Thane Fitness Magnassager User manual


Owner’s Manual
(2)
Before You Begin
The application of the Magnassager is unlike any massage device on the market.
Most users have come to expect massage devices to vibrate or pulverize the
muscle into submission. The Magnassager does not vibrate; it is intended
to soothe and gently knead the muscle. Please follow the recommended
techniques for best results:
•Use slow speed settings to get used to the
Magnassager’s action.
•Maintain constant contact with the body and
all three massage balls.
•Massage the muscle; keep clear from bony
protrusions.
•For individuals with low muscle mass, try the
Magnassager over a towel held taut.
•Use slow massage strokes.
•Let the Magnassager do the work for you.

Owner’s Manual
(4)
•Always grab by the plug to remove from outlet. DO NOT pull on cord.
•Never force the plug into an outlet.
• Never use while drowsy.
•Never block the air openings of the appliance or place it on a soft surface,
such as a bed or couch where the air openings may be blocked. Keep the air
openings free of lint, hair, and the like.
•Never drop or insert any objects into any opening or hose.
•Do not use outdoors or operate where aerosol (spray) products are being
used or where oxygen is being administered.
•The appliance should never be left unattended when plugged in. Unplug
from outlet when not in use, and before attaching or removing parts.
•Do not operate under a blanket or pillow. Excessive heating can occur and
cause fire, electric shock, or injury to persons.
•Do not operate near televisions, personal computers, floppy disks, compact
disks, pagers, cellular phones or other sensitive electronic equipment.
•The Magnassager contains a natural permanent magnet which emits a
negative pulsating magnetic field of 1000 gauss. Individuals with
pacemakers or detached defibrillators may be at risk.
• Do not carry this appliance by the supply cord or use the cord as a handle.
• To disconnect, turn all controls to the OFF position, then remove plug
from outlet.
•Never use pins, knives, tacks or any other metallic fasteners or objects near
the Magnassager.
•Keep children away from this appliance. If swallowed, massage balls may
become lodged in the throat.
•Do not drop or slam the Magnassager against any surface. If dropped on
control knob, it may short circuit. If dropped on the massage balls, it may
impact the magnet and break. Return the appliance to the factory or
manufacturer for examination and/or repair.
•Do not use the Magnassager on patients with pacemakers or internal
defibrillators.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFEGUARDS (cont.)

Owner’s Manual
(6)
nCord Care Instructions
When appliance is in use check cord periodically to make sure it has not
become twisted or tangled. If this occurs gently untwist cord and remove
tangles or knots.
DANGER
This product is factory equipped with a specific electric cord and plug to permit
connection to a proper electric circuit. Make sure that the product is
connected to an outlet having the same configuration as the plug. No adapter
should be used with this product. Do not modify the plug provided – if it will
not fit the outlet, have the proper outlet installed by a qualified electrician.
If the product must be reconnected for use on a different type of electric circuit,
the reconnection should be made by qualified service personnel.
nPower Supply:
Volts:..........................................................110V AC
Frequency: ..............................................60HZ
nProduct Specifications
Volts:..........................................................24V DC
Amps: ........................................................750 mA
Approximate rotational speed:..................33 to 76 rpms
Benefits
The Magnassager combines the benefits of massage, magnetic therapy, and
acupressure. The actual benefits are specific to the type of technique selected
when applying the Magnassager. Because the Magnassager is ergonomically
designed, its weight and rotating mechanism allows the user better control
while performing the massage. By applying uniform strokes and constant
pressure, the effectiveness of massage is greatly enhanced. In addition, forearm,
hand and finger fatigue which is a common experience with hand massage
is avoided when properly applying the Magnassager. Often, the root of
muscle discomfort lies deep within the tissue layers and requires a
progressive, thorough massage technique. This is one reason why the
Magnassager is so effective.
Product Features
(cont.)

Owner’s Manual
(8)
Special Considerations
nPacemakers
The Magnassager should not be used on individuals with pacemakers and/or
internal defibrillators.
nPain
The movement of oxygen-rich blood into the muscle, as well as the removal
of toxins, may result in discomfort for some individuals. The user should be
aware of the individual’s tolerance and comfort level during the massage and
adjust his/her technique accordingly.
nLow Muscle Mass
Individuals with low lean body mass or those with loose or flaccid skin have
bony protrusions and should use caution (e.g., scapula, iliac crest, ankles,
elbows, and knees). Those persons with loose skin are at risk because the skin
may collect under the massaging balls. The user should use their guiding hand
to stretch the skin under the unit to avoid this situation.
nHair
Although unlikely, the Magnassager may pull or tangle body hair. This may
be uncomfortable for the individual, therefore the user should encourage
feedback or choose to perform the massage over an article of clothing.
A water-based topical gel, lotion or oil over skin helps to inhibit pulling.
nAlcohol
Alcohol impedes the massage process and may interfere with the elimination of
toxins. Alcohol should be avoided within 24 hours of massage and directly after.
Alcohol effects may mask pain sensors and may result in further injury or
discomfort.
nDiabetes
Diabetic individuals may have peripheral neuropathy and circulatory
limitations. Massaging the feet and legs should be performed with caution.
nPregnancy
The Magnassager should not be used during pregnancy.
nMedications
Certain prescription drugs (i.e., pain medication, heart medication, blood
pressure medication, corticosteroids and blood thinners) may mask the pain
sensors and require caution.
nDehydration
Because massage stimulates lactic acid, carbon dioxide, lymph, blood and
oxygen flow, the user should encourage liberal water intake after each session.

Owner’s Manual
(10)
One Year Limited
Manufacturer’s Warranty
Your Magnassager is warranted, to the original owner, for one year from date
of purchase against all defects in material and workmanship under normal use
and service. Should your Magnassager prove defective within one year from the
date of purchase, contact Thane Fitness at 1-800-341-2369 with an explanation of
the problem and claim. If it is determined that your Magnassager should be
returned to the distributor please package your Magnassager carefully to avoid
damage in transit. Under this warranty, Thane International, Inc. will repair or
replace any parts found to be defective.
This warranty is only valid if the appliance is used solely for personal use in
accordance with the instructions. The warranty is invalid if the unit is connected
to an unsuitable electrical supply, or dismantled, or interfered with an any way,
or damaged through misuse, accidents, negligence, or is used in any manner for
which it is not intended. There are no warranties other than that expressly set
forth herein. This warranty is not transferable. This warranty applies only to the
product and Thane International, Inc. is not responsible in any way for damages,
losses or inconveniences caused by equipment failure. Thane International, Inc.
is not responsible or liable for indirect, special or consequential damages arising
out of or in connection with the use or performance of the product or other
damages with respect to any economic loss, loss of property, loss of revenues
or profits, loss of enjoyment or use, costs of removal, installation, other
consequential damages of whatsoever nature, failure to follow instructions or
warnings in owner’s manual or use of products in a manner for which they
were not designed. Some states do not allow the exclusion or limitation of
incidental or consequential damages. Accordingly, the above limitation may not
apply to you.
This warranty gives you specific legal rights. You may also have other rights
which vary from state to state.
This Warranty does not apply to the following:
1. Damage due to accidents, misuse, abuse, alteration, or vandalism.
2. Improper or inadequate maintenance
3. Unauthorized modification or commercial use.
4. Damage in return transit.
5. Normal wear and tear including chips, scratches, abrasions,
discoloration or fading.

Notes:
Owner’s Manual
(12)

This product is brought to you by:
www.thanefitness.com
Making Fitness Fun!®
Thane Fitness®is a division of Thane International, Inc.
Copyright © 2002 by Thane International, Inc.
All rights reserved.
Owner’s Manual
Other manuals for Magnassager
1
Table of contents
Other Thane Fitness Massager manuals