3. SAFETY MEASURES
3.1
In case of improper use of the boiler or its misuse, there may be a danger to the health and life of the user or third
parties, as well as the risk of damage to the product and other material values..
3.2
Do not start the boiler without reading this manual in detail. Follow only the operations specified in the Operation
Manual..
3.3
The method of application of the boiler is defined in this Manual.
3.4
Installation, installation in accordance with the technical design, connection, commissioning and maintenance of the
boiler are carried out only by qualified specialists of the authorized service organization that has a permit (license) for this
activity and a certificate from TEKNIX.
3.5
During installation, operation and maintenance of the boiler, the requirements and safety measures specified in this
Manual must be observed.
3.6
The use of a circuit breaker to connect the boiler to the mains is mandatory. Consumption current and recommended
rated circuit breaker current are shown in Table 1.
3.7
IT IS PROHIBITED:
►block, interfere with the operation of protective devices and safety devices;
►violate the integrity of the body and components of the product;
►use elements, devices, devices not provided by the design;
►operate the boiler in case of non-compliance of the parameters of the electrical network set by the manufacturer, the
pressure of the coolant in the system;
►operate the boiler with the front panel removed;
►operate the boiler without grounding;
►use the boiler for other purposes;
►make changes to the design of the product;
►use the boiler in explosive and flammable areas;
►connect the boiler to the mains in case of freezing of the coolant in the heating system;
►switch on the boiler, which is not filled with water, with the shut-off valves of the shut-off valve connected to the heating
system closed;
►use the boiler as a flow heater;
►store flammable and explosive materials and products near the boiler (at a distance of less than 1 m) and on the boiler
body.
3.8
Visual inspection of the integrity of the insulation and protective earthing must be carried out before each switching on of
the boiler.
3.9
It is recommended not to turn off the power supply for protective functions and safety devices.
3.10
Before removing the boiler cover, be sure to turn off the power (turn off the external circuit breaker).
3.11
All inspection and maintenance work must be carried out only after the boiler power supply circuits have been
disconnected.
3.12
The boiler must always operate at the operating pressure, the range of which is set by the technical characteristics
(see Table 1).
3.13
The surface of the boiler can be cleaned only with non-flammable non-aggressive household appliances.
3.14
In case of emergency power failure, the boiler is switched off. After the power supply is restored, the boiler
automatically switches on and restores the last stored mode.
3.15
The manufacturer is not liable for any damage caused by improper or careless operation of the boiler.
4.
TECHNICAL CHARACTERISTICS AND DESCRIPTION
4.1
Technical characteristics of boilers are shown in Table 1.
4.2
The boiler operates reliably throughout its service life in compliance with the operating conditions set out in this
Manual and timely maintenance.
4.3
The boiler device is shown in Figures 1, 2.
4.4
The coolant is heated in the heat exchanger flask. The number of heating elements and their power depends
on the boiler model (see Table 1). To extend the service life of heating elements, alternating switching on of heating
elements (rotation of heating elements) is provided.
4.5
Operation of the boiler is provided by the control unit.
The control unit controls the following parameters:
►value of coolant temperature at the boiler outlet;
►the value of the air temperature in the room where the temperature sensor is installed (supplied);
►temperature values in the DHW indirect heating boiler (if connected);