(Sel) will blink BLUE to signal that the slave device (sensor) has been successfully selected by
the master device, and the LED indicator (Tx) will blink RED, to confirm successful data
transmission via RS485. Visual instructions for executing the “read distance data” command
are illustrated in Figure 5. The status indicator will also show “Request OK (1/1)”.
Figure 5. Read distance data command execution example
2.3.2. Switching between operating modes
Terabee IND-TOF-1 provides users with 6 operating modes (learn more about each mode
functionality in the official user manual). By default the sensor is shipped with operating
mode 1 pre-set. To switch between operating modes, execute the following WRITE
command/s:
Write operating mode:
●Slave ID: 1 to 247
●Type (Function): 03 Input Register
●Register: 14
●Length: 1
●Value: 1 to 6 (1 for mode 1, 2 for mode 2, etc.)
Figure 6 illustrates an example for setting operating mode 2. In this case, input value 2 in
the “Length” field and click “WRITING” to execute the command.
The LED indicators (Tx; Sel) will blink RED and BLUE.