TBB power BM Series User manual

BM battery monitor manual
TBB POWER CO., LTD.
BM
Battery Monitor Manual
Version: A1.0
April. 2017

BM battery monitor manual
TBB POWER CO., LTD.

BM battery monitor manual
TBB POWER CO., LTD.
WARNING : FIRE HAZARD
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER
NON- COMBUS TABLE SURFACE ONLY
CAUTION : THE DC AND AC BREAKER MUST HAVE BEEN
TURNED OFF BEFORE SERVICING
MADE IN CHINA

BM battery monitor manual
TBB POWER CO., LTD.
Disclaimer
Unless specially agreed in writing, TBB Power Co.,Ltd
Take no warranty as to the accuracy, sufficiency of suitability of any technical or other
information provided in this manual or other documentation.
Assumes no responsibility or liability for loss or damage, whether direct, indirect,
consequential or incidental, which might arise out of the use of such information
About this Manual
This manual describes our product features and provides procedure of installations. This manual
is for anyone intending to install our equipment.
General Description
Thanks for choosing TBB product.
The BM series battery monitor features microprocessor controlled combined with high resolution
measuring system for Lead Acid battery voltage and charge/discharge current. With built in
software, BM series can calculated consumed AH/KWH and remaining AH/KWH, and display
battery voltage and battery current as well.
BM could record all battery activities since the first installation (max 200 records). Apart from
discharging and charging, multiple other factors are considered including battery size, age ratio
of battery etc. With shunt, even the smallest leakage current can be detected and recorded to
guarantee the accuracy.
Compared with conventional indicating meters, small current can be measured and read exactly
with this device. With this feature, latent consumers (insulation fault, wrong connections,
standby unit etc) can be recognized immediately. Meantime, through additional sensor second
battery voltage can be measured and displayed.
With the optional DOD protection unit, battery low voltage protection level can be programmed
and alarm cam will be sent once reaching the limit to avoid battery damage due to deep
discharge. In the meantime, it can be used to drive the battery protection device to shut off the
battery against further discharge.
Battery voltage of service battery
Battery current : charging and discharging
Battery residual capacity in AH
Battery capacity in %
Programmable for protection point
RS485 is available
Available model: 100A, 200A and 400A.

BM battery monitor manual
TBB POWER CO., LTD.
Schematic diagram
Voltage and
Current
Sampling
BM Monitor
DOD
Protection
RS485
Model Name
BM XXX Y
Item
Description
BM
BM
Battery monitor for lead acid battery
XXX
100
The max current for battery
monitor
100A
200
200A
400
400A
Y
for 12V/24V system self-adaption
S
for 48V system
Available model
Model
Max Current
Battery voltage
comments
BM100
100A
12Vdc/24Vdc
12Vdc/24Vdc self-adaption
BM100S
100A
48Vdc
BM200
200A
12Vdc/24Vdc
12Vdc/24Vdc self-adaption
BM200S
200A
48Vdc
BM400
400A
12Vdc/24Vdc
12Vdc/24Vdc self-adaption
BM400S
400A
48Vdc

BM battery monitor manual
TBB POWER CO., LTD.
Optional DOD model:
Compatible for
12Vdc
24Vdc
48Vdc
50A
RY50L
/
/
100A
CR100L/RY100L
CR100M
CR100S
200A
CR200LM
CR200LM
CR200S
400A
CR400L
CR400M
CR400S
Components
Monitor Module
Current Detector Module
SS (for 100A,200A model)
Current Detector Module
SH (for 400A model)

BM battery monitor manual
TBB POWER CO., LTD.
Dimension and Hole size
Monitor Module
101
101
43.45
35.6
4-φ3.5
43.1
101
81
87.64
87.64
SS
135
31.4
28
59
111
14
6
31.4
59
50
17
100

BM battery monitor manual
TBB POWER CO., LTD.
SH

BM battery monitor manual
TBB POWER CO., LTD.
Installation Preparation
Material list

BM battery monitor manual
TBB POWER CO., LTD.
Item
Qty
Description
1
1
Front panel of Monitor Module
2
1
Monitor Module
3
1
Mounting holder
4
1
SS current detector
5
1
SS plate
6
1
Cable for service battery, Cable-Service-Batt-Volt/01
7
3
Screws for mounting holder of the monitor,M3x12mm
8
2
Screws for SS, M6 x 25mm
9
5
Screws for monitor, M3x25mm
10
5
Screw fixing expansion sleeve 4mm
11
1
Connection cable between SS and battery negative, Cable-Flex-50/30 or
Cable-Flex-25/30
12
1
Cable for starter battery, Cable-Starter-Batt‐Volt/01
13
1
Connection cable between SS and monitor, Cable-BM/03

BM battery monitor manual
TBB POWER CO., LTD.
Connector Description
Monitor Module
A
RS485 Communication (white)
COM
B
Comm. port for battery energy information (black)
BM
C
Comm. for DOD
DOD
D
Cable fastener
Current Detector Module - SS
Take off the cover, you will see the connector of the SS.
A
Load -
B
BM comm.Cable connector
C
BAT-

BM battery monitor manual
TBB POWER CO., LTD.
Cable preparation
Please prepare the following cables for installation
Model
lenght
comments
Cable-BM/03
3
The standard
Cable-Service-Batt-Volt/01
1
The standard
Cable-Starter-Batt-Volt/01
1
The standard
Cable-L8-D/03
3
for BML1008/BML2008
Cable-L4-D/03
3
for BML1004/BML2004
Cable-Flex-50/30
0.3
for SS200/SS200S
Cable-Flex-25/30
0.3
for SS100/SS100S
Cable-BM/03
T1
To Connect to SS or SH
T2
To Port BM of the monitor module
T3
To connect Cable-Starter-Batt‐Volt/01
T4
To connect Cable-Service-Batt-Volt/01
1
2
3
5
4
1
2
3
4
T1 To Shunt
T2 TO Monitor-BM
T3 Starter-Batt+
T4 Service-Batt+
橙
棕
绿
蓝
紫
白
红
黄
灰
红
红
灰
橙
棕
绿
蓝
紫
白
红
黄

BM battery monitor manual
TBB POWER CO., LTD.
Cable-Service-Batt-Volt/01
T2:Service Batt+
T1
T1
To Connect to Service batt +
T2
To connect to Cable-BM/03
Cable-Starter-Batt-Volt/01
T2: Starter Batt+
T1
T1
To Connect to Starter batt +
T2
To connect to Cable-BM/03
Cable-Flex-50/30 or Cable-Flex-25/30
Cable-Flex-50/30 and Cable-Flex-25/30 are to connect between battery negative connector and
BAT- connector of current detector module (SS or SH).
T1 T2

BM battery monitor manual
TBB POWER CO., LTD.
Installation Request
Work temperature: -20~60℃Storage temperature:-40~85℃
Cooling: Natural cooling Humility: 0%-95% non-condensing
Install the unit at the location where has well ventilation.
Recommended working temperature is 0~25℃
Recommended humility is around 50%
Installation
Professional electrical technician is required for the installation.
Please make sure BM is powered off during the installation which means the connection between
Cable-BM/03 and Cable-Starter-Batt-Volt/01 BAT+ / Cable-Service-Batt-Volt/01 S-BAT+ is the last
step of the installation.
Please make sure all of the equipments are powered off during the installation.
The location of SS/SH is recommended to be as close as possible to the battery. Shorter cable
between SS/SH and battery is better.

BM battery monitor manual
TBB POWER CO., LTD.
Monitor Module
Mounting holder is optional accessary. Please consult to the distributor or TBB Power if you need
it.
Installation with the mounting holder
Installation without the mounting holder
82+2
-0
82+2
-0
87.6±0.50
87.6±0.50
4-? 4.5(H=35)
The Wall Hole Size
4-Φ4*Φ5*24
4-M4*25
2,80
2,80
87.6±0.50
87.6±0.50
2‐φ4.5(H=35)
TheWallHoleSize
2‐φ4*φ5*24
2-M3*25
2-M3*10 61,94
82+2
-0
82 +2
-0
87.6±0.50
87.6±0.50
4‐φ4.5(H=35)
TheWallHoleSize
4‐φ4*φ5*24
4-M4*25 2,80
2,80

BM battery monitor manual
TBB POWER CO., LTD.
SS/SH Installation
Connection to battery groups.
111,00
Φ3.50
Wall Openings
+
12V
100Ah
-
BAT+
12V
12V/100Ah
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
12V/400Ah
+
12V
100Ah
-
BAT+
24V
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
24V/100Ah 24V/200Ah
BAT-
BAT+
12V
BAT+
24V
BAT-
BAT-
BAT-
Cable-SG-050/30
orCable-SG-025/30
Cable-SG-050/30
orCable-SG-025/30
Cable-SG-050/30
orCable-SG-025/30
Cable-SG-050/30
orCable-SG-025/30
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
48V/400Ah
BAT-
Cable-Flex-50/30
Cable-Flex-25/30
BAT+
48V

BM battery monitor manual
TBB POWER CO., LTD.
SH Installation.
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
+
12V
100Ah
-
12V/400Ah
BAT+
12V
BAT-
DEVICE-

BM battery monitor manual
TBB POWER CO., LTD.
Operation
First power on
1. Confirm the connections are correct as the manual guided and fastened.
2. Connect Cable-Starter-Batt- Volt/01and Cable-BM/03.
3. Connect Cable-Service-Batt-Volt/01 and Cable-BM/03.
BM is powered on after the above steps.
4. Initial settings for BM.
a) Set battery type and capacity.
b) Set System datetime and installation datetime.
c) Battery capacity correction. Use a proper battery charger to charge the battery until
there is no alarms on the BML display.
d) Any change of the battery type or battery capacity setting needs a repeat for step b)
and c)
DO NOT plug out any connectors on the BM during it is working.
Power Off
a) If there is starter battery connected, disconnect the cable connect with the
starter battery first, then disconnect the cable connected to the service
battery,Cable-Service-Batt-Volt/01 and Cable-BM/03 to complete the shut down
of BM.
b) If there is no starter battery connected, disconnect disconnect the cable
connected to the service battery, Cable-Service-Batt-Volt/01 and Cable-BM/03 to
complete the shut down of BM.

BM battery monitor manual
TBB POWER CO., LTD.
Display
BM Menu
Click “Enter”
To Enter The Main Menu
Status >
Setting
Event
Information
Active Alarm
System’s Status Information
System’s Setting Information
Current Alarm Information
Event Logs
Hardware/Software Information
Home Page The First Level Menu
13.0V
-2.0A
100Min
65 Cyc
56%
03/12/2015 07:51:34
SERVICE:
CUR:
CYCLES:
STARTER:13.1V
1. Home page
Current Date
Battery SOC
Active Alarm
Remain Time Of Battery
Charging/Discharging Status
Battery Voltage
Battery Current
Charging/Discharging Cycles
Current Time
13.0V
-2.0A
100Min
65 Cyc
56%
03/12/2015 07:51:34
SERVICE:
CUR:
CYCLES:
STARTER:13.1V Battery Service Voltage
“Active Alarm”is ON, means the battery capacity correction is not completed.
“Active Alarm”is flashing, means the battery capacity correction is completed with
alarms. Please consult the technician.
“Active Alarm”is OFF, means the battery capacity correction is completed successfully.

BM battery monitor manual
TBB POWER CO., LTD.
2. Status
Status >
Setting
Event
Information
Active Alarm
01 0101HomepPage
Voltage 13.0V
Current -2.0A
SOC 52%
RE Time 100Min
Cycles 65 Cycles
Battery Monitor
13.0V
-2.0A
100Min
65 Cyc
56%
03/12/2015 07:51:34
SERVICE:
CUR:
CYCLES:
STARTER:12.0V
0101
Voltage 13.0V
Current -2.0A
SOC 52%
RE Time 100Min
Cycles 65 Cycles
Battery Monitor
SOC: Battery State of Charge , 0%~100%
Voltage: Battery Voltage
Current:Battery current. “-”means discharged current.
Without “-”means charging current.
Cycles: Battery cycles
RE Time: Battery left to go.