
HeaterPower 200W
Consumption 220W
Fuse(100V) T3.15A/250V
Fuse(120V) T3A/250V
Fuse(230V,240V) T2A/250V
Built-inFunction Manual Fogging
FogOutput(cu.ft/min) 3000
WarmUptime(seconds) 70s
FluidConsumption(ml/min) 2.2ml/min
Remote Connection 1/4”jack
LowFluidShutdown YES
Display NO
Tank(liters) 1.5L
Bracket Yes
Voltage 100V50/60Hz;120V/60Hz;230V,240V/50Hz
Dimensions/mm
(LxWxHwithbracket) 345x192x267mm
Weight(kg) 4.8kg
Controller(Optional) VT-1
345mm 192mm
267mm

Savethisinstructionproperly
Alltheinformationissubjecttochangewithoutpriornotice
miniMYSTYQUE 200
Table of contents
Other Stage4 Fog Machine manuals
Popular Fog Machine manuals by other brands

JB Systems Light