Tempest™ Pillar Mount
(sku 94800826)
Page 1 of 2 17601540 - 2/17/21 © Travis Industries, Inc.
Compatibility
This post is for use with the following permanent-mount Tempest models
Tempest Torch 24v (LP - 94900755 & NG - 94900745)
Tempest Torch Manual Start (LP - 94900753 & NG - 9490043)
Tempest Lantern 24v (LP - 94900757 & NG - 94900747)
Tempest Lantern Manual Start (LP - 94900756 & 94900746)
Packing List
Pillar Mount
Pillar Cover
16” Gas Flex Line
3/8” to 3/8” Flare Fitting
(2) 8-32 Thumb Screws
Pillar Mount Attachment
NOTE: The illustration below is for example only. Make sure to follow all gas line and building code requirements
for your location. The base may be shimmed to level the mount.
1”-2”
Gas Inlet
pillar mount)
5” (includes cover)
3-3/8”
5” (includes cover)
11”
Pillar Mount
Flex Tube (Accepts 3/8” Flare Fitting)
Gas Inlet
(1” to 2” above surface)
26” Clearance to
Combustibles
8” Clearance to
Combustibles
(all sides)
Torch attaches to the post with 4 screws
(included with torch - see torch manual for
details).
3/8” to 3/8” Flare Fitting
(included with pillar mount)
33”
(when installed)
Pillar Cover
Fitting (pipe to 3/8” Flare)
NOT INCLUDED
MAKE SURE TO PUT SEVERAL
INTO THE TUBE (this allows the flex tube and
control assembly to slide into the pillar).
*See clearance
note below
*See clearance
note below
To grade
* :NOTE The distance from ground level to the top of the Torch shall be a minimum of 7’ (2.1m) where
installed within 2’ (0.6M) of public walkways (e.g.: sidewalk, shared walkway between two
homes, or pathway in commercial applications). Lesser clearances shall be permitted to be
used only where acceptable to the authority having jurisdiction.
63” - Minimum height above grade the top of the post must be above grade to meet this requirement.
Secure the pillar mount
to a stable surface using
four lag or through-bolts
(not included)
Place the pillar cover
over the pillar mount
and secure with the
included thumb screws.