Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37
-
31 34 44, fax: +370 37
-
31 35 55
E-mail: [email protected], http://www.terraelectronics.com
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled or discarded
according to applicable local and national regulations.
Equipment intended for indoor usage only.
Functional grounding. Connect to the main potential equalization.
TERRA conrms, that this product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN60065,
RoHS norm EN50581.
TERRA conrms, that this product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of
technical equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.
TERRA conrms, that this product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.
Product description
Cascadable 8 output single cable multiswitch with 4 independent signal processors is intended for the distribution of
satellite and terrestrial signals for up to 32 satellite tuners or receivers on each outputs pair.
The multiswitch have 4 passive SAT IF and 1 active Terrestrial TV trunk lines and 4 pairs subscribers outputs (8 outputs
total) and 4 x DC power modes for convenient DC powering options (see chapter „Installation instructions”).
The device ensure an independent access for every subscriber to any SAT IF or Terrestrial TV trunk line.
These multiswitches automatically detect SCR/dSCR mode or legacy format from the receiver. The dSCR switches also
feature fully automatic level control, negating the need for any gain or level adjustments in most installations. Built into a
zinc alloy diecast housing for extreme interference immunity. The housing of multiswitches meets more stringent screening
requirements according to EN50083-2, class A.
Control according to EN50494/EN50607 (SCR/dSCR) as well as Legacy (+13 V/+18 V/22 kHz) commands.
Safety instructions
Installation of the multiswitch must be done according IEC60728-11 and national safety standards.
The multiswitch are powered from the stabilized power supply +20 V. This voltage is not dangerous to life.
External power supply must have a short circuit protection.
Any repairs must be made by qualied personnel.
To avoid damaging of the multiswitch do not connect the supply voltage until all cables have been connected correctly.
The device shall be mounted in vertical position with RF input connectors on the top side on a wall or other nonamable surface.
The multiswitch must be xed with steel screws Ø 4-4.5 mm. The screws are not included in a package.
Do not expose multiswitch to moisture or splashing water and make sure no objects lled with liquids, such as vases,
are placed near or on the unit.
Avoid placing the multiswitch next to central heating components or direct sunlight and in areas of high humidity.
No naked ame sources, such as lighted candles, should be placed on multiswitch.
If the multiswitch has been kept in cold conditions for a long time, keep it in warm room no less than 2 hours before powering.
The ventilation should not be impeded by covering the multiswitch with items, such as newspapers, table-cloths, curtains.
The mains socket of external power supply must be easily accessible.
IMPORTANT WARNINGS!
Before connecting any products to a system, it is essential to make sure the system power supply is switched off. Avoid
short-circuit or overload of any power supply. Never “HOT-SWAP” any system components as this may result in damage to
the newly introduced or existing components.
The SRM580 multiswitch is intended only for indoor installation or installation in a suitable weatherproof outdoor cabinet.
This multiswitch must not come into contact with moisture or be installed in areas of high humidity or heat.
Suitable for moderate and tropical climates.
Always mount the multiswitch securely to a wall or bulkhead panel so it cannot hang or swing on its coaxial cables as
this may strain the internal circuit board and components.
Always connect all of the coaxial cables to the multiswitch before connecting the power. These units are not designed to
be “HOT-SWAPPED” or connected to a live system.
Always be sure that connecting cables shield and multiswitch functional grounding clamp have common potential before
powering the system. Floating voltages can be created in an un-earthed system which may cause damage and can be dangerous.
Momentary short-circuit of any cables may be enough to damage the sensitive electronics within the multi-switch or the
connected system.
Always allow plenty of ventilation around the multi-switch and do not allow it to be covered with materials such as loft insulation.
We recommend at least 5 cm of airspace around the multi-switch. Digital products can get hot to the touch and require
a ow of air to avoid overheating.
SRM580 multiswitch is designed only to work with Ku band Quattro LNBs.
LNB’s and other system equipment connected to the multiswitch SAT H,Lo and H,Hi trunks inputs/outputs can be powered
from the same power supply as the multiswitch.
To avoid damage not covered by warranty DO NOT EXCEED MAX CURRENTS. See “Technical
characteristics” for max. current for external equipment.
DO NOT OPERATE THE DC POWER TO H TRUNK LINES SWITCH (see Figure 1, pos.21) unless you
totally understand the power demands of the system and conrmed they are 2 A or less. ALWAYS LEAVE
THE DC POWER TO H TRUNK LINES SWITCH IN THE "OFF" POSITION when inserting SRM580 into an
existing multiswitch installation.
Damage caused by current overload is not covered by the manufacturer’s warranty.
dSCR (Digital satellite cable router) multiswitch SRM580
Vers. 1.04
Recommended accessories
1. Power supply PS202F
2. Power inserter PI012
3. Multiswitch programmer PC102W
Table 3
Output 1 Output 2
8 SCR/dSCR UB + up to 24 dSCR UB + Terrestrial TV Legacy + Terrestrial TV
8 SCR/dSCR UB + up to 24 dSCR UB, PIN protected + Terrestrial TV Legacy + Terrestrial TV
Static mode (up to 32 converted transponders) + Terrestrial TV Legacy + Terrestrial TV
8 SCR/dSCR UB + Static mode (24 converted transponders) + Terrestrial TV Legacy + Terrestrial TV
See programmer user manual for more information.
Technical characteristics
* without external DC feeding
Frequency range SAT IF 950-2150 MHz
Terr. TV 47-862 MHz
Number of inputs SAT IF 4
& trunk outputs Terr. TV 1
Number of tap outputs 8 (4 pairs)
Return loss / impedance > 10 dB / 75 Ω
Input level SAT IF 60-95 dBµV
Terr. TV (active mode) 92 dBµV max.
Terr.TV noise gure (active mode) 6 dB
Tap output user bands (dSCR mode) congurable 32 max.
with combined DTT user band bandwidth congurable 20-60 MHz
(dSCR mode)
dSCR mode output level, 84 dBµV
AGC controlled
legacy mode output level 78 dBµV
Terr. TV loss (active mode) 6 dB
Terr. TV loss (bypass mode) 22 dB
Terr. TV output level 86 dBµV max.
(active mode)
Trunk gain SAT IF > - 4 dB
Terr. TV (active mode) 10 dB
Terr. TV (bypass mode) -6 dB
Terr. TV output level 102 dBµV max.
(active mode)
DC pass through SAT IF 2 A max., 1 A max. through one line
trunk lines Terr. TV 250 mA max.
Decoupling SAT IF inputs/SAT IF inputs > 30 dB
SAT IF inputs/tap outputs > 30 dB
SAT IF/ Terr. TV > 25 dB
Current from DC input* 20 V 1.2 A max.
consumption from H trunk lines 15 V 1.5 A; 18 V 1.25 A; 20 V 1.2 A
Terr.TV amplier 15-20 V 40 mA max.
from STB legacy mode 13 V 260 mA max.; 18 V 230 mA max.
dSCR mode 13 V 360 mA max.; 18 V 290 mA max.
legacy+dSCR mode
Current pass from DC input to H trunk lines, switchable 20 V 800 mA max.
Operating temperature range -20o÷ + 50oC
Dimensions/Weight (packed) 226.6x133.6x30 mm/0.80 kg
Power ON indication LED (see Figure 1, pos. 22) glows green at any of the 4 powering modes.
Then switch on receiver(s). The multiswitch will begin the process of auto-detecting which type(s) of receiver connected.
All subscriber outputs are congured to connect legacy STB (supports +13V / +18V/22 kHz signals), but it switches to
dynamic mode SCR/dSCR if receives a DiSEqC command according EN50494/EN50607. Disconnect RF cables or STB‘s
from necessary outputs to reset to legacy mode.
Terr. TV path has two modes (see “Technical characteristics”):
1. Bypass mode - switch (see Figure 1, pos. 14) position OFF. DOCSIS signals can pass through.
2. Active mode - switch (see Figure 1, pos. 14) position ON.
PIN code
All User Bands (UB) are protected by PIN Code to prevent the set of UB from being used/disturbed by another user (see Table 2).
Default settings
1. SAT IF inputs are congured to use Ku-band Quattro LNB (SAT A, LNB Lo=9750/10600 MHz).
2. All outputs are congured to connect Legacy STB (+13 V/+18 V/22 kHz), but it switches to Dynamic mode SCR/dSCR
if receives a DiSEqC command according EN50494/EN50607 (Active mode). Output User Bands (UB) are the same in all
subscriber outputs (see Table 2).
3. PIN Codes (see Table 2 and see chapter "Conguration").
4. Only one UB plan is set depended of delivery region, if you need another plan (see chapter "Conguration" or contact
TERRA UAB).
5. Terr. TV bypass mode switch (see Figure 1, pos. 19) in position “OFF” (see “Technical characteristics”).
6. DC power to H trunk lines switch (see Figure 1, pos. 21) in position “OFF”.
Table 2
Conguration
The default setting of the device can be changed using dedicated programmer and software.
This multiswitch can be congured up to 32 User Bands (UB) per pair outputs (total 128 UB) for use with STB’s supporting
DiSEqC commands according to standards EN50494/EN50607 (SCR/dSCR) as well as Legacy (+13 V/+18 V/22 kHz)
commands. Default settings Dynamic mode can be changed to Static mode.
PC Windows software can be free downloaded from www.terraelectronics.com.
Output conguration must be the same per pair of outputs, but can be different in others pairs. Each pair of outputs is
congured separately. Pay attention to the numbering of outputs.
Some possible outputs pair congurations shown in Table 3:
1– V, Lo trunk input
2– H, Lo trunk input
3– V, Hi trunk input
4– H, Hi trunk input
5– Terrestrial TV trunk input
6– V, Lo trunk output
7– H, Lo trunk output
8– V, Hi trunk output
9– H, Hi trunk output
10 – Terrestrial TV trunk output
11 – Legacy/dSCR output2 pair D (Legacy/UB+Terr.TV)
12 – Legacy/dSCR output1 pair D (Legacy/UB+Terr.TV)
Figure 1. External view of the multiswitch
External view
Marking: v.0 Marking: v.1 Marking: v.2
User
Band
(UB)
PIN
Code
Bandwidth,
MHz
Central frequency,
MHz
Bandwidth,
MHz
Central frequency,
MHz
Bandwidth,
MHz
Central frequency,
MHz
EN50494 EN50607 EN50494 EN50607 EN50494 EN50607
UB0 46 1210 1210
UB1 1 40 1210 1210 40 1210 no 46 1420 1420
UB2 2 40 1420 1420 40 1420 no 46 1680 1680
UB3 3 40 1680 1680 40 1680 no 46 2040 2040
UB4 4 40 2040 2040 40 2040 no 46 1006 1006
UB5 5 40 1284 1284 40 no 985 46 1057 1057
UB6 6 40 1516 1516 40 no 1050 46 1108 1108
UB7 7 40 1632 1632 40 no 1115 46 1159 1159
UB8 8 40 1748 1748 40 no 1275 46 no 1261
UB9 9 40 no 970 40 no 1340 46 no 1312
UB10 10 40 no 1010 40 no 1485 46 no 1363
UB11 11 40 no 1050 40 no 1550 46 no 1471
UB12 12 40 no 1090 40 no 1615 46 no 1522
UB13 13 40 no 1130 40 no 1745 46 no 1573
UB14 14 40 no 1170 40 no 1810 46 no 1624
UB15 15 40 no 1330 40 no 1875 46 no 1731
UB16 16 40 no 1370 40 no 1940
13 – Legacy/dSCR output2 pair C (Legacy/UB+Terr.TV)
14 – Legacy/dSCR output1 pair C (Legacy/UB+Terr.TV)
15 – Legacy/dSCR output1 pair A (Legacy/UB+Terr.TV)
16 – Legacy/dSCR output2 pair A (Legacy/UB+Terr.TV)
17 – Legacy/dSCR output1 pair B (Legacy/UB+Terr.TV)
18 – Legacy/dSCR output2 pair B (Legacy/UB+Terr.TV)
19 – Terrestrial TV mode switch
20 – DC 20V power input
21 – DC power to H trunk lines switch
22 – Power ON indication LED
23 – Ground clamp
All sockets are “F” type.
H,Lo
H,Lo
H,Hi
H,Hi
V,Lo
DC IN 20V 2A
V,Hi
V,Hi
Terr.TV
Terr.TV
Frequency SAT TV
range Terr. TV
Trunk gain SAT TV
Terr. TV
Current consumption 20V 1.2 Amax
950-2150 MHz
47-862 MHz
-4 dB
10 / -6 dB
dSCR multiswitch SRM580
V,Lo
Terr.TV Amp.
On Off
1 2 3 4 51 2 3 4 5
6 7 8 9 1020
11
12
13
14
15
16
17
18
19
22
1
2
1
2
Pair D
Pair C
2
1
2
1
Pair A
Pair B
On
Off
23
21
DC to H lines
Legacy / dSCR
+Terr.TV
DC IN
Legacy / dSCR
+Terr.TV
DC IN
Power ON
Installation instructions
Read the safety instruction rst.
Fit multiswich on mounting place and connect it (pay attention to the multiswitch inputs and Quattro LNB outputs marking, connect
the isolated 75Ω loads to the unused RF output F sockets), power on multiswich using one of 4 powering modes (see Table 1).
Table 1
Powering mode
”DC power
to H trunk lines
switch” position
(see Figure 1, pos.21)
Warnings and notes
1. Multiswich powered from local PSU (20V) via
DC input
(see Figure 1, pos. 20) . (Recommended for use is
PS202F 20 V PSU).
H trunk lines are DC isolated from it.
OFF
Recommended as rst choice.
WARNING: BEFORE CONNECTION
ALWAYS CHECK DC POWER TO H TRUNK
LINES SWITCH (see Figure 1, pos.21). IT
MUST BE IN POSITION "OFF"!
Note: All trunk lines preserve DC bypassing.
2.Multiswich is powered from local PSU (20 V)
via DC input and with DC passing to H trunk
lines.
In this mode H trunk lines can power in cascade
other multi-swiches (without PSU, with “DC to H
trunk lines” switch ON)
ON
WARNING: Don’t overload PSU via H trunk
lines – check total system power consumption
of multiswich and from H trunk lines (including
all other equipment connected).
Check all other system equipment connected
to H lines if it can accept 20 V. SERIOUS
DAMAGE OF IT CAN OCCUR!
3. Multiswich is powered from H trunk
lines:
- build new SCR/dSCR system (18 V - 20 V)
- upgrading old legacy systems (15 V - 18 V)
ON
WARNING: Don’t exceed the current capability of system
power supply.
SERIOUS DAMAGE CAN OCCUR IF OVERLOADED!
4. Multiswich is powered from Legacy/
dSCR (subscriber) outputs
(see Figure 1, pos. 11-18).
Each dSCR output circuit is individualy
powered directly from STB’s or from dSCR
power inserter (with 22 kHz bypass). OFF
WARNING: MULTISWITCH WILL DRAW CURRENT AND
POWER FROM PAIR OUTPUT WITH HIGEST
VOLTAGE! If STB’s connected to Legacy/dSCR outputs
can’t supply sufcient power for it’s own output – dSCR
power inserter with 20 V PSU should be used (one per
output of pair A, B, C or D).
Note: Terr. TV amplier can be powered from H trunk lines
(15-20 V) to minimize current consumption from STB and
keep Terr. TV operation when all STB‘s are OFF.

Popular Network Router manuals by other brands

Hirschmann RS20 series user manual

Hirschmann

Hirschmann RS20 series user manual

Synology RT2600ac user manual

Synology

Synology RT2600ac user manual

Linksys E56000 user guide

Linksys

Linksys E56000 user guide

Zte WF820+ user manual

Zte

Zte WF820+ user manual

Digisol DG-GS4528S user manual

Digisol

Digisol DG-GS4528S user manual

ZyXEL Communications IES-5106M user guide

ZyXEL Communications

ZyXEL Communications IES-5106M user guide

Huawei B2368 quick start guide

Huawei

Huawei B2368 quick start guide

elmeg T240 operating instructions

elmeg

elmeg T240 operating instructions

Asus ZenWiFi Pro ET12 quick start guide

Asus

Asus ZenWiFi Pro ET12 quick start guide

Wieland wienet UMS 20-16G-4SFP-W installation instructions

Wieland

Wieland wienet UMS 20-16G-4SFP-W installation instructions

PROLiNK Hurricane 9200P Quick installation guide

PROLiNK

PROLiNK Hurricane 9200P Quick installation guide

D-Link DVG-7044S Quick installation guide

D-Link

D-Link DVG-7044S Quick installation guide

Draytek Vigor2110 Series user guide

Draytek

Draytek Vigor2110 Series user guide

Planex BLW-04GZ-PK Getting started guide

Planex

Planex BLW-04GZ-PK Getting started guide

Advantech IMC-150LI Startup manual

Advantech

Advantech IMC-150LI Startup manual

SMC Networks SMC8612T2 installation guide

SMC Networks

SMC Networks SMC8612T2 installation guide

muLOGIC RSA-1 20 Series manual

muLOGIC

muLOGIC RSA-1 20 Series manual

Siemens SCALANCE M812 operating instructions

Siemens

Siemens SCALANCE M812 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.