Taiden TMX-0404SDI User manual

High Definition Digital Video Tracking Matrix Switcher
Professional Matrix Switchers
Installation and Operation Manual
V 1.1

I
Remark:
All rights reserved for translation, reprint or reproduction
Contents may change without prior announcement
All technical specifications are guideline data and not guaranteed features
Taiden Co., Ltd. is not responsible for any damage caused by improper use of this manual
The equipment must be connected to earth!
This product conforms to the rules of the European directive 2004/108/EC.
If any detailed information needed, please contact your local agent or TAIDEN service center in your region.
Any feedback, advice and suggestion about the products is appreciated
TAIDEN is the registered trademark of TAIDEN Co., Ltd.

Important Safety Instruction
1. Read and keep these instructions.
2. Heed all warnings and follow all instructions.
3. The apparatus shall not be exposed to dripping or
splashing and that no objects filled with liquids, such
as vases, shall be placed on the apparatus.
4. The MAINS plug serving as a disconnection device,
should be easy to operate.
5. The apparatus should be connected to the MAINS
socket-outlet with protective earth.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide
blade and the third prong are provided for your safety.
If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete
outlet.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience
receptacles, and the point where they exit from the
apparatus.
11. Only use attachments/accessories specified by the
manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the
apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury
from tip-over.
II
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate
normally, or has been dropped.
15. Do not place the equipment on any uneven or
unstable stand; original product package or
appropriate package should be used to avoid damage
caused by strong impacts during transportation.
16. Power supply cords:
AC 100 V-120 V 60 Hz or AC 220 V-240 V 50 Hz
17. The quantity of connected units in one system should
not exceed prescribed quantity. For service, please
contact the nearest TAIDEN Service Center.
18. Use ONLY specified connection cable to connect the
system equipment.
19. All TAIDEN products are guaranteed for definite time
(see the WARRANTY CARD for details) excluding the
following cases:
A. All damage or malfunction caused by human
negligence;
B. Damage or malfunction caused by improper
operating by operator;
C. Parts damage or loss caused by disassembling
the product by non-authorized personnel.
20. Upon receipt of the product, please fill out the
Warranty Card enclosed and post it to TAIDEN
Service Center nearby in your region.
CAUTION: To reduce the risk of electric shock,
DO NOT open covers, no user serviceable parts
inside. Refer servicing to qualified service
personnel only.
CAUTION: DO NOT use alcohol, ammonia or
petroleum solvents or abrasive cleaners to
clean the devices.
The lightning flash with an arrowhead symbol, with
an equilateral triangle, is intended to alert the user
to the presence of uninsulated ‘dangerous voltage’
within the products enclosure that may be of
sufficient magnitude to constitute a risk of electric
shock to persons.

Important Safety Instruction
The exclamation mark within an equilateral triangle
is intended to alert the user to the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.
III
Attention: Installation should be performed by
qualified service personnel only in accordance
with the National Electrical or applicable local
codes.
Power Disconnect: Units with or without ON – OFF
switch have power supplied to the unit whenever
the power cord is inserted into the power source;
however, the unit is operational only when the ON
– OFF switch is in the ON position. The power cord
is the main power disconnect for all units
WARNING: To reduce the risk of fire or
electric shock, DO NOT expose units to rain
or moisture.
WARNING: The apparatus should be
connected to a mains socket outlet with a
protective earthing connection.

Contents
Installation & User Guide........................................................................................................... V
Chapter 1. High Definition Digital Video Tracking Matrix Switchers............................................1
1.1 Functions and indications .................................................................................................................................1
1.2 Installation and connection ...............................................................................................................................2
1.2.1 Installation ..................................................................................................................................................2
1.2.2 Connection between Mixed Switcher and PC............................................................................................2
1.2.3 Connection with input, output devices .......................................................................................................2
1.3 Setup and Operation.........................................................................................................................................4
1.3.1 Menu setup ................................................................................................................................................4
1.3.2 Switch operation.........................................................................................................................................7
Chapter 2. IR Remote Control.................................................................................................. 10
Chapter 3. Communication protocol and control code.............................................................. 11
Chapter 4. Technical data.........................................................................................................13
IV

Installation & User Guide
About this manual
This manual is a comprehensive guide to the
installation and operation of TAIDEN SDI Series High
Definition Digital Video Tracking Matrix Switchers. It
includes: connection and operation, protocol and
control code, etc.
The manual is divided into the following chapters:
Chapter 1: High Definition Digital Video Tracking
Matrix Switchers
Descriptions in detail of the functions and indications,
installation and connection, configuration and operation
of High Definition Digital Video Tracking Matrix
Switchers.
Chapter 2: IR Remote Control
Introduction into the operation of IR remote control.
Chapter 3: Communication protocol and control
code
Detailed description of codes and their function.
Chapter 4: Technical data
Mechanical and electrical details of the High Definition
Digital Video Tracking Matrix Switchers.
This manual is applicable to:
TMX-0404SDI
4×4 High Definition Digital Video Tracking Matrix Switcher
(SD/HD/3G)
TMX-0804SDI
4×4 High Definition Digital Video Tracking Matrix Switcher
(SD/HD/3G)
TMX-0808SDI
4×4 High Definition Digital Video Tracking Matrix Switcher
(SD/HD/3G)
V

Chapter 1. High Definition Digital Video Tracking Matrix Switchers
1.1 Functions and indications
Figure 1.1 Panels of SDI Matrix Switcher
Front panel:
1. “MENU” button
a) If in current state, press “MENU” go to main
menu;
b) If in menu state, press “MENU” go to sub
menu;
c) Select/Deselect in network configuration.
2. “Õ” (Left) button
3. “Ö” (Right) button
4. “Exit” button
Return to previous directory or root.
5. IR receiving window
Receives the IR signals from remote control;
make sure the remote control aims at the
window.
6. “NETWORK” indicator
Indicator flashes if Matrix Switcher is
connected with PC software.
7. “ACTIVE” indicator
Indicator will be turned on if Matrix Switcher
executes switch instructions.
8. “POWER” indicator
Rear panel:
9. TAINET interface
10. RS-422/485 interface
11. Video inputs
12. Video outputs
13. CVBS output / synchronized loop out
14. Power cable interface
15. Grounding point
16. CVBS input / synchronized input
17. RJ45 interface
18. RS-232 communication interface COM1
1

2
1.2 Installation and connection
1.2.1 Installation
1U High Definition Digital Video Tracking Matrix
Switcher just needs to put it into the cabinet, and fix it
by screws. As figure 1.3.
Figure 1.3 Installation
1.2.2 Connection between Mixed Switcher and PC
High Definition Digital Video Tracking Matrix Switcher
can be can be controlled by Central Control System via
RS-232 interface COM1, this interface is also used for
software upgrade. As figure 1.4.
1.2.3 Connection with input, output devices
High Definition Digital Video Tracking Matrix Switcher
supports various digital video signal sources, including:
full HD (3G), HD and SD. As figure 1.4.
Please use good quality Twisted Pair cable to connect
input and output device, i.e. RG59 and RG60.
Control Interface:
Video Track Off
COM (RS-232) 9 pin female D connector
COM1 Baud rate: 9600, data: 8 bits,
stop: 1 bit, no parity check bit
RJ45 To matrix PC software
RS422/RS485、
TAINET Invalidation
Video Track On
COM (RS-232) 9 pin female D connector
COM1 Baud rate: 9600, data: 8 bits,
stop: 1 bit, no parity check bit
RJ45 Invalidation
TAINET Baud rate: 19200, to TO VIDEO
SWITCHER of main unit
RS422/RS485 Baud rate: 9600, to doom
camera
Note:
)If connected with camera by RS232 protocol,
the matrix switcher and the camera must be
common ground.

Figure 1.4 Connection example for input and output devices to TMX-0808SDI Matrix Switcher
3

1.3 Setup and Operation
1.3.1 Menu setup
1.3.1.1 Menu setup
To explain menu setup of SDI series Matrix Switcher,
TMX-0808SDI serves as example.
TMX-0808SDI main interface:
Press “MENU” to enter main menu and press “Õ/Ö”
until “Setting” prompts; Press “MENU” again to enter
setup menu, including:
1. Ring
2. COM2 Baud rate
3. Demo Switch Delay
4. COM1 protocol
5. Sync Switch Delay
6. Test button
7. Video Track
8. Video Track Type
Press “EXIT” to exit menu.
Menu 1 to menu 8 are explained explicitly:
1. Ring
Buzzer ring on-off of this unit. If buzzer ring is setup
“on”, the buzzer will ring when front panel operation,
PC software executing switch and receiving command
from central control system. The buzzer ring can be
setup “off”.
ON: open ;
OFF: close.
2. COM2 Baud rate
SDI series Matrix Switcher has no COM2 port, so this
item can’t be adjustable.
1. Press “MENU” to enter setup menu and
press “Õ/Ö” until “Setting” prompts;
2. Press “MENU” and press “Õ/Ö” until “Ring”
prompts;
3. Press “MENU” to enter setup;
4. Press “Õ/Ö” to select parameter;
5. Press “MENU” to confirm.
Setting
Ring
OFF
Ring
▋
OFF
Ring
ON
Ring
▋
ON
Note:
)When Video Tracking is off, RJ45 has
TCP/IP function.
)When Video Tracking is on, RJ45 is
Invalidation; camera protocol can be
selected from Video Track Type menu;
RS422/RS485 can be connected to control
doom camera; TAINET can be connected to
congress main unit.
)COM1 port can be connected to central
control system.
TMX-0808SDI
Version: 2.10
TMX-0808SDI
Version: 2.10
4

3. Demo Switch Delay 5. Sync Switch Delay
The interval ranges from 2 seconds to 60 seconds by
steps of 2 seconds.
4. COM1 protocol
Central control system can be selected from Taiden,
Extron or Other, Please add correct protocol according
to user request.
This item can’t be adjustable.
6. Test button
Tested button is working if character changes when
button is pressed.
7. Video Track
Select the function of video track on or off.
1. Press “MENU” and press “Õ/Ö” until
“Setting” prompts;
2. Press “MENU” and press “Õ/Ö” until
“COM1 protocol” prompts;
3. Press “MENU” to enter setup;
4. Press “Õ/Ö” to select parameter;
5. Press “MENU” to confirm.
Setting
COM1 protocol:
T
aiden
COM1 protocol:
▋
T
aiden
COM1 protocol:
Extron
COM1 protocol:
▋
Extron
TMX-0808SDI
Version: 2.10
1. Press “MENU” and press “Õ/Ö” until
“Setting” prompts;
2. Press “MENU” and press “Õ/Ö” until
“Demo Switch Delay” prompts;
3. Press “MENU” to enter setup;
4. Press “Õ/Ö” to adjust parameter;
5. Press “MENU” to confirm.
TMX-0808SDI
Version: 2.10
Setting
DemoSwitchDelay:
2 S
DemoSwitchDelay:
▋
2 *S
DemoSwitchDelay:
4 S
DemoSwitchDelay:
▋
4 *S
1. Press “MENU” and press “Õ/Ö” until
“Setting” prompts;
2. Press “MENU” and press “Õ/Ö” until
“Video Track” prompts;
3. Press “MENU” to enter setup;
4. Press “Õ/Ö” to adjust parameter;
5. Press “MENU” to confirm.
Setting
Video Track
OFF
Video Track
▋
OFF
Video Track
ON
Video Track
▋
ON
TMX-0808SDI
Version: 2.10
Note:
)The function of video track on will be enabled
after rebooting the matrix switcher.
5

8、Video Track Type
When Video Track is on, camera protocol can be
selected from HCS-3316RS232/ HCS-3316RS485/
SONY HD1/ PELCO D/ PELCO DC/ PELCO P1/
PELCO P2/ PANASONIC CS950/ PANASONIC
HE100/ SAMSUNG C6407P/ HCS-3313C/ SONY D70/
SONY D100/ SONY BRC-Z330/ SONY BRC300/
SONY BRC700. Please select correct protocol
according to actual device type.
1. Press “MENU” and press “Õ/Ö” until
“Setting” prompts;
2. Press “MENU” and press “Õ/Ö” until
“Video Track Type” prompts;
3. Press “MENU” to enter setup;
4. Press “Õ/Ö” to select parameter;
5. Press “MENU” to confirm.
Setting
Video Track Type
PELCO P1
Video Track Type
▋
PELCO P1
Video Track Type
PELCO P2
Video Track Type
▋
PELCO P2
TMX-0808SDI
Version: 2.10
6

1.3.2 Switch operation
To explain menu operation of SDI series Matrix
Switcher, TMX-0808SDI type serves as example. All
SDI series Matrix Switcher can refer to it.
TMX-0808SDI main interface:
Press “MENU” to enter switch menu, including:
1. Switch Video
2. Switch through
* Switch through one channel or all channels.
3. Close
* Close one output or all outputs.
4. Save scene
5. Recall scene
6. Undo
* Undo last switch.
7. Demo Switch
* Switch one by one.
8. Setting
* Setup menu.
9. Status
* Request channel state.
Menu 1 to menu 9 are explained explicitly:
1. Switch Video
Video switch key, switches one input video signal to
any or all output channels.
Example: Switch Video signal of input channel 1 to
output channel 8
1. Press “MENU” to enter menu;
2. Press “MENU” to enter “Switch Video”;
3. Press “MENU” to select input channel;
4. Press “Õ/Ö” to adjust input channel as “1”;
5. Press “MENU” to select output channel;
6. Press “Õ/Ö” to adjust output channel as “8”;
7. Press “MENU” to confirm and press “EXIT”
twice.
TMX-0808SDI
Version: 2.10
Switch Video:
Switch Video:
0
—
—>: 1
Switch OK !
Switch Video:
▋
1
—
—>: 1
Switch Video:
1
—
—>:
▋
8
Note:
)“Input channel” and “output channel” number
must be less than matrix type. For example:
TMX-08xxSDI series can only input number
1-8.
)If any menu item is edited, except setup
menu, a key must be pressed within 15
seconds otherwise the system will return to
main menu item automatically and erase the
previous channel setup.
)To return to main menu press any key if
currently editing user interface is switch finish
interface, display input, output status
interface or DEMO interface. To return to
main menu if editing other user interface
press “EXIT” or “Õ”.
TMX-0808SDI
Version: 2.10
Note:
)If input channel displays “0”, output channel is
closed.
)If output channel displays “ALL”, input channel
is switched to all output channels.
7

2. Switch through
Switch through one input channel or all input channels
to corresponding output channel(s).
Example: Switch through channel 2.
3. Close
Close one output channel or all output channels.
Example: Close output channel 2.
4. Save scene
Save current video signal to appointed scene. 10
scenes can be saved at most, each scene has a
number, from 0 to 9.
Example: Save scene 3
5. Recall scene
Recall video signal from selected scene.
Example: Recall scene 3
1. Press “MENU”, and press “Õ/Ö” until
“Recall scene” prompts;
2. Press “MENU” to enter “Recall scene”;
3. Press “Õ/Ö” select scene number “3”;
4. Press “MENU” to confirm.
TMX-0808SDI
Version: 2.10
Recall scene:
Recall scene:
▋
0
Switch OK !
3
Recall scene:
▋
3
1. Press “MENU” and press “Õ/Ö”until “Save
scene” prompts;
2. Press “MENU” to enter “Save scene”;
3. Press “Õ/Ö” to select scene number “3”;
4. Press “MENU” to confirm.
TMX-0808SDI
Version: 2.10
Save scene:
Save scene:
▋
0
Save scene OK !
3
Save scene:
▋
3
1. Press “MENU” and press “Õ/Ö” until
“Close” prompts;
2. Press “MENU” to enter “Close”menu;
3. Press “Õ/Ö” to select channel “2”;
4. Press “MENU” to confirm.
TMX-0808SDI
Version: 2.10
Close
Close
▋
1
Switch OK !
2
Close
▋
2
1. Press “MENU” and press “Õ/Ö” until
“Switch through” prompts;
2. Press “MENU” to enter “Switch through”;
3. Press “Õ/Ö” to select channel “2”;
4. Press “MENU” to confirm.
TMX-0808SDI
Version: 2.10
Switch through:
Switch through:
▋
1
Switch OK !
2
Switch through:
▋
2
Note:
)Select “All ”standing for switch through all
channels.
Note:
)Select “ALL” stands for closing all channels.
8

6. Undo
Undo last switch operation.
7. Demo Switch
Switches one by one all possible combinations from 1
→1, 1→2, …, 1→8, 2→1, 2→2, …, 2→8, …, 8→1, 8→
2, …to 8→8. The interval can be setup via setup menu
(Refer to section 1.3.1).
8. Setting
Setup menu.
9. Status
Request corresponding state of input and output
channels.
1. Press “MENU” and press “Õ/Ö” until
“Demo switch” prompts;
2. Press “MENU” to execute.
TMX-0808SDI
Version: 2.10
Demo switch:
Demo switch:
1. Press “MENU”, and press “Õ/Ö”until
“Undo” prompts;
2. Press “MENU” to execute.
TMX-0808SDI
Version: 2.10
Undo
Switch OK !
1. Press “MENU” and press “Õ/Ö” until
“Setting” prompts;
2. Press “MENU” to enter setup status. Refer
to section 1.3.1 for details.
TMX-0808SDI
Version: 2.10
Setting
SyncSwitchDelay:
0 *ms
1. Press “MENU” and press “Õ/Ö” until
“Status” prompts;
2. Press “MENU” to request corresponding
status;
3. Press “Õ/Ö” to request next status.
TMX-0808SDI
Version: 2.10
Status
Video: 3 →:1
Video: 5 →:2
9

Chapter 2. IR Remote Control
1. Basic function
Users can use remote control to operate matrixes, the function of
remote control key is the same as matrix front panel key (Please refer
to chapter 1 for detailed instructions).
Please refer to sections of menu operation for detailed operation
method of remote control key.
2. Camera function
For the matrix with and has opened the video tracking function, users
can use remote control to operate the cameras which connected to the
matrix. The functions of camera operate as below:
1) Camera control
a. press the yellow button to enter the menu:
Camera Control
0
b. select a camera ID (1 to 8 buttons);
c. use the following buttons to adjust the camera;
Button Function Button Function Button Function
◄Left STATUS Up Green Magnify
►Right CLOSE Down Red Lessen
d. press the “CANCEL” button to exit.
2) Camera scan
a. press the blue button to enter the menu:
Camera Scan
0
b. select a camera ID (1 to 8 buttons);
c. use the following buttons to control the direction of the camera;
Button Function Button Function
1 Frame scan
(between preset 30 and 31) 2 Auto cruise
3 scan 300°4 scan 180°
d. press the “CANCEL” button to exit.
The remote control can be used for all TAIDEN matrix main units with
IR receipt function.
10

Chapter 3. Communication protocol and control code
This code system is used for controlling and operating
TAIDEN professional Matrix Switchers by central
control system or user programming software.
Protocol: Baud Rate: 9600; Data: 8 bits; Stop: 1 bit;
Parity Check Bit: No
Type Code Description
Lock; Lock keyboard
Unlock; Unlock keyboard
BeepOff; Beep off
BeepOn; Beep on
TAIDEN; Select COM1 protocol to be TAIDEN;
EXTRON; Select COM1 protocol to be EXTRON;
System Code
OTHER; Select COM1 protocol to be OTHER;
If central control system does not execute switch within 15 s after input channel, TMX main unit cleans up
channel automatically.
0xd9 0xe1 [x1] [x2] Video of input channel [x1] switch to output channel [x2]. If input channel [x1] is 0,
output channel [x2] will be closed.
0xd9 0xe2 [x1] [x2] Audio of input channel[x1] switch to output channel [x2]. If input channel [x1] is 0,
the output channel [x2] will be closed.
0xd9 0xe3 [x1] [x2] Video and audio of input channel [x1] switch to output channel [x2]. If input channel
is 0, the output channel [x2] will be closed.
0xd9 0xe4 [x1] e9 Video of input channel [x1] switch to all output channels
0xd9 0xe5 [x1] e9 Audio of input channel [x1] switch to all output channels
0xd9 0xe6 [x1] e9 Video and audio of input channel [x1] switch to all output channels
0xd9 0xec 0x01 0x00 Close all output channels
0xd9 0xeb 0x03 0x00 Go through from all input channels to corresponding output channels
0xd9 0xed 0x02 0x00 Execute switch
0xd9 0xe7 0xe7 scene Save corresponding relation to scene 0,1,2…9
0xd9 0xe8 0xe8 scene Recall scene XX
0xd9 0xe9 0xe9 scene Clear scene XX
0xd9 0xc1 0xc1 0x00 Query the matrix type
0xd9 0xc2 0xc2 0x00 Query the input status of all output channels
Operation Code (TAIDEN)
0xd9 0xc4 [x1] 0x00 Query the input status of the output channel [x1]
[x1]All. Input channel [x1] switch to all output channels
All#. Setup all channels one-to-one correspondence: 1->1, 2->2, 3->3…
All$. Close all channels
[x1]#. Input channel [x1] switch to output channel [x1]
[x1]$. Close output channel [x1]
[x1]V[x2]. Video of input channel [x1] switch to output channel [x2]
[x1]V[x2],[x3],[x4]. Video of input channel [x1] switch to output channel [x2], [x3], [x4]
[x1]A[x2]. Audio of input channel [x1] switch to output channel [x2]
[x1]A[x2],[x3],[x4]. Audio of input channel [x1] switch to output channel [x2],[x3],[x4]
[x1]B[x2]. Video and audio of input channel [x1] switch to output channel [x2]
Operation Code (OTHER)
[x1]B[x2],[x3],[x4]. Video and audio of input channel [x1] switch to output channel [x2],[x3],[x4]
11

Save[X]. Save current status to scene [X]
Recall[X]. Recall scene X]
Clear[X]. Clear scene [X], status of all output channel are closed
Type*. Query the matrix type
Status[x1]. Query the input status of the output channel [x1]
Status. Query the input status of all output channels
[X1]*[X2]! Video and audio of input channel [x1] switch to output channel [x2]
[X1]*[X2]$ Audio of input channel [x1] switch to output channel [x2]
[X1]*[X2]% Video of input channel [x1] switch to output channel [x2]
EXTRON;
[X1]*[X2]& Input channel [x1] switch to output channel [x2]
Note:
)[x1], [x2], [x3], [x4] is channel number of input or output; only 1~8 available, otherwise regarded as error.
)“[“ and ”]” do not send code;
)End each command by code such as “.”, “;”.
Command examples:
1. System code: TAIDEN; EXTRON; OTHER;
For example: convert a TAIDEN code system unit
to a EXTRON code system unit, run “EXTRON;”,
then the unit will only support code ends with
“!$%&”.
2. [x1]All.
For example: Input channel 3 switch to all output
channels, code is “3All.”.
3. All#.
Setup all channels one-to-one correspondence:
1->1, 2->2, 3->3…8->8.
4. All$.
Close all output channels.
5. [x]#.
For example: Input channel 5 switch to output
channel 5, code is “5#.”.
6. [x]$.
For example: Close output channel 5, code is
“5$.”.
7. [x1]V[x2].
For example: Video of input channel 3 switch to
output channel 5, code is “3V5.”. Video of input
channel 3 switch to output channel 8, 9, 12, code
is “3V8,9,12.”.
8. [x1]A[x2].
For example: Audio of input channel 10 switch to
output channel 2, code is “10A2.”. Audio of input
channel 10 switch to output channel 2, 5, 6, code
is “10A2,5,6.”.
9. [x1]B[x2].
For example: Video and audio of input channel 1
switch to output channel 2, 3, 5, code is “1B2,3,5.”.
10. Save[x].
For example: Save current status to scene 7, code
is “Save7.”.
11. Recall[x].
For example: Recall scene 5, code is “Recall5.”.
12

13
Chapter 4. Technical data
Type
Spec. TMX-0404SDI TMX-0804SDI TMX-0808SDI
Video
Date rates 143 Mbps - 2.97 Gbps
Date types 8 bit or 10 bit
Video input
Connectors 4 × BNC female 8 × BNC female
Input cable equalization
Typical equalization cable length (Belden 1694A standard cable):
100 m @ 2.97 Gbps
200 m @ 1.485 Gbps
400 m @ 270 Mbps
Input level 0.7 V - 1.2 Vp-p
Nominal level 0.8 Vp-p
Impedance 75 Ohm
Return loss 20 dB - 30 dB @ 5 MHz to 1.5 GHz
Video output
Connectors 4 × BNC female 8 × BNC female
Nominal level 0.8 V±7%
Output level 0.5 V - 1.6 Vp-p
Impedance 75 Ohm
Return loss >15 dB @ 5 MHz to 1.5 GHz
DC offset ± 100 mV with no offset at input
Jitter 20 ps - 30 ps @ HD/3G rate
40 ps - 60 ps @ SD rate
Rise and fall time
(20~80%) SD: 600 ps
HD/3G: 100 ps
Control
Video track off:
COM (RS-232) RS-232, 9 pin female D connector
COM1 Baudrate: 9600, data: 8 bits, stop: 1 bit, no parity
RJ45 TCP/IP
RS422/RS485/TAINET Invalidation
Video track on:
COM (RS-232) RS-232, 9 pin female D connector
COM1 Baudrate: 9600, data: 8 bits, stop: 1 bit, no parity
RJ45 Invalidation
TAINET Baudrate: 19200, to main unit
RS422/RS485 Baudrate: 9600, to dome camera

14
Type
Spec. TMX-0404SDI TMX-0804SDI TMX-0808SDI
General spec.
Power supply 100 V AC - 240 V AC,50/60 Hz
Temperature Operating: 0 °C to + 50 °C; storage: -20 °C to + 70 °C
Humidity Storage and operating: 10% to 90%
Dimensions h × w ×d
(mm) 483×208×43 (1U high, full rack width)
Weight 2.7 kg
Mean time between
failures 30,000 hours
This manual suits for next models
2
Table of contents
Other Taiden Switch manuals