Tema Telecomunicazioni AD639R User manual

AD639R
VoIP SIP PoE Call Repeater
Audio Over IP SIP Network
PRODUCT MANUAL
Version HW 1.0 - Version SW 1.10
Revision
Date
Revision reason
Prepared
Checked/Approved
0 22/01/2019 First release MM, DP DP, FL
TEMA TELECOMUNICAZIONI
“IP COMMUNICATION AND SECURITY COMPANY”
WWW.TEMATLC.IT
Products for VoIP SIP LAN networking Communications, Paging Amplifiers Systems and
Audio Applications. Zone Announcements, Night Ringer, Multicast general call,
Background music, Standard SIP call or Emergency call, SD memory with pre-recorded
me
ssages, Relays for LAN drives.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 2 of 30
We, TEMA TELECOMUNICAZIONI SRL Via C. Girardengo, 1/4 - 20161 MILANO
declare under our sole responsibility that the product:
Product name Altoparlante VoIP SIP PoE ripetitore di chiamata
Trade name TEMA TELECOMUNICAZIONI Srl
Type or model AD639R
and accessories --
to which this declaration relates is in conformity with the essential requirements and other
relevant requirements of the R&TTE Directive ( 1999/5/EC, 2006/95/EC, 2004/108/EC ).
The product is in conformity with the followings standards and/or other normative documents:
HEALT & SAFETY EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011
EMC EN 55022:2010, EN 55024:2010, EN 61000-3-2:2006
EN 61000-3-3 :2008
MILANO, 20 April 2019 TEMA TELECOMUNICAZIONI SRL
D. Pontillo
I.
IMPORTANT INFORMATIONS REGARDING THE RECOVERY AND RECYCLING OF THIS
ELECTRONIC DEVICE
DICHIARAZIONE DI CONFORMITÀ CE
DECLARATION OF CONFORMITY CE
The crossed
-
out wheeled bin symbol below indicates t
hat this electronic equipment is
intended to be disposed in a separate collection and not in an unsorted municipal
waste, in order to provide for the treatment of WEEE (Waste Electrical and Electronic
Equipment) using best available recovery and recycling techniques. Specific treatment
for WEEE is indispensable in order to avoid the dispersion of pollutants and other
hazardous substances into the waste stream, while recycling leads to reduction of
disposal of waste and the negative impacts on environment and human health. That is,
priority is given to reuse of WEEE in its components, subassemblies and
consumables. As the final holder, the user has an important role in contributing to
reuse, recycling and other forms of recovery of WEEE and is responsible to return this
waste in the collection facilities set up by EC Member States and to fulfill other duties
in compliance with Directive 2002/96/EC and local laws.
UNI EN ISO 9001:20
15
TEMA TELECOMUNICAZIONI is a certified company

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 3 of 30
RECOMMENDATIONS
1. It is recommended to read this entire manual before proceeding to the installation of the device.
2. The installation and commissioning of the device can only be performed by specialized technicians.
3. The device is accurately manufactured and tested. In any case, the product is not recommended for use
where an error of operations can cause property damage and/or injury to persons.
4. It is expressly not recommended maintenance inside the device which must be carried out by Tema
Telecomunicazioni, the removal of the closures will invalidate the warranty and makes accessible internal
parts with risk of electric shock.
5. Tema Telecomunicazioni accepts no responsibility for damage to property and/or persons resulting from
incorrect use of the equipment or by procedures that do not comply with the instructions in this manual.
Tema Telecomunicazioni reserves the right to make modification to the technical and functional
specifications at any time and without any notice.
6. Products powered via PoE (Power over Ethernet) may only be connected with cables coming from the
internal network company (inside the building), are not allowed connections LAN cables coming from outside
the building.
7. Use for this device only and exclusively original spare parts and consumables supplied by Tema
Telecomunicazioni. The company is not responsible for damage caused by the use of materials not supplied
by the same.
8. Do not expose the unit to direct sunlight, protect from heat, dust, humidity and chemicals.
9. Tema Telecomunicazioni reserves the right to vary the product characteristics for improvement without prior
notice. Check the WWW.TEMATLC.IT website for any updates to the latest firmware, manuals, and
technical documentation.
10. This document is property of Tema Telecomunicazioni, It is forbidden any duplication and reproduction, even
partial, as well as storage on any medium without written permission of Tema Telecomunicazioni.
This symbol in the descriptions indicates a general warning or a damage danger
to equipment or people.
This symbol in the descriptions indicates useful information or a suggestion for
the optimization of the device functionality.
This symbol in the descriptions indicates
an hazar
d warning for electric shock
to equipment or
people.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 4 of 30
1. PRESENTATION ........................................................................................................................................ 5
2. AVAILABLE MODELS AND ACCESSORIES......................................................................................... 6
3. FEATURES AND PERFORMANCE ......................................................................................................... 7
4. PACKING LIST ........................................................................................................................................... 7
5. 4. TECHNICAL SPECIFICATIONS........................................................................................................... 8
6. OPERATION................................................................................................................................................ 9
6.1.
D
EVICE CONNECTION DIAGRAMS
..........................................................................................................................9
7. OPERATING MODES............................................................................................................................... 10
7.1.
C
ALLS TO DEVICES
...........................................................................................................................................10
7.2.
RELAY
FUNCTION
...........................................................................................................................................10
7.3.
C
ALLS GENERATED FOR THE ACQUISITION OF EXTERNAL CONTACTS FOR SPECIAL SIGNALINGS
.................................10
8. INSTALLATION OF THE DEVICE .......................................................................................................... 11
8.1.
C
ONNECTING THE
AD639R
INTERNAL MODULE
...................................................................................................11
9. PROGRAMMING ...................................................................................................................................... 13
9.1.
P
REPARATION FOR THE SYSTEM PARAMETERS PROGRAMMING
..............................................................................13
9.2.
A
CCESS TO PROGRAMMING
...............................................................................................................................15
9.3.
N
ETWORK PARAMETERS
...................................................................................................................................16
9.4.
SIP
PARAMETERS
............................................................................................................................................17
9.5.
A
LARM INPUT SETTINGS
....................................................................................................................................18
9.6.
M
ESSAGES MANAGEMENT
.................................................................................................................................19
9.7.
A
UTOMATIC ANNOUNCEMENTS
..........................................................................................................................20
10. MAINTENANCE........................................................................................................................................ 22
10.1.
S
YSTEM
....................................................................................................................................................22
10.2.
L
OGIN CREDENTIALS
...................................................................................................................................23
10.3.
D
IAGNOSTIC LOGS
......................................................................................................................................23
10.4.
M
ULTICAST
A
UDIO
S
TREAMING FOR ANNOUNCEMENTS
...................................................................................24
11. APPENDIXES............................................................................................................................................ 25
11.1.
FAQ
F
REQUENTLY
A
SKED
Q
UESTIONS
.........................................................................................................25
11.2.
A
PPENDIX
3:
U
SE OF THE
AUDACITY
SOFTWARE FOR AUDIO FILES RECORDING
...............................................28
11.3.
A
PPENDIX
4:
C
ABLING OF A
UTP
RJ45
NETWORK CABLE ACCORDING TO THE STANDARD
EIA568B.....................29
INDEX
PAGE

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 5 of 30
1. PRESENTATION
AD639R is a IP SIP telephone call repeater which is registered on the VoIP PBX with its own telephone number
and inserted in the night ringtone group or in any group where you want to repeat the phone call routed on that
group. When an incoming call arrives, the system reproduces a warning sound from the powerful internal speaker.
The system already has several call tones in memory that can be selected during the configuration, some of which
show an increase in volume over time: they start with a low volume that increases progressively in case of no
response. The default tone can be replaced by another by choosing from those supplied, or it can be freely
registered by the user and loaded into the system via web browser with simple operations. The volume can be
adjusted as desired.
AD639R can be powered directly on the same LAN cable if it comes from a PoE switch, or from a PoE injector or
230Vac external power supply, both in the Tema catalog. Power supplies from PoE switches and external power
supply can coexist. AD639R incorporates an efficient 40W amplifier (with external power supply, 10W in PoE), in D-
class.
The programming of the systems takes place remotely via LAN with few operations and in a few minutes:
1) Connect AD639R in a LAN socket to a PoE switch with standard cat. 5/6 cable, or to a generic switch by
powering it with an external power supply.
2) Connect with a browser and assign an IP address and the credentials of the LAN network.
3) Register into IP-PBX the number assigned to AD639R in the space reserved for SIP account.
4) Enter the number assigned to AD639R in the night group of the PBX, or divert incoming calls (in the absence of
the PO) to the number assigned to AD639R.
Some models of AD639R can be supplied with a LED or FLASH Xenon optical indicator in different colors, to add a
light signal to the acoustic signal. The luminous indicators are also available separately and can also be mounted
later on outside the device, with the power supply available from the device itself and controlled by one of the 2
internal relays integrated in the system.
AD639R is also equipped with an External contact input with multiple functions, for example: it provides for
making a SIP call to a programmed IP address (peer2peer call) and informing the operator of the event with a
specific voice message. The signal can be repeated a programmable number of times, the operator can interrupt
the sequence with a code from the keyboard. Other examples of use will follow in this manual.
Multicast Audio Streaming for music and announcements broadcast. AD639 handles 1 multicast channel in LAN
for background music and announcements broadcasting. The generation of musical programs in streaming audio
can be managed from a PC of the LAN/WAN network with the Tema “ADAM” management software or with the
dedicated Tema Encoder AD615/S.
Total remote management via LAN, integrated Web Server. Programming, configuration, loading and listening to
audio files, firmware release update, audio volume adjustment, backup and restore the configuration, device
reboot.
AD639R is part of the series of Audio over IP Tema “SipComStage” products tested and compatible with the most
popular brands of PBX and Asterisk-based systems.
Other IP SIP Speakers from the
“
SipComStage
”
series
Tested with most pop lar PBX brands:
SIEMENS - AVAYA - ALCATEL – PANASONIC – SAMSUNG - NEC - CX
LG - WILDIX - AASTRA - ASCOM - NITSUKO - SELTA – PHILIPS
MITEL – ASTERISK BASED SYSTEMS

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 6 of 30
2. AVAILABLE MODELS AND ACCESSORIES
A
A
-
9P4
PoE injector 230Vac/
48Vdc 0,5A.
A
D6 9R
Without
flashing light
AD6 9R/LA
With orange ED
flashing light
AD6 9R/FT
With transparent Xenon
F ASH flashing light
AD6 9R/FR
With red Xenon F ASH
flashing light
Optional accessories
AA
-
9E
DIN Power Supply
220Vac/
24Vdc-1,5A
AD699/X10B
F ASH transparent
Xenon flashing light,
for external connection
AD699
/L10A
Flashing orange
ED, for external
connection
AD699/X20R
Flashing red Xenon
F ASH, for external
connection
AD699/RT
Adjustable support in
horizontal and vertical,
grey color,
5 kg capacity

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 7 of 30
3.
FEATURES AND PERFORMANCE
•
40W (10W PoE) IP wall speaker for indoor or outdoor installation with IP56 protection
•
40W power audio output
•
1 RX Multicast channel for Music/Announcements broadcast
•
2 remote-controlled relays via LAN network or following the incoming telephone call
•
1 multi-function external contact input
•
Possibility of broadcast a pre-recorded announcement, associated with the available input
•
Alert service with dedicated messages following an external event
•
Independent adjustment of audio volumes: multicast, ringtone
•
SD card memory with standard and customizable audio files
•
Great versatility combined with ease of use and programming
•
P2P SIP Peer to Peer mode for alarm reporting
•
Power supply via PoE (Power over Ethernet) 802.af with a single UTP cable for the connection or from an
external power supply, even simultaneously
•
Programming via integrated Web Server interface and password protection
•
Possibility of software/firmware update via LAN
•
Integration with local LAN, Ethernet LAN 100 BaseT port with RJ45 connector
•
1 MULTICAST RX channel for high quality RTP streaming audio for announcements/music
•
Possibility of issuing pre-recorded announcements at set times (up to 5 for each day of the week)
•
Possibility of issuing a daily pre-recorded announcement, at a set time or manually
4. PACKING LIST
The systems are supplied with the parts included in the following list:
•
One AD639R device
•
A printed system documentation, installation, programming, use manual
•
A CD-ROM with complete documentation

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 8 of 30
5. 4.TECHNICAL SPECIFICATIONS
LAN
TCP/IP Network 10/100BaseTx
Protocols
SIP 2.0, RFC 3261
RTP Multicast audio Streaming
G711µ, G711a, G722, L16 from 16 to 44 kHz
Connection
SIP Server (IP
-
PBX) o
r
P2P (Peer To Peer)
Power
Supply
PoE, PoE Injector and/or
external
Ac/Dc
power supply
PoE
IEEE802.3af class
0 12,95W
External Power Supply
(Op
t
.)
230Vac / 12Vdc
-
1A, 24Vdc
-
2A
Technology
I
MX25 400MHz
Micropro
cessor
Memory
256MB Ram, Micro
-
SD Flash 2GB
Programming
practical Web interface and password
Messagges/S
o
unds
prerecorded in the internal SD memory card
Audio File Format
Windows .wav
–
8K
–
16 bit
Duration
6
0
sec each
. Standard (Opti
on up to 960 min.
16H audio)
B
andwidth
350Hz
–
6KHz
Power
D
-
Class
Amplifier
40W
on
4 Ohm
Acoustic pressure
100dB A (SPL)
Dispersion angle
110° @ 2KHz
A
udio
c
om
m
unica
t
ion
Unidirectional
Inputs from buttons or external contacts
1 fo
r
alter
/al
arm
Integ
rated relais
2
Relay
s load capacity
Max 30Vdc
–
1,5
A
Signalings
Active Call
Led
Installation
Wall mount
,
adjustable with optional
accessor
y
Container material
Halogen free EN60754
-
2
Technopolymer
Storage temperature
From
-
20°
to
+65°C
Operating tem
perature
From
-
20° to
+55°C
Relative humidity
Up to 90% non
-
condensing
Dimensions
119 x 70 x 59 mm (
H
x
W
x
D
)
Weight
1,8 Kg
W
arrant
y
2
years, possibility of extension (
O
ption)
Compatibility
CE, ROHS
Call in progress
ed indicator
El
ectronic IP
interface module
with audio power
amplifier
Plastic
membrane
speaker
Signals and
relays
connection
External
flasher
connection
External
power supply
connection
AN cable input
UTP cat.5/6 with
PoE

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 9 of 30
6. OPERATION
In Stand-by and correctly configured, the system waits for incoming calls. When a call arrives, the device plays the
programmed ring tone, at the set volume, without ever answering. The purpose is to repeat the warning of an
incoming call (for example when the switchboard is in night mode or to repeat the signal in noisy environments).
On the PBX it is needed to create a call group that also contains the user number used for AD639R. The activation
of the ringer is also associated with the lighting of the front led and the flashing light (if provided).
During the call it is possible to configure the system to operate its own internal relays to which it is possible to
connect an external flashing light that increases its warning effectiveness (AA-699xxx see Tema catalog).
It is also possible to use the device for Multicast streaming sound broadcast. In this case the RTP audio broadcast
on the network is reproduced amplified (to a different volume than that used for the ringer, useful for background
music or warning messages).
Finally, the status change of an incoming alarm is always monitored, to which it is possible to associate a user to
call and a message to be played to the answer of the called.
6.1. Device connection diagrams
•
SIP telephone call repeater with PoE direct power supply
•
SIP telephone call repeater with PoE injector or external 2 0Vac power supply
Note: for
other applications of
AD639R
and
insertion
diagrams
see the FAQ section in
the Appendices at the end of this manual
UTP cat 5/6 cable
PO and internal
network phones
PoE Switch
AD639R
IP-SIP Call
Repeater
IP PBX
SIP
SERVER
1st R
e
lay
2nd R
e
lay
Fre
e for other uses
ED light
indicator
External Power Supply
230Vac/24Vdc/30W
Cod. Tema AA-39E3
UTP cat 5/6 cable
PO and internal
network phones
Generic Switch
IP PBX
SIP
SERVER
1st R
e
lay
2nd R
e
lay
Fre
e for other uses
Xenon Flash ight
230Vac
PoE Injector
AD639R
IP-SIP Call
Repeater

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 10 of 30
7. OPERATING MODES
7.1. Calls to devices
The AD639R device must be registered to a SIP PBX. It is normally inserted in the night ring group but can also be
called directly with its number. In any case, however, it will never reply (the only purpose is the activation of the
ringer). It is not possible to make a SIP call in Peer2Peer, it is not accepted by the system.
Using the ADAM software or a microphone base and the AD615 codec it is possible to broadcast an
announcement in streaming (in unidirectional mode).
7.2. RELAY function
The internal relays can be used to connect any external flashers. In programming it is possible to decide whether
they should be activated during the ringing of the incoming call.
If they are not programmed to be activated during the call, they can also be controlled using the Tema ADAM
software (Audio Domain & Access Management software).
7.3. Calls generated for the acquisition of external contacts for special signalings
These are the calls that the system generates on the line connected to itself to warn after the trigger of the alarm
input contact by the connected equipment (auxiliary devices or a button made available to users in the proximity of
the device), for the details of the operation see paragraph 8.5.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 11 of 30
8. INSTALLATION OF THE DEVICE
8.1. Connecting the AD639R internal module
Once the necessary equipment has been prepared for fixing the AD639R device, it is first necessary to make the
connections for its operation.
Inside AD639R there is an electronic module for managing the communication functions on the VoIP network and
for amplifying the audio signal. The connection of the signal cables from the field must be carried out by qualified
technical personnel, operate verifying that no cable is live, also strictly comply with the indications of the voltage
and current values for the power supplies and other parts of the system.
Follow the instructions given in the block diagram for the correct electrical connection of the system. On the
following page, the detail of each terminal will be shown.
9 8 7 6 5 4 3 2 1
C A
4
3
2
1
+
-
A C
9 8 7 6 5 4 2 1
1
Input from external
power supply
terminals "C" "A"
The polarity is
irrelevant
Note: not necessary if
AD639 is powered in
PoE on the LAN cable
3
SP1+ 9 Speaker
SP1- 8 Speaker
K1.NC 7 (Relay 1)
K1.CC 6
K1.NA 5
K2.CC 4 (Relay 2)
K2.NA 3
GND 2 (Input 1)
ING1 1 (Input 1)
4
Terminal for
external flasher
Speaker pre-wired
internally
2
LAN RJ45 PoE port

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 12 of 30
1
Removable 4-pole terminal block (screw connector connected to the electronic module)
+Vout
Terminal from which it is possible to withdraw power, POSITIVE
- (GND)
Terminal from which it is possible to withdraw power, NEGATIVE
A
Terminal to power the system, polarity irrelevant
C
Terminal to power the system, polarity irrelevant
2
RJ45 LAN port (present on the electronic module)
AD639R requires a LAN cable to connect to the LAN network. If the cable also carries PoE power supply, it will not
be necessary to supply the module with other power sources (for max 10W power). For higher powers it will be
necessary to power AD639R with a 24Vdc 2A or max 18Vac 2.5A power source. See also appendix 4 at the end of
the manual for the correct wiring of the LAN cable to the RJ45 connector.
3
Removable 9-pole terminal block (screw connector connected to the electronic module)
9 SP1+
Output terminal 1st Class-D amplifier, connected to the internal loudspeaker, positive front
8 SP1-
Output terminal 1st Class-D amplifier, connected to the internal loudspeaker, negative front
7 K1.NC
K1 relay terminal – NC normally closed contact
6 K1.CC
K1 relay terminal – CC central contact (maximum contacts load max 30V 1.5A)
5 K1.NA
K1 relay terminal – NO normally open contact
4 K2.CC
K2 relay terminal – CC central contact (maximum contacts load max 30V 1.5A)
3 K2.NA
K2 relay terminal - NO normally open contact
2 GND
Terminal related to the system power supply negative, for the alarm contact
1 ING1
Terminal for detecting the alarm contact
4
Removable 2-pole terminal block (connector connected to the cable leaving the module)
+
Connect here the positive of the flashlight or external device
- (GND)
Connect here the negative of the flashlight or external device
At the "+Vout" output there is a + 12Vdc voltage when the device is powered via PoE, otherwise, at
this output the voltage will be the same as at the terminals A-C. The use of "+Vout" is permitted as
long as it is not exceeded a maximum 200mA current consumption and the load has a protection on
the input current. Improper use of this output will permanently damage the unit.
Devices powered via PoE (Power over Ethernet) may only be connected with cables coming from
inside the building, they are not allowed connections to LAN cables coming from outside the
building.
To terminals
1 (ING1)
and
2 (GND)
must only be connected a relay contact or a button free from any
voltage to prevent permanent damage to the device.
The power supplied by this terminal is protected and limited to 300mA maximum current, do not
connect devices with a higher power consumption as internal protection would be activated.
ATTENTION: the voltage in these terminals is normally 12Vdc when powered by PoE but may be
24Vdc if powered from an external power supply!
Relay K1 is pre
-
wired to supply power to terminal 4 which
supplies an external flashing light, relay
K2 is free for other uses by the user.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 13 of 30
9. PROGRAMMING
9.1. Preparation for the system parameters programming
Programming is done via the WEB interface. To gain access, simply connect an Ethernet cable from a PC or from a
switch to the LAN port of AD639R.
The default IP address of AD639R is "192.168.0.10".
Remember that in order to successfully connect to the web interface of AD639R, it is necessary that, in the IP
addresses configuration of your PC, is present the subnet 192.168.0.x, where "x" is any number between 1 and
254 and different from 10. See below how to configure your PC to reach the correct subnet. The shown procedure
applies to Windows® operating systems.
Open the Windows Control Panel and set the field "View by": "Category" "Large Icons" or "Small Icons".
Choose "Network and Sharing Center" as shown in the first figure, detect your LAN connection, choosing the one
referring to the network card that you are using to connect with AD639R.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 14 of 30
Once the correct connection is identified, click on it and it will appear the window where it is necessary to click on
the "Properties" button. It will then open the window where must be selected "Internet Protocol Version 4
(TCP/IPv4)" and then click the Properties button again. See the following figures:
If the PC is already on subnet 192.168.0.x with a mask 255.255.255.0, ignore the following steps. Otherwise,
proceed as follows. (The address of the PC configuration should not be 192.168.0.10). Remember the current
TCP/IP configuration of your computer for any subsequent restore of the correct parameters. Click "Use the
following IP address" and type in the appropriate field the following IP address: 192.168.0.11 (instead of "11" used
in the example it is possible to enter any number between 1 and 254, but excluding the 10 which is the default
address of the system to be programmed). In the "Subnet Mask" enter the netmask 255.255.255.0. Click OK to
confirm the changes. The PC is now ready to configure the door phone. Remember at the end of programming to
restore the network configuration of the PC to its original state if necessary.
Once the IP address of your PC is successfully configured, it is possible to reach the Web interface to configure
AD639R at the address 192.168.0.10 .

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 15 of 30
9.2. Access to programming
To program the device, it is sufficient to use a standard browser such as Explorer, Firefox, Chrome or others. The
default address of the device is 192.168.0.10 with a mask of 255.255.255.0, and the user/password with which to
connect are master/master. Make sure to have access to this network segment from your computer. Once logged
in, it is possbile to change the administrative password for the maximum safety of your device. Once logged in, it is
possbile to change the administrative password for the maximum safety of your device.
The use is very simple and intuitive, it is always visible on the left the menu for selecting the functions to be
programmed, while on the right is shown the configuration window that is currently active. Any change will be
confirmed by pressing the "Apply" or "Save" buttons. Closing the browser or changing the page without
selecting those buttons will make lost any change
.
Any changes do not require restarting the device (except the change of IP address, and the software update).

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 16 of 30
9.3. Network parameters
On this page it is possible to set the network parameters, such as IP address, netmask, etc.:
The default IP address of the device is 192.168.0.10/24 . Gateway and DNS are only needed if you want the device
to have the ability to access the Internet (for example to get the current date / time, in the example from the site
time.nist.gov).
The changes to the network settings are taken over by the device until the next reboot. Once you have completed
the configuration steps so be sure to reboot the system and if necessary, change the network segment of your
computer so that it can connect to the new address.
•IP address: specify the IP address you want to assign to AD639R.
•Subnet mask: indicate the subnet mask to be assigned to AD639R.
•Default gateway: indicate the gateway that can enable AD639R to access to internet.
•Primary and secondary DNS server: indicate the addresses of two DNS servers you want to use to resolve
IP addresses.
•Time server: indicate the address of the server you want to use for time synchronization device.
•Test address (ping): if inserted, this address is used by the system to verify the correct operation of the
network connection. It is advisable to enter the address of your PBX, checking before if it responds to ping
requests.
•Device description: text that will appear on the Adam software search mask.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 17 of 30
9.4. SIP parameters
Once the network parameters have been set correctly, you must configure the connection with the VoIP SIP PBX:
•SIP server address: specify the IP address of the SIP PBX to which AD639R should connect.
•Port: is the port number of the SIP PBX with which AD639R must operate. Generally it is the 5060, but
some stations use a different port.
•Domain: enter the domain to which register the system.
•Outbound proxy: some PBXs require that the extension number to call is followed by the proxy address. In
most cases this field can be left empty.
•Local SIP port: generally the 5060 port is used, but it is possible to specify a different number (i.e. for
particular routing tables).
•Expiration: indicates how many seconds the device should check the correct registration of the client.
•User/password: credentials for the registration of the extension (which obviously must have been already
created on the PBX).
•Volume: it is possible to set the volume used to reproduce the sound of Night Ringer. It is also the volume
used to reproduce the prerecorded announcements.
•Ampli on: indicates whether to activate the amplifier during the call.
•Relay 1: for the entire duration of the call it is possible to keep the relay1 activated. It can be used for
example to turn on a flash, a lamp, etc.
•Relay 2: for the entire duration of the call it is possible to keep the relay2 activated. It can be used for
example to turn on a flash, a lamp, etc.
•Ringer tone: it is possible to choose up to 10 pre-programmed ring tones in the device, those ending with
"incr" are the versions of the ringtone which increase the volume over time due to an operator's lack of
response. Position 0 (default) contains a standard ringtone (supplied on the CD with filename "Apt
buzzer"). If you want to insert a user-customized ringtone, or another ringtone supplied with the CD other
than the pre-programmed ones, you will have to load it in the "Message Manager" section in the "Night
Ring" position and click on the "Apply" button.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 18 of 30
9.5. Alarm input settings
In this page it is possible to program the behavior of the acquisition input of the external contact:
•Call addr.: IP address of the phone to contact when the alarm condition occurs.
•Retry: number of call attempts (max 999).
•Separation: separation, in seconds, between one call attempt and another (max 999).
•Delay: is the minimum time, in seconds, before the input status change is evaluated. It can be used, for
example, to mask a door indicator left open after the visitor has entered. Assuming that the maximum time
that the pedestrian entrance must remain open is 30 seconds, only at the end of this time a warning
telephone call would be sent to the staff in charge.
•Inversion: normally the contact is open and the alarm occurs when the contact is closed. Activating this flag
it is possible to instruct the device to behave in the opposite way (the contact is normally closed and the
alarm occurs at opening).
•Stop code: code to dial on the called telephone to accept and silence the alarm (max 3 digits).
•Announce: the activation of the input (of the contact connected to him) causes the broadcast of a pre-
recorded message on the local speaker. See message mask for programming voice messages.
The system can generate a VoIP call to alert, after triggering the alarm input contact (from auxiliary devices or from
a button made available in the vicinity) an appointed operator.
A prerecorded message is played back to the called party. It is possible to invert this logic, so the triggering of the
signaling can occur following the opening of the contact connected to the input.
AD639R continuously monitors the status of the contact and in the event of activation it will begin to call the person
who will manage the situation detected on the programmed telephone number and reproduce the message
associated with the event. It is possible to define an acquisition / acknowledgment code for the alarm signal that the
person called must enter to inform the device of the taking of the alarm signal as notified. If the called number
proves to be busy or does not answer or in any other case where AD639R does not receive the acquisition /
acknowledgment code anyway, at the end of each single call attempt it returns in stand-by and it is ready for a new
alarm notification.
When the AD639R receives the acknowledgment code, the alarm condition signaling stops and no further
notification calls will be made. To be able to be triggered again the notification phase of an activation, the condition
that had triggered the previous notification must return to stand-by. To Only following the occurrence of a new
contact activation condition, the notification cycle with notification calls restarts. In practice: if a connected contact
closes and its activation is detected, AD639R starts making alert calls.
In the event that the person called by the system reply and correctly enters the acknowledgment code, the alert
calls will be terminated. To trigger a new cycle, the contact must reopen and close again.

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 19 of 30
9.6. Messages management
In this window it is possible to change/listen to the messages for “Calling”, “Alarms”, “Announcement” and “Ringer”.
Memory contains a default message for each position, the user can change any of them and the messages format
must be WAV PCM 8 kHz, 16 bit, mono.
The "Alarm Notify Msg 1" is reproduced towards the programmed telephone: when the called person answers, the
message is reproduced several times until the acknowledgment code is entered or a timeout expires. "SIP Alert
Call Button" function.
The "Ann. Alarm 1" message is reproduced on the local loudspeaker when the relative option is active in the alarm
programming screen (par. 9.5) and when the corresponding input is activated. The message is broadcasted before
making a call to a telephone.
Finally the "Night Ringer" message is the one reproduced during the general night call (par. 9.4).
Audio Multicast Streaming
By enabling this feature, AD639R will listen to the specified address/port, and can reproduce on its speaker any
received audio streaming. This function has a lower priority than the normal telephone operation of the system
(outgoing or incoming calls will block or prevent the reproduction of the audio stream).
It is possible to program the volume of the Multicast audio, normally it will be low if the system is used to play
background music or higher if it is used for the broadcast of announcements (for example in combination with a
Tema AD696/BM microphone base).

TEMA TELECOMUNICAZIONI
AD639R VoIP SIP PoE Repeater
MAS-AD639R-REV00EN Page 20 of 30
9.7. Automatic announcements
It is possible to schedule announcements at set times on the local speaker.
Daily activation:
it is possible to automate the diffusion of a daily announcement (which will take place at the set time) for each day.
It will be reproduced for the number of repetitions, with separation between a message and the other given by the
number of seconds set. It is also possible to manually activate the message (with the "Activate now" button) or stop
playback (with the "Stop" button). If the manual activation mode is only used, it is not necessary to indicate the start
time.
The message reproduced is the alarm announcement message found in the "Messages management" section.
Periodic activation from table:
if this function is activated it is possible to indicate in the table below, for each day of the week, up to five different
times. In the example shown, message number 1 (or sound) will be broadcasted from Monday to Friday at the
scheduled times.
Only the message number 1 can be programmed in the "msg" field.
Table of contents
Popular VoIP manuals by other brands

Talkswitch
Talkswitch 240 Configuration guide

ZyXEL Communications
ZyXEL Communications EMG5324-D10A quick start guide

Vidicode
Vidicode V-Tap VoIP quick guide

FHF
FHF ExResistTel IP2 operating instructions

ZyXEL Communications
ZyXEL Communications VMG5313-B30A quick start guide

Multilink
Multilink TVS-301 user manual