TPI PM-18FO User manual

Issue Date: 3-11-05 Rev. Date: 9-12-07 Rev. Level: 13 ECN: n/a OIPM P/N: 3420433
Pa e 1 of 8
1200 North Main St.
Fostoria, OH 44830
Phone: 800-495-4525
Fax: 419-435-0842
www.tpicorp.com
SELF-CONTAINED POWER MISTER
MODELS: PM-18FO, PM-18S, PM-18C
IMPORTANT SAFETY
INFORMATION INSIDE
• Serious injury or death possible.
• Read understand and follow all
safety information and
instructions in this manual before
using or servicing this product.
• Retain these instructions for
future reference.
CONTENTS
Specifications Pa es 2,3
PM-18C Assembly Pa es 3,4
Set-up / Operation Pa es 5,6
Replacement parts
Maintenance
Pa e 7
Pa e 8
Warranty Pa e 8
PM-18FO
PM-18S
PM-18C
If you have questions about the
product you have purchased or would
like to leave us feedback please
contact us via our website
www.fostoriaindustries.com
or by calling 1-800-4 5-4525.

Issue Date: 3-11-05 Rev. Date: 9-12-07 Rev. Level: 13 ECN: n/a OIPM P/N: 3420433
Pa e 2 of 8
SPECIFICATIONS
Fan Specifications
Volta e (VAC) 120
Frequency (Hz) 60
Amps 1.5
HP 1/8
CFM 5750
Speeds 1
TPI Corporation’s self-contained power mistin equipment is confi ured into three separate models:
An 18-inch fan head and pump enclosure. Model no. PM-18FO
An 18 inch fan head, pump enclosure, and 10 allon cooler. Model no. PM-18S
An 18-inch fan head, pump enclosure, 10 allon cooler and cart. Model no. PM-18C
MODEL:
PM
-
18FO
• One 18-inch fan head with white powder-
coated
uard mounted on a yoke attached to the pump
enclosure.
•
An inte ral round fault circuit interrupter (GFCI)
is attached to the power cord.
• Equipped with a power cutoff tip switch.
• One extra nozzle and two plu s included.
•
Shipped in a sin le carton and ready to assemble to
your existin 10- allon I loo cooler.
THANK YOU!!
Thank you very much for selectin TPI Corporation’s self-
contained power mistin equipment for your comfort
conditionin needs. These products were en ineered with the most reliabl
e components and materials available
and are equipped with features to assure ease of mobility, use, and maintenance.
The cool air you will now enjoy when usin this mistin equipment is created throu h the process of evaporation.
Heat is required to chan e water from a liquid to a as or “water vapor”. TPI Corporation’s self-
contained power
mistin equipment creates a “fo ” by pumpin water at a very low flow rate throu h small nozzles. When
combined with the air added by a fan, this fo is rapidly
evaporated. The heat required to evaporate the fo is
extracted from the air causin a reduced air temperature. This cooler air is then distributed to people or animals
creatin a direct coolin effect.
The performance of your mistin system can be aff
ected by local conditions. For best results, it may be
necessary to experiment with the number of nozzles operatin to achieve the coolin performance you desire.
Thank you a ain and stay cool!
All Models
Volta e (VAC) 120
Frequency (Hz) 60
Total Amps 2.2
Pump output 2 ph @ 130psi
Mistin hub 4 nozzles installed
Filter 50 mesh stainless steel
Water supply
PO
R
TABLE ONLY

Issue Date: 3-11-05 Rev. Date: 9-12-07 Rev. Level: 13 ECN: n/a OIPM P/N: 3420433
Pa e 3 of 8
SPECIFICATIONS (continued)
PM
-
18C CART ASSEMBLY & PARTS LIST
MODEL:
PM
-
18S
• One 18-inch fan head with white powder-
coated
uard mou
nted on a yoke attached to the pump
enclosure.
•
An inte ral round fault circuit interrupter (GFCI) is
attached to the power cord.
• Equipped with a power cutoff tip switch.
• One extra nozzle and two plu s included.
• A 10- allon I loo cooler is included for use
as water
reservoir.
• Shipped in two cartons and ready to assemble.
MODEL:
PM
-
18C
• One 18-inch fan head with white powder-
coated uard
mounted on a yoke that attaches to the cart mast.
• The cart base is supplied with two 10-
inch wheels and
a tray. (Customer assembly of these components is
required. See assembly instructions on pa e 4.)
•
An inte ral round fault circuit interrupter (GFCI) is
attached to the power cord.
• Equipped with a power cutoff tip switch.
• One extra nozzle and two plu s included.
• A 10-
allon I loo cooler is included for use as water
reservoir.
• Shipped in a sin le carton and ready to assemble.
ITEM
NO.
1
2
3
4
5
6
7
8
10
11
12
13
14
15
16
17
DESCRIPTION
Mast
Washer Flat 1/4
Hex Nut 1/4-20
Bolt Carriage 1/4-20 x 1-3/4”
Base
Base Tray
Push Nut
Washer Curved
Wheel 10”
Handle Grip
Screw Hex Head 1/2-13 x 1
Washer Lock 1/2”
Screw HWH 8-32 x 3/8
Yoke
Retaining strap
Nozzle (Brass)
Plug
PART NO.
35042001
3442532
3440132
340 456
84 700
3504121
8045700
3448056
8483100
340 100
2474400
341 500
2326500
3314721
44134001
44108001
44108002
QTY.
1
8
8
8
1
1
2
2
2
1
1
1
1
1
1
5
2
11
12
14
13
1
Fan yoke / Mast assembly
16
17

Issue Date: 3-11-05 Rev. Date: 9-12-07 Rev. Level: 13 ECN: n/a OIPM P/N: 3420433
Pa e 4 of 8
1
10
6
2
3
4
4
4
2
3
5 2
3
9
7
TOOLS REQUIRED: Screwdriver, adjustable wrench,
hammer, and pliers.
1. Place base (item 5) on flat work
surface with le s
downward as shown above. Install wheels onto axle;
makin sure the hub extension is facin inward
toward the base. Next place one push-
nut (item 7)
on axle and usin a hammer, seat in place with a
sharp blow. Repeat for other wheel.
2. Ins
tall tray (item 6) on base usin four carria e bolts
(item 4), and four each of washers and nuts (items 2
& 3) as shown. NOTE: Fin er-
ti hten only.
Adjustment may be necessary when securin mast to
tray.
3. Install mast (item 1) by boltin mast to tray and ba
se
assembly as shown above. Now ti hten all bolts.
4.
Place I loo cooler inside retainin rin on tray with
spout toward front.
5. Secure cooler to mast with retainin strap (item 15).
6.
Place pump enclosure on cooler. Make sure intake
line and filter are in bottom of cooler.
7.
Attach fan yoke (item 14) to top of mast (item 1)
usin 1/2-
13 x 1” screw (item 11) and 1/2” lock
washer (item 12). (See illustration on pa e 3.)
8. Position fan yoke as shown and install 8-
32 x 3/8”
screw (item 13) throu h yoke and into hole in
mast.
Ti hten securely. (See illustration on pa e 3.)
Pump
enclosure
Filter
Cooler
Spout
Retainin rin
Hub
extension
Retainin
strap
Fan
yoke
Attach retainin strap s-hooks
to bracket on mast.
PM
-
18C CART ASSEMBLY
(continued)
Intake line

Issue Date: 3-11-05 Rev. Date: 9-12-07 Rev. Level: 13 ECN: n/a OIPM P/N: 3420433
Pa e 5 of 8
•
Never operate pump without water supply.
• Check for leaks. If there are any, turn pump off and hand ti hten leaky fittin s.
• Excessively hard (hi-solids) water can plu nozzles.
• A plu ed filter caused by poor quality water can restrict flow to pump causin permanent dama e.
• Never allow the “fo ” from the nozzles to come in contact with surfaces. This will cause condensation and water
will form on those surfaces. Redirect the fan to prevent this circumstance.
SET
-
UP / OPERATION
1.
Always operate the Power Mister on a level
surface. In the event the un
it is tipped over or tilted
more than 35 de rees, a built-in tip-
over switch
will shut off power to the pump and fan. Power
will be restored when unit is placed in the upri ht
position.
2.
Fill cooler with clean fresh water (ice may be
added) each time mister
is used. Drain unused
water at the end of use period.
3.
Aim mister downwind for best results. If more than
one mister is used, arran e them in an arc around
the area to be misted.
4.
To ener ize, plu the GFCI safety plu into any
120 VAC 60 Hz rounded outlet.
Test GFCI per
instructions below. Turn on the two-
position
switch located on the top of the pump case. Turn to
either “Fan” (for air movement only) or “Fan /
Pump” (for air and mist).
5.
The mistin hub located in the center of the fan is
equipped with four
nozzles. The output volume of
water vapor can be reduced by replacin one or
two of the nozzles with the plu s provided.
6.
The unit will mist for approximately 5 hours on 10
allons of water.
GFCI SAFETY PLUG TEST
The GFCI plu mentioned above provides protection
from electric shock by examinin the product’s electrical
circuit for current leaka e. It must be tested before each
use to assure safe operation. Test as described below:
1. Plu into outlet –
the indicator will show if power is
available.
2. Press the test button – indicator will turn off.
3. Press reset button. Use product only if GFCI resets.
Do not use if above test fails.
ELECTRICAL SHOCK
HAZARD
PINCH HAZARD
TRIP HAZARD
• Serious injury or death may
occur.
• Only plug these models into
properly grounded receptacles.
• Disconnect from electric
supply before filling servicing
or moving this equipment.
• Test GFCI before using. See
instructions at left.
•
Do not carry unit by the motor
electric cords hose line fan
guard or support bars.
• Do not touch fan motor during
use or directly after it may be
hot.
• Do not operate fans without
guards in place.
• Do not insert anything into fan
guard while operating.
• Unplug unit and dry wet areas
before resetting unit that has
been tipped over.
• Position all electric cords to lie
flat on ground or floor.
• Never use during rain sleet
hail snow or any other
inclement weather conditions.
This manual suits for next models
2
Table of contents
Other TPI Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual