3. SAFETY MEASURES
3.1 In case of improper use of the boiler or its misuse, there may be a danger to the health and life of the user or third
parties, as well as the risk of damage to the product and other material values..
3.2 Do not start the boiler without reading this manual in detail. Follow only the operations specified in the Operation
Manual.
3.3 The method of application of the boiler is defined in this Manual.
3.4 Installation, installation in accordance with the technical design, connection, boiler is carried out only by qualified
specialists of a service organization that has a permit (license) for this type of activity.
3.5 Commissioning of the boiler and maintenance of the boiler is carried out only by qualified specialists of an authorized
service organization that has a permit (license) for this type of activity and a corresponding certificate from TEKNIX.
3.6 The use of a circuit breaker to connect the boiler to the mains is mandatory. Consumption current and recommended
rated circuit breaker current are shown in Table 1.
►block, interfere with the operation of protective devices and safety devices;
►violate the integrity of the body and components of the product;
►use elements, devices, devices not provided by the design;
►operate the boiler in case of non-compliance of the parameters of the electrical network set by the manufacturer,
the pressure of the coolant in the system;
►operate the boiler with the front panel removed;
►operate the boiler without grounding;
►use the boiler for other purposes;
►make changes to the design of the product;
►use the boiler in explosive and flammable areas;
►connect the boiler to the mains in case of freezing of the coolant in the heating system;
►switch on the boiler, which is not filled with water, with the shut-off valves of the shut-off valve connected to the
heating system closed;
►use the boiler as a flow heater;
►store flammable and explosive materials and products near the boiler (at a distance of less than 1 m) and on the
boiler body.
3.8 Visual inspection of the integrity of the insulation and protective earthing must be carried out before each switching
on of the boiler.
3.9 It is recommended not to turn off the power supply for protective functions and safety devices.
3.10 Before removing the boiler cover, be sure to turn off the power (turn off the external circuit breaker).
3.11 All inspection and maintenance work must be carried out only after the boiler power supply circuits have been
disconnected.
3.12 The boiler must always operate at the operating pressure, the range of which is set by the technical characteristics
(see Table 1).
3.13 The surface of the boiler can be cleaned only with non-flammable non-aggressive household appliances.
3.14 In case of emergency power failure, the boiler is switched off. After the power supply is restored, the boiler
automatically switches on and restores the last stored mode.
3.15 The manufacturer is not liable for any damage caused by improper or careless operation of the boiler.
4. TECHNICAL CHARACTERISTICS AND DESCRIPTION
4.1 Technical characteristics of boilers are shown in Table 1.
4.2 The boiler operates reliably throughout its service life in compliance with the operating conditions set out in this Manual
and timely maintenance.
4.3 The boiler device is shown in Figures 1, 2.
4.4 The coolant is heated in the heat exchanger flask. The number of heating elements and their power depends on the
boiler model (see Table 1). To extend the service life of heating elements, alternating switching on of heating elements
(rotation of heating elements) is provided.
4.5 Operation of the boiler is provided by the control unit.
The control unit controls the following parameters:
► value of coolant temperature at the boiler outlet;
the value of the air temperature in the room where the temperature sensor is installed (supplied);
temperature values in the DHW indirect heating boiler (if connected);
► condition of the room thermostat (if connected, the thermostat is not included). The boiler maintains the air
temperature in the room according to the value set by the room thermostat;
► coolant flow in the boiler;
► input status of the "Priority Consumer" function;
► the amount of leakage current;
► the magnitude of the input voltage.
Also manages the work:
► circulating pump;
► heating elements;
► DHW three-way valve (not included).
4.6 A manometer is installed in the boiler to visually monitor the working pressure. The operating pressure range of 0.4 ...
1.5 bar is highlighted in blue on the manometer.
4.7 For safe and reliable operation, the boiler is equipped with protective mechanisms and safety devices that provide:
►Boiler protection against overpressure - the boiler has a safety valve to protect against overpressure. If the pressure
value exceeds 3 bar, the coolant is automatically discharged.
►Overheat protection - in case of coolant overheating in the heat exchanger bulb, the emergency thermostat
switches off the boiler power supply and, accordingly, the heating elements, regardless of the presence of a switching
signal from the control unit.
►- the boiler is equipped with a flow sensor. If the flow
of water through the boiler is reduced to less than 3.7 l / min, the heating is automatically switched off and an error
code appears on the boiler display.
►Protection against high voltage;
►Leakage current protection.
DHW MODE
6.3.21 To activate/deactivate the DHW mode (indirect heating boiler heating), briefly press the button____after
activating the control panel. When the DHW mode is on, the button____is 100% illuminated.
6.3.22 In the DHW mode it is provided:
► the setting of the water heating temperature in the indirect heating boiler is displayed by the indicator____ ;
► The on / off function of the "Anti-Legionella" function is indicated by the indicator____ .
6.3.23 By default, the value of the coolant temperature at the boiler outlet for heating the DHW circuit is set +80°C. The
boiler control unit controls the heating temperature in the DHW tank. When the DHW circuit heating is switched on, the
indicator____lights up on the display. When the set water temperature in the DHW tank is reached, the heating is
switched off. When operating in combined mode, the three-way valve is automatically switched to heat the heating
system.
WARNING!
The maximum value of water temperature in the boiler of indirect heating +60°C
(limited to the service menu).
6.3.24 For optimal heating of water in the DHW circuit it is necessary that the temperature of the coolant at the boiler
outlet was 20 - 25°C above the set value of water temperature in the boiler (see section "Service menu" Table 3
Parameters ., ., .).
6.3.25 When activating the "Anti-Legionella" function (indicator____), the boiler heats the water in the boiler of
indirect DHW heating to a temperature of + 70 ° C and maintains it for 10 minutes. After that, the boiler returns to
operating mode. The indicator____goes out when the "Anti-Legionella" function expires.
WARNING!
The "Anti-Legionella" function is available after switching on the boiler regardless of the
selected operating mode. When activating the "Anti-Legionella" function, the value of the
operating settings of the boiler in DHW mode.
WARNING!
It is forbidden to use the indirect heating boiler when activating the "Anti-Legionella"
function! Risk of thermal burns due to high temperature of water heating in the boiler of
6.3.26 You can activate the "Anti-Legionella" function (indicator____) in the "DHW settings" menu. To enter the DHW
settings menu, press and hold the button____for 5 seconds, after which the button____starts flashing.
Buttons________used to select the parameter (the indicator____should light up, the display shows the current status of
the parameter). To turn on the "Anti-Legionella" function, press the button____after which the
indicator____starts flashing. Use the buttons________to select the status of the "On" parameter.
To forcibly disable the "Anti-Legionella" function in the "DHW settings" menu with the buttons________, you can
select the status of the parameter.
6.3.27 Changing and adjusting the DHW mode parameters is performed in the "DHW settings" menu. To enter the
DHW settings menu, press____and hold for 5 seconds. In the "DHW settings" menu, the button____flashes when the
mode settings are changed.
6.3.28 When entering the DHW settings menu, the display will show the last parameter edited.
6.3.29 In the "DHW settings" menu, the setting parameter is selected by pressing the buttons________. The selected
parameter is illuminated by the corresponding indicator.
6.3.30 You can complete the configuration in one of the following ways:
- inactivity for 10 seconds, after which the new values are saved;
- by pressing the button____for one second.
6.3.31 You can change the value of the parameter "Water heating temperature in the indirect heating boiler"
(indicator____) in the menu "DHW settings". To enter the DHW settings menu, press and hold the button____for 5
seconds, after which the button____starts flashing. Buttons________are used to select the parameter (the
indicator____lights up, the display shows the current value of the water temperature in the indirect heating boiler). To
change the value of the water temperature in the tank, press the button____, after which the indicator____starts
flashing. Buttons________are used to set the desired value of the water temperature in the tank in the range from +30
to +60°C.
6.2.5 When the boiler is in standby mode (power supply is supplied, external circuit breaker is switched on), all protective
functions of the boiler are active, including the "Antifreeze" function. The indicator button on the display lights up in
red____.
WARNING!
"Antifreeze", are not active. Therefore, it is important to consider the ambient temperature.
coolant from the boiler, heating system and hot water supply circuit.
6.3 SELECTING AND SETTING THE OPERATING MODE
6.3.1 After switching on from the control panel, the following boiler operating modes are available:
►heating mode;
►DHW mode;
►combined mode (boiler works for DHW and HS heating).
WARNING!
Water heating in the DHW indirect heating boiler is a priority mode of boiler operation. When
heating the water in the DHW boiler, the heating system does not heat up!
6.3.2 The algorithm of the "Antifreeze" function is implemented as follows. The boiler controls the temperature of the
coolant at the boiler outlet. When the temperature drops to +5°C, the circulation pump starts automatically, the
three-way valve is moved to the "Heating system" position, and the heating of the heating system is switched on. The
message "AFr" appears on the display. Heating continues until the temperature of the coolant at the outlet of the boiler
+ 30°C. After that, the heating is switched off and the message "AFr" disappears on the display.
WARNING!
When the "Antifreeze" function is activated, the DHW circuit heating stops automatically. At
the end of the "Antifreeze" cycle, the boiler returns to its original mode.
6.3.3 The "Pump and three-way valve protection" function is activated if the pump and three-way valve have not been
operated for 24 hours. The pump will switch on for 1 minute and the three-way valve will switch and return to its original
position. When the function is activated, the message "PPr" (Pump Protection) appears on the display.
In case of prolonged disconnection of the boiler from the mains, it is recommended to periodically start the boiler at
least once a month at regular intervals.
6.3.4 Operation of the circulation pump in any operating mode of the boiler is indicated____by an indicator on the control
panel.
6.3.5 Implementation of the "Child lock" function involves locking the control panel. The control panel buttons are
automatically locked when switched off for 20 seconds or when the button is pressed briefly (1 second)____.
6.3.6 Control of operating modes and parameter settings are available from the control panel, the appearance of which
is presented in Figure 3, as well as through the appendix (the operation of the program is described in Appendix 1 to this
manual).
6.3.7 To unlock the control panel, press and hold the button for 5 second____.
HEATING MODE
6.3.8 ____.
When switching to heating mode, the button____is illuminated 100%.
6.3.9 In the heating mode the following parameters can be set:
► the temperature of the coolant at the boiler outlet is displayed by an indicator____;
► room air temperature (temperature sensor supplied with the boiler) is indicated by an indicator____;
► the value of the difference between the on and off temperatures of the boiler;
► Input value (contact status) "Thermostat".
6.3.10 With the active parameter "Coolant outlet temperature" (indicator____), the boiler maintains the coolant outlet
temperature set for the heating mode. Automatic switching on of the boiler heating elements occurs when the coolant
temperature decreases (by default - by 5 ° С from the set temperature parameter____). When the heating is switched on,
the indicator____lights up on the display. The heating will be switched off when the coolant temperature reaches the
set value.
6.3.11 When the "Indoor air temperature" parameter (indicator____) is active, the boiler maintains the set room air
temperature in which the supplied temperature sensor is installed. Automatic activation of the boiler heating elements
occurs when the room temperature decreases by 0.5 ° C (when the heating is switched on, the indicator____lights up on