1. Important safety instructions
Some terminals carry electrical current of sufficient magnitude to constitute a risk of
electric shock. Use only high-quality commercially-available speaker cables with ¼” TS
plugs pre-installed. All other installation or modification should be performed only by
qualified personnel.
This symbol, wherever it appears, alerts you to the presence of ininsulated
dangerous voltage inside the enclosure – voltage that may be sufficient to
constitute a risk of shock.
This symbol, wherever it appears, alerts you to important operating and
maintenance instructions in the accompanying literature. Please read the manual
To reduce the risk of electric shock, do not remove the top cover (or the rear section). No
user serviceable parts inside. Refer servicing to qualified personnel.
These service instructions are for use by qualified service personnel only. To
reduce the risk of electric shock do not perform any servicing other than that
contained in the operation instructions. Repairs have to be performed by qualified
service personnel.
1. READ THESE INSTRUCTIONS
All the safety and operating instructions should be read before the product is operated.
2. KEEP THESE INSTRUCTIONS
The safety and operating instructions should be retained for future reference.
3. HEED ALL WARNINGS
All warnings on the product and in the operating instructions should be adhered to.
4. FOLLOW ALL INSTRUCTIONS

TECNARE DPA 28X OWNER’S MANUAL
All operating and use of instructions should be followed.
5. DO NOT USE THIS APPARATUS NEAR WATER
Do not use the product near water. For example, near a bathtub, washbowl, kitchen sink,
or laundry tub, in a wet basement, or near a swimming pool.
6. CLEAN ONLY WITH DRY CLOTH
Unplug the unit from the wall outlet before cleaning. Do not use liquid cleaners or aerosol
cleaners. Use a damp cloth for cleaning.
7. DO NOT BLOCK ANY VENTILATION OPENINGS
Slots and openings in the cabinet back or bottom are provided for ventilation, to ensure reliable
operation of the limit and to protect it from overheating. These openings must not be blocked or
covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or
similar surface. This product should never be placed near or over a radiator or heat source. This
product should not be placed in a built-in installation such as a bookcase or rack unless proper
ventilation is provided or the manufacture's instructions have been adhered to.
8. DO NOT INSTALL NEAR ANY HEAT SOURCES
This Product should be situated away from heat sources such as radiators, stoves, or other
products (including amplifiers) that produces heat.
9. DO NOT DEFEAT THE SAFETY PURPOSE OF THE POLARIZED OR GROUNDING-
TYPE PLUG
A Polarized plug has two blades with one wider than the other. A grounding-type plug has two
blades and a third grounding prong. The wide blade or the third prongs are provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of
the obsolete outlet.
10. PROTECT THE POWER CORD FROM BEING WALKED ON OR PINCHED
PARTICULARLY AT PLUGS, CONVENIENCE RECEPTACLES, AND THE POINT
WHERE THEY EXIT FROM THE APPARATUS.

TECNARE DPA 28X OWNER’S MANUAL
11. ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE
MANUFACTURER.
12. USE ONLY WITH CART, STAND, TRIPOD, BRACKET, OR TABLE SPECIFIED BY
THE MANUFACTURER, OR SOLD WITH THE APPARATUS. WHEN A CART IS USED,
USE CAUTION WHEN MOVING THE CART/APPARATUS TO AVOID INJURY FROM
TIP-OVER.
Do not place this unit on an unstable cart, stand, tripod, bracket, or table. The unit may fall,
causing serious injury to someone, and serious damage to the appliance. A unit and cart
combination should be moved with care. Quick stops, excessive force, and uneven surfaces may
cause the product and cart combination to overturn.
13. UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED
FOR LONG PERIODS OF TIME.
For added protection for this unit during a lightning storm, or when it is left unattended and unused
for long periods of time, unplug it from the wall outlet and disconnect the antenna or cable system.
This will prevent damage to the unit due to lightning and power line surges.
14. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL. SERVICING IS
REQUIRED WHEN THE APPARATUS HAS BEEN DAMAGED IN ANYWAY, SUCH AS
WHEN THE POWER SUPPLY CORD OR PLUG IS DAMAGED, LIQUID HAS BEEN
SPILLED OR OBJECTS HAVE FALLEN INTO THE APPARATUS, THE APPARATUS
HAS BEEN EXPOSED TO RAIN OR MOISTURE, DOES NOT OPERATE NORMALLY,
OR HAS BEEN DROPPED.
15. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
16. APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO
OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE
APPARATUS.

TECNARE DPA 28X OWNER’S MANUAL
TABLE OF CONTENTS:
TABLE OF CONTENTS:.................................................................................................5
1 INTRODUCTION..........................................................................................................6
2 SHIPPED CONTENT...................................................................................................6
- DPA - 28X unit.......................................................................................................6
- User Manual...........................................................................................................6
3 FEATURES..................................................................................................................6
4 FRONT PANEL FUNCTIONS......................................................................................7
5 REAR PANEL FUNCTIONS.........................................................................................8
TECNARE PCC CONTROLLER ADVANCED SERIES USER MANUAL .......................9
1.- INSTALLATION..........................................................................................................9
1.1.- SOFTWARE INSTALLATION..............................................................................9
1.2.- SETUP THE PC COMMUNICATION ..................................................................9
2.- USING THE PCC CONTROLLER ADVANCED SERIES...........................................9
2.1 Overview................................................................................................................9
2.2 MENU BAR..........................................................................................................10
2.3 NETWORK WINDOW..........................................................................................11
2.4 INPUT SECTION.................................................................................................12
UNIT ID AND GROUPING.....................................................................................12
SIGNAL GENERATOR..........................................................................................13
INPUT LEVEL........................................................................................................13
INPUT COMPRESSOR .........................................................................................14
GENERAL SETUP.................................................................................................15
GRAPHIC EQUALIZER .........................................................................................20
2.5 OUTPUT SECTION.............................................................................................20
CROSSOVER........................................................................................................22
PARAMETRIC EQ .................................................................................................23
LIMITER.................................................................................................................24
LEVEL/DELAY.......................................................................................................24

TECNARE DPA 28X OWNER’S MANUAL
1 INTRODUCTION
The DPA 28X is a complete 2 input - 8 output digital loudspeaker management system
designed for the touring or fixed sound installation markets. The absolute latest in
available technology is utilized with 64-bit floating point processors and high performance
24-bit Analogue Converters. The high-bit DSP prevents noise and distortion induced by
truncation errors of the commonly used 24-bit fixed-point devices. A complete set of
parameters include I/O levels, delay, polarity, 8 bands of parametric EQ per channel,
multiple crossover selections, compressor, Limiter, USB and Ethernet port connection.
Precise frequency control is achieved with its 1 Hz resolution.
The DPA - 28X can be controlled or configured in real time on the front panel using the
previously stored presets or with the intuitive PC software via the USB or Ethernet
interface. The Ethernet port allows controlling the device from a long distance using just
an Internet connection.
2 SHIPPED CONTENT
- DPA - 28X unit
- User Manual
- Software CD: Tecnare PCC controller Advanced Series.
3 FEATURES
•2 Input and 8 Outputs.
•64 Bits floating point DSP
•High performance 24-bit A/D Converters
•1 Hz Frequency Resolution
•Storage of up to 10 program setups
•Unlimited number of presets via software
•Uploading of 10 collection presets in one step via software
•USB port connection.
•Ethernet port connection

TECNARE DPA 28X OWNER’S MANUAL
•30 bands Input graphic equalizer.
•8 bands Output Parametric equalizer per output channel
•4 ways configurable Crossover
•Main Delay
•Input and output Compressor and Limiter
•Configurable Clock
•Noise Generator
•Sound Analyzer
•Phase inverter per band
•Mute
•Via adjustable delay
4 FRONT PANEL FUNCTIONS
1.- LCD Screen CH-A: Show all the necessary information to control de unit
1.- Unit name
2.- Shows the preset number and identification.
3.- ID of the Unit.
I B Z A 6
I B Z A 6I B Z A 6
I B Z A 6
I D : 0 1
I D : 0 1I D : 0 1
I D : 0 1
P 0 1
P 0 1P 0 1
P 0 1
d e f a u l t
d e f a u l td e f a u l t
d e f a u l t
1 2
3
4 5
6 7 8
9
2
1
2

TECNARE DPA 28X OWNER’S MANUAL
2.- Rotary thumb wheel CH-A: Controls the presets. To select the desire preset, press
the wheel.
3.- On / SIGNAL / CLIP led CH-A: When On indicate the unit is On, Signal at the input
and the input level is above the device´s maximum headroom respectively.
4.- LCD Screen CH-A: Show all the necessary information to control de unit
5.- Rotary thumb wheel CH-A: Allows you to switch between presets. To select the
desire preset, press the wheel.
6.- On / SIGNAL / CLIP led CH-A: When On indicates the unit is On, Signal at the input
and the input level is above the device´s maximum headroom respectively.
7, 8.- Ethernet connector: Standard RJ-45 female socket.
9.- Power switch: Controls power On/Off.
5 REAR PANEL FUNCTIONS
1.- Main Power: Connects via a standard IEC socket. A compatible power cord is
supplied with the unit. The voltage input is either 115VAC or 230VAC and is clearly
specified on the unit. Voltage requirement has to be stated upon ordering.
2, 3.- XLR input and outputs: Separate 3-pin XLR connectors are provided for each
audio input and output. The device's output stage employs the balanced impedance
topology. All I/O connectors have pin 1 as ground (shield), pin 2 as + and pin 3 as –
4.- USB connectos: USB connector per channel for PC connection.
1 2 3
4

TECNARE DPA 28X OWNER’S MANUAL
TECNARE PCC CONTROLLER ADVANCED SERIES USER
MANUAL
1.- INSTALLATION
1.1.- SOFTWARE INSTALLATION.
1.- Click on Pcc12G_Setup.exe icon
2.- Follow the wizard instruction (for default installation you can press NEXT until the
end)
* The estimated time required for first installation is about 1 minute.
* If asked by the wizard, restart the computer
1.2.- SETUP THE PC COMMUNICATION
1.- Connect the unit to the PC using the provided USB cable.
2.- USING THE PCC CONTROLLER ADVANCED SERIES
2.1 Overview
The Tecnare PCC Controller advanced series software application provides real-time
control and configuration editing for the DPA-28X using a laptop or other PC-compatible
computer.
In addition, the application provides control over each individual input channel: Gain,
Graphic EQ, Compressor, main delay, and over each individual output channel:
Crossover, 8 bands parametric EQ, phase inverter, mute, and delay.
In addition, the application provides a powerful real time analyzer with pink noise
generator capability.
Changes made in the PC software are immediately executed in the DPA-28X.
To start the application click on the PCC Icon on your desktop

TECNARE DPA 28X OWNER’S MANUAL
It will appear a screen as is in the following image:
Open the Connect dropdown list and select On Line, this will connect your unit to your
PC.
The user interface is divided into 4 sections:
- Menu Bar
- Network window
- Input section
- Output section
2.2 MENU BAR
The following menus are available in the Menu Bar at the top of the screen
FILE
- Load Preset: Click this option to Load an existing preset from your computer
- Save Preset: Save the current preset to a file
- Load Set: Click this option to Load a Set of 10 preset from your computer
- Save Set: Save the current set of 10 presets to a file.
- Exit: Exit the application
CONNECT
- On line: Connects the computer to the unit.

TECNARE DPA 28X OWNER’S MANUAL
DELAY UNITS
- ms
- meter
- feet
2.3 NETWORK WINDOW
When the PC is connected to the unit, the following information is shown at the upper left
corner of the screen.
Temperature: It shows the temperature of each output channel.
Limiter: The limiter light show up when the audio limiter is acting.
Signal Inidicator: When lighting a input signal is present.
Temperature
Limiter
Signal

TECNARE DPA 28X OWNER’S MANUAL
2.4 INPUT SECTION
This section contains the following modules:
- Unit ID and grouping.
- Signal Generator
- Input Level
- Input Compressor
- General Setup
- 30 bands Graphic equalizer
UNIT ID AND GROUPING
It shows the units information connected to the PC, the active one is the one on Red.
Double click to activate the unit.
By clicking on the group ID box, the user will be able to assign each unit to a group.
Unit name
Unit ID
Group

TECNARE DPA 28X OWNER’S MANUAL
SIGNAL GENERATOR
By selecting active in the dropdown list, a pink noise signal is generated by the 8 output
channels.
The output level is controlled by the fader control.
INPUT LEVEL
Main delay in ms, meters or feet can be adjusted in this section. The input level is
adjusted by the fader control, it provides signal and clipping indicators.

TECNARE DPA 28X OWNER’S MANUAL
INPUT COMPRESSOR
The input compressor has four controls: Attack, Release, Threshold and Ratio. Click on
the dropdown list to adjust each parameter. Click the Bypass button to turn it off.
About Compression: A compressor is used to reduce or limit transient peaks in a signal.
As the input level to the compressor increases, the output level increases linearly until the
threshold point is reached. After that point, the output level no longer increases linearly,
but increases at a reduced rate that is determined by the ratio setting.
• Threshold: This control determines the level at which the compressor begins to act on
the incoming signal. It is calibrated in decibels, with a range from –-40.0 dBu to 17 dBu.
• Attack: This determines how fast the compressor reacts once the threshold has been
exceeded. It is calibrated in milliseconds, with a range from 1 ms to
90 ms.
• Release: This determines how fast the compressor turns off once the signal falls below
the threshold. It is calibrated in milliseconds, with a range from 10 ms to 2500 ms (2.5
seconds).
* Ratio: This determines the change in output level as a function of the change in input
level, once the threshold has been exceeded. It is calibrated in decibels, with a range
from 1.2:1 (off) to 30:1.

TECNARE DPA 28X OWNER’S MANUAL
GENERAL SETUP
The following controls are available in the general Setup module:
- Presets
- RTC Setup
- Analyzer
- Network
- Pcc LAN Port
- Internet Router IP
PRESETS
By pulling down the Select Preset dropdown list, 10 different preset saved in the unit can
be selected.
Changes made in the PC software are immediately executed in the DPA-28X, and stored
in the selected preset.
A Preset name can also be stored.

TECNARE DPA 28X OWNER’S MANUAL
ANALYZER
This toggles the audio Analyzer window open and closed.
The following information is available in this window:
- Display: Allows the user to show/hide the input and reference signals.
- Parameters:
- Mode: The audio analyzer allows the user to work on four different modes:
oSpectrum Analyzer
oTransfer Function
oPhase Response
oImpulse Response

TECNARE DPA 28X OWNER’S MANUAL
- Average: Eight different time average can be selected: 1, 5, 10, 20, 30, 50,
80 and 120.
- Window: Signal Windowing by None, Hamming, Triangular, Hanning and
Blackman
- Smooth: Is the frequency average. None, 1/3, 1/6, 1/12, 1/24 Octave.
- Input and Output: Allows the user to choose the PC input and output device.
- Pink noise: Enable the pink noise generator. Note that the Pink noise can only
be enabled when the analyzer is turned Off.
- Buttons:
oOn: Turn on and off the analyzer
oClose: Close the analyzer window
oFade: It makes the window analyzer 50% transparent, so the user can see
the window behind.

TECNARE DPA 28X OWNER’S MANUAL
SPECTRUM ANALYZER
This feature allows the user to visualize the spectral components either of the input signal
(given by a microphone connected to the PC) or the reference signal (output) it is also
possible to visualize both signal simultaneously.
TRANSFER FUNCTION
It shows the systems transfer function, meaning the difference between the signal from
the output of the DPA-28X to the microphone input signal.

TECNARE DPA 28X OWNER’S MANUAL
PHASE RESPONSE
It allows the user to analyze the phase response of an installation
IMPULSE RESPONSE
This tool provide the spectrum impulse response of a certain room.

TECNARE DPA 28X OWNER’S MANUAL
NETWORK
This button toggles the network window open and closed. (Refer to 2.3 for more
information)
PCC LAN PORT AND INTERNET ROUTER ID
When the unit is connected to Ethernet cable, the user is able to control all the unit
parameters from another location remotely.
For this purpose, the remote user must input the PCC Lan Port and Internet Router ID of
the local DPA 28X unit.
GRAPHIC EQUALIZER
Click the ON button to turn the Graphic EQ on and off
Click and drag on the slider fader to adjust the equalization from -15dB to +15dB.
2.5 OUTPUT SECTION
The user can manage the output section by clicking on Out A-B and Out C-D buttons.
Table of contents