Tranquil Mount TMO-800E1 User manual

INSTALLATION GUIDE
Mantel Arm Mount
TMO-800E1
Support 45" to 100" Screens
Load Capacity: 110 lbs (50 kg)
VESA 800x600 compatible

7
2 of 8
Tools Needed for Assembly
WARNING
Table of Contents
Parts List ........................................................................................................................................................................ 3
Critical requirements of the installation . ... .......................................................................................................... 4
Installation of the bracket ........................................................................ ...................................................................
Installation of Screen & adjustment of the limit screw ....................................................................................................
5, 6
8
Product dimensions ........................................................................................................................................................
Maintenance instructions ................................................................................................................................................ 8
•
•
Be sure to read this entire manual thoroughly and you
• Sufficient expertise is required for installing of this product. Be sure to subcontract the installation to a qualified pe-
rson. Ensure special attention to safety is paid during installation. Tranquil mount is not liable for any damage or in-
jury caused by mishandling or improper installation, or by installing anything other than the specified product. Your
Statutory Rights, (if any) are not affected.
If the safety precautions are not observed or the product is used incorrectly, it may result to serious injury or dam-
age to your wall and TV.This instruction manual shows the correct handling of the product and important precauti-
ons necessary to prevent accident. Be sure to read this manual thoroughly and use the product correctly. Keep the
manual available for future reference.
• Ensure your hands and fingers stay clear from the adjustable moving mechanics at the back of the bracket. This is
to avoid your fingers getting trapped. Please supervise children when this product is in use.
• This product is supplied with small parts for installation. For your children’s safety please keep out of reach of chil-
dren at all times.
fully understand all the instructions and warning before
attempting to begin your installation.
Required Tools Optional Tools
3/16” 3/8”
Before you begin, please verify that all components are included and undamaged. If any parts are
missing or damaged, contact Product Supplier,Never proceed with missing or damaged parts!
Lay out all components and make sure you identify that each one has a match in the diagram.Some
of the parts included will not be used during installation.Do not proceed if you do not understand and
identify all of the components.
• This product should only be installed by someone who has a basic knowledge of buiding construction,installations and fully
understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the mount, the display and all
attached hardware and components.
• This wall bracket will only supporting flat panel displays(LCD,Plasma).The maximum load capacity is 110 pounds.
• If mounting to a wall of wood stud construction, be sure that mounting bolt are anchored to the center of the studs,
When installing the TV mount on a concrete wall, the wall must be at least 8"(203mm) thick with a minimum comp-
ressive strength from 2500 to 3000 psi (17.2 to 20.7 MPa),the concrete wall must meet ASTM C39. When installing
the TV mount on a cinder block wall, the cinder blocks must meet ASTM C216 specifications and have a minimum
nominal width of 8”(203mm). Be sure to mount in a solid part of the block, generally 1"(25 mm) minimum from the
side of the block.Do not drill into mortar joints! If plaster/drywall is thicker than 16mm,custom fasteners must be su-
pplied by the installer.
• Always have someone assist you to lift and position your equipment.
• T
• Screws must be tightly secured,but do not overtighten any screws (especially the four hex bolt screws M8x63.5mm)
or damage can occur and product may fail.
ighten screws and bolts firmly, but do not over tighten. Over tightening can damage the items and greatly reduce
their ability to hold. Please refer to suggested torque values where applicable in these instructions.

3 of 8
B
AA BB
CC DD
EE FF
LK M
A
C
D
2
hook(x2)Wallboard connection(x1)
wallboard(x2) beam(x1) bracket(x1)
E
F
4
4
4
4
2
8
4
M8x25
M8x12
M6x25
M6x12
φ16xφ6.2x1.0
philips pan head screw
C
washer(1)
D
4
philips pan head screw
philips pan head screw
philips pan head screw
M6x80
Socket heal screw
2M5x10
M8x10
philips pan head screw
allen pan head screw
B
4
H
J
K
L
4
G
φ17.0xφ9.0x14.0
spacer
N
M
M8x63.5
M10x61
φ
16x
φ
8.2x1.5
washer(2) 4
I
Hex bolt screw
Expansion pipe
1 M5
Hexagon wrench
2 Standard accessories
Hook block slice
with your product.
Parts may appear slightly different than illustrated.
Before you b egin, make sure all parts shown are included
Parts List
Description
A115x15x40
Wall panel cover(x2)
GH
E
J
F
I
1
Hexagon wrench
M5(x1)
N

4 of 8
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and
components, Bracket installation need two people together to complete.
WARNING
CRITICAL requirements of the installation
Temperature at the front edge of mantle should
never exceed 110° F(43℃).
Mantle must not extend from mounting surface
more than 14 inches.
The space above the mantle must be taller than the wallboard. The required space
depends on how far out the mantle extends. Refer to chart below and add this
additional height to wallboard height to determine if space is tall enough.
If the main wall is wooden,There must be at least 2 studs
available for mounting.If the main wall is concrete or brick
wall,please refer to the S4 installation points. Mind you,
the wall covering must not exceed 5/8 inches thick.
TV weight must be between 110 Ibs(50kg) and have
a screen size from 45” to 100”. Consult
Manual for verification.
TV Owner's
110°F
MAX.
14 inches
MAXIMUM
2 STUDS
(This two studs need along the
mantel center symmetric,and
the center distance between
two studs not more than 16”)
If mantle extends:
Less than 8 inches
8 - 10 inches
10 - 12 inches
12 - 14 inches
This is required space height:
TV wallboard height plus 8 inches
TV wallboard height plus 9 inches
TV wallboard height plus 10 inches
TV wallboard height plus 11 inches
Wallboard height
Mantle
Extends
Space height
from 45” to 100”
12
3
5
4
WEIGHT:
110Ibs(50kg)
C
L

5 of 8
Installation of the bracket
Measure the centerline of the mantle. Mark with tape on
the wall.
S1 S2
S4
Locate at least two studs with a stud finder. Locate the
center of these studs by using a sharp awl or finish nail
poked through the drywall to locate each edge. Lag bolts
must be installed into the CENTER of the studs.
C
L
C
L
Please reference point 5 at page 4 to punch, please
make sure that the four mounting holes don't have
too big deviation.
S3
Cutout shown
for reference
C
LC
L
C
L
C
L
C
L
6mm(3/16”)
CUTAWAY VIEW
INCORRECT
CORRECT
wall plate
plaster/
drywall
concrete
wall plate concrete
plaster/
drywall
C
L
10mm(3/8”)
M
Please reference point 5 at page 4 to p
unch,If the main
wall is concrete or brick wall,you must use the expansion
pipe we provided in M.
CL CL
CL
plywood wall wood stud wall
CL
CAUTION CAUTION
Do not drill into mortar joints!
10mm
(3/8”)
68mm
(2.7”)
6mm
(3/16”)
In order to have a better installa-
tion,it is necessary to inlay one
wire cassette on the wall. Refer
to S3 for the location
68mm
(2.7”)

6 of 8
Installation of the bracket
Take out CC/AA/E/N from the packaging , Select the app-
ropriate hole position according to the actual needs, and
lock it as shown in the figure.
Take out A/L from the packaging ,Use A to ensure insta-
llation level, let the pre-set wire go through the hole as
illustrated in the picture.
S5 S6
Take out E/N/EE from the packaging ,lock the four allen pan
head screws(M8x10) with Hexagon wrench in E , as is shown
in the pictures below.
Take out B/D/DD/FF from the packaging ,lock the two
socket heal screws(M6x80) with Hexagon wrench in E,
Complete these steps in sequence(1→2→3), finally,Put
the harness in place, as is shown in the pictures below.
S7 S8
1
2
2
3
LA
(magentic spirit level)
E
(Hexagon wrench)
EE (bracket)
(screw M8x10)
E(Hexagon wrench)
B(Socket heal screw)
D(Hook block slice)
FF
DD (beam)
E
(Hexagon wrench)
CC (wallboard)
AA
(wallboard connection)
N
(screw M8x10)
N
CAUTION
Don't over tighten!
In order to install more beautiful,
the power adapter should be pla-
ced inside of the wall.

7 of 8
Installation of Screen & adjustment of the limit screw
Select the parts from the packaging, and according to your
TV situation to choose F+J;or G+J+K;or H;or I+K,lock with
cross screwdriver.
To be safe, this step requires two people working together,
attach the TV set to the bracket, start the tripping device,
and use the screw C to lock the tripping device.
S9 S10
Understand the functions of the buttons of the remote control, then connect the power. Under the premise of ensuring safety,
adjust the action limit of the bracket slowly, this should be done strictly, in order to prevent damage to the TV and pinch hands.
If the TV is big enough, there is a chance it could
crash into the mantelpiece.This must be avoided.
Use the C/D button of the remote
control to make the bottom of the
TV set level with the mantelpiece.
Use the A/B button of the remote
control to slowly adjust to a safe
position.(Factory setting: ± 13°)
The left screw controls the right position of the TV,
The right screw controls the left position of the TV,
Don't use too much force,in order to avoid damage.
S11
1 4
2
3
F/G (H&I don’t need J)
J
BB
K(F&H need K)
(washer φ16xφ6.2x1.0)
1
2
C
D Down
C Up
A Left B Right
The AC standard required for the equipment
is 110~230V, and the power required for the
device is DC24V 6A.Do not exceed this range!
Tear off the receiver's 3M
protective paper and glue
the receiver to the unshi-
elded position of the devi-
ce to better receive the
control signal.
Paste in the middle of the
bottom of the display, don’t
limit the cable too tightly.
LEVEL
safe distance 2’’
E

8 of 8
TMO-800E1
swivel:±13°
tilt:+3°
for 45~100” screens
load capacity:110Lbs
from 206 to 826.9mm
616.0mm
185.0mm
650.0mm
8.5
42.0mm
70.0mm
780.1mm
316.7mm
164.0mm
880.0mm
removable:152.4mm removable:152.4mm
MAX683.0mm
101°
from143.0 to 632.3mm
143.0mm
20.0mm
±13°
3°
Table of contents
Other Tranquil Mount Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Copernicus
Copernicus HAWM Assembly guide

Triton
Triton LB18-1THBBK-Kit Installation & assembly instructions

Bose
Bose RoomMatch RMBRKT Installation and safety guidelines

PEERLESS
PEERLESS Smartmount SA752PU Installation and assembly

Wize
Wize F46A instruction manual

peerless-AV